770 Figure 7. NO STOWAGE The circle-slash should be red and override the suitcase. The suitcase should be black and the background white.
Figure 8. LIFE RAFT The life raft should be red, the person and wave black.
Figure 9. OXYGEN The bottle and printing should be green and the background white.
771 Figure 10. MEGAPHONE The megaphone should be red and the background white.
THIS PAGE INTENTIONALLY LEFT BLANK
773 APPENDIX 3
CRASHWORTHINESS ADVISORY CIRCULARS
1. 20-33B “Technical Information Regarding Civil Aeronautics Manuals 1, 3, 4a, 4b, 5, 6, 7, 8, 9, 13, and 14” (5/1/75).
2. 20-36T “Index of Articles (Materials, Parts, Processes and Appliances) Certified Under the Technical Standard Order System” (10/1/97).
3. 20-38A “Measurement of Cabin Interior Emergency Illumination in Transport Airplanes” (2/8/66).
4. 20-41A “Substitute Technical Standard Order (TSO) Aircraft Equipment” (4/5/77).
5. 20-42C “Hand Fire Extinguishers for Use in Aircraft” (3/7/84).
6. 20-47 “Exterior Colored Band Around Exits on Transport Airplanes” (2/8/66).
7. 20-56A “Marking of TSO-C72b Individual Flotation Devices” (4/1/75).
8. 20-60 “Accessibility to Excess Emergency Exits” (7/18/68).
9. 20-90C “Directory of Engineering and Manufacturing District Offices” (4/30/81).
10. 20-110L “Index of Aviation Technical Standard Orders” (10/10/2000).
11. 20-118A “Emergency Evacuation Demonstration From Small Airplanes” (3/9/87).
12. 20-146 “Methodology for Dynamic Seat Certification by Analysis for use in Parts 23, 25, 27, and 29 Airplanes and Rotorcraft” (5/19/2003).
13. 21-22 “Injury Criteria for Human Exposure to Impact” (6/20/85).
14. 21-25A, “Approval of Modified Seating Systems Initially Approved Under a Technical Standard Order” (6/3/97).
15. 21-34 “Shoulder Harness-Safety Belt Installations” (6/4/93).
16. 23-2A “Flammability Tests” (5/11/2007). *
17. 23-17A “System and Equipment Guide for Certification of Part 23 Airplanes” (6/27/02). *
18. 25-5 “Installation Approval on Transport Category Airplanes of Cargo Unit Load Devices Approved as Meeting the Criteria in NAS 3610” (6/3/1970).
19. 25-9A “Smoke Detection, Penetration, and Evacuation Tests, and Related Flight Manual Emergency Procedures” (1/6/94).
20. 25-10 “Guidance for Installation of Miscellaneous, Nonrequired Electrical Equipment” (3/6/87).
21. 25-16 “Electrical Fault and Fire Prevention and Protection” (9/25/1987).
22. 25-18 “Transport Category Airplanes Modified for Cargo Service” (1/6/94).
23. 25.562-1B “Dynamic Evaluation of Seat Restraint Systems & Occupant Protection on Transport Airplanes” (1/10/06).
24. 25.783-1 “Fuselage Doors, Hatches and Exits” (12/10/86).
25. 25.785-1A “Flight Attendant Seat and Torso Restraint System Installations” (1/6/94).
26. 25.795-1A “Flightdeck Intrusion resistance” (10/24/2008).
27. 25.795-2A “Flightdeck Penetration Resistance” (10/24/2008).
28. 25.803-1 “Emergency Evacuation Demonstrations” (11/13/89).
29. 25.807-1 “Uniform Distribution of Exits” (8/13/90).
30. 25.812-1A “Floor Proximity Emergency Escape Path Marking” (5/22/89).
31. 25.812-2, “Floor Proximity Emergency Escape Path Marking Systems Incorporating Photoluminescent Elements” (7/24/97).
32. 25.853-1 “Flammability Requirements for Aircraft Seat Cushions” (9/17/86).
33. 25.856-1 “Thermal/Acoustic insulation flame propagation test method details” (6/24/05)
34. 25.856-2A “Installation of thermal/acoustic insulation for burnthrough protection” (7/29/2008)
35. 27-1A “Certification of Normal Category Rotorcraft” (7/30/97).
