# TCDS B00010CH: Lindstrand Balloons USA Inc.

- Type: Type certificate data sheet
- Status: Current
- Holder: Lindstrand Balloons USA Inc.
- Revision: 13
- Revised: July 8, 2022
- Product: Aircraft, Balloon
- Certification basis: Part 31
- Registered aircraft: 159, by the registry models matched to it (OpenAirDocs)
- Data sheet PDF: https://openairdocs.org/files/sha256/69/97/6997103da61eabf967eb103694ba81642c7dbb5b83b0bd5c1189db08c25209ff
- FAA DRS: https://drs.faa.gov/browse/excelExternalWindow/B5627D7724603AA78625887C004EFDBF.0001
- Page: https://openairdocs.org/tcds/B00010CH

## Models (37)

As the data sheet lists them.

- 260A
- 77B
- 90B
- 150A
- 90A
- 56A
- 69X
- 69A
- 210A
- 42A
- 69B
- 160A
- 105B
- 105A
- 77X
- LBL BOX
- 210S
- 140A
- 240A
- 310A
- CAN-90
- 180A
- SPHERE-105
- 60A
- 60X
- 77A
- 120A
- 56X
- 65X
- 317A
- 330A
- 50E
- 60E
- 70E
- 80E
- 90E
- 100E

## What the data sheet says

From the PDF's text layer, line by line; tables lose their columns. The PDF is the record.

```text
Page No.  1  2  3  4  5  6  7  8  9 10 11 12 13 14 15 16 17 18 19 20 21 
Rev. No. 12 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 12 13 12 12 
 
DEPARTMENT OF TRANSPORTATION 
FEDERAL AVIATION ADMINISTRATION 
 
B00010CH 
Revision 13 
LINDSTRAND 
USA 
(KEMPNER) 
42A  210A 
56A  210S 
56X  240A 
58X   
60A  260A 
60X  310A 
62X   
65X  317A 
69A  330A 
69X  69B 
77A  77B 
77X  90B 
90A  105B 
105A  50E 
120A  60E 
140A  70E 
150A  80E 
160A  90E 
180A  100E 
  CAN-90 
          LBL BOX 
     SPHERE-105 
July 8, 2022 
 
TYPE CERTIFICATE DATA SHEET NO. B00010CH 
 
This data sheet, which is part of Type Certificate No. B00010CH, prescribes conditions and limitations under which the 
product for which the type certificate was issued meets the airworthiness requirements of the Federal Aviation Regulations. 
 
Type Certificate Holder: Lindstrand Balloons USA, Inc. 
 11440 Dandar Street 
 Galena, IL 61036 
 
Type Certificate Holder Record: Elisabeth A. Kempner transferred TC 
B00010CH to Lindstrand Balloons USA, Inc. on 
April 30, 2008 
 
I - Model 42A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 42,000 cu.ft., drawing EA-042-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-004-A-001, BA-005-A-001, BA-006-A-
001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 924 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF.

B00010CH  2 of 21 
 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
II - Model 56A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 56,000 cu.ft, drawing EA-056-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-005-A-
001, BA-006-A-001, BA-006-A-002, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1232 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
III - Model 60A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 60,000 cu.ft., drawing EA-060-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, and 
BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1320 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos.

3 of 21 B00010CH 
 
   Eligible 5135 and up. 
 
 
 
IV - Model 69A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 69,000 cu.ft., drawing EA-069-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-
009-A-001 and BA-262-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1518 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
V - Model 77A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 77,000 cu.ft., drawing EA-077-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-
008-A-001, BA-009-A-001, and BA-262-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1694 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up.

B00010CH  4 of 21 
 
 
VI - Model 90A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 90,000 cu.ft., drawing EA-090-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001, 
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-008-A-001, 
BA-009-A-001, BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001, 
BA-264-A-001, BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 
 Maximum Weight 1980 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
  
 Serial Nos. 
   Eligible 5135 and up. 
 
VII - Model 105A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 105,000 cu.ft., drawing EA-105-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-002-A-001, BA-002-A-002, BA-003-A-001, BA-003-A-002, 
BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-008-A-001, BA-010-A-001, BA-011-A-001, 
BA-011-A-002,  BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001, 
and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2310 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up.

5 of 21 B00010CH 
 
VIII - Model 120A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 120,000 cu.ft., drawing EA-120-A-001. 
