N106HQ
Service difficulty reports · 88
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N106HQ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N106HQ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A2026090500256Power Supply · no testFWD LEFT EMERGENCY LIGHTS WENT OUT DURING EMERGENCY LIGHT FUNCTION TEST. R & R ELPU 1.SDR R61A2025051500245Stringer · corrodedCORROSION ON STGR 28R BETWEEN FR 86-87. REMOVED AND REPAIRED STGR AT 28R BETWEEN FR 83-FR90 PER ETD 2025-170-919988SDR R61A2025051500244Crossbeam · gougedFRAME 80 RH CROSSBEAM HAS TOOLING MARKS. REMOVED AND INSTALL CROSSBEAM REPAIR DOUBLER PER ETD2025-170-906955SDR R61A2023012500074Engine · vibrationATC DECLARED AN EMERGENCY FOR THE FLIGHT DUE TO ENGINE VIBES. LANDED WITHOUT INCIDENT. PERFORMED GVI AND ISSUED DMI FOR VIBE SCOPE.SDR R61A2022120100764Skin · crackedSUSPECTED SEVERAL CRACKS RH LOWER WING OUTBD OF RIB 4 DOUBLER. PERFORMED TEMPORARY DOUBLER REPAIR ON RH LOWER WING SKIN O/B OF RIB 4. REF EMB ETD2022-170-033654SDR R61A2021081800655Door · dirtyL2 DOOR WILL NOT DISARM. REMOVED DEBRIS.SDR R61A2021051400421Gate · disengagedL2 DOOR VENT FLAP NOT DISENGAGING. LUBRICATED L2 DOOR VENT FLAP ROD.SDR R61A2020110100724Crossbeam · corrodedDURING HEAVY MAINTENANCE CHECK FOUND CORROSION ON CROSSBEAM AT FR 84 BETWEEN LT AND RT SEAT TRACK. PERFORMED PERMANENT REPAIR CUTOUT AND L ANGLE FABRICATION ON CROSSBEAM AT FR 84 BETWEEN LT AND RT SEAT TRACK, REF ETD2020-170-029876 AND EMB SRM 53-00-10, 51-40SDR R61A2020072700575Door · out of adjustL2 DOOR DIFFICULT TO ARM AND DISARM. PERFORMED ADJ/TEST IAW AMM 52-12-00. OPS CHECKS GOOD.SDR R61A201905220538Flap · out of adjustDOOR L2 VENT FLAP DOOR IS DIFFICULT TO OPERATE. ADJUSTED L2 DOOR VENT FLAP ASSY IAW CMM 52-12-22.SDR R61A201905220537Door · lack of lubeL2 SERVICE DOOR WILL NOT DISARM. APPLIED LUBRICATION PER CPM 51-27-02. OPS CHECKED L2 DOOR PER AMM 52-12-00. OPS CHECK GOOD.SDR R61A201905030472Unknown · malfunctionedEMERGENCY LIGHT BATTERY FAULT EICAS MESSAGE. EMERGENCY LIGHTS WON'T TURN OFF. RESET A/C POWER, PERFORMED EMERGENCY LIGHTS OPS CHECK, OPS CHECK GOOD IAW AMM 33-50-00.SDR R61A2018061210683Sensor · out of adjustON DEPARTURE, GEAR LEVER WAS LOCKED. UNABLE TO RETRACT LANDING GEAR. DECLARED AN EMERGENCY, LANDED WITHOUT INCIDENT. TROUBLESHOT AND FOUND NOSE WOFW, WOW NR 2 GAPS OUT OF LIMITS. NR 1 WOW ADJUSTED GAP TO WITHIN LIMITS. NR 2 WOW, R & R SENSOR HOLDING BRACKET SDR R61A201805160596Rib · crackedRIGHT HORIZONTAL STAB FWD OF RIB 12 HAS A CRACK AT THE UPPER SECTION.SDR R61A20180515605Bracket · corrodedBRACKET AT CROSSBEAM FRAME 16 LT CORRODED. 0.025 MATERIAL LOSS AND FOUND TO BE OUT OF LIMITS IAW SRM 51-75-16, REMOVED AND REPLACED THE BRACKET IAW SRM 51-40-08, 51-04-02SDR R61A201609050518Battery · dischargedCREW REPORTED THAT THE EMERGENCY LIGHT IN THE AFT CABIN WAS INOPERATIVE. MAINTENANCE R & R EMERGENCY BATTERY IAW AMM AND OPS CHECKED GOOD.SDR R61A201609040517Light · out of adjustCREW REPORTED THE 2ND FROM LAST EMERGENCY LIGHT WAS BLINKING ON AND OFF WITH COCKPIT CONTROL IN THE ON POSITION. MAINTENANCE PERFORMED ADJUSTMENT/TEST OF CABIN EMERGENCY LIGHTS IAW AMM AND OPS CHECKED GOOD.SDR R61A201607290443Light · malfunctionedCREW RECEIVED AN EMERGENCY BATTERY FAULT ON EICAS AND THE EMERGENCY LIGHT AT ROW 15 WAS INOPERATIVE. MAINTENANCE RESET THE LIGHT IAW FIM AND THE FAULT CLEARED. AIRCRAFT IS GOOD FOR SERVICE.SDR R61A201604180249Light · missingCREW REPORTED THAT AN 8-10" PIECE OF EMERGENCY LIGHT STRIP BY SEAT 1D WAS MISSING. MAINTENANCE REPLACED MISSING LIGHT STRIP IAW AMM AND OPS CHECKED GOOD.SDR R61A201509110628Bleed Valve · failedCREW RECEIVED A BLEED NR 2 OVER PRESSURE MESSAGE. FOLLOWED QRH, REDUCED THRUST TO IDLE AND DECLARED AN EMERGENCY. LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT, R & R ENGINE 2 NAPRSOV IAW AMM AND OPS CHECKED GOOD. ACFT IS GOOD FOR SERVICE.SDR R61A201508150591Doubler · corrodedMAJOR REPAIR, DURING HEAVY CHECK, FWD CARGO THRESHOLD AFT FINGER DOUBLER IS CORRODED. MAINTENANCE R & R FWD CARGO THRESHOLD AFT FINGER DOUBLER IAW SRM 51-43-02, PN 170-67115-002, DOUBLER.SDR R61A201508150590Doubler · corrodedMAJOR REPAIR, DURING HEAVY CHECK, FWD CARGO THRESHOLD, FWD FINGER DOUBLER IS CORRODED. MAINTENANCE R & R FWD CARGO THRESHOLD, FWD FINGER DOUBLER IAW SRM 51-40-02, PN 170-67115-001, DOUBLER.SDR R61A201508150584Seal Rest · corrodedDURING HEAVY CHECK, LOWER CENTER SECTION SEAL REST, AFT CARGO DOOR THRESHOLD IS CORRODED. MAINTENANCE R & R LOWER CENTER SECTION SEAL REST AFT CARGO DOOR THRESHOLD IAW SRM 51-40-02, 51-23-04, 51-23-06, 51-21-01. PN 170-85251-401, SEAL REST.SDR R61A201508150583Threshold · corrodedDURING HEAVY CHECK, FWD CARGO THRESHOLD CLOSING PLATE IS CORRODED. MAINTENANCE R & R FWD CARGO THRESHOLD CLOSING PLATE IAW SRM 51-43-01, 51-43-02.SDR R61A201508140600Frame · corrodedFRAME 11 FROM LBL 12" TO RBL 12" HAS AREAS OF TOP BEAM CORROSION. MAINTENANCE INSTALLED REPAIR DOUBLER IAW ETD 2015-170-079025 AND SRM 51-41-01, 51-41-02.SDR R61A201508130574Fairing · corrodedDURING HEAVY CHECK, FORWARD WING FUSELAGE TO FAIRING AFT BOTTOM FLANGE HAS 2 SCREWS DRILLED OUT AND IS CORRODED. MAINTENANCE R & R FORWARD WING