b. Guidance.
(1) Paragraph (a). Compliance may be shown by either analysis or demonstration.
(Amendment 25-47)
(2) Paragraph (a). Acceptance of frangible doors. The following test procedure is acceptable to demonstrate that the door between the pilot compartment and the passenger compartment will not block the flight crewmembers' escape in the event the door is jammed. An acceptable means of showing compliance is by demonstrating that the door is frangible and the flightcrew participants can rapidly egress from the pilot compartment without assistance.
(Amendment 25-47)
(i) The test should be conducted in an airplane, or a mockup if the mockup conforms to the production airplane's interior configuration. If a mockup is used, it should include the observer's seat(s), if they are part of the type design, and the bulkhead and door to be tested. The door should be blocked to simulate possible jamming from the top, bottom, and sides (closing and locking alone may not be adequate to simulate all possible jamming). If the fragments from the broken door could cause an obstruction to the escape routes for passenger emergency egress, and if an emergency evacuation demonstration is required by airworthiness regulations or operating rules, consideration should be given to include the passengers in the test.
For emergency evacuation demonstrations with passengers, refer to § 25.803(c), Amendment 25-
15. (Amendment 25-47)
(ii) Two participants representing a pilot in the left crew seat and a copilot in the right crew seat should be used for the test. They should be persons with no special escape abilities. The crewmembers should be a female approximately 60-inches tall and weighing no more than 102 lbs and a male approximately 74-inches tall and weighing no less than 210 lbs.
The foregoing statures and weights represent the 5th percentile female to 95th percentile male occupants respectively. The female participant will be instructed to break the door and be the first person to egress without assistance from the male participant. Instructions for enhancing the egress should be limited to those instructions that will be provided in the FAA-approved Airplane Flight Manual (AFM) or on the related placards. (Amendment 25-47)
(iii) The test should be conducted in night conditions. If conducted in a hangar during the day, the hangar should be draped and taped so that all sunlight is prevented from entering the hangar. Similar conditions should exist if conducted at night either in or out of a hangar. Lighting may be allowed at ground level to aid in leaving the area near the airplane providing the lighting is kept low and shielded so it does not aid evacuating the airplane. Use of emergency lighting is acceptable. (Amendment 25-47)
(iv) Personnel participating should be informed of the purpose of the demonstration and of the safety precautions. Safety of participants is the responsibility of the applicant, and should be considered to prevent injuries to the participants without compromising the test results.
Participants may wear protective gear such as crash helmets, but the protective gear, tools, or any other device should not be used to break through the door. (Amendment 25-47)
44. AMENDMENT 25-72, Effective August 20, 1990.
a. Regulation.
[For an airplane that has a maximum passenger seating configuration of more than 20 seats and that has a lockable door installed between the pilot compartment and the passenger compartment:
(a) The emergency exit configuration must be designed so that neither crewmembers nor passengers need use that door in order to reach the emergency exits provided for them; and
(b) Means must be provided to enable flight crewmembers to directly enter the passenger compartment from the pilot compartment if the cockpit door becomes jammed.]
b. Guidance.
(1) Paragraph (b). Compliance may be shown by either analysis or demonstration.
(Amendment 25-47)
(2) Paragraph (b). Acceptance of frangible doors. The following test procedure is acceptable to demonstrate that the door between the pilot compartment and the passenger compartment will not block the flight crewmembers' escape in the event the door is jammed. An acceptable means of showing compliance is by demonstrating that the door is frangible and the flightcrew participants can rapidly egress from the pilot compartment without assistance.
(Amendment 25-47)
(i) The test should be conducted in an airplane, or a mockup if the mockup conforms to the production airplane's interior configuration. If a mockup is used, it should include the observer's seat(s), if they are part of the type design, and the bulkhead and door to be tested. The door should be blocked to simulate possible jamming from the top, bottom, and sides (closing and locking alone may not be adequate to simulate all possible jamming). If the fragments from the broken door could cause an obstruction to the escape routes for passenger emergency egress, and if an emergency evacuation demonstration is required by airworthiness regulations or operating rules, consideration should be given to include the passengers in the test.