36. 29-2B “Certification of Transport Category Rotorcraft” (7/30/97).
37. 43.13-1A “Acceptable Methods, Techniques and Practices-Aircraft Inspection and Repair” (4/17/72).
38. 43.13-2A “Acceptable Methods, Techniques and Practices-Aircraft Alterations” (6/9/77).
39. 43.13-2A “Change 2” (10/30/89).
40. 91-8B “Use of Oxygen by Aviation Pilots/Passengers” (4/7/82).
41. 103-4 “Hazard Associated with Sublimation of Solid Carbon Dioxide (Dry Ice) Aboard Aircraft” (5/1/74).
42. 120-38 “Transport Category Airplanes Cabin Ozone Concentrations” (10/10/80).
43. 120-47 “Survival Equipment for Use in Overwater Operations” (6/12/87).
44. 121-24A “Passenger Safety Information Briefing and Briefing Cards” (5/9/89).
* Not directly applicable to part 25 airplanes.
THIS PAGE INTENTIONALLY LEFT BLANK
777 APPENDIX 4
TEST PROCEDURES FOR EVALUATING NONSTANDARD EXITS
FOR TRANSPORT CATEGORY AIRPLANES
1. Where it is necessary to determine the acceptability of a non-standard exit arrangement for which an applicant has requested an exemption from the applicable 14 CFR, full scale testing should be employed using representative subjects under conditions such that accurate comparisons may be made.
2. PURPOSE OF THE TEST. The purpose of the test is to determine that the mean escape time using the proposed exit configuration is equal to or better than the time required to use an exit configuration defined by pertinent CFRS applying to Transport Category Airplanes. The results can be used to substantiate equivalency for an exemption or an equivalent level of safety determination. This test procedure should not be used for determining the rating of an exit or exit configuration, since it is not extensive enough for such a determination.
3. EXPERIMENTAL CONDITIONS.
a. Direct comparisons are to be made between escape time using the proposed exit or exits and corresponding acceptable arrangements. A proposed exit arrangement may be one or more openings not conforming in all respects to applicable CFR's which would, if approved, replace such opening or openings specified in the regulations.
b. A mockup of a section of the fuselage may be used such that arrangement of exit, passenger seats, step-up distance from cabin floor to exit sill and step-down distance from sill to wing or step simulate those proposed for the airplane. If high-density seating is to be used, the minimum distance between the seats should be simulated. Where over-the-wing exits are being tested and the step-down distances of two or more proposed exits differ, either the greater step-down distance should be used, or the several proposed exits should be simultaneously compared with the conventional arrangement they are designed to replace. In the case of floor level exits which are not located over the wing, or Type III and Type IV exits which are not located over the wing, or overwing exits which are at a greater distance than is specified in the CFR, the step, or descent device, shall simulate those designed for operational use and the device or conditions of use shall be fully described, including details of the dimensions. If production devices are available, they should be used.
c. At the start of each trial, subjects may either be seated with belts fastened or may be standing in line, whichever is more convenient, provided that the procedure is maintained consistently for each trial included in the test.
d. Subjects should not be permitted any trials prior to the test, but may be briefed as to the method of escape. The context of the briefing should be reported. Examples of briefing to ensure rapid egress in escaping through window exits would be the instruction to pass through one foot first, then head and body, then the other foot, i.e., "foot first, then head." Examples of instructions for escaping through a door via an escape slide are: "Jump into slide," "Do not hold on," "Keep sitting position."
