AC 25-17A

Advisory circular · Transport Airplane Cabin Interiors Crashworthiness Handbook

Show pages 726–737
Page 738OCROpen in PDF

Top 115 150 . Mask 156 (Unless denoted otherwise, all dimensions are in millimeters.)

[Figure 2A. "Globar" Radiant Panel] 722

Page 739OCROpen in PDF

TOP T -25- 115 • Reflector, adjust slope, top and bottom, for uniform heat flux on sample.

- Mask

- 1/4" - 20 Machine Screw 75 g (Unless denoted otherwise al dimensions are in millmeters.)

[Figure 2B. "Globar" Radiant Panel] 723

Page 740OCROpen in PDF

SPRING 2 Radlus Flange, 1" Frami "3/8" 156 .020 ANGLE IRON Stainless RETAINER FRAME Steel Wire 165 24 ga Steel

SAMPLE HOLDER Washer 50mm OD 13mm ID Weld her 50mm OD 13mm ID Screw Drill & \Tap for Weld 10-32 Machine Screw 1/2 - 13 nut 1/2" Nut to Washer 2 Radlus, 5 Flange 165

MOUNTING BRACKET (Unless denoted otherwise, all dimensions are in millimeters.)

[Figure 3.] 724

Page 741OCROpen in PDF

- 125mm → 25

- 25 — No. 32 Drill Hole

- 9.5 O.D.

9.5 Tubing Leak-Free Seal on 6.35 Pilot Tubing (Unless denoted otherwise, all dimensions are in millimeters.)

[Figure 4.] 725

Page 742Open in PDF

1181 – 1185. [RESERVED]

Page 743Open in PDF

727 1186. APPENDIX F, PART V, DID NOT EXIST PRIOR TO AMENDMENT 25-66.

1187. APPENDIX F, AMENDMENT 25-66, Effective September 26, 1988.

PART V - TEST METHOD TO DETERMINE THE SMOKE EMISSION

CHARACTERISTICS OF CABIN MATERIALS

(a) Summary of Method. The specimens must be constructed, conditioned, and tested in the flaming mode in accordance with American Society of Testing and Materials (ASTM) Standard Test Method ASTM F81483.

(b) Acceptance Criteria. The specific optical smoke density (DS), which is obtained by averaging the reading obtained after 4 minutes with each of the three specimens, shall not exceed 200 1188 – 1192. [RESERVED]

Page 744Open in PDF

THIS PAGE INTENTIONALLY LEFT BLANK

Page 745Open in PDF

729 1193. APPENDIX F, PART VI, DID NOT EXIST PRIOR TO AMENDMENT 25-111.

1194. APPENDIX F, AMENDMENT 25-111, Effective September 2, 2003. This amendment revised Part I and added Parts VI and VII.

[PART VI-TEST METHOD TO DETERMINE THE FLAMMABILITY AND FLAME

PROPAGATION CHARACTERISTICS OF THERMAL/ACOUSTIC INSULATION MATERIALS] [Use this test method to evaluate the flammability and flame propagation characteristics of thermal/acoustic insulation when exposed to both a radiant heat source and a flame.

(a) Definitions.

"Flame propagation" means the furthest distance of the propagation of visible flame towards the far end of the test specimen, measured from the midpoint of the ignition source flame. Measure this distance after initially applying the ignition source and before all flame on the test specimen is extinguished. The measurement is not a determination of burn length made after the test.

"Radiant heat source" means an electric or air propane panel.

"Thermal/acoustic insulation" means a material or system of materials used to provide thermal and/or acoustic protection. Examples include fiberglass or other batting material encapsulated by a film covering and foams.

"Zero point" means the point of application of the pilot burner to the test specimen.

(b) Test apparatus.

Page 746Open in PDF

(1) Radiant panel test chamber. Conduct tests in a radiant panel test chamber (see figure 1 above). Place the test chamber under an exhaust hood to facilitate clearing the chamber of smoke after each test. The radiant panel test chamber must be an enclosure 55-inches (1397 mm) long by 19.5 (495 mm) deep by 28 (710 mm) to 30-inches (maximum) (762 mm) above the test specimen. Insulate the sides, ends, and top with a fibrous ceramic insulation, such as Kaowool MTM board. On the front side, provide a 52 by 12 inches (1321 by 305 mm) draftfree, high-temperature, glass window for viewing the sample during testing. Place a door below the window to provide access to the movable specimen platform holder. The bottom of the test chamber must be a sliding steel platform that has provision for securing the test specimen holder in a fixed and level position. The chamber must have an internal chimney with exterior dimensions of 5.1-inches (129 mm) wide, by 16.2-inches (411 mm) deep by 13- inches (330 mm) high at the opposite end of the chamber from the radiant energy source. The interior dimensions must be 4.5-inches (114 mm) wide by 15.6-inches (395 mm) deep. The chimney must extend to the top of the chamber (see figure 2).

Page 747OCROpen in PDF

½ in. (13 mm) Kaowool M board 16 gauge (1/16 in. 1.6mm) aluminum sheet metal 1/8 in. (3.2 mm) angle iron 15 9/16 In (394 mm) (114 mm) 4 ½ in 13 in.

(330 mm) 5 1/8 in.

(130 mm) 16 3/16 in.

(411 mm) Figure 2 - Internal Chimney

(2) Radiant heat source. Mount the radiant heat energy source in a cast iron frame or equivalent. An electric panel must have six, 3--inch wide emitter strips. The emitter strips must be perpendicular to the length of the panel. The panel must have a radiation surface of 12-7/8 by 18-1/2 -inches (327 by 470 mm). The panel must be capable of operating at temperatures up to 1300 degree F (704 degree C). An air propane panel must be made of a porous refractory material and have a radiation surface of 12 by 18-inches (305 by 457 mm).

Page 748Open in PDF

732 The panel must be capable of operating at temperatures up to 1,500 degree F (816 degree C). See figures 3a and 3b.

Page 749Open in PDF

(i) Electric radiant panel. The radiant panel must be 3-phase and operate at 208 volts. A single-phase, 240 volt panel is also acceptable. Use a solid-state power controller and microprocessor- based controller to set the electric panel operating parameters.

(ii) Gas radiant panel. Use propane (liquid petroleum gas-2.1 UN 1075) for the radiant panel fuel. The panel fuel system must consist of a venturi-type aspirator for mixing gas and air at approximately atmospheric pressure. Provide suitable instrumentation for monitoring and controlling the flow of fuel and air to the panel. Include an air flow gauge, an air flow regulator, and a gas pressure gauge.

(iii) Radiant panel placement. Mount the panel in the chamber at 30 degree to the horizontal specimen plane, and 7-1/2-inches above the zero point of the specimen.

(3) Specimen holding system.

(i) The sliding platform serves as the housing for test specimen placement. Brackets may be attached (via wing nuts) to the top lip of the platform in order to accommodate various