 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Double Burner, drawing BU-002-A-001. 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-003-A-001, BA-003-A-002, BA-008-A-001, BA-010-A-001, 
BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-001, BA-014-A-001, BA-015-A-001, 
BA-034-A-001, BA-035-A-001, BA-040-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, 
BA-244-A-001, BA-265-A-001, BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2640 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
IX - Model 150A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 150,000 cu.ft., drawing EA-150-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Double Burner, drawing BU-002-A-001. 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-
001, BA-014-A-001, BA-015-A-001, BA-020-A-001, BA-031-A-001, BA-034-A-001, BA-
035-A-001, BA-040-A-001, BA-263-A-001, BA-264-A-001, BA-244-A-001, and BA-265-A-
001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 3190 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6).

B00010CH  6 of 21 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
 
 
X - Model 180A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 180,000 cu.ft., drawing EA-180-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Double Burner, drawing BU-002-A-001. 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawing BU-008-A-001, BU-008-A-002. 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-013-A-001, BA-014-A-001, BA-015-A-001, BA-020-A-
001, BA-021-A-001, BA-022-A-001, BA-023-A-001, BA-024-A-001, BA-025-A-001, BA-
028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-033-A-001, BA-034-A-001, 
BA-035-A-001, BA-036-A-001, BA-037-A-001, BA-038-A-001, BA-040-A-001, BA-244-A-
001, and BA-265-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 3586 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XI - Model 210A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 210,000 cu.ft., drawing EA-210-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawing BU-008-A-001, BU-008-A-002. 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-015-A-001, BA-020-A-001, BA-021-A-001, BA-022-A-
001, BA-023-A-001, BA-024-A-001, BA-025-A-001, BA-026-A-001, BA-028-A-001, BA-
030-A-001, BA-031-A-001, BA-032-A-001, BA-033-A-001, BA-034-A-001, BA-035-A-001, 
BA-036-A-001, BA-037-A-001, BA-038-A-001, and BA-040-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 4180 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF.

7 of 21 B00010CH 
 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
 
 
XII - Model 240A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 240,000 cu.ft., drawing EA-240-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 
 Baskets Lindstrand Baskets to drawings BA-021-A-001, BA-022-A-001, BA-023-A-001, 
BA-024-A-001, BA-025-A-001, BA-026-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-
001, BA-032-A-001, BA-033-A-001, BA-034-A-001, BA-035-A-001, BA-036-A-001, and 
BA-037-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 4800 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XIII - Model 260A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 260,000 cu.ft., drawing EA-260-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Triple Burner, drawing BU-004-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 
 Baskets Lindstrand Baskets to drawings BA-022-A-001, BA-023-A-001, BA-024-A-001, BA-025-A-
001, BA-026-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-
033-A-001, BA-036-A-001, and BA-037-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 5200 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up.

B00010CH  8 of 21 
 
 
XIV - Model 310A, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 310,000 cu.ft., drawing EA-310-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 2 Burner Assembly: 
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 
 Baskets Lindstrand Baskets to drawings BA-022-A-001, BA-024-A-001, BA-025-A-001, BA-026-A-
001, BA-027-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-
033-A-001, BA-036-A-001, and BA-037-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 6200 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
  
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XV - Model 69B, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 69,000 cu.ft., drawing EB-069-A-001. 
 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1518 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XVI - Model 77B, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 77,000 cu.ft., drawing EB-077-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001.

9 of 21 B00010CH 
 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, and 
BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1694 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XVII - Model 90B, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 90,000 cu.ft., drawing EB-090-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001, 
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-009-A-001, 
BA-011-A-001, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001,  
and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1989 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XVIII - Model 105B, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 105,000 cu.ft., drawing EB-105-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly:

B00010CH  10 of 21 
 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-002-A-001, BA-002-A-002, BA-003-A-001, BA-003-A-002, 
BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-010-A-001, BA-011-A-001, BA-012-A-001, 
BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2310 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5135 and up. 
 
XIX - Model CAN-90, Hot Air Balloon, Approved December 20, 1999 
 
 Envelope Volume: 90,000 cu.ft., drawing SS-009-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
  
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001, 
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-009-A-001, 
BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, 
BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1980 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
  
 Serial Nos. 
   Eligible 5135 and up. 
 
XX - Model SPHERE-105, Hot Air Balloon, Approved May 8, 2001 
 
 Envelope Volume: 105,000 cu.ft., drawing SS-023-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001.

11 of 21 B00010CH 
 
 Baskets Lindstrand Baskets to drawings BA-003-A-001, BA-003-A-002, BA-006-A-001, BA-007-A-
001, BA-008-A-001, BA 010 A 001, BA-011-A-001, BA-011-A-002, BA-262-A-001, BA-
263-A-001, BA-264-A-001, BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2310 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5167 and up. 
 
XXI - Model 210S, Hot Air Balloon, Approved August 30, 2002 
 
 Envelope Volume: 210,000 cu.ft., drawing ES-210-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
 Triple Burner, drawing BU-004-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawing BU-008-A-001, BU-008-A-002. 
 Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
 Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-015-A-001, BA-020-A-001, BA-021-A-001, BA-022-A-
001, BA-023-A-001, BA-024-A-001, BA-025-A-001, BA-026-A-001, BA-028-A-001, BA-
030-A-001, BA-031-A-001, BA-032-A-001, BA-033-A-001, BA-034-A-001, BA-035-A-001, 
BA-036-A-001, BA-037-A-001, BA-038-A-001, and BA-040-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 4180 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5211 and up. 
 
XXII - Model 60X, Hot Air Balloon, Approved June 11, 2003 
 
 Envelope Volume: 60,000 cu.ft., drawing EX-60-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001.

B00010CH  12 of 21 
 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1320 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5233 and up. 
 
XXIII - Model 56X, Hot Air Balloon, Approved September 30, 2004 
 
 Envelope Volume: 56,000 cu.ft., drawing EX-56-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1232 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5281 and up. 
 
XXIV - Model 69X, Hot Air Balloon, Approved September 30, 2004 
 
 Envelope Volume: 69,000 cu.ft., drawing EX-69-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-009-A-001, and 
BA-262-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1518 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual.

13 of 21 B00010CH 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5281 and up. 
 
XXV - Model LBL BOX, Hot Air Balloon, Approved July 18, 2006 
 
 Envelope Volume: 120,000 cu.ft., drawing SS-029-A-010. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
 Triple Burner, drawing BU-004-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
 Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-003-A-001, BA-003-A-002, BA-007-A-001, BA-008-A-001, 
BA-010-A-001, BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-001, BA 014 A 001, 
BA-015-A-001, BA-034-A-001, BA-035-A-001, BA-040-A-001, BA-262-A-001, BA-263-A-001, 
BA-264-A-001, BA-270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2640 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5300 and up. 
 
 
XXVI - Model 160A, Hot Air Balloon, Approved August 10, 2012 
 
 Envelope Volume: 160,000 cu.ft., drawing EA-160-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
 Triple Burner, drawing BU-004-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
 Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-
001, BA-014-A-001, BA-015-A-001, BA-020-A-001, BA-031-A-001, BA-034-A-001, BA-
035-A-001, BA-036-A-001, BA-040-A-001, BA-244-A-001, BA-264-A-001, and BA-265-A-
001. 
 
 Fuel Commercial LPG or Propane.

B00010CH  14 of 21 
 
 
 Maximum Weight 3520 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5518 and up. 
 
XXVII - Model 140A, Hot Air Balloon, Approved March 1, 2013 
 
 Envelope Volume: 140,000 cu.ft., drawing EA-140-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Double Burner, drawing BU-002-A-001. 
 Triple Burner, drawing BU-004-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
 Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-
001, BA-014-A-001, BA-015-A-001, BA-034-A-001, BA-035-A-001, BA-040-A-001, BA-
263-A-001, BA-264-A-001, BA-244-A-001, and BA-265-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 3086 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5528 and up. 
 
 
XXVIII - Model 77X, Hot Air Balloon, Approved March 27, 2013 
 
 Envelope Volume: 77,000 cu.ft., drawing EX-77-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, 
BA-009-A-001, and BA-262-A-001. 
 
 Fuel Commercial LPG or Propane.

15 of 21 B00010CH 
 
 Maximum Weight 1694 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 Minimum Crew One (1) Pilot. 
 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5532 and up. 
 
XXIX - Model 65X, Hot Air Balloon, Approved March 19, 2015 
 
 Envelope Volume: 65,000 cu.ft., drawing EX-65-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1433 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5587 and up. 
 
XXX - Model 317A, Hot Air Balloon, Approved March 1, 2017 
 
 Envelope Volume: 317,000 cu.ft., drawing EA-317-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
   Triple Burner, drawing BU-004-A-001. 
  Lindstrand Jetstream Series 2 Burner Assembly: 
   Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003. 
   Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 
 Baskets Lindstrand Baskets to drawings BA -024-A-001, BA-025-A-001, BA-026-A-001, BA-027-A-
001, BA-028-A-001, BA-029-A-001, BA-032-A-001, BA-033-A-001, and BA-037-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 6340 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257 oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot.

B00010CH  16 of 21 
 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 
 Serial Nos. 
   Eligible 5630 and up. 
 
XXXI - Model 330A, Hot Air Balloon, Approved March 1, 2017 
 
 Envelope Volume: 317,000 cu.ft., drawing EA-330-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 2 Burner Assembly: 
   Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003. 
 
 Baskets Lindstrand Baskets to drawings BA -024-A-001, BA-025-A-001, BA-026-A-001, BA-027-A-
001, BA-028-A-001, BA-029-A-001, BA-032-A-001, BA-033-A-001, and BA-037-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 6600 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257 oF. to 
275oF. 
  3. Maximum continuous: 257oF 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5630 and up. 
 
XXXII - Model 50E, Hot Air Balloon, Approved June 27, 2018 
 
 Envelope Volume: 50,000 cu.ft., drawing EE-050-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-004-A-
001, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-007-A-002, BA-
009-A-001 and BA-009-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1100 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5652 and up. 
 
 
XXXIII - Model 60E, Hot Air Balloon, Approved June 27, 2018 
 
 Envelope Volume: 60,000 cu.ft., drawing EE-060-A-001.

17 of 21 B00010CH 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-004-A-
001, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-007-A-002, BA-
009-A-001 and BA-009-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1320 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5652 and up. 
 
 
 
XXXIV - Model 70E, Hot Air Balloon, Approved June 27, 2018 
 
 Envelope Volume: 70,000 cu.ft., drawing EE-070-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-004-A-001, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-
007-A-001, BA-007-A-002, BA-009-A-001, BA-009-A-002, BA-262-A-001, BA-270-A-001 
and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1540 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5652 and up. 
 
 
XXXV - Model 80E, Hot Air Balloon, Approved June 27, 2018 
 Envelope Volume: 80,000 cu.ft., drawing EE-080-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001.

B00010CH  18 of 21 
 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
Lindstrand Vortech Burner Assembly: 
Double Burner, drawing BU-001-A-001. 
 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002,  
  BA-003-A-001, BA-003-A-002, BA-004-A-001, BA-005-A-001, BA-006-A-001, 
   BA-006-A-002, BA-007-A-001, BA-007-A-002, BA-008-A-001, BA-008-A-002,  
  BA-009-A-001,  BA-009-A-002, BA-262-A-001, BA 270-A-001,  and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1760 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5652 and up. 
 
 
 
XXXVI - Model 90E, Hot Air Balloon, Approved March 4, 2019 
  
 Envelope Volume: 90,000 cu.ft., drawing EE-090-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
Super Single Burner, drawing BU-007-A-001. 
Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
Lindstrand Vortech Burner Assembly: 
Double Burner, drawing BU-001-A-001. 
 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002,  
  BA-003-A-001, BA-003-A-002, BA-004-A-001, BA-005-A-001, BA-006-A-001,  
  BA-006-A-002, BA-007-A-001, BA-008-A-001, BA-009-A-001, BA-262-A-001,  
  BA-263-A-001, BA-264-A-001, BA 270-A-001, and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1980 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5683 and up. 
 
 
XXXVII - Model 100E, Hot Air Balloon, Approved March 4, 2019 
 
 Envelope Volume: 100,000 cu.ft., drawing EE-100-A-001.

19 of 21 B00010CH 
 
 Air Heaters Double Burner, drawing BU-002-A-001. 
Lindstrand Jetstream Series 2 Burner Assembly: 
Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-002-A-001, BA-002-A-002, BA-003-A-001, BA-003-A-002, 
BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-008-A-001, BA-010-A-001, BA-011-A-001, 
BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001,  
and BA-270-A-002. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 2200 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5683 and up. 
 
 
 
 
 
XXXVIII - Model 58X, Hot Air Balloon, Approved July 8, 2022 
 
 Envelope Volume: 58,000 cu.ft., drawing EX-58-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001. 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1276 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5758 and up. 
 
XXXIX - Model 62X, Hot Air Balloon, Approved July 8, 2022 
 
 Envelope Volume: 62,500 cu.ft., drawing EX-62-A-001. 
 
 Air Heaters Lindstrand Jetstream Series 1 Burner Assembly: 
 Super Single Burner, drawing BU-007-A-001.

B00010CH  20 of 21 
 
 Double Burner, drawing BU-002-A-001. 
 Lindstrand Jetstream Series 2 Burner Assembly: 
 Double Burner, drawings BU-008-A-001 and BU-008-A-002. 
 Lindstrand Vortech Burner Assembly: 
 Double Burner, drawing BU-001-A-001. 
 
 Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001. 
 
 Fuel Commercial LPG or Propane. 
 
 Maximum Weight 1375 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF, 
whichever is less.  See approved Balloon Flight Manual. 
 
 Allowable Envelope 
  Temperature 1. Never exceed: 275oF. 
  2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to 
275oF. 
  3. Maximum continuous: 257oF. 
 
 Minimum Crew One (1) Pilot. 
 
 Fuel Capacity Two standard cylinders must be present (see also NOTE 6). 
 
 Serial Nos. 
   Eligible 5759 and up. 
 
 
 
Data Pertinent to All Models 
 
 Certification 
   Basis Part 31 of the Federal Aviation Regulations dated July 1, 1964, as amended by 31-1 through 
31-6.  Application for Type Certificate dated April 24, 1996.  Type Certificate No. B00010CH 
issued December 20, 1999. 
 
 Production 
   Basis A.R.B.C., Inc. dba Lindstrand Balloons USA Production Certificate No. 336CE, all serial 
numbers. 
 
 Equipment In addition to the basic equipment required by the Certification Basis, the following equipment 
is also required: 
 
(1)  Fire extinguisher rated at least 1A:10BC 
(2)  Two sources of ignition (striker, matches or equivalent). 
(3)  Leather gloves or equivalent for the pilot. 
(4)  FAA Approved Balloon Flight Manual dated December 20, 1999 or later approved 
revision. 
 Maintenance and 
   Inspection Maintenance and Inspection of this Aircraft must be carried out according to the most recent 
publication of the Lindstrand Balloons USA Instructions for Continued Airworthiness 
(original date of issuance:  November 20, 1998). 
 
NOTE 1. Reserved. 
 
NOTE 2. Reserved. 
 
NOTE 3. Reserved. 
 
NOTE 4. Each hot air balloon envelope must have an individual registration number.  An individual envelope is 
eligible for a Standard Airworthiness Certificate when mated with any approved combination of basket and 
burner assembly.  Change to an eligible combination must be endorsed by logbook entry by the Pilot-in-
Command or by a FAA Certificated Repairman. 
 
 When Lindstrand Balloons USA manufactures an envelope-only, it is assembled to an appropriate burner, 
basket and fuel tanks (bottom end) and is flight tested, and it is then eligible for a standard airworthiness 
certificate.  When this occurs, Lindstrand Balloons USA will deliver the balloon envelope with a standard 
airworthiness certificate, and a logbook. 
 
 When the balloon owner receives the new balloon envelope, it must be assembled to an eligible bottom end.  
The installation of the burners, baskets, and fuel tanks is recorded into the logbook and endorsed by the 
owner/operator or by an FAA Certificated Repairman. 
 
 The envelope owner must register the balloon in accordance with applicable requirements.

21 of 21 B00010CH 
 
 
NOTE 5. For the purpose of maintenance and inspection, operation records (logbooks) must be maintained with each 
hot air balloon envelope.  If burner, basket, instruments, and/or tanks are interchanged, separate logbooks 
must be maintained for each component or group of components which are always used together. The Flight 
Manual must be presented to an FAA Certificated Repair Station during annual inspections for verification of 
components being inspected. 
 
NOTE 6. A minimum of one standard fuel cylinder must be present for each fuel feed to the burner assembly; i.e. for 
balloons equipped with single or double burners, two standard cylinders must be present; for balloons 
equipped with a triple burner, three standard cylinders must be present; for balloons equipped with quad 
burners, four standard cylinders must be present.  The approved types of fuel cylinders for all models are as 
follows 
 
 Fuel Tank Type Capacity Part No. 
 V20 Vertical 10 gallons to 80% fill CY-020-A-001 
 V30 Vertical 15 gallons to 80% fill CY-030-A-001 
 V40 Vertical 21 gallons to 80% fill CY-040-A-001 
 T30 Vertical 12.9 gallons to 80% fill CY-050-A-001 
 
NOTE 7. Due to a large degree of similarity of design, certain baskets, burners and fuel cylinders manufactured by 
either Cameron Balloons or Thunder & Colt, may be used in conjunction with a Lindstrand Balloons USA 
manufactured envelope, subject to the limitations given in Section 4 of the approved Lindstrand Balloons 
USA Flight Manual. 
 
NOTE 8. In addition to any instrumentation approved for use in or by Aerostar International, Cameron Balloons USA, 
Thunder & Colt, UltraMagic, or Balony Kubicek, the following instruments may be used with all hot air 
balloon models, as specified on this Type Certificate Data Sheet: 
 
 Flytec 3020 
 Flytec 3040 
 Ball 502 
 Ball 655 
 Ball M55 
 Alibi Piccolo ACT 5000 
 Alibi Piccolo ACT 8000 
 United Instruments 10-04550 
 United Instruments 10-05200 
 
NOTE 9. Due to the similarity of design, certain baskets, burners and fuel cylinders manufactured by Aerostar 
International, UltraMagic, and Kubicek may be used in conjunction with a Lindstrand Balloons USA 
manufactured envelope.  This installation is subject to the operations and limitations given in the approved 
Lindstrand Balloons Flight Manual Supplement 005 (Aerostar), 008 (UltraMagic), or 009 (Kubicek).  These 
supplements are required equipment and must be carried onboard the aircraft. 
 
-- END --
```

## ADs (1, in force first)

- [AD 2013-03-10](https://openairdocs.org/ad/2013-03-10): Hardware · Aeronaut Instruction Research Skysailor 105, Skysailor 90, 110C and 439 more. Effective Mar 19, 2013

## Registered aircraft by registry model (OpenAirDocs)

- [Arbc Inc DBA Lindstrand 77X](https://openairdocs.org/model/arbc-inc-dba-lindstrand-77x): 38 aircraft (registry code 5190026)
- [Arbc Inc DBA Lindstrand 60X](https://openairdocs.org/model/arbc-inc-dba-lindstrand-60x): 34 aircraft (registry code 5190021)
- [Lindstrand Balloons 60X](https://openairdocs.org/model/lindstrand-balloons-60x): 14 aircraft (registry code 5180017)
- [Arbc Inc DBA Lindstrand 69X](https://openairdocs.org/model/arbc-inc-dba-lindstrand-69x): 13 aircraft (registry code 5190022)
- [Arbc Inc DBA Lindstrand 65X](https://openairdocs.org/model/arbc-inc-dba-lindstrand-65x): 12 aircraft (registry code 5190028)
- [Lindstrand Balloons 56X](https://openairdocs.org/model/lindstrand-balloons-56x): 8 aircraft (registry code 5180032)
- [Arbc Inc DBA Lindstrand 160A](https://openairdocs.org/model/arbc-inc-dba-lindstrand-160a): 7 aircraft (registry code 5190025)
- [Arbc Inc DBA Lindstrand 56X](https://openairdocs.org/model/arbc-inc-dba-lindstrand-56x): 6 aircraft (registry code 5190024)
- [Arbc Inc DBA Lindstrand 140A](https://openairdocs.org/model/arbc-inc-dba-lindstrand-140a): 3 aircraft (registry code 5190027)
- [Arbc Inc DBA Lindstrand 180A](https://openairdocs.org/model/arbc-inc-dba-lindstrand-180a): 3 aircraft (registry code 5190010)
- [Arbc Inc DBA Lindstrand 90E](https://openairdocs.org/model/arbc-inc-dba-lindstrand-90e): 3 aircraft (registry code 5190030)
- [Lindstrand Balloons 69X](https://openairdocs.org/model/lindstrand-balloons-69x): 3 aircraft (registry code 5180013)
- [A R B C Inc DBA Lindstrand 62X](https://openairdocs.org/model/a-r-b-c-inc-dba-lindstrand-62x): 2 aircraft (registry code 5190037)
- [Arbc Inc DBA Lindstrand 100E](https://openairdocs.org/model/arbc-inc-dba-lindstrand-100e): 2 aircraft (registry code 5190042)
- [Arbc Inc DBA Lindstrand 70E](https://openairdocs.org/model/arbc-inc-dba-lindstrand-70e): 2 aircraft (registry code 5190003)
- [Arbc Inc DBA Lindstrand 80E](https://openairdocs.org/model/arbc-inc-dba-lindstrand-80e): 2 aircraft (registry code 5190031)
- [Thunder & Colt Balloons 160A](https://openairdocs.org/model/thunder-colt-balloons-160a): 2 aircraft (registry code 2301200)
- [Arbc Inc DBA Lindstrand 150A](https://openairdocs.org/model/arbc-inc-dba-lindstrand-150a): 1 aircraft (registry code 5190033)
- [Arbc Inc DBA Lindstrand 317A](https://openairdocs.org/model/arbc-inc-dba-lindstrand-317a): 1 aircraft (registry code 5190035)
- [Arbc Inc DBA Lindstrand SPHERE-105](https://openairdocs.org/model/arbc-inc-dba-lindstrand-sphere-105): 1 aircraft (registry code 5190020)
- [Colt Balloons 160A](https://openairdocs.org/model/colt-balloons-160a): 1 aircraft (registry code 2300160)
- [Lindstrand Balloons 210S](https://openairdocs.org/model/lindstrand-balloons-210s): 1 aircraft (registry code 5180030)
- [Lindstrand Balloons LBL BOX](https://openairdocs.org/model/lindstrand-balloons-lbl-box): 0 aircraft (registry code 5180034)

## STCs approved under this data sheet (25)

- [STC SB10564SC](https://openairdocs.org/stc/SB10564SC): Installation of Night Position Lights. Highland Balloon Repair, CRS NHMD682X
- [STC SB09657RC](https://openairdocs.org/stc/SB09657RC): Installation of Aircraft Position Lights. Albuquerque Balloon Center, Inc.
- [STC SB04407AT](https://openairdocs.org/stc/SB04407AT): Installation of the DBI-III Omega. Balloonacy, Ltd. LLC
- [STC SB04233CH](https://openairdocs.org/stc/SB04233CH): Replace Lindstrand Basket/Burner system and fuel tanks with the Firefly Basket part number 4.9, S/N 138, or part number 3.9, S/N A167. David Boesdorfer
- [STC SB04087CH](https://openairdocs.org/stc/SB04087CH): Replace the Lindstrand Balloons USA Basket/Burner system and fuel tanks with the FireFly Balloons Basket Model 4.9A1, S/N 289; the FireFly Balloons Burner Model T3-017, S/N 2163J; and FireFly Balloons fuel tanks, Part Number 3035, S/Ns 75032J, 15369J, and 37088; and Part Number 3229, S/N 47528J. Charles Mays Jr.
- [STC SB04069CH](https://openairdocs.org/stc/SB04069CH): Replace the Lindstrand Balloons USA Basket/Burner system and fuel tanks with the Balony Kubicek Basket Model K13, S/N 509; the Balony Kubicek Burner Model IGNIS 2 Units, S/N 1113 and 1114; Schroeder Fire Balloons fuel tank, Part Number VA70, S/Ns A3145, A2849, and A2850627; and Thunder & Colt fuel tank, Part Number V30, S/N 2270. Deborah L Young
- [STC SB03468CH](https://openairdocs.org/stc/SB03468CH): Replace the Lindstrand Balloons fabric with Head Balloons Inc. 1.9 oz fabric (with either polyurethane or silicone coating) for repairs.. Gary M. Prentice
- [STC SB03456CH](https://openairdocs.org/stc/SB03456CH): Replace the Lindstrand Balloons Ltd Basket/Burner system and fuel tanks. Michael Reinert
- [STC SB03447CH](https://openairdocs.org/stc/SB03447CH): Replace the Lindstrand Balloons USA fabric with Westmark Corp. 1.9 oz fabric (with either polyurethane or silicone coating) for repairs on this balloon.. Gary M. Prentice
- [STC SB03391CH](https://openairdocs.org/stc/SB03391CH): Replace the Lindstrand Balloons Basket/Burner system and fuel tanks with the Balony Kubicek Basket Model K12, S/N 438; the Balony Kubicek Burner Model IGNIS 2 Units, S/N 747 and 748; and Schroeder Fire Balloons fuel tank, Model VA70, S/Ns A2849 and A2850.. Deborah L Young