For emergency evacuation demonstrations with passengers, refer to § 25.803(c), Amendment 25-
15. (Amendment 25-47)
(ii) Two participants representing a pilot in the left crew seat and a copilot in the right crew seat should be used for the test. They should be persons with no special escape abilities. The crewmembers should be a female approximately 60-inches tall and weighing no more than 102 lbs and a male approximately 74-inches tall and weighing no less than 210 lbs.
The foregoing statures and weights represent the 5th percentile female to 95th percentile male occupants respectively. The female participant will be instructed to break the door and be the first person to egress without assistance from the male participant. Instructions for enhancing the
16 egress should be limited to those instructions that will be provided in the FAA-approved Airplane Flight Manual (AFM) or on the related placards. (Amendment 25-47)
(iii) The test should be conducted in night conditions. If conducted in a hangar during the day, the hangar should be draped and taped so that all sunlight is prevented from entering the hangar. Similar conditions should exist if conducted at night either in or out of a hangar. Lighting may be allowed at ground level to aid in leaving the area near the airplane providing the lighting is kept low and shielded so it does not aid evacuating the airplane. Use of emergency lighting is acceptable. (Amendment 25-47)
(iv) Personnel participating should be informed of the purpose of the demonstration and of the safety precautions. Safety of participants is the responsibility of the applicant, and should be considered to prevent injuries to the participants without compromising the test results.
Participants may wear protective gear such as crash helmets, but the protective gear, tools, or any other device should not be used to break through the door. (Amendment 25-47)
45. AMENDMENT 25-106, Effective January 15, 2002.
a. Regulation.
For an airplane that has a [lockable door installed between the pilot compartment and the passenger compartment:
(a) For airplanes with a maximum passenger seating configuration of more than 20 seats, the emergency exit configuration must be designed so that neither crewmembers nor passengers require use of the flightdeck door in order to reach the emergency exits provided for them;]
(b) Means must be provided to enable flight crewmembers to directly enter the passenger compartment from the pilot compartment if the cockpit door becomes jammed.
[(c) There must be an emergency means to enable a flight attendant to enter the pilot compartment in the event that the flightcrew becomes incapacitated.]
b. Guidance.
(1) Paragraph (b). Compliance may be shown by either analysis or demonstration.
(Amendment 25-47)
(2) Paragraph (b). Acceptance of frangible doors. The following test procedure is acceptable to demonstrate that the door between the pilot compartment and the passenger compartment will not block the flight crewmembers' escape in the event the door is jammed. An acceptable means of showing compliance is by demonstrating that the door is frangible and the
17 flightcrew participants can rapidly egress from the pilot compartment without assistance.
(Amendment 25-47)
(i) The test should be conducted in an airplane, or a mockup if the mockup conforms to the production airplane's interior configuration. If a mockup is used, it should include the observer's seat(s), if they are part of the type design, and the bulkhead and door to be tested. The door should be blocked to simulate possible jamming from the top, bottom, and sides (closing and locking alone may not be adequate to simulate all possible jamming). If the fragments from the broken door could cause an obstruction to the escape routes for passenger emergency egress, and if an emergency evacuation demonstration is required by airworthiness regulations or operating rules, consideration should be given to include the passengers in the test.
For emergency evacuation demonstrations with passengers, refer to § 25.803(c), Amendment 25-
15. (Amendment 25-47)
(ii) Two participants representing a pilot in the left crew seat and a copilot in the right crew seat should be used for the test. They should be persons with no special escape abilities. The crewmembers should be a female approximately 60-inches tall and weighing no more than 102 lbs and a male approximately 74-inches tall and weighing no less than 210 lbs.
The foregoing statures and weights represent the 5th percentile female to 95th percentile male occupants respectively. The female participant will be instructed to break the door and be the first person to egress without assistance from the male participant. Instructions for enhancing the egress should be limited to those instructions that will be provided in the FAA-approved Airplane Flight Manual (AFM) or on the related placards. (Amendment 25-47)
(iii) The test should be conducted in night conditions. If conducted in a hangar during the day, the hangar should be draped and taped so that all sunlight is prevented from entering the hangar. Similar conditions should exist if conducted at night either in or out of a hangar. Lighting may be allowed at ground level to aid in leaving the area near the airplane providing the lighting is kept low and shielded so it does not aid evacuating the airplane. Use of emergency lighting is acceptable. (Amendment 25-47)
(iv) Personnel participating should be informed of the purpose of the demonstration and of the safety precautions. Safety of participants is the responsibility of the applicant, and should be considered to prevent injuries to the participants without compromising the test results.
Participants may wear protective gear such as crash helmets, but the protective gear, tools, or any other device should not be used to break through the door. (Amendment 25-47)
(3) Paragraph (c). Refer to Appendix 11, FAA Memorandum, 01-115-11, Original Release: dated November 6, 2001, Revised December 3, 2002, “Subject: Certification of Strengthened Flightdeck Doors on Transport Category Airplanes.” This policy memorandum outlines acceptable means of compliance with this paragraph and many other regulatory requirements that were affected by Amendment 25-106. (Amendment 25-106) 46 - 60. [RESERVED]
THIS PAGE INTENTIONALLY LEFT BLANK
19 SECTION 25.783 DOORS
61. REGULATION IN EFFECT AT ADOPTION OF PART 25.
a. Regulation.
(a) Each cabin must have at least one easily accessible external door.
(b) There must be a means to lock and safeguard each external door against opening in flight (either inadvertently by persons or as a result of mechanical failure). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the airplane. Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even in darkness. Auxiliary locking devices may be used.
(c) Each external door must be reasonably free from jamming as a result of fuselage deformation in a minor crash.
(d) Each external door must be located where persons using them will not be endangered by the propellers when appropriate operating procedures are used.
(e) There must be a provision for direct visual inspection of the locking mechanism by crewmembers to determine whether external doors, for which the initial opening movement is outward (including passenger, crew, service, and cargo doors), are fully locked. In addition, there must be a visual means to signal to appropriate crewmembers when normally used external doors are closed and fully locked.
(f) Cargo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e) of this section and be safeguarded against opening in flight as a result of mechanical failure.
b. Guidance.
(l) Paragraphs (b) through (e). The requirements of these paragraphs apply to all cabin and pilot compartment external doors usable for entrance or egress. It is not restricted to the main cabin door. Cargo and service doors not suitable for emergency egress need only comply with § 25.783(e) and be safeguarded against opening in flight as a result of mechanical failure.
(Amendment 25-0)
(2) Paragraph (b). Auxiliary locking devices. (Amendment 25-0)
(i) The use of auxiliary locking devices is permitted. Such devices would include dual locking handles, other types of locking and safety devices, two position handles, and dual operation handles (where one operation such as pushing or pulling on the handle unlocks the latching mechanism and the second operation of turning the handle unlatches the door for opening). Auxiliary locking devices should be used only as an additional safety factor and should not be used as a means of correcting an inadequate design of the primary locking or latching means. The advantages to be gained from the installation of auxiliary or dual locking devices (safety chains and dual handle main locking means) should be weighed against the need to easily and rapidly open the door in case of emergencies so that the overall level of safety is as high as practicable. (Amendment 25-0)
(ii) All locking or safety means, including safety chains and latches of any kind, should be so positioned and designed that their presence, location and means of operation are obvious to one not familiar with door designs. (Amendment 25-0) (A) The means of fastening safety devices should be sufficiently simple to make removal easy. (Amendment 25-0) (B) Any emergency release mechanism installed to release the safety device should operate with a simple motion and upon the application of relatively small forces.
(Amendment 25-0) (C) All locking devices should be readily operable from both inside and outside of the airplane and be appropriately marked both inside and outside. (Amendment 25-0)
(iii) Auxiliary safety devices meeting the standards of paragraph (ii) above may be fastened in place during the entire flight. It will not be necessary to have such devices unlatched during takeoff and landing. Auxiliary safety devices such as safety chains or bars that do not meet the standards of paragraph (ii) above may be used provided operating instructions are installed at or near the device and a placard is installed requiring the removal of such devices prior to takeoff and landing. For related guidance, Refer to paragraph 351b(3). (Amendment 25-
0)
(3) Paragraph (b). Power operated external doors. Power operated doors should be so designed that the door can be opened by manual means even when power is inactivated. The loss of power should not cause the door to become unlatched. Since emergency landings, such as the wheels-up condition, may result in the severance of electrical wires or rupture of hydraulic and pneumatic lines, the power which may be needed for operation of the doors or exits may be lost. Similarly, it is conceivable that under emergency conditions, the electrical power source may be purposely interrupted to reduce the possibility of fire. (Amendment 25-0)
(4) Paragraphs (b) and (e). Means for safeguarding against inadvertent opening in flight. Auxiliary locking devices may be used to reduce the probability of inadvertent opening in flight provided they meet the standards and conditions covered above. (Amendment 25-0)
(i) It is acceptable to create a limited access zone in front of the door to eliminate the possibility of a passenger using the door handle as a steadying means and thereby inadvertently opening the door. Although providing a restricted zone by means of a barrier may appear to conflict with the requirements of § 25.813 for an unobstructed passageway to Type I, and Type II emergency exits, it is considered that it would contribute sufficiently to the overall safety of the airplane occupants to be permitted. This device may be a rope, chain, rigid bar or gate. Such installations should be waist high to provide the maximum benefits for an adult and the end fastenings should be simple to make removal easy. It is not considered acceptable to install full-length auxiliary doors, but waist-high rigid gates would be acceptable provided they open toward the door and will not block the opening of the cabin door in any way. The locking means should be one, which could be easily overridden such as a spring-loaded ball type latch.
(Amendment 25-0)
(ii) Flexible gates such as those made from webbing are not acceptable on the basis that persons may become entangled during an emergency egress. The use of a barrier to prevent persons from inadvertently opening the door in flight does not eliminate the need for a safety means to provide for possible malfunctioning of the primary locking mechanism; however, the auxiliary safety means covered above may eliminate the need for a restricted zone. (Amendment 25-0)
(5) Paragraph (e). Direct visual inspection. The means of complying with paragraph
(e) of this section will depend upon the type of door and locking mechanism used. In all cases there should be provisions to ascertain that an unsatisfactory condition does not exist after closing the door. In some instances a central window for viewing the position of the mechanism may be sufficient while other cases may require one or more windows in the door frame to permit inspection of the bayonet location relative to that portion of the lock in the door frame.
The need for or the number and location of inspection openings or windows will depend on the type of door and locking mechanism used. (Amendment 25-0)
(6) Paragraph (e). Visual indicating system. The objective herein is to be able to ascertain by visual means that the door or locking means is sufficiently engaged to eliminate hazards emanating from an improperly closed door. Outward opening doors present a different problem from inward opening doors. (Amendment 25-0)
(i) The visual indicating system may consist of an indicator for each individual door, or a system connecting all doors in series. If the latter system is used, it need not necessarily show which door is not fully locked. (Amendment 25-0)
(ii) It is not necessary that more than one crewmember be able to ascertain by a visual signal that all external doors, normally used by the crew in supplying the airplane, or in loading and unloading passengers and cargo, are fully closed and locked. The visual signal should be located so that it may easily be seen by the appropriate crewmember from his station.
(Amendment 25-0)
62. AMENDMENT 25-15, Effective October 24, 1967.
a. Regulation.
(a) Each cabin must have at least one easily accessible external door.
(b) There must be a means to lock and safeguard each external door against opening in flight (either inadvertently by persons or as a result of mechanical failure). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the airplane. Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even in darkness. Auxiliary locking devices may be used.
(c) Each external door must be reasonably free from jamming as a result of fuselage deformation in a minor crash.
(d) Each external door must be located where persons using them will not be endangered by the propellers when appropriate operating procedures are used.
(e) There must be a provision for direct visual inspection of the locking mechanism by crewmembers to determine whether external doors, for which the initial opening movement is outward (including passenger, crew, service, and cargo doors), are fully locked. In addition, there must be a visual means to signal to appropriate crewmembers when normally used external doors are closed and fully locked.
(f) Cargo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e) of this section and be safeguarded against opening in flight as a result of mechanical failure.
[(g) Each passenger entry door in the side of the fuselage must qualify as a Type A, Type I, or Type II passenger emergency exit and must meet the requirements of §§ 25.807 through 25.813 that apply to that type of passenger emergency exit. If an integral stair is installed at such a passenger entry door, the stair must be designed so that when subjected to the inertia forces specified in § 25.561, and following the collapse of one or more legs of the landing gear, it will not interfere to an extent that will reduce the effectiveness of emergency egress through the passenger entry door.]
b. Guidance.
(l) Paragraphs (b) through (e). The requirements of these paragraphs apply to all cabin and pilot compartment external doors usable for entrance or egress. It is not restricted to the
23 main cabin door. Cargo and service doors not suitable for emergency egress need only comply with § 25.783(e) and be safeguarded against opening in flight as a result of mechanical failure.
(Amendment 25-0)
(2) Paragraph (b). Auxiliary locking devices. (Amendment 25-0)
(i) The use of auxiliary locking devices is permitted. Such devices would include dual locking handles, other types of locking and safety devices, two position handles, and dual operation handles (where one operation such as pushing or pulling on the handle unlocks the latching mechanism and the second operation of turning the handle unlatches the door for opening). Auxiliary locking devices should be used only as an additional safety factor and should not be used as a means of correcting an inadequate design of the primary locking or latching means. The advantages to be gained from the installation of auxiliary or dual locking devices (safety chains and dual handle main locking means) should be weighed against the need to easily and rapidly open the door in case of emergencies so that the overall level of safety is as high as practicable. (Amendment 25-0)
(ii) All locking or safety means, including safety chains and latches of any kind, should be so positioned and designed that their presence, location and means of operation are obvious to one not familiar with door designs. (Amendment 25-0) (A) The means of fastening safety devices should be sufficiently simple to make removal easy. (Amendment 25-0) (B) Any emergency release mechanism installed to release the safety device should operate with a simple motion and upon the application of relatively small forces.
(Amendment 25-0) (C) All locking devices should be readily operable from both inside and outside of the airplane and be appropriately marked both inside and outside. (Amendment 25-0)
(iii) Auxiliary safety devices meeting the standards of paragraph (ii) above may be fastened in place during the entire flight. It will not be necessary to have such devices unlatched during takeoff and landing. Auxiliary safety devices such as safety chains or bars that do not meet the standards of paragraph (ii) above may be used provided operating instructions are installed at or near the device and a placard is installed requiring the removal of such devices prior to takeoff and landing. For related guidance, Refer to paragraph 351b(3). (Amendment 25-
0)
(3) Paragraph (b). Power operated external doors. Power operated doors should be so designed that the door can be opened by manual means even when power is inactivated. The loss of power should not cause the door to become unlatched. Since emergency landings, such as the wheels-up condition, may result in the severance of electrical wires or rupture of hydraulic and pneumatic lines, the power which may be needed for operation of the doors or exits may be lost. Similarly, it is conceivable that under emergency conditions, the electrical power source may be purposely interrupted to reduce the possibility of fire. (Amendment 25-0)
(4) Paragraphs (b) and (e). Means for safeguarding against inadvertent opening in flight. Auxiliary locking devices may be used to reduce the probability of inadvertent opening in flight provided they meet the standards and conditions covered above. (Amendment 25-0)
(i) It is acceptable to create a limited access zone in front of the door to eliminate the possibility of a passenger using the door handle as a steadying means and thereby inadvertently opening the door. Although providing a restricted zone by means of a barrier may appear to conflict with the requirements of § 25.813 for an unobstructed passageway to Type I, and Type II emergency exits, it is considered that it would contribute sufficiently to the overall safety of the airplane occupants to be permitted. This device may be a rope, chain, rigid bar or gate. Such installations should be waist high to provide the maximum benefits for an adult and the end fastenings should be simple to make removal easy. It is not considered acceptable to install full-length auxiliary doors, but waist-high rigid gates would be acceptable provided they open toward the door and will not block the opening of the cabin door in any way. The locking means should be one, which could be easily overridden such as a spring-loaded ball type latch.
