Appendix 2
SELECTING NUMBER OF BOXES TO USE
(1) Crew rest areas utilizing ambient lonization-type smoke detection systems:
(a) For volumes up to 500 cubic feet use 2 burn boxes with a total of 3 paper towels (see description of operation step 4) 6 quarter sheets folded accordion style in each box. Light either simultaneously or sequenced up to 15 seconds apart.
(b) For volumes greater than 500 cubic feet: scale up fuel (paper towels) by adding 1.5 paper towels for each additional 150 cubic feet. Add Burn Boxes as required, to maintain control of the flame exiting the top of the Burn Box during testing.
(c) Crew rest areas enclosed with curtains, using Ionization type detectors.
(i) If designed with one detector in each bunk, use one burn box with one full sheet of paper towel.
(ii) If crew rest is designed to have one detector protect more than one bunk, use method described in (1) (a) or (b) above, depending on the volume enclosed.
(2) Standard Lavatory with ambient Ionization type detectors:
One Burn Box with 1 sheet of paper towel as fuel placed near the waste receptacle.
1/6/94 AC 25-9A Appendix 2 DOORS (Solid) HEAT RESISTANT MATERIAL (PAD) GLUED ON SHEET METAL
- HINGE 9°6
9.5' BOX CONSTRUCTED OF SHEET METAL RIVETTED ON ANGLE IRON FRAME INNER FRAME (Angle Irons)
BURN BOX SMOKE GENERATOR
OUTER BOX FIGURE 1 3
Appendix 2 AC 25-9A
DOOR WITH SCREEN HINGE
BURN BOX SMOKE GENERATOR - SCREEN FIGURE 2 INNER BOX (WHERE PAPER IS BURNED)
0.75" DIA HOLE (OPENING TO INSERT MATCH)
AIR INLET
4.0"x0.5" 4 SIDES
W/SCREEN
6.25"
6.25" FACING TOWARDS HEAT RESISTANT 1/6/94
SIDE DOOR MATERIAL (PAD)
ON OUTER BOX
1/6/94 BURN BOX SMOKE GENERATOR CLIP (4 PLACES)
TO SECURE INNER BOX FIGURE 3 PLAN VIEW HINGE - DOOR WITH SCREEN
- INNER BOX
OUTER BOX (TOP DOOR NOT SHOWN)
2.25"
HINGE -
SIDE DOOR
MAIA JOL Appendix 2 AC 25-9A
Appendix 1
PAPER TOWEL DIMENSIONS
TOP VIEW
FLAT LENGTH
END VIEW in .
~0.5"