Appendix B Section 25.1733 Flammable fluid shutoff means: EWIS.

Proposed § 25.1733 would require that EWIS associated with each flammable fluid shutoff means and control be “fireproof” (as defined in § 1.1) or located and protected so that any fire in a fire zone will not affect operation of the flammable fluid shutoff means, in accordance with § 25.1189.

Section 25.1189 requires that each engine installation and fire zone have a means to shut off or otherwise prevent hazardous quantities of fuel, oil, deicer, and other flammable fluids from flowing into or through any designated fire zone. No change is proposed for that section.

Section 25.1735 Fire detector systems, general: EWIS.

Proposed § 25.1735 would require that EWIS associated with any installed fire protection system be considered in showing compliance with the applicable requirements for that particular system. This would be a new requirement. It does not currently exist in part 25. The current part 25 regulations contain fire detection system requirements for powerplants (§ 25.1203), lavatories (§ 25.854), and cargo compartments (§§ 25.855,

25.857 and 25.858). Each fire detection system requires electrical wire.

Failure of this wire could lead to inability of the detection system to function properly. The wire and other associated EWIS components must be considered an integral part of the fire detection system and meet the requirements of the applicable regulation. The proposal would apply to all required fire protection systems with the exception of powerplants and APUs. Requirements for EWIS associated with powerplant and APU fire detection systems are contained in proposed § 25.1737.

Section 25.1737 Powerplant and APU fire detector system: EWIS.

Proposed § 25.1737 would require that EWIS that are part of a fire or overheat detector system located in a fire zone be at least fire-resistant, as defined in § 1.1. It would also require that EWIS components of any fire or overheat detector system for any fire zone may not pass through another fire zone unless:

• they are protected against the possibility of false warning caused by fire in the zone through which they pass, or

• each zone involved is simultaneously protected by the same detector or extinguishing system.

B-29

Appendix B In addition, the proposal would require that EWIS that are part of a fire or overheat detector system in a fire zone meet the requirements of § 25.1203.

The current § 25.1203 requires approved, quick acting fire or overheat detectors in each designated fire zone, and in the combustion, turbine, and tailpipe sections of turbine engine installations, to provide prompt indication of fire in those zones. The present rule does contain requirements for wire used in the fire detection systems. But to increase visibility of the related EWIS requirements and to gather them into one central place, a new rule devoted specifically to fire detector system EWIS is proposed.

Existing § 25.1203 would be amended to reference the new § 25.1737, thus effectively closing the loop on requirements.

Section 25.1739 Instructions for Continued Airworthiness: EWIS.

Proposed § 25.1739 would require that applicants prepare EWIS ICA in accordance with the requirements of Appendix H to part 25. The proposed EWIS ICA requirements are discussed in the next section of this document.

Appendix H to Part 25 – Instructions for Continued Airworthiness

As previously noted, improper maintenance, repair, and modifications often hasten the “aging” of EWIS. To properly maintain, repair, and modify airplane EWIS, certain information must be available to the designer, modifier, and installer. This information should be part of the ICA as required by current § 25.1529 and the proposed § 25.1739.

This proposal would amend Appendix H by adding a new section, H25.5, to require TC applicants to develop maintenance information for EWIS as part of the ICA as a requirement for getting a design approval. The proposed rule would also apply to applicants for design change approvals (supplemental TCs and amended TCs).

The proposal would require applicants for TCs to prepare ICA for EWIS that are approved by the FAA Oversight Office, in the form of a document that is easily recognizable as an EWIS ICA. To prepare these instructions, they must use an EZAP such as the one described in AC 25-27 “Development of Transport Category Airplane Electrical Wiring Interconnection Systems Instructions for Continued Airworthiness Using an Enhanced Zonal Analysis Procedure” to perform a review of their representative airplane covering all areas, including the flightdeck (also known as the cockpit), electrical power center, fuel tank wiring and powerfeeder cables, as well as the engine. Applicants for design change B-30

Appendix B approvals would have to perform a similar review for their proposed design changes.

A zonal analysis procedure is an assessment of the structures and systems within each physical zone of the airplane. It is used to develop an inspection program to assess the general condition and security of attachment of all system components and structures items contained in the zone, using general visual inspections (GVI). An enhanced zonal analysis procedure (EZAP) is an enhanced version of the zonal analysis procedure. It focuses on EWIS components. An EZAP-generated inspection program might call for the use of stand-alone GVI and detailed inspections (DET). A stand-alone GVI is one that is performed separately from the regularly scheduled GVI (typically more frequently) and is focused on a particular area or component. In this case, the focus would be wiring. So while the zonal analysis procedure would result in a regularly scheduled GVI for the entire zone, in which each of its systems and structures are inspected at the same time, the EZAP could result in additional GVIs or DETs for the EWIS in that zone, which occur more frequently. These inspection techniques are discussed later in this section.

