FIGURE 11-3. CONDUCTOR CHART, INTERMITTENT FLOW

CIRCUIT

VOLTAGE AMPERES 200 115 | 28 | 14 1600 400 200 100 1200 300 150 1400 800 200 100 1260 720 180 90 200 1120 640 160 80 980 560 140 70 840 480 120 60 700 400 100 50 560 320 40 240 60 30 200 50 24 160 40 20 16 = 18 16 14 48 12 70 40 10 24 22 14 2 1 1/0 2/0 3/0 4/0 14 8 2

VOLTAGE DROP NOTE LENGTH (LI) IS BASED ON CONDUCTOR TEMPERATURES OF 20° C

WIRE SIZE TO DETERMINE LENGTH (LZ) AT HIGHER CONDUCTOR TEMPERATURE USE FORMULA WHERE 12 - ESTIMATED CONDUCTOR TEMPERATURE °C VOLTAGE DROP CHART (254.5) (L1) INTERMITTENT FLOW AT 20° (234.5) + (T2) TIN-PLATED MIL-W-27759

CONDUCTOR Par 11-69 Page 11-36

Page 608OCROpen in PDF

FIGURE 11-4A. SINGLE COPPER WIRE IN FREE AIR 300 WIRE SIZE 26 200 TEMPERATURE DIFFERENCE (WIRE RATING MINUS THE AMBIENT = T IN C) 30 10 30 60 70 80 90100

CURRENT AMPERES

A NOT TO BE USED AS SINGLE WIRE Par 11-69 Page 11-37

Page 609OCROpen in PDF

FIGURE 11-4B. SINGLE COPPER WIRE IN FREE AIR 300 g WIRE SIZE 8 3/0- & 200 TEMPERATURE DIFFERENCE (WIRE RATING MINUS THE AMBIENT = T IN 30 50 60 70 80 90 100 200 300 400 50 600 700 800 9001000

CURRENT AMPERES Par 11-69 Page 11-38

Page 610OCROpen in PDF

FIGURE 11-5. BUNDLE DERATING CURVES

1.0 CURRENT DERATING FACTOR 0.9 BUNDLE LOADING,

PERCENT -20 40

0.6

0.5

0.4

0.3

0.2

0.1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41

NUMBER OF WIRES IN BUNDLE Par 11-69 Page 11-39

Page 611Open in PDF

Par 11-69 Page 11-40 FIGURE 11-6. ALTITUDE DERATING CURVE 11 -70.–11-75. [RESERVED.]

Page 612Open in PDF

Par 11-76 Page 11-41 SECTION 6. AIRCRAFT ELECTRICAL WIRE SELECTION

11-76. GENERAL. Aircraft service imposes severe environmental condition on electrical wire.

To ensure satisfactory service, inspect wire annually for abrasions, defective insulation, condition of terminations, and potential corrosion. Grounding connections for power, distribution equipment, and electromagnetic shielding must be given particular attention to ensure that electrical bonding resistance has not been significantly increased by the loosening of connections or corrosion.

a. Wire Size. Wires must have sufficient mechanical strength to allow for service conditions. Do not exceed allowable voltage drop levels. Ensure that the wires are protected by system circuit protection devices, and that they meet circuit current carrying requirements. If it is desirable to use wire sizes smaller than #20, particular attention should be given to the mechanical strength and installation handling of these wires, e.g., vibration, flexing, and termination. When used in interconnecting airframe application, #24 gauge wire must be made of high-strength alloy.

b. Installation Precautions for Small Wires. As a general practice, wires smaller than size #20 must be provided with additional clamps, grouped with at least three other wires, and have additional support at terminations, such as connector grommets, strain-relief clamps, shrinkable sleeving, or telescoping bushings. They should not be used in applications where they will be subjected to excessive vibration, repeated bending, or frequent disconnection from screw terminations.

c. Identification. All wire used on aircraft must have its type identification imprinted along its length. It is common practice to follow this part number with the five-digit/letter Commercial and Government Entity (CAGE) code identifying the wire manufacturer. Existing installed wire that needs replacement can thereby be identified as to its performance capabilities, and the inadvertent use of a lower performance and unsuitable replacement wire avoided.