(Amendment 25-0)
(ii) Flexible gates such as those made from webbing are not acceptable on the basis that persons may become entangled during an emergency egress. The use of a barrier to prevent persons from inadvertently opening the door in flight does not eliminate the need for a safety means to provide for possible malfunctioning of the primary locking mechanism; however, the auxiliary safety means covered above may eliminate the need for a restricted zone. (Amendment 25-0)
(5) Paragraph (e). Direct visual inspection. The means of complying with paragraph
(e) of this section will depend upon the type of door and locking mechanism used. In all cases there should be provisions to ascertain that an unsatisfactory condition does not exist after closing the door. In some instances a central window for viewing the position of the mechanism may be sufficient while other cases may require one or more windows in the door frame to permit inspection of the bayonet location relative to that portion of the lock in the door frame.
The need for or the number and location of inspection openings or windows will depend on the type of door and locking mechanism used. (Amendment 25-0)
(6) Paragraph (e). Visual indicating system. The objective herein is to be able to ascertain by visual means that the door or locking means is sufficiently engaged to eliminate hazards emanating from an improperly closed door. Outward opening doors present a different problem from inward opening doors. (Amendment 25-0)
(i) The visual indicating system may consist of an indicator for each individual door, or a system connecting all doors in series. If the latter system is used, it need not necessarily show which door is not fully locked. (Amendment 25-0)
(ii) It is not necessary that more than one crewmember be able to ascertain by a visual signal that all external doors, normally used by the crew in supplying the airplane, or in
25 loading and unloading passengers and cargo, are fully closed and locked. The visual signal should be located so that it may easily be seen by the appropriate crewmember from his station.
(Amendment 25-0)
63. AMENDMENT 25-23, Effective May 8, 1970.
a. Regulation.
(a) Each cabin must have at least one easily accessible external door.
(b) There must be a means to lock and safeguard each external door against opening in flight (either inadvertently by persons or as a result of mechanical failure [or failure of a single structural element]). Each external door must be openable from both the inside and the outside, even though persons may be crowded against the door on the inside of the airplane. Inward opening doors may be used if there are means to prevent occupants from crowding against the door to an extent that would interfere with the opening of the door. The means of opening must be simple and obvious and must be arranged and marked so that it can be readily located and operated, even in darkness. Auxiliary locking devices may be used.
(c) Each external door must be reasonably free from jamming as a result of fuselage deformation in a minor crash.
(d) Each external door must be located where persons using them will not be endangered by the propellers when appropriate operating procedures are used.
(e) There must be a provision for direct visual inspection of the locking mechanism by crewmembers to determine whether external doors, for which the initial opening movement is outward (including passenger, crew, service, and cargo doors), are fully locked. In addition, there must be a visual means to signal to appropriate crewmembers when normally used external doors are closed and fully locked.
(f) Cargo and service doors not suitable for use as an exit in an emergency need only meet paragraph (e) of this section and be safeguarded against opening in flight as a result of mechanical failure [or failure of a single structural element].
(g) Each passenger entry door in the side of the fuselage must qualify as a Type A, Type I, or Type II passenger emergency exit and must meet the requirements of §§ 25.807 through 25.813 that apply to that type of passenger emergency exit. If an integral stair is installed at such a passenger entry door, the stair must be designed so that when subjected to the inertia forces specified in § 25.561, and following the collapse of one or more legs of the landing gear, it will not interfere to an extent that will reduce the effectiveness of emergency egress through the passenger entry door.