An EZAP identifies the physical and environmental conditions contained in each zone of an airplane, analyzes their effects on electrical wiring, and assesses the possibilities for smoke and fire. From such an analysis, maintenance tasks can be developed to prevent ignition sources and to minimize the possibilities for combustion by minimizing the accumulation of combustible materials. Such a procedure would involve dividing the airplane into physical areas, or zones, including actual physical boundaries such as wing spars, bulkheads, and cabin floor, and access provisions for the zone, and identifying which of those zones contain EWIS components. For those zones with EWIS components, characteristics and components of all systems installed in the zone would be listed. The EWIS in the zone would be described, including information on the full range of power levels carried in the zone. And the presence or possibilities for ignition sources or accumulation of combustibles would be noted.

Combustibles are any materials that could cause a fire to be sustained in the event of an ignition source. Examples of combustible materials would be dust or lint accumulation, contaminated insulation blankets, and fuel or other combustible liquids or vapors. Wire contaminants are foreign materials that are likely to cause degradation of wiring. Wire contaminants can also be combustibles. Some commonly used airplane liquids, like engine oils, hydraulic fluids, and corrosion prevention compounds, might be readily combustible, but only in vapor or mist form. In that case, an assessment must be made of conditions that could exist within the zone that would convert the liquid to that form. Combustibles appearing as a result of any single failure must be considered. An example would be leaks from B-31

Appendix B connection sites of unshrouded pipes. For the purposes of this new requirement, the term combustible does not refer to material that will burn when subjected to a continuous source of heat as occurs when a fire develops. Combustibles, as used here, will sustain a fire without a continuous ignition source.

An EZAP must address:

• Ventilation conditions in the zone and the density of the installations that would affect the presence and build-up of combustibles and the possibilities for combustion. Avionics and instruments located in the flightdeck and equipment bays, which generate heat and have relatively tightly packed installations, require cooling air flow. The air blown into the area for that cooling tends to deposit dust and lint on the equipment and EWIS components.

• Liquid contamination on wiring. Most synthetic oils and hydraulic fluids, while they might not be combustibles by themselves, could be an aggravating factor for accumulation of dust or lint. This accumulation could then present fuel for fire. Moisture on wiring may increase the probability of arcing from small breaches in the insulation, which could cause a fire. Moisture on wires that contain insulation breaches can also lead to “arc tracking.” As discussed previously, arc tracking is a phenomenon in which an electrical arc forms a conductive carbon path across an insulating surface. The carbon path then provides a short circuit path through which current can flow. Short circuit current flow from arc tracking can lead to loss of multiple airplane systems, structural damage, and fire.

• EWIS in close proximity to both primary and back-up hydraulic, mechanical, or electrical flight controls.

• The type of wiring discrepancies that must be addressed if they are identified by general visual or detailed inspections. A listing of typical wiring discrepancies that should be detectable during EZAP- derived EWIS inspections is given in AC 25-27 “Development of Transport Category Airplane Electrical Wiring Interconnection Systems Instructions for Continued Airworthiness Using an Enhanced Zonal Analysis Procedure"

• Proper cleaning methods for EWIS components.

Once information about such contaminants and combustibles within an airplane zone is collected, each identified possibility for combustion would then be addressed to determine whether a specific task could be performed to reduce that possibility. An example of a specific task to reduce build-up of B-32

Appendix B combustibles on EWIS components is the use of temporary protective covers (such as plastic sheeting) over EWIS components in a zone where corrosion prevention fluids are being used. This would minimize the amount of fluid contamination of the EWIS components. Preventing fluid contamination reduces the probability of other contaminants, like dust and dirt, accumulating on the EWIS components. If no task can be developed to prevent accumulation of combustibles in a zone, such as the dust blown through the air by cooler fans, then tasks must be developed to minimize their buildup, such as scheduled cleaning.

Developing an ICA to define such tasks would include assessing whether particular methods of cleaning would actually damage the EWIS components. Although regular cleaning to prevent potential combustible build-up would be the most obvious task for an EWIS ICA, other procedures might also be called for. A detailed inspection of a hydraulic pipe might be appropriate, for instance, if high-pressure mist from a pinhole caused by corrosion could accumulate on a wire bundle in a low ventilation area, creating a possibility for electrical arcing.

Proximity of EWIS to both primary and back-up hydraulic, mechanical, or electrical flight controls within a zone would affect the criticality of inspections needed, their level of detail, and their frequency. Even in the absence of combustible material, wire arcing could adversely affect continued safe flight and landing if hydraulic pipes, mechanical cables, or wiring for fly-by-wire controls are routed close to other wiring.

The EZAP-generated ICA must be produced in the form of a single document, easily recognizable as EWIS ICA for that specific airplane model.

The single document is relevant to the maintenance and inspection aspects of the ICA, and not the standard wiring practices manual or electrical load analysis, etc.

The ICA must define applicable and effective tasks, and the intervals for performing them, to:

• Minimize accumulation of combustible materials.

• Detect wire contaminants.

• Detect wiring discrepancies that may not otherwise be reliably detected by inspections contained in existing maintenance programs.