(1) In addition to the type identification imprinted by the original wire manufacturer, aircraft wire also contains its unique circuit identification coding that is put on at the time of harness assembly. The traditional “Hot Stamp” method has not been totally satisfactory in recent years when used on modern, ultra-thin-walled installations. Fracture of the insulation wall and penetration to the conductor of these materials by the stamping dies have occurred. Later in service, when these openings have been wetted by various fluids, serious arcing and surface tracking have damaged wire bundles.

(2) Extreme care must be taken during circuit identification by a hot stamp machine on wire with a 10 mil wall or thinner. Alternative identification methods, such as “Laser Printing” and “Ink Jet,” are coming into increasing use by the industry. When such modern equipment is not available, the use of stamped identification sleeving should be considered on thin-walled wire, especially when insulation wall thickness falls below 10 mils.

11-77. AIRCRAFT WIRE MATERIALS. Only wire specifically designed for airborne use must be installed in aircraft.

Page 613Open in PDF

Par 11-77 Page 11-42

a. Authentic Aircraft Wire. Most aircraft wire designs are to specifications that require manufacturers to pass rigorous testing of wires before being added to a Qualified Products List (QPL) and being permitted to produce the wire. Aircraft manufacturers who maintain their own wire specifications invariably exercise close control on their approved sources. Such military or original equipment manufacturer (OEM) wire used on aircraft should only have originated from these defined wire mills. Aircraft wire from other unauthorized firms, and fraudulently marked with the specified identification, must be regarded as “unapproved wire,” and usually will be of inferior quality with little or no process control testing. Efforts must be taken to ensure obtaining authentic, fully tested aircraft wire.

b. Plating. Bare copper develops a surface oxide coating at a rate dependent on temperature. This oxide film is a poor conductor of electricity and inhibits determination of wire.

Therefore, all aircraft wiring has a coating of tin, silver, or nickel, that have far slower oxidation rates.

(1) Tin-coated copper is a very common plating material. Its ability to be successfully soldered without highly active fluxes diminishes rapidly with time after manufacture. It can be used up to the limiting temperature of 150 °C.

(2) Silver-coated wire is used where temperatures do not exceed 200 °C (392 °F).

(3) Nickel-coated wire retains its properties beyond 260 °C, but most aircraft wire using such coated strands have insulation systems that cannot exceed that temperature on long-term exposure. Soldered terminations of nickel-plated conductor require the use of different solder sleeves or flux than those used with tin or silver-plated conductor.

c. Conductor Stranding. Because of flight vibration and flexing, conductor round wire should be stranded to minimize fatigue breakage.

d. Wire Construction Versus Application. The most important consideration in the selection of aircraft wire is properly matching the wire’s construction to the application environment. Wire construction that is suitable for the most severe environmental condition to be encountered should be selected. Wires are typically categorized as being suitable for either “open wiring” or “protected wiring” applications. MIL-W-5088L (replaced by SAE AS50881, Wiring Aerospace Vehicle), Appendix A, Table A-I lists wires considered to have sufficient abrasion and cut-through resistance to be suitable for open-harness construction. MIL-W-5088L (replaced by SAE AS50881, Wiring Aerospace Vehicle), Appendix A, Table A-II lists wires for protected applications. These wires are not recommended for aircraft interconnection wiring unless the subject harness is covered throughout its length by a protective jacket. The wire temperature rating is typically a measure of the insulation’s ability to withstand the combination of ambient temperature and current related conductor temperature rise.

e. Insulation. There are many insulation materials and combinations used on aircraft electrical wire. Characteristics should be chosen based on environment; such as abrasion resistance, arc resistance, corrosion resistance, cut-through strength, dielectric strength, flame resistant, mechanical strength, smoke emission, fluid resistance, and heat distortion. An explanation of many of the abbreviations is identified in the glossary.

Page 614Open in PDF

Par 11-78 Page 11-43

11-78. SUBSTITUTIONS. In the repair and modification of existing aircraft, when a replacement wire is required, the maintenance manual for that aircraft must first be reviewed to determine if the original aircraft manufacturer (OAM) has approved any substitution. If not, then the OAM must be contacted for an acceptable replacement.

a. MIL-W-5088L (replaced by SAE AS50881, Wiring Aerospace Vehicle) Appendix A lists wire types that have been approved for military aerospace applications in open and protected wiring applications. These wires could potentially be used for substitution when approved by the OAM.

b. Areas designated as severe wind and moisture problem (SWAMP) areas differ from aircraft to aircraft but generally are considered to be areas such as wheel wells, near wing flaps, wing folds, pylons, and other exterior areas that may have a harsh environment. Wires for these applications often have design features incorporated into their construction that may make the wire unique; therefore an acceptable substitution may be difficult, if not impossible, to find. It is very important to use the wire type recommended in the aircraft manufacturer’s maintenance handbook.

c. The use of current military specification, multiconductor cables in place of OEM installed constructions may create problems such as color sequence. Some civilian aircraft are wired with the older color sequence employing “Red-Blue-Yellow” as the first three colors.

