Appendix A

PAINTING AND LIGHTING OF WATER TOWERS

AND SIMILAR STRUCTURES Day Protection = Aviation Orange / White Paint Night Protection = 2,000 cd Red Light and 32 cd Red Steady-Burning Side Lights The number of light units recommended depends on the diameter of the structure Above 150 ft (45 m) but not more than 350 ft (108 m) = L-864 (Flashing Red Light)

• =L-810 (Steady-Burning Red Light) Figure A-16. Painting and Lighting of Water Towers and Similar Structures A-17

Page 77OCROpen in PDF

Appendix A

PAINTING OF SINGLE PEDESTAL WATER TOWER

BY TEARDROP PATTERN Day Protection = Aviation Orange / White Paint Night Protection = By Flood Light JAN ‚USA = 360° Coverage of the Water Tower (Flood Light) Figure A-17. Painting a Single Pedestal Water Tower Using the Teardrop Pattern A-18

Page 78OCROpen in PDF

Appendix A

LIGHTING ADJACENT STRUCTURES

LIGHT LEVEL ADJUSTMENT Day Protection = 270,000 cd White Light (Painting is typically not required) Twilight Protection = 20,000 cd White Light Night Protection = 2,000 cd White Light Inboard lights recommended on all levels above height of shorter structure 500 ft or less (153 m) 795 ft (242 m) Lower inboard lights may be omitted 534 ft = = (166 m) 545 ft (163 m) 800 ft (244 m) 275 ft !

270 ft (84 m) ** 267 ft 82 m) 550 ft

• (81 m) (168 m) Minor adjustments in vertical placement may be made to place lights on same horizontal plane (Lights on both structures to be synchronized) = L-856 (Flashing White Light) = L-865 (Flashing White Light) Figure A-18. Lighting Adjacent Structures-Light Level Adjustment A-19

Page 79OCROpen in PDF

Appendix A

LIGHTING ADJACENT STRUCTURES Day Protection = 270,000 cd White Light (Painting of tower is typically not required) Twilight Protection = 20,000 cd White Light Night Protection = 2,000 cd White Light 500 ft (153 m) or less

• 0 Inner levels ce o may be omitted 750 ft (229 m) 250 ft (76 m) Lowest level should be above adjacent structure Structures of equal height. Number of levels depends upon height of structure (Lights on both structures to be synchronized) Top level display all units" 500 ft or less 500 ft or less_ (153 m) (153 m) Lower inner levels may be omitted One structure higher than the adjacent structure and light levels are on same horizontal plane (Lights on both structures to be synchronized) = L-856 (Flashing White Light) =L-865 (Flashing White Light) One structure higher than the adjacent structure and light levels are on same horizontal plane (Lights on both structures to be synchronized) Figure A-19. Lighting Adjacent Structures A-20

Page 80OCROpen in PDF

Appendix A

LIGHTING OF CHIMNEYS, FLARE STACKS,

OR SIMILAR SOLID STRUCTURES Day Protection = 270,000 cd White Light (Painting of tower is typically not required) Twilight Protection = 20,000 cd White Light Night Protection = 2,000 cd White Light b - Exceeding 20 ft (6 m) but not more than 100 ft (31 m) a - 20 ft (6 m) or less 800 ft (244 m) 300 ft (91 m) = L-856 (Flashing White Light) = L-865 (Flashing White Light) Figure A-20. Lighting of Chimneys, Flare Stacks, or Similar Solid Structures A-21

Page 81OCROpen in PDF

Appendix A

LIGHTING HYPERBOLIC COOLING TOWERS Day Protection = 270,000 cd White Light (Painting of tower is typically not required) Twilight Protection = 20,000 cd White Light Night Protection = 2,000 cd White Light a - The number of light units recommended depends on the a - Exceeding 100 ft (31 m) diameter of the structure but not more than 200 ft (61 m)

- b b - Exceeding 200 ft (61 m) IWA = L-856 (Flashing White Light) Figure A-21. Hyperbolic Cooling Tower A-22