As noted earlier, among the types of tasks to be developed from an EZAP are general visual inspections (GVI) and detailed inspections (DET). A GVI is defined as a visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of B-33

Appendix B inspection is made from within touching distance of the inspected object unless otherwise specified. It is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or droplight and may require removal or opening of access panels or doors. It may be necessary to use a mirror to improve visual access to all exposed surfaces in the inspection area. Stands, ladders, or platforms may be required to gain proximity to the area being checked. It is expected that the area to be inspected is clean enough to minimize the possibility that accumulated dirt, grease, or other contaminants might hide unsatisfactory conditions that would otherwise be obvious. It is also expected, as an outcome of the EZAP applied to EWIS, that any cleaning considered necessary would be performed in accordance with procedures that minimize the possibility of the cleaning process itself introducing anomalies. The EZAP must identify guidelines to assist personnel performing a GVI in identifying wiring discrepancies and in assessing what effect such discrepancies, if found, could have on adjacent systems, particularly if these include wiring. As discussed previously, a list of typical wiring discrepancies that should be addressed is contained in AC 25-27 “Development of Transport Category Airplane Electrical Wiring Interconnection Systems Instructions for Continued Airworthiness Using an Enhanced Zonal Analysis Procedure."

A DET is an intensive examination of a specific item, installation, or assembly to detect damage, failure, or irregularity. Available lighting is normally supplemented with a direct source of good lighting at an intensity considered appropriate. Inspection aids, such as mirrors, magnifying lenses, or other means, may be necessary. Surface cleaning and elaborate access procedures may be required. A DET can be more than just a visual inspection. It may include tactile assessment to check a component or assembly for tightness and security. Such an inspection may be needed to ensure the continued integrity of installations such as bonding jumpers, terminal connectors, etc.

A DET would be required when the developer of the EZAP determines that a GVI is inadequate to reliably detect anomalies or degradation of EWIS components. Any detected discrepancies must be corrected according to the operator’s approved maintenance procedures. It is not intended that the EZAP ICA identify how to correct detected discrepancies.

To prevent improper modification and repair of existing EWIS or the improper installation of a new EWIS, modification designers and modification personnel must know the applicable standard wiring practices, EWIS identification requirements, and electrical load data for the airplane undergoing modification. The proposed Appendix H 25.5 would also require that the following information be included in ICA applicable to EWIS:

• Standard wiring practices data.

B-34

Appendix B

• Wire separation design guidelines.

• Information to explain the airplane’s EWIS identification method required by the proposed § 25.1711.

• Electrical load data and instructions for updating that data. Such information will help ensure that those modifying, repairing, or installing new EWIS will not perform any action that will adversely affect previously certified systems and unintentionally introduce potential hazards.

Standard wiring practices are defined as standards developed by the specific airplane manufacturer or industry-wide standards for the repair and maintenance of EWIS. They include procedures and practices for the installation, repair, and removal of EWIS components, including information about wire splices, methods of bundle attachment, connectors and electrical terminal connections, bonding, and grounding. Although a standard wiring practices manual is not a design manual, and those designing a new EWIS modification for a specific model airplane should not use it as such, it does provide the designer with insight into the types of EWIS components used by the TC holder and the procedures recommended by the manufacturer for maintenance or repair that supports continued airworthiness of the components.

EWIS separation guidelines are important for maintaining the safe operation of the airplane. Maintenance and repair personnel need to be aware of the type certificate holders’ separation requirements so they do not compromise separation in previously certified systems. In fuel tank systems, the separation of certain wires may be critical design configuration control items and therefore qualify as an airworthiness limitation. Maintenance personnel need to be aware of these guidelines and limitations because many times wire bundles must be moved or removed to perform necessary maintenance. They must be able to readily identify EWIS associated with systems essential to the safe operation of the airplane.

Similarly, those who design and install new EWIS need to be aware of separation requirements so they can use the same methods to develop the required separation for the EWIS they are adding to the airplane. This would help to ensure both that newly added EWIS is adequately separated from other EWIS, airplane system components, and structure so they do not damage the added EWIS, and that the addition of the new EWIS does not invalidate separation for previously certified EWIS.

Electrical load data and the instructions for updating that data are necessary to help ensure that future modifications or additions of equipment B-35

Appendix B that consume electrical power do not exceed the generating capacity of the onboard electrical generation and distribution system. The existing § 25.1351(a)(1) mandates that the required generating capacity, and the number and kinds of power sources, must be determined by an electrical load analysis. Typically, after an airplane is delivered and enters service, it is modified numerous times throughout its service life. Each addition or deletion of an electrical-power-consuming system changes the electrical load requirements. The only way to ensure that the capacity of the overall generating and distribution system, as well as individual electrical buses, is not exceeded is to have an up-to-date electrical load analysis. The best way to ensure that an up-to-date electrical load analysis is maintained is for the type certificate holder to include such data in the ICA provided with the airplane when it is first delivered to a customer, along with recommended practices for keeping it updated as electrical loads are deleted and added.