N108UW
Service difficulty reports · 329
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N108UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N108UW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2011070500022Floor Panel · delaminatedSAL - 2S CHECK - DELAMINATION ON FLOOR PANEL BETWEEN FR12 TO FR16, BETWEEN Y254 TO Y1734. REPLACED FLOOR PANEL BETWEEN FR12 TO FR16, BETWEEN Y254 TO Y1734 IAW A320 SRM 53-02-00 AND IRM 9701 REV G.SDR USAA2011070500004Floor Panel · corrodedSAL -S2 CHECK - CORROSION ON FLOOR PANEL BETWEEN FR66 TO FR68, STR23L. REPLACED FLOOR PANEL BETWEEN FR66 TO FR68, STR23L IAW TYPICAL REPAIR 320-2528-10-0011A.SDR USAA2011070100024Floor Panel · corrodedSAL -2S CHECK - CORROSION ON FLOOR PANEL BETWEEN FR16 TO FR20 AND BETWEEN -Y1292 TO -Y765. REPLACED FLOOR PANEL BETWEEN FR16 TO FR20 AND BETWEEN -Y1292 TO -Y765 IAW EA 133539, JOB CARD 26C22053014.SDR USAA2011062900013Sill · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON LOWER SILL AT FR19 + 3 INCHES, S23R. REPAIRED LOWER SILL AT FR19 + 3 INCHES, S23R IAW EA 133580.SDR USAA2011062900012Splice · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON FISHPLATE SPLICE AT FR30 + 17 INCHES, S41R. REPLACED FISHPLATE SPLICE AT FR30 + 17 INCHES, S41R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062900009Floor Panel · corrodedSAL - 2S - CORROSION ON FLOOR PANEL 262FF BETWEEN FR66 TO FR68, S23R. REPLACED FLOOR PANEL 262FF BETWEEN FR66 TO FR68, S23R IAW TYPICAL REPAIR 320 -2528-10-0011A.SDR USAA2011062800048Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR33 BETWEEN S43R TO S44R. REPLACED SHEAR TIE AT FR33 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11.SDR USAA2011062800040Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR33 BETWEEN S41R TO S42R. REPLACED CLEAT AT FR33 BETWEEN S41R TO S42R IAW A320 SRM 51-72-1 & AIRBUS DRAWING D53231586.SDR USAA2011062800038Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR32 BETWEEN S40R TO S41R. REPLