AC 20-158B

Advisory circular · The Certification of Aircraft Electrical and Electronic Systems for Operation in the High-Intensity Radiated Fields (HIRF) Environment

Approved
May 20, 2024
Last reviewed
August 12, 2026
Cancels
AC20-158A
Family
AC 20-158 · 3 versions
Revision
B
14 CFR parts
23, 25, 27, 29

Guidance, not mandatory unless a rule or AD requires it. DRS record last changed October 23, 2026.

Show pages 28–39

10.13.8 Review the actual system installation in the aircraft and the system configuration used for the integrated system test (see step 5). If significant configuration differences are identified, corrective measures ma y be needed (see step 14).

10.13.9 Certain RF receivers with antennas connected should not be expected to perform without effects during exposure to the HIRF environments, particularly in the RF receiver operating band. Because the definition of adverse effects an d the RF response at portions of the spectrum depends on the RF receiver system function, refer to the individual RF receiver minimum performance standards for additional guidance.

However, because many RF receiver minimum performance standards were prepar ed before implementation of HIRF requirements, the RF receiver pass/fail criteria should be coordinated with the FAA.

10.13.10 You should provide the similarity assessment and supporting rationale to the FAA for approval.

10.14 Step 14 — Corrective Measures.

Take corrective measures if the system fails to satisfy the HIRF immunity assessment of step 13. If changes or modifications to the aircraft, equipment, system, or system installation are required, then additional tests may be necessary to verify the effectiveness of the changes. RTCA/DO -160E, section 20 (as specified in AC 21-16) equipment tests, integrated system tests, and aircraft tests, in whole or in part, may need to be repeated to show HIRF compliance.

10.15 Step 15 — HIRF Protection Compliance .

Submit the test results and compliance report to the cognizant AIR certification branch for approval as part of the overall aircraft type certification or supplemental type certification process.

10.16 Compliance for HCL A Systems on Level 1, 2, 3, and 4 Airplanes Certificated Under Part 23.

Airplane certification levels 1, 2, 3, and 4 are defined in 14 CFR 23.2005 (established by Amendment 23-64). Airplane certification classes I, II, III, and IV are de fined in AC

23.1309-1. The following test levels may be used for HCL A integrated systems on normal category level 1, 2, 3, and 4 airplanes (certification class I, II, III, and IV) .

Equipment testing is acceptable if you show that equipment in the HCL A systems can be operated and tested independently and effectively monitored to verify no adverse effects to the system and function. Otherwise, you should perform integrated system HIRF tests as discussed in step 5 (refer to paragraph 10.5) . The system should comprise all equipment and wiring needed to perform the function. One or more of these systems with redundant channels may perform the same function. When there are multiple systems with redundant channels performing the same function, it is only necessary for one of the multiple systems ’ redundant channels to meet the requirements in § 23.1308(a) or § 23.2520(a). Level 1 airplanes certificated under part 23 meet the same requirements for HIRF as shown in paragraph 10.16.1 below. Level 2 and 3 airplanes certificated under part 23 meet the requirements for HIRF as shown in paragraph 36

10.16.2 below. Level 4 airplanes certified under part 23 meet the requirements for HIRF as shown in paragraph 10.5 (Step 5 - Integrated System Test).

Note: The applicant may also use a means of compliance, which may include ASTM consensus standards, accepted by the Administra tor under § 23.2010. (See paragraph 4.4).

10.16.1 For level 1 airplane HCL A systems, you may perform integrated system conducted and radiated susceptibility tests using RTCA/DO -160E (refer to AC 21-16), section 20, category R.

10.16.2 For level 2 and 3 airplane HCL A systems, you may perform integrated system conducted susceptibility tests per the Generic Conductive Curve — < 25 meters extrapolated to Environment I and using the applicable levels defined in RTCA/DO- 160G (refer to AC 21-16), section 20, category M.

Note: RTCA/DO-160E, section 20, category A is also acceptable.

10.16.3 For level 2 and 3 airplane HCL A systems, you may perform integrated system radiated susceptibility tests per the Aircraft Generic Attenuation Curves applied to Environment I and using the applicable levels described below (RTCA/DO-160G, refer to AC 21-16).

• 0 dB: 100 MHz – 400 MHz (using RTCA/DO-160G, section 20, category G)

• -6 dB: 400 MHz – 1 GHz (using RTCA/DO-160G, section 20, category F)

• -12 dB: 1 GHz – 18 GHz (using RTCA/DO-160G, section 20, category D)

10.16.4 You may design and install the engine control systems using the guidance provided in AC 33.28-3. You may develop and install appropriate electrical bonding features for the engine control systems using the guidance in AC 33.28 -3.

10.16.5 Electrical bonding specifications and verifications should be developed and implemented on the production drawings and ins tructions for continued airworthiness.

11 STEPS TO LEVEL B AND C SYSTEM HIRF COMPLIANCE Steps 1 through 8 listed below for HCL B and C systems HIRF compliance may be used to show compliance with § § 23.1308(b) and (c), 23.2520(b), 25.1317(b) and (c),

27.1317(b) and (c), or § 29.1317(b) and (c).

11.1 Step 1 — System Safety Assessment.

Determine the system failure condition classification for the systems being certified on your aircraft, using a system safety assessment as discussed in paragraph 7.3. For systems classified with hazardous or major failure conditions (level B and C systems), follow compliance steps 2 through 8 listed below, as appropriate. These compliance steps are also depicted in figure 3 of this AC and are not necessarily accomplished sequentially. Systems classified with catastrophic failure conditions (level A systems) should follow the compliance steps outlined in paragraph 10.

11.2 Step 2 — Define Aircraft and System HIRF Protection .

Define the HIRF protection features incorporated into the aircraft and system designs, based on the HIRF test levels applicable to your aircraft and its level B and C systems.

Equipment, system, and aircraft HIRF protection design may occur before you perform aircraft-level tests, and before you determine the actual internal HIRF environment.

Therefore, you should base the equipment, system, and aircraft HIRF protection design on an estimate of the expected internal HIRF environment.

11.3 Step 3 — Select Compliance Method.

Determine if you will perform equipment HIRF tests on the level B and C systems, or if you will base the compliance on previous equipment tests performed for a similar system.

11.4 Step 4 — Equipment Test.

Level B and C systems do not require the sa me degree of HIRF compliance testing as level A systems, and therefore do not require aircraft -level testing. You should follow RTCA/DO-160E, section 20 (as specified in AC 21-16) laboratory test procedures, using the equipment test levels defined in the regulations. The test levels used depend on whether the system is categorized as level B or C. Equipment HIRF test level 1 or 2, as applicable, should be used for level B systems. RTCA/DO-160E, section 20, Category RR, satisfies the requirements of equipment HIRF test level 1. For equipment HIRF test level 2, you may use the approach in paragraph 10.11 of this AC to determine acceptable aircraft transfer function and attenuation curves for your level B system.

Equipment HIRF test level 3 should only be used for level C systems. RTCA/DO-160E, section 20, category TT, satisfies the requirements of equipment HIRF test level 3.

When applying modulated signals, the test levels are given in terms of the peak of the test signal as measured by a root -mean-square (rms) indicating spectrum analyzer's peak detector. See the user’s guide for more details on modulation.

11.4.1 Define appropriate pass/fail criteria for the system, based on the system safety assessment and the appropr iate HIRF regulation (see paragraph 7.3). Any susceptibility noted during the equipment tests, including equipment malfunctions, upset, or damage, should be recorded and evaluated based on the defined pass/fail criteria.

11.5 Step 5 — Similarity Assessment.

11.5.1 The equipment HIRF tests performed for a system previously certified on one aircraft model may be used to show compliance for a similar system. Each system considered for similarity needs to be assessed independently even if it used equipment and installation techniques from a previous certification.

11.5.2 The system used as the basis for certification by similarity must have successfully completed equipment HIRF tests and previously certified for HIRF compliance on another aircraft model. Similarity assessment requires comparison of both equipment and installation differences that could adversely affect HIRF immunity. An assessment of a new system should consider the differences in the equipment circuit interfaces, wiring, grounding, bonding, connecto rs, and wire-shielding practices.

11.5.3 If the assessment finds only minimal differences between the previously certified system and the new system to be certified, similarity may be used for HIRF compliance without the need for additional equipment HIRF tests, provided there are no unresolved in-service HIRF problems related to the previously certified system. If there is uncertainty about the effects of the differences, you should conduct additional tests and analysis as necessary and appropriate to resolve the uncertainty. The amount of additional testing should be commensurate with the degree of difference identified between the new system and the system previously certified. If significant differences are found, similarity should not be used as the basis for HIRF compliance.

11.6 Step 6 — Assess Immunity.

Review the results of the equipment test to determine if the pass/fail criteria are satisfied. HIRF susceptibilities not anticipated or defined in the test plan pass/fail criteria may be observed during equipment HIRF tests. The pass/fail criteria may be modified if the effects neither cause nor contribute to conditions that adversely affect the aircraft functions or systems, as applicable, in the HIRF regulations. You should provide an assessment and supporting rationale for any pass/fail criteria modifications to the FAA for approval. If the HIRF susceptibilities are not acceptable, then corrective measures may be needed (see step 7).

11.6.1 Review the actual system installation in the aircraft and the configuration used for the equipment tests (see step 4). If significant differences in grounding, shielding, connectors, or wiring are identified, corrective measures may be needed (see step 7).

11.6.2 Certain RF receivers with antennas conne cted should not be expected to perform without effects during exposure to the HIRF environments, particularly in the RF receiver operating band. Because the definition of adverse effects and the RF response at particular portions of the spectrum depends on the RF receiver system function, refer to the individual RF receiver minimum performance standards for additional guidance.

However, because many RF receiver minimum performance standards were prepared before implementation of HIRF requirements, the RF re ceiver pass/fail criteria should be coordinated with the FAA. Future modifications of the minimum performance standards should reflect HIRF performance requirements.

11.7 Step 7 — Corrective Measures .

Take corrective measures if the system fails to satisfy the HIRF immunity assessment of step 6. If changes or modifications to the equipment, system, or system installation are needed, then additional tests may be necessary to verify the effectiveness of the changes. The RTCA/DO-160E, section 20 (refer to AC 21-16) equipment tests, in whole or in part, may need to be repeated to show HIRF compliance.

11.8 Step 8 — HIRF Protection Compliance .

Submit the test results and compliance report to the cognizant AIR certification branch for approval as part of the overall aircraft type certification or supplemental type certification process.

12 MAINTENANCE, PROTECTION ASSURANCE, AND MODIFICATIONS

12.1 The minimum maintenance necessary to support HIRF certification must be identified in instructions for continued airworthiness as required by §§ 23.1529, 25.1529, 25.1729,

26.11, 27.1529, or § 29.1529.

12.2 Dedicated devices or specific features may be needed to provide HIRF protection for an equipment or system installation. You should define a ppropriate maintenance procedures for these devices and features to ensure in -service protection integrity. A HIRF protection assurance program may be necessary to verify that the maintenance procedures are adequate. This assurance program may propose a su rveillance program based on a sampling of the fleet for monitoring the effectiveness of the protection features and/or maintenance procedures. The user’s guide provides further information on these topics.

12.3 The maintenance procedures should address the effects of corrosion, fretting, flexing cycles, or other causes that could degrade these HIRF protection devices. Whenever applicable, you should identify specific replacement times of these devices and features.

12.4 Aircraft or system modifications shou ld be assessed for the impact any changes will have on the HIRF protection. You should base this assessment on analysis and/or measurement.

Appendix A Appendix A. Generic Transfer Functions and Attenuatio n A.1 GENERIC TRANSFER FUNCTIONS.

A.1.1 Suitable transfer functions for calculating t he bulk current injection test levels for level A display systems (see paragraph 10.11) are given in figures A -1 through A-5. These are derived generic transfer functions acquired from test results obtained from a significant number of aircraft. The test r esults were processed to establish a 95 percent population probability.

A.1.2 The transfer functions are normalized to a 1 V/m HIRF environment and may be multiplied linearly by the external HIRF environment to establish the bulk current injection test level requirements in the frequency range from 10 kHz up to 400 MHz.

For example, if the HIRF environment is 100 V/m at 3 MHz, then using figure A -1, multiply 0.7 mA/V/m by 100 V/m to establish a test level of 70 milliamperes (mA).

A.1.3 Consult the user’s guide for details on the use of generic transfer functions.

Figure A-1. Generic Transfer Function —Airplane

Note: Generic transfer function normalized to 1 V/m for an airplane with a fuselage length of < 25m.

A-1

Page 46OCROpen in PDF

Appendix A Figure A-2. Generic Transfer Function-Airplane

1.5, 0.7 - 6, 0.7 mA/V/m 0.1 400. 0.15 -

0.01

0.01 0.1 10 100 1000 Frequency - MHz Note: Generic transfer function normalized to 1 V/m for an airplane with a fuselage length of > 25m and ≤ 50m.

Figure A-3 — Generic Transfer Function - Airplane 10

0.5, 2.5 5, 2.5 1 mA/V/m 400, 0.15 50, 0.3

0.1

0.01.

0.01 O.1 10 100 1000 Frequency - MHz Note: Generic transfer function normalized to 1 V/m for an airplane with a fuselage length of > 50m.

A-2

Page 47OCROpen in PDF

Appendix A Figure A-4 Generic Transfer Function - Rotorcraft 10 5, 1.5 30, 1.5 1

• 400, 0.5

0.1

0.01 1

0. 01 0.1 10 100 1000 Frequency - MHz Note: Generic transfer function normalized to 1 V/m for a rotorcraft.

Figure A-5 Generic Transfer Function - All Aircraft 10

0.5, 2.5 5, 2.5 30, 1.5 10, 1.5 400, 0.5

0.1 -

0.01.

0.01 0.1 10 100 1000 Frequency - MHz Note: Generic transfer function normalized to 1 V/m for all aircraft.

A-3

Appendix A A.2 GENERIC ATTENUATION.

A.2.1 Figure A-6 shows the generic attenuation for frequencies from 100 MHz to 18 GHz that can be used for determining the internal HIRF environment where equipment and associated wiring for level A display systems (see paragraph 10.11) are installed. This internal HIRF environment provides the radiated susceptibility test level for the laboratory integrated system test. The external HIRF environment should be divided by the appropriate attenuation, in linear units, to determine the internal HIRF environment.

For example, 12 dB or a 4:1 attenuation means the test level is the applicable external HIRF environment electric field strength reduced by a factor of 4.

A.2.2 Guidance on the use of the generic attenuation is given below:

A.2.2.1 No Attenuation.

No attenuation credit can be used when the level A display equipment and associated wiring are located in aircraft areas with no HIRF shielding, such as areas with unprotected nonconductive composite structures, areas where there is no guarantee of structural bonding, or other open areas where no shielding is provided. You may choose to use no attenuation for equipment that may be installed in a broad r ange of aircraft areas.

A.2.2.2 6 dB Attenuation.

This attenuation is appropriate when the level A display equipment and associated wiring are located in aircraft areas with minimal HIRF shielding, such as a cockpit in a nonconductive composite fuselage with minim al additional shielding, or areas on the wing leading or trailing edges, or in wheel wells.

A.2.2.3 12 dB Attenuation.

This attenuation is appropriate when the level A display equipment and associated wiring are located entirely within aircraft areas with some HIR F shielding, in aircraft with a metal fuselage or a composite fuselage with shielding effectiveness equivalent to metal. Examples of such areas are avionics bays not enclosed by bulkheads, cockpits, and areas near windows, access panels, and doors without EMI gaskets. Currentcarrying conductors in this area, such as hydraulic tubing, control cables, wire bundles, and metal wire trays, are not all electrically bonded to bulkheads they pass through.

A.2.2.4 20 dB Attenuation.

This attenuation is appropriate when the level A display equipment and associated wiring are located entirely within aircraft areas with moderate HIRF shielding, in aircraft with a metal fuselage or a composite fuselage with shielding effectiveness equivalent to metal. In add ition, wire bundles passing through bulkheads in these areas have shields electrically bonded to the bulkheads. Wire bundles are installed close to metal structure and take advantage of other inherent shielding characteristics provided by metal structure. Current-carrying conductors, such as hydraulic tubing, cables, and metal wire trays are electrically bonded to all bulkheads they pass through.

A-4

Appendix A A.2.2.5 32 dB Attenuation.

This attenuation is appropriate when the level A display equipment and all associated wiring to and from equipment are located entirely within areas with very effective HIRF shielding to form an electromagnetic enclosure.

A.2.2.6 Generic Attenuation for Rotorcraft.

Display units installed in rotorcraft typically have minimal attenuation unless specific shielding is provided in the bulkhead, glare shield, panel, and doors.

A.2.3 Different attenuation values may be appropriate for different frequency ranges. For example, 0 dB attenuation may be used for the frequency range of 100 MHz to 400 MHz, 6 dB attenuation for the frequency range of 400 MHz to 1 GHz, and 12 dB attenuation for the frequency range of 1 GHz to 18 GHz. If you intend to use different attenuation values for various frequency ranges, then you should also provide the supporting rationale.

A.2.4 Consult the user’s guide for details on the use of generic attenuation.

A-5

Appendix A A.3 MEASURED TRANSFER FUNCTIONS OR ATTENUATION.

You can produce your own generic transfer functions and attenuation for your level A display systems (see paragraph 10.11) based on actual measurement s on your aircraft models. These transfer functions and attenuation can then be used in your HIRF compliance submission in place of the generic transfer functions and attenuation specified in this appendix. The FAA encourages this approach because it provi des a more accurate reflection of the true internal HIRF environment for your aircraft models.

However, if you intend to produce your own generic transfer functions and attenuation, then this approach should also be addressed in the HIRF compliance plan (s ee paragraph 9.1) that is submitted to the FAA for approval.

Figure A-6 Generic Attenuation Values – All Aircraft 100 MHz to 18 GHz A-6

Appendix B Appendix B. Examples of HIRF Safety Assessment Considerations - Level A Systems on Transport Category Airplanes B.1 EXAMPLES OF HIRF SAFETY ASSESSMENT CONSIDERATIONS .

B.1.1 This appendix contains examples of HIRF safety assessment c onsiderations for level A systems of transport category airplanes. These HIRF safety assessment considerations for level A systems may be applicable to normal category airplanes and rotorcraft .

Establishing appropriate pass/fail criteria for complying with § 25.1317(a) should be achieved through a comprehensive review of the system design using an acceptable HIRF functional hazard assessment process to determine the system’s HCL. The following paragraphs summarize approaches whereby pass /fail criteria for compliance with § 25.1317(a) may depend on the specific system architecture attributes (for example, system with similar redundant channels, dissimilar redundant channels, combination of similar and dissimilar redundant channels) . For evaluation of the examples in paragraph B.1.2 of this appendix, consider the specific system architecture attributes. Channel modes as used in this appendix mean the following:

• Active mode means the channel is performing the aircraft function during normal operation.

• Active-backup mode means the channel is operational (in the ready state), but not used to perform the aircraft function until switched to active mode, either automatically or by flightcrew action.

• Passive-backup mode means the channel is not operational (not in the ready state).

Switching to active mode is either automatic or by flightcrew action upon failure recognition.

Systems are typically categorized with the following archit ectures:

B.1.1.1 Similar Redundant Channels .

The multiple channels consist of equipment, components, electrical interconnections , and configurations that are similar, typically with equipment that have identical part numbers. The channels should be independent. Th ey may be configured in active, active-backup, and passive-backup modes.

B.1.1.2 Dissimilar Redundant Channels .

Each channel is unique (comprises different equipment, components, electrical interconnections, and configurations) and independent of the others. They may be configured in active, active-backup, and passive-backup modes.

B.1.1.3 Combination of Similar and Dissimilar Redundant Channels .

The combination of similar redundant channels and dissimilar redundant channels, as defined above, with independence between channels. They may be configured in active, active-backup, and passive-backup modes.

B-1