Current military specification, multiconductor cables, in accordance with MIL-DTL-27500 (NEMA WC27500), use “White-Blue-Orange” for the initial three colors. Use of an alternative color code during modification without adequate notation on wiring diagrams could severely complicate subsequent servicing of the aircraft.

TABLE 11-1 2. COMPARABLE PROPERTIES OF WIRE INSULATION SYSTEMS 11 -79.–11-84. [RESERVED.]

Page 615Open in PDF

Par 11-85 Page 11-44 SECTION 7. TABLE OF ACCEPTABLE WIRES

11-85. AIRCRAFT WIRE TABLE. Tables 11-13 and 11-14 list wires used for the transmission of signal and power currents in aircraft. It does not include special purpose wires such as thermocouple, engine vibration monitor wire, fiber optics, data bus, and other such wire designs. Fire resistant wire is included because it is experiencing a wider application in aircraft circuits beyond that of the fire detection systems.

a. All wires in Tables 11-13 and 11-14 have been determined to meet the flammability requirements of 14 CFR part 25, § 25.1713(c) and the applicable portion of part 1 of appendix F part 25.

b. The absence of any wire from Tables 11-13 and 11-14 are not to be construed as being unacceptable for use in aircraft. However, the listed wires have all been reviewed for such use and have been found suitable, or have a successful history of such usage.

c. Explanations of the various insulation materials mentioned in Table 11-13, by abbreviations, can be found in Appendix 1.

TABLE 11-13. OPEN WIRING Document Voltage Rating (maximum) Rated Wire Temperature (°C) Insulation Type Conductor Type M22759/1 600 200 Fluoropolymer insulated TFE and TFE coated glass Silver coated copper M22759/2 600 260 Fluoropolymer insulated TFE and TFE coated glass Nickel coated copper M22759/3 600 260 Fluoropolymer insulated TFE-glass TFE Nickel coated copper M22759/4 600 200 Fluoropolymer insulated TFE-glass FEP Silver coated copper M22759/5 600 200 Fluoropolymer insulated extruded TFE Silver coated copper M22759/6 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper M22759/7 600 200 Fluoropolymer insulated extruded TFE Silver coated copper M22759/8 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper M22759/9 1000 200 Fluoropolymer insulated extruded TFE Silver coated copper

Page 616Open in PDF

Par 11-85 Page 11-45 Document Voltage Rating (maximum) Rated Wire Temperature (°C) Insulation Type Conductor Type M22759/10 1000 260 Fluoropolymer insulated extruded TFE Nickel coated copper M22759/13 600 135 Fluoropolymer insulated FEP PVF2 Tin coated copper M22759/16 600 150 Fluoropolymer insulated extruded ETFE Tin coated copper M22759/17 600 150 Fluoropolymer insulated extruded ETFE Silver coated high-strength copper alloy M22759/20 1000 200 Fluoropolymer insulated extruded TFE Silver coated high-strength copper alloy M22759/21 1000 260 Fluoropolymer insulated extruded TFE Nickel coated high strength copper alloy M22759/34 600 150 Fluoropolymer insulated cross-linked modified ETFE Tin coated copper M22759/35 600 200 Fluoropolymer insulated cross-linked modified ETFE Silver coated high strength copper alloy M22759/41 600 200 Fluoropolymer insulated cross-linked modified ETFE Nickel coated copper M22759/42 600 200 Fluoropolymer insulated cross-linked modified ETFE Nickel coated high strength copper alloy M22759/43 600 200 Fluoropolymer insulated cross-linked modified ETFE Silver coated copper MIL-W-25038/3/2 600 260 See specification sheet * See specification sheet MIL-W-81044/6 600 150 Cross-linked polyalkene Tin coated copper MIL-W-81044/7 600 150 Cross-linked polyalkene Silver coated high-strength copper alloy MIL-W-81044/9 600 150 Cross-linked polyalkene Tin coated copper MIL-W-81044/10 600 150 Cross-linked polyalkene Silver coated high-strength copper alloy * Inorganic Fibers Glass TFE