Page 82OCROpen in PDF

Appendix A

BRIDGE LIGHTING Day / Twilight Protection = 20,000 cd White Light Night Protection = 2,000 cd Red or White Light or Flood Lighting * Shown above as L-864 / L-865 (Flashing Dual Light) Marine navigational lighting not shown = L-864 (Flashing Red Light)

- = L-865 (Flashing White Light) = L-864 / L-865 (Flashing Dual Light) Figure A-22. Bridge Lighting A-23

Page 83OCROpen in PDF

Appendix A

WIND TURBINE LIGHTING Day / Twilight Protection = Wind Turbine Off-White Paint Night Protection = 2,000 cd Red Light / 32 cd Red Side Lights Two FAA Type L-864 Mounted on opposite rear sides of the nacelle Two FAA Type L-864 Mounted on opposite rear sides of the nacelle One FAA Type L-864 Three or more FAA Type L-810 Tubine height is determined spaced around mast from the top of rotor while flash in sync with L-864 configured to at top dead center Turbines 499 ft (152 m) Turbines above Turbines above or lower 499 ft (152 m) 699 ft (213 m) but less than 699 ft (213 m) = L-864 (Flashing Red Light) Configured to flash at a rate of 30 fpm (+ 3 fpm) = L-810 (Single Light) Configured to flash in sync with L-864 Figure A-23. Wind Turbine Lighting A-24

Page 84OCROpen in PDF

Appendix A

LIGHTING AND MARKING OF WIND TURBINES

IN SNOW PRONE AREAS (OPTIONAL) Day / Twilight Protection = Aviation Orange and Wind Turbine Off-White Paint Night Protection = 2,000 cd Red Lights / 32 cd Red Side Lights Two FAA Type L-864 Mounted on opposite rear sides of the nacelle Two FAA Type L-864 Mounted on opposite rear sides of the nacelle One FAA Type L-864 Three or more FAA Type L-810 Tubine height is determined spaced around mast from the top of rotor while configured to at top dead center flash in sync with L-864 Turbines 499 ft (152 m) Turbines above Turbines above or lower 499 ft (152 m) 699 ft (213 m) but less than 699 ft (213 m) = L-864 (Flashing Red Light) Configured to flash at a rate of 30 fpm (+ 3 fpm) = L-810 (Single Light) Configured to flash in sync with L-864 Figure A-24. Wind Turbine Lighting and Marking in Snow Prone Areas (Optional) A-25

Page 85OCROpen in PDF

Appendix A

LIGHTING AND MARKING OF WIND TURBINES

PAINT SCHEMES Day / Twilight Protection = Aviation Orange and Wind Turbine Off-White Paint Night Protection = 2,000 cd Red Lights / Turbines Under 499 ft (152 m)

APPROVED PAINT SCHEMES Painting based on Standard paint scheme snow prone areas

NOT APPROVED PAINT SCHEMES Striped Blades Painted Blades Gradient painted mast = L-864 (Flashing Red Light) Figure A-25. Lighting and Marking of Wind Turbines - Paint Schemes A-26

Page 86OCROpen in PDF

Appendix A

WIND TURBINE LIGHTING CONFIGURATIONS Day / Twilight Protection = Wind Turbine Off-White Paint Night Protection = 2,000 cd Red Light / 32 cd Red Side Lights No more than Place a light One-half Statute Mile (2,640 ft (805 m) lit turbines towards the starting point If last segment is short, push the for balanced lighting (on each end) Turbine with no light Place a light (on each end) Starting Point Linear Turbine Configuration Cluster Turbine Configuration Grid Turbine Configuration = L-864 (Flashing Red Light) Figure A-26. Wind Turbine Lighting Configurations A-27

Page 87OCROpen in PDF

Appendix A

AIRCRAFT DETECTION LIGHTING SYSTEM (ADLS) SAMPLE WIND FARM COVERAGE MAP * Multiple ADLS units required for the above wind farm Vertical Coverage Horizontal Coverage 1,000 ft (304 m) 3 Nautical Miles