N10156

Service difficulty reports · 152

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N10156' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR JJBA20260922007Battery · inoperative#4 EMERGENCY BATTERY LIGHTS ARE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK #4. OPS CHECK SAT.Sep 19, 2026 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20260914005Unknown · odorDIRTY SOCK SMELL FROM PACK 1. NOTICED SMELL IN FLIGHT DECK, OCCURRED WHEN RUNNING PACK OFF THE APU. GROUND RUN APU AND ENGINES. NO OIL LEAKS NOTED. OPS CHECK PACK SYSTEM. COULD NOT DUPLICATE SMELL. OPS CHECK SAT.Sep 14, 2026 · N10156 · Emb EMB145XR · Air Distribution SystemSDR JJBA20260914006Sleeve · inoperativeCHEMICAL SMELL COMING FROM PACK 1 WHEN SELECTED ON. FOUND PACK 1 Y DUCT BURNT. REMOVED AND REPLACED PACK 1 Y DUCT AND SLEEVES. PERFORMED OPS CHECK OF AIR DISTRIBUTION SYSTEM. NO CHEMICAL SMELL DETECTED. LEAK/OPS CHECK SAT.Sep 13, 2026 · N10156 · Emb EMB145XR · Air Distribution SystemSDR JJBA20260720011Battery Pack · inoperativeMULTIPLE EMERGENCY EXIT SIGNS INOPERATIVE, LT OVERWING EXIT BOTH, LOWER ON RT OVERWING EXIT, ROW 18 AFT UPPER CEILING. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY NR 3. OPS CHKD SAT.Jul 15, 2026 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20251204004Battery Pack · inoperativeMULTIPLE EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BPS NR 3. OPS CHECK SAT.Dec 2, 2025 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20250902065Battery Pack · inoperativeNR 1 EMERGENCY LIGHT BATTERY NOT HOLDING CHARGE. REMOVED AND REPLACED NR 1 EMERGENCY BATTERY. OPS CHECK GOOD.Aug 31, 2025 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20250623018Handle · lack of lubeMAIN CABIN DOOR HARD TO CLOSE AND LOCK. FOUND MCD HARD TO LOCK FROM INSIDE. LUBRICATED INTERNAL ACTUATING HANDLE WITH LPS. ACTUATED MCD SEVERAL TIMES. OC SAT.Jun 20, 2025 · N10156 · Emb EMB145XR · Passenger/Crew DoorsSDR JJBA20250616013Screen · faultedBURNING SMELL, LIKE FIREWORKS, DURING CRUISE AND INTO DESCENT. PERFORMED FIM. FOUND PACK 2 EXHAUST GRATE AND DUCT TO BE AT FAULT. REMOVED AND REPLACED PACK 2 EXHAUST GRATE AND DUCT. OPS CHECK GOOD AT THIS TIME. NO FURTHER DEFECTS NOTED. NO BURNING SMELL NOTED.Jun 14, 2025 · N10156 · Emb EMB145XR · Air Distribution SystemSDR JJBA20250408037Muffler · splitSMELLED SMOKE IN COCKPIT ON TAKE OFF. NO EICAS MESSAGES. ON TAKEOFF NOTICED THE SMELL OF SMOKE. APU BLEED WAS ON. BOTH PACKS WERE ON. #1 AND #2 ENGINES BLEEDS OFF. INITIAL SMELL WAS LIKE A SANDWICH OR FOOD THEM SMELL TURNED TO ELECTRICAL. NO VISIBLE SMOKE. FLAApr 5, 2025 · N10156 · Emb EMB145XR · Air Distribution FanSDR JJBA20250213017Door Seal · unsecureMCD UNABLE TO LOCK/SECURE WHEN CLOSING. FOUND MCD SEAL POPPED FROM DOOR LOWER FWD, RESECURED DOOR SEAL. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.Feb 10, 2025 · N10156 · Emb EMB145XR · Passenger/Crew DoorsSDR JJBA20240207008Signal Cond Unit · inoperativeFUEL TRANSFER INOPERATIVE. REMOVED AND REPLACED FUEL SIGNAL CONDITIONING UNIT. OPS CHECK GOOD, PUSHED IN CIRCUIT BREAKERS.Feb 5, 2024 · N10156 · Emb EMB145XR · Aircraft Fuel Distribution SystemSDR JJBA20240129045Lamp · inoperativeMCD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOOD.Jan 26, 2024 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20231204003Lamp · inoperativeMCD EMERGENCY LIGHT OUT. REMOVED AND REPLACED MCD EMERGENCY LIGHT BULB. OPS CHECK GOOD.Dec 2, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230821006Lamp · inoperativeMCD EMERGENCY LIGHT OUT. REMOVED AND REPLACED BULB. OPS CHECK SAT.Aug 18, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230508003Lamp · inoperativeMCD EMERGENCY LIGHT OUT. REMOVED AND REPLACED MCD EMERGENCY LAMP. OPS CHECK SAT.May 6, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230501016Lamp · inoperativeMCD EMERGENCY & SEAT 18CD LIGHT INOPERATIVE. REMOVED AND REPLACED BAD BULBS AT MCD EMERGENCY LIGHT AND SEAT 18CD OH EMERGENCY LIGHT. OPS CHECK GOOD.Apr 30, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230424011Battery · inoperativeEMERGENCY LIGHT EXIT SIGN ABOVE SERVOOR IS INOPERATIVE. REMOVED AND REPLACED #2 EMERGENCY LIGHT BATTERY. OPS CHECK GOOD.Apr 23, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230410005Battery Pack · inoperativeTHREE EMERGENCY LIGHTS OUT AT EMERGENCY ROW. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AND CHASSIS ASSEMBLY. BATTERY PACK TESTS GOOD, EMERGECY LIGHTS OPS CHECK GOOD.Apr 8, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230410003Lamp · inoperativeMCD EXTERNAL EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXTERNAL EMERGENCY LIGHT LAMP. OPS CHECK SATApr 8, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230404042Battery · inoperativeTHREE EMERGENCY LIGHT OUT AT EMERGENCY ROW. REMOVED AND REPLACED EMERGENCY EXIT IDENTIFIER & MARKING SIGNS ROW 18A. DURING OPS CHECK, REPLACED LIGHTS FADED DURING TEST. REMOVED AND REPLACED EMERGENCY BATTERY PACK NO 3. LIGHTS OPS CHECK GOOD.Mar 31, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230315018Pressure Sensor · inoperativeRUDDER OVERBOOST ON EICAS AFTER TAKEOFF. REMOVED AND REPLACED RUDDER PRESSURE SW. LEAK AND OPS CHECK SAT. PERFORMED PITOT TEST. NO FURTHER DEFECTS NOTED.Mar 14, 2023 · N10156 · Emb EMB145XR · Flight Control SystemSDR JJBA20230123013Windshield · crackedFO W/S SPIDER WEB CRACKED DURING FLIGHT. REMOVED AND REPLACED FO'S WINDSHIELD. OPS CHECK SAT AT THIS TIME.Jan 18, 2023 · N10156 · Emb EMB145XR · Flight Compartment WindowsSDR JJBA20230116010Battery Pack · inoperativeMULTIPLE INTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BPS #3. OPS CHECK OF ALL CORRESPONDING LIGHTS GOODJan 13, 2023 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20230106001Sleeve · misinstalledSTAB ANTI-ICE EICAS MESSAGE POSTED IN FLIGHT. DURING APPROACH AND ICE CONDITION ANTI-ICE INOPERATIVE MESSAGE APPEARED. CMC MSG "STAB A/I LEAK" AND "STAB A/I VLV FAIL" PRESENT. STARTED PERFORMING INSTALLATION OF LEAK TEST KIT FOR HORIZONTAL STAB VERTICAL DUCTSJan 2, 2023 · N10156 · Emb EMB145XR · Airfoil Anti/De-ice SystemSDR JJBA20221212006Battery Pack · inoperativeLH AND RH EMERGENCY EXIT DOOR OVERHEAD LIGHTS AND EXIT MARKERS DO NOT ILLUMINATE. REMOVED