Page 617Open in PDF

Par 11-85 Page 11-46 TABLE 11-14. PROTECTED WIRING Document Voltage Rating (maximum) Rated Wire Temperature (°C) Insulation Type Conductor Type M22759/11 600 200 Fluoropolymer insulated extruded TFE Silver coated copper M22759/12 600 260 Fluoropolymer insulated extruded TFE Nickel coated copper M22759/14 600 135 Fluoropolymer insulated FEP-PVF2 Tin coated copper M22759/15 600 135 Fluoropolymer insulated FEP-PVF2 Silver plated high-strength copper alloy M22759/18 600 150 Fluoropolymer insulated extruded ETFE Tin coated copper M22759/19 600 150 Fluoropolymer insulated extruded ETFE Silver coated high-strength copper alloy M22759/22 600 200 Fluoropolymer insulated extruded TFE Silver coated high-strength copper alloy M22759/23 600 260 Fluoropolymer insulated extruded TFE Nickel coated high-strength copper alloy M22759/32 600 150 Fluoropolymer insulated cross-linked modified ETFE Tin coated copper M22759/33 600 200 Fluoropolymer insulated cross-linked modified ETFE Silver coated high-strength copper alloy M22759/44 600 200 Fluoropolymer insulated cross-linked modified ETFE Silver coated copper M22759/45 600 200 Fluoropolymer insulated cross-linked modified ETFE Nickel coated copper M22759/46 600 200 Fluoropolymer insulated cross-linked modified ETFE Nickel coated high-strength copper alloy MIL-W-81044/12 600 150 Cross-linked polyalkene-PVF2 Tin coated copper MIL-W-81044/13 600 150 Cross-linked polyalkene-PVF2 Silver coated high-strength copper alloy

Page 618Open in PDF

Par 11-85 Page 11-47 Document Voltage Rating (maximum) Rated Wire Temperature (°C) Insulation Type Conductor Type MIL-W-81381/17 600 200 Fluorocarbon polyimide Silver coated copper MIL-W-81381/18 600 200 Fluorocarbon polyimide Nickel coated copper MIL-W-81381/19 600 200 Fluorocarbon polyimide Silver coated high-strength copper alloy MIL-W-81381/20 600 200 Fluorocarbon polyimide Nickel coated high-strength copper alloy MIL-W-81381/21 600 150 Fluorocarbon polyimide Tin coated copper

11-86. OPEN AIRFRAME INTERCONNECTING WIRE. Interconnecting wire is used in point-to-point open harnesses, normally in the interior or pressurized fuselage, with each wire providing enough insulation to resist damage from handling and service exposure. (See Table 11-13.) Electrical wiring is often installed in aircraft without special enclosing means. This practice is known as open wiring and offers the advantages of ease of maintenance and reduced weight.

11-87. PROTECTED WIRE. Airborne wire that is used within equipment boxes, or has additional protection, such as an exterior jacket, conduit, tray, or other covering is known as protected wire. (See Table 11-14.)

11-88. SEVERE WIND AND MOISTURE PROBLEMS (SWAMP).

a. Areas such as wheel wells, wing fold and pylons, flap areas, and those areas exposed to extended weather shall dictate selection and will require special consideration. Insulation or jacketing will vary according to the environment. Suitable wire types selected from MIL-W-22759 (M22759) shall be used in these applications. (See Table 11-13.)

b. Suitable wire types selected from MIL-W-22759 are preferred for areas that require repeated bending and flexing of the wire. Consideration should be made to areas that require frequent component removal or repair. (See Table 11-13.)

11-89. SHIELDED WIRE. With the increase in number of highly sensitive electronic devices found on modern aircraft, it has become very important to ensure proper shielding for many electric circuits. Shielding is the process of applying a metallic covering to wiring and equipment to eliminate interference caused by stray electromagnetic energy. Shielded wire or cable is typically connected to the aircraft’s ground at both ends of the wire, or at connectors in the cable.

Electromagnetic Interference (EMI) is caused when electromagnetic fields (radio waves) induce high-frequency (HF) voltages in a wire or component. The induced voltage can cause system inaccuracies or even failure, therefore putting the aircraft and passengers at risk. Shielding helps to eliminate EMI by protecting the primary conductor with an outer conductor. Refer to