4. STATISTICAL DESIGN.
a. As many subjects should be used as time, funds, and facilities permit. As a minimum, the number of persons in each group should be approximately 1/2 the exit rating specified for the standard exit in § 25.807(c)(4), but no less than 25.
b. The subjects should be assigned to a number of subgroups equal to or a multiple of, the number of configurations to be tested, including the standard. As noted above, the number of subjects in each subgroup should be at least 25.
c. The subgroups should be as nearly alike as possible with respect to physical agility, age, sex, weight, and the like. This can be achieved by first stratifying the total set of subjects by age and sex and then subdividing each age-sex group at random into the required number of subgroups. The age-sex distribution in each subgroup need not be that stated in § 25.803(c)(8)(i), (ii), and (iii). The subjects should range in age from approximately 20 to 60 years of age with approximately 30 percent of the subjects being female. The dolls of § 25.803(c)(8)(iv) need not be included.
d. Each subgroup should test each configuration, but the order of trials should be different for each subgroup and should be chosen in accordance with the principle of the Latin Square. The principle of the Latin Square is that each configuration be tried once by each group and appear once in each possible order. Thus if there are two arrangements to be tested, and therefore, two subgroups labeled A and B, say, then group A should try first the standard then alternative arrangement, Group B should make trials in the reverse order. For the case of three configurations, group A might try first the standard, then the first alternative and last the second alternative; group B would try the first alternative, second alternative and standard, in that order;
and group C would first try the second alternative, then the standard and lastly, the first alternative. The arrangement eliminates the effects of individual participants learning, fatigue and agility.
5. RECORD OF RESULTS.
a. Motion picture records of the trials should be made.
b. Elapsed time for the demonstration should be recorded on each motion picture record. Synchronized electronic cameras may be used with the time superimposed in the film processing. A signal light to indicate on the film the beginning, end and duration of each trial should be arranged in the camera field. Test board should be photographed to show the essential details illustrated by each motion picture sequence.
c. The time in tenths of a second from the start of the trial to the instant at which each individual first has both feet on the wing (or if a step is required between the exit and the wing, the time for both feet on the wing, not the step), or the ground at the foot of the slide, according to the conditions of the test, will be determined from the film. This series of times will comprise the cumulated individual escape times for each trial. The individual escape time required for analysis can be obtained by successive subtraction in reverse order.
6. DETERMINATION OF RESULTS.
a. The effectiveness of the non-standard exit, or exits being tested, are compared with the standard exit by comparing the average time of the subgroups to pass through each exit tested. The effects of learning in the subgroups are canceled by use of the Latin Square principle.
b. It is possible that, in spite of efforts to keep the composition of the subgroups equal, that one group may contain one or two persons who find it particularly difficult to go through exits. The Latin Square principle will also cancel such unbalance between subgroups.
c. It may happen that an individual may, through chance, have considerable difficulty with an exit, but his other performance may compare with the average performance of other individuals. A study of the individual escape times will enable such occurrences to be evaluated and assist in the final determination of the acceptability of the proposed exit, or exits.
NOTE: Exemptions must be processed in accordance with part 11. In the evaluation of a request for exemption the recommendations of the controlling Directorate are requested. The foregoing procedure will assist the Directorate in determining what their recommendation should be when the exemption request involves emergency exits.
This appendix was derived from Order 8110.12, 5-21-64.
THIS PAGE INTENTIONALLY LEFT BLANK
781 APPENDIX 5
CRASHWORTHINESS TECHNICAL STANDARD ORDERS (TSO)
1. TSO-C13f, “Life Preservers”
2. TSO-C19b, “Portable Water-Solution Type Fire Extinguishers”
3. TSO-C22g, “Safety Belts”
4. TSO-C39c, “Aircraft Seats and Berths”
5. TSO-C64a, “Oxygen Mask Assembly, Continuous Flow, Passenger”
6. TSO-C69c, “Emergency Evacuation Slides, Ramps, and Slide/Raft Combinations”
7. TSO-C70a, “Liferafts (Reversible and Non-Reversible)”
8. TSO-C72c, “Individual Flotation Devices”
9. TSO-C91a, “Emergency Locator Transmitters (ELT) Equipment”
10. TSO-C99, “Protective Breathing Equipment”
11. TSO-C100B, “Child Restraint Systems (CRS)”
12. TSO-C114, “Torso Restraint Systems”
13. TSO-C116, “Crewmember Protective Breathing Equipment (PBE)”
14. TSO-C126, “406 MHz Emergency Locator Transmitter (ELT)”
15. TSO-C127a, “Rotorcraft and Transport Airplane Seating Systems”
16. TSO-C137, “Aircraft Portable Megaphones”