AND REPLACED BPS #3. ALL LIGHTS ILLUMINATE. OPS CHECK GOOD.Dec 12, 2022 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20221212005Lamp · inoperativeMCD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT. OPS CHECK SATDec 8, 2022 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20221114010Battery Pack · inoperativeRH AND LH CABIN ESCAPE HATCH EXIT MARKING SIGNS INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY. OPS CHECK SAT.Nov 12, 2022 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20220914013None · missingSERVICE DOOR RED "EXIT" IS PARTIALLY MISSING. REMOVED AND REPLACED SERVICE DOOR EXIT PLACARD. NO DEFECTS NOTED.Sep 13, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220912011Battery Pack · inoperativeLEFT WINDOW EMERGENCY EXIT LIGHTS OUT AND RT REAR EMERGENCY LIGHTS OUT. REMOVED AND REPLACED #3 EMERGENCY LIGHT BATTERY. OPS CHECK GOODSep 10, 2022 · N10156 · Emb EMB145XR · Emergency LightingSDR JJBA20220808005Web · crackedFAIRLEAD ATTACHMENT HOLE FOUND WITH OBLONG CONDITION AT F.S. 56 19115.6 ON LH SIDE FRAME WEB. ACCOMPLISHED PERMANENT REPAIR ON FRM 56.Jul 25, 2022 · N10156 · Emb ERJ170200LR · Aileron Control SystemSDR JJBA20220617007None · noneLH FLOOR GUSSET FR 24-38 LBL 18 HAS CORROSION SEVERAL AREAS BETWEEN AND AROUND TRACKS. REPLACED FLOOR GUSSET FR 24-29, FR 36-39Jun 17, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220616005None · noneCO-PILOT SEAT TRACKS HAS SIGNS OF CORROSION ON GUSSET. REMOVED DAMAGED DOUBLER SHEET FLOOR AND INSTALLED NEW DOUBLER SHEET FLOOR AT CO-PILOT FLOOR O/B GUSSETJun 16, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220615006None · noneSIGNS OF CORROSION AT FR58 STR 20R STRINGER HAS SIGNS OF CORROSION. REMOVED AND REPLACED STRINGER AT FR58-60, STR 20R. NO DEFECTS NOTED AT THIS TIME.Jun 15, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220601001None · noneCENTER FLOOR TRACKS HAVE CORROSION FR 25-43 BL0. REMOVED CORROSION AT CABIN SEAT TRACK BL0 FROM FR 25-43. EVALUATED SEAT TRACK FROM FR 26, 28, 33, 34, 36 AND 38-40 FOUND TO BE WITHIN LIMITS. EVALUATED SEAT TRACK FROM FR 25, 27, 29, 30-32, 35 AND 37 FOUND TO BEJun 1, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220531060None · noneLH CENTER FUSELAGE I HAS DENT FWD OF FRM 20 BELOW STGR 14. EVALUATED DENT DIM ARE L=1.20 W=.780 D=.030 NF-700 FOUND TO BE OUT OF LIMITS. RECONTOURED DENT LH FUSELAGE FR20 BELOW STR 14. REEVALUATED DENT L=.550 W=.40 D=.015 NF-800 AND DENT HAS SHARP EDGE FOUND TMay 31, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220531054None · noneSIGNS OF CORROSION ON FLOOR GUSSET AT FR59 TO FR60 APPROX LBL15. REMOVED AND REPLACED FLOOR GUSSET AT FR59 TO FR60 APPROX LBL 15May 31, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526047None · noneLH WINDSHIELD HAS SIGNS OF CORROSION AT LOWER OUTBD FLANGE ON BACKSIDE. EVAL AREA AT LH WINDSHIELDS LOWER OUTBD FLANGE ON BACK SIDE, FWD ORIG THICKNESS .160" MAT LOSS .011" REMAINING MAT .149" ON AFT SIDE ORIG THICKNESS .160" MAT LOSS .018" REMAINING MAT .142 May 26, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220526046None · noneANGLE