FUSELAGE TO FAIRING AFT BOTTOM FLANGE IAW SRM 51-40-02, 51-40-01.SDR R61A201508110613Crossbeam · corrodedDURING HEAVY CHECK, CROSSBEAM AT FRAME 17 BETWEEN RT FUSELAGE AND SEAT TRACK 10.748 IS CORRODED. MAINTENANCE COMPLIED WITH PERMANENT REPAIR OF CROSSBEAM FRAME 17 AREA BETWEEN RT FUSELAGE AND SEAT TRACK 10.748 IAW ETD 2015-170-078655, IPM 12 AND IPM 44 FOR WOSDR R61A201508110602Frame · corrodedFRAME 84 RT SIDE OF FUSELAGE AND RT SEAT TRACK IS CORRODED. MAINTENANCE REMOVED COROSSION DAMAGE ON CROSSBEAM 84 INSTALLED LT ANGLE DOUBLER REF IPM 12, -44, AND ETD 2015-170-078385.SDR R61A201508110601Frame · chafedDURING HEAVY CHECK, FRAME 27 AT STRINGERS 5L-6L CHAFED. MAINTENANCE PERFORMED BLENDOUT AND INSTALLED REINFORCEMENT DOUBLER REFER TO IPM -12, -44 COMPLIED WITH ETD 2015-170-079439, REV A AND IPM-44 COMPLIED WITH SRM 53-22-04 REPAIR.SDR R61A201508110599Frame · corrodedDURING HEAVY CHECK, WAS REPORTED THAT FRAME 84 RT SIDE OF FUSELAGE, RT SEAT TRACK AT Y=10.748 ARE CORRODED. MAINTENANCE REMOVED CROSSBEAM 84 RT INSTALLED LT ANGLE INSTALLED AT FRAME 84 RT SIDE IAW ETD 2015--170-078385.SDR R61A201508110596Splice · corrodedDURING HEAVY CHECK, RT SPLICE AT FRAME 89 IS CORRODED. MX R & R RT SPLICE AT FRAME 89 IAW SRM 51-43-01, PN 170-86114-001, SPLICE.SDR R61A201508110595Floorbeam · corrodedDURING HEAVY CHECK, PANEL SUPPORT RT FRAME 87 IS CORRODED. MX R & R PANEL SUPPORT RT FRAME 87 IAW SRM 51-40-02, 51-41-01, PN 170-66797-001, SUPPORT.SDR R61A201508110594Floor Support · corrodedDURING HEAVY CHECK WAS REPORTED THAT LT FLOOR SILL AT FRAME 84 IS CORRODED. MAINTENANCE R & R LT FLOOR SILL AT FRAME 84 IAW SRM 51-41-01, 51-41-02, PN 170-92907-001, SILL.SDR R61A201508110593Shear Plate · corrodedDURING HEAVY CHECK, CENTER SHEAR PLATE AT FRAMES 87-88 IS CORRODED. MX R & R CENTER SHEAR PLATE AT FRAMES 87-88 IAW SRM 51-40-02, 51-42-01, PN 170-65928-001, SHEAR PLATE.SDR R61A201508110592Floor Support · corrodedDURING HEAVY CHECK, RT PANEL SUPPORT FRAME 86-90 IS CORRODED. MX R & R RT PANEL SUPPORT FRAME 86-90 IAW SRM 51-40-02, 51-23-04, PN 170-86181-005, SUPPORT.SDR R61A201508110589Shear Tie · corrodedMAJOR REPAIR, DURING HEAVY CHECK, SHEAR CLIP AT FRAME 88 BETWEEN STRINGERS 27R-28R IS CORRODED. MAINTENANCE R & R SHEAR CLIP AT FRAME 88 BETWEEN STRINGERS 27R-28R IAW SRM 51-41-01, 51-41-02, PN 170-66531-001, SHEAR CLIP.SDR R61A201508110587Floor Support · corrodedDURING HEAVY CHECK, RT PANEL SUPPORT FRAME 86-90 IS CORRODED. MAINTENANCE R & R RT PANEL SUPPORT FRAME 86-90 IAW SRM 51-43-01, 51-42-01, PN 170-86181-005, SUPPORT.SDR R61A201508110586Gusset · corrodedDURING HEAVY CHECK, RT GUSSET PLATE AT FRAME 90 IS CORRODED. MAINTENANCE R & R RT GUSSET PLATE AT FRAME 90 IAW SRM 51-41-02, 51-42-01, PN 170-60259-001, GUSSET PLATE.SDR R61A201508110585Gusset · corrodedDURING HEAVY CHECK, RT CENTER GUSSET PLATE AT FRAME 90 IS CORRODED. MAINTENANCE R & R RT CENTER GUSSET PLATE AT FRAME 90 IAW SRM 51-41-02. PN 170-60257-001, GUSSET PLATE.SDR R61A201508110582Shear Plate · corrodedDURING HEAVY CHECK, RT SHEAR PLATE AT FRAME 87-88 IS CORRODED. MAINTENANCE R & R RT SHEAR PLATE AT FRAME 87-88 IAW SRM 53-23-10, 51-40-02, PN 170-66409-001.SDR R61A201508110581Floor Support · corrodedDURING HEAVY CHECK, WAS REPORTED THAT RT FLOOR SILL AT FRAME 84 IS CORRODED. MX R & R RT FLOOR SILL AT FRAME 84 IAW SRM 170/175, 51-41-02, 51-43-02, PN 170-92908-001, SUPPORT.SDR R61A201508110580Shear Plate · corrodedDURING HEAVY CHECK, RT SHEAR PLATE, FRAME 87-88 IS CORRODED. MAINTENANCE R & R RT SHEAR PLATE FRAME 87-88, PN 170-66409-001.SDR R61A201508110579Shear Tie · corrodedDURING HEAVY CHECK, SHEAR TIE AT FRAME 87, STRINGER 27-28R FOUND CORRODED. R & R THE SHEAR TIE IAW SRM 51-41-02, 51-41-01.SDR R61A201508110578Doubler · corrodedDURING HEAVY CHECK, LT FLOOR DOUBLER FRAME 13/16 IS CORRODED. MAINTENANCE R & R LT FLOOR DOUBLER FRAME 13/16 IAW SRM 51-23-04, 51-40-02, P/N 170-2118-001, DOUBLER.SDR R61A201508110577Seat Track · corrodedDURING HEAVY CHECK, RT SEAT TRACK AT FRAME 12/20 IS CORRODED. MAINTENANCE R & R RT SEAT TRACK IAW SRM 51-41-00, 51-43-03, PN 170-03263-001, BEAM.SDR R61A201508110576Support · corrodedDURING HEAVY CHECK, SUPPORT NEXT TO RT CENTER SEAT TRACK BETWEEN FRAMES 17-18 IS CORRODED. MAINTENANCE R & R SUPPORT NEXT TO RT CENTER SEAT TRACK BETWEEN FRAMES 17-18 IAW SRM 51-40-02, 51-43-03, 51-43-04, PN 170-07304-002, BEAM.SDR R61A201508110575Support Frame · corrodedDURING HEAVY CHECK, LT PANEL SUPPORT FRAMES 88-90 IS CORRODED. MAINTENANCE R & R LT PANEL SUPPORT FRAME.SDR R61A201508110573Shear Tie · corrodedMAJOR REPAIR, DURING HEAVY CHECK, SHEAR TIE AT FRAME 87 BETWEEN STRINGERS 27-28R IS CORRODED. R & R SHEAR TIE IAW SRM 51-41-01, AND 51-41-02.SDR R61A201507280472Bleed Valve · inoperativeCREW RECEIVED A BLEED 1 LEAK MESSAGE. CREW RAN QRH, WHICH INSTRUCTED CREW TO DESCEND TO 10000 FT AND DEPRESSURIZE THE CABIN. CREW DECLARED AN EMERGENCY. PASSENGERS DID NOT BRACE AND CREW LANDED WITHOUT INCIDENT. ACFT WAS FLOWN VIA MAINTENANCE FERRY WHERE MASDR R61A201502190106Flashlight · missingCREW REPORTED THAT THE FORWARD F/A FLASHLIGHT WAS MISSING. MAINTENANCE PLACED ON MEL IAW AMM AND ACFT IS GOOD FOR SERVICE.