- [STC SB03312CH](https://openairdocs.org/stc/SB03312CH): Replace the Lindstrand Balloons USA Basket with the Lindstrand Balloons Ltd Basket, Part Number BA-244-A-001 with wheelchair side-door accessibility, S/N BA1253.. Love Is In The Air Ballooning, LLC
- [STC SB03066CH](https://openairdocs.org/stc/SB03066CH): Replace the Lindstrand Balloons Basket/Burner/Fuel Tanks with a Aerostar International Basket/Burner/Fuel Tanks.. ARBC Inc dba Lindstrand Balloons USA
- [STC SB03217CH](https://openairdocs.org/stc/SB03217CH): Replace the Lindstrand Balloons Basket/Burner system and fuel tanks. Brad Craig
- [STC SB03213CH](https://openairdocs.org/stc/SB03213CH): Replace the Lindstrand Balloons USA Basket/Burner system and fuel tanks. Chris Reinert
- [STC SB03043CH](https://openairdocs.org/stc/SB03043CH): Replace the Lindstrand Balloons USA Basket/Burner system with the Aerostar International Basket, Part Number 53130, S/N RWSW-AFX-156, and the Aerostar International Burner, Part Number 52350, S/N HP3D-3921. Replace the Lindstrand Balloons USA fuel tanks with the Aerostar International Model Model V-18 Fuel Tank, Part Number 53037, S/Ns  03321 and 03322.  The Aerostar International Basket/Burner is installed via the standard Lindstrand Balloons carabiner (snaplink) attachments.. Dale Wong
- [STC SB02732CH](https://openairdocs.org/stc/SB02732CH): ONLY STC, SN 5363:  Replace the Lindstrand Balloons USA Basket/Burner system with the Aerostar International Basket, Part Number 52131, S/N RWS-602, and the Aerostar International Burner, Part Number 52350, S/N HP3D-3481. Replace the Lindstrand Balloons USA fuel tanks with the Aerostar International fuel tanks, Part Number V-15, S/Ns V94036 and V94045.  The Aerostar International Basket/Burner is installed via the standard Lindstrand Balloons carabiner (snaplink) attachments.. Matthew W. Fenster
- [STC SB02454CH](https://openairdocs.org/stc/SB02454CH): Lindstrand Balloons Ltd Burner system with the Cameron Balloons Double Burner, Part Number CB2702, S/N 0480-0400.. Dale L. Tibodeau
- [STC SB02362CH](https://openairdocs.org/stc/SB02362CH): ONE-ONLY: Replace the Lindstrand Balloons USA Basket/Burner system and fuel tanks.. Isley Todd
- [STC SB02357CH](https://openairdocs.org/stc/SB02357CH): ONE ONLY STC, SN 5347:  Replace the Lindstrand Balloons Basket/Burner system and fuel tanks.. Rainbow Ryders Inc.
- [STC SB02273CH](https://openairdocs.org/stc/SB02273CH): ONE ONLY STC - S/N 5293.  Replace the Lindstrand Balloons USA Basket/Burner system and fuel tanks. Brad Craig
- [STC SB02055CH](https://openairdocs.org/stc/SB02055CH): Limited to installation on serial number 5239 ONLY.. Donner Nicholas R
- [STC SB02056CH](https://openairdocs.org/stc/SB02056CH): Limited to installation on serial number 5180 ONLY.. Donner Nicholas R
- [STC SB02054CH](https://openairdocs.org/stc/SB02054CH): Limited to installation on serial number 5243 ONLY.. Enloe Stuart
- [STC SB01879CH](https://openairdocs.org/stc/SB01879CH): Replace Lindstrand Balloons basket/burner system with the Aerostar International Basket burner system.  Limited to installation on serial number 5137 ONLY.. Smith Warren D
- [STC SB01517CH](https://openairdocs.org/stc/SB01517CH): Replace Lindstrand Balloons basket/burner system with Aerostar basket, s/n CW-3053, and S/N HP3D-3732. Approved for serial number 5146 ONLY. Maximum gross weight is limited to 1650 lbs.. Renner Paul Eric

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.