SHAPE FOUND CRACKED ON INBD SIDE OF MAIN FLOOR BEAM Y - 479.0 BTW STA 4154.5 & 5633.0. REMOVED AND REPLACED ANGLE AS REQUIREDMay 26, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220525044None · noneAGING AIRCRAFT FINDING: FLOOR PANEL 231JF AFT SUPPORT AT MAIN DOOR HAS SIGNS OF CORROSION. REMOVED AND REPLACED 1EA SHAPE U SUPPORT AFT AT MAIN DOORMay 25, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220519034None · noneBRACKET ON RH SIDE OF VENTRAL TANK IS BROKEN. REMOVED AND REPLACED BROKEN BRACKET ON RH SIDE OF VENTRAL TANKMay 19, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220519033None · noneUPON REMOVAL OF SHROUD FOUND CORROSION AT FR61 RH PARTITION PANEL. REMOVED AND REPLACED RH DOUBLER FWD PORTITION AT FR61. NO DEFECTS NOTED AT THIS TIMEMay 19, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220519032None · noneSTIFFENER ON FR65 AT STR 14R-STR15R HAS SIGNS OF CORROSION. REPLACED STIFFENER ON FR65May 19, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220518031None · noneLH OB LATERAL FLOOR SUPPORT CORROSION FR 24-34 LBL30. REMOVED AND REPLACED LH OB LATERAL FLOOR SUPPORT (SILL) BTW FR24 AND FR30 LBL 30May 18, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220513030None · noneCORROSION FWD CENTER DOOR GUSSET FR15 LBL28. REMOVED AND REPLACED FWD ENTRY DOOR GUSSET FR15 LBL28May 13, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220512029None · noneSERVICE DOOR SILL LOWER HAS MISSING RIVETS, SIGNS OF CORROSION, FASTENERS ARE MISS BUCKED. REMOVED AND REPLACED SERVICE DOOR SILL LWR.May 12, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220512028None · noneCENTER FLOOR GUSSET CORROSION FR19-24 BL0. CLEANED AND EVALUATED CENTER FLOOR GUSSET CORROSION AT FR19-FR24 BL0. UPON EVALUATION FOUND TO BE 100% OUT OF LIMITS. REMOVED AND REPLACED CENTER FLOOR GUSSET.May 12, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220506021None · noneCENTER FLOOR GUSSET HAS MULTIPLE AREAS OF CORROSION FR 23-25 BL0. REMOVED AND REPLACED CENTER FLOOR GUSSET AT FR 24-29 BL0. NO DEFECTS NOTED AT THIS TIMEMay 6, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220504020None · noneLH SEAT TRACK ON FLOOR CORRODED FR 53-57 LBL 18. REMOVED CORROSION FROM LBL 18 SEAT TRACKS FROM FR53-55. SEAT TRACK FROM FR56-57 FOUND TO BE OUT OF LIMITS. PERFORMED ET ON SEAT TRACKS FROM FR53-55 NO CRACKS FOUND. THICKNESS CHECK, ALL MEASUREMENTS ABOVE MIN REMay 4, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220504013None · noneRH FLOOR SILL HAS SIGNS OF CORROSION FROM FR68-71. EVALUATED ON RH FLOOR SILL AT FR68-71, FOUND TO BE 100% OUT OF LIMITS. REMOVED RH FLOOR SILL. LOCATED AND DRILLED NEW RH FLOOR SILL. INSTALLED NEW RH FLOOR SILL. ALODINED AND PRIMED HOLES.May 4, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)SDR JJBA20220503007None · noneDURING ACCESS REMOVAL RH AFT CARGO FLOOR SILL FOUND BLEED AIR DUCT BRACKET CRACKED FR73 RH SIDE OF SUPPORT. REMOVED, FABRICATED AND INSTALLED REPLACEMENT BLEED AIR DUCT BRACKET AT RH AFT CARGO FLOOR SILL FR73, RH SIDE.May 3, 2022 · N10156 · Emb EMB145XR · Fuselage Structure (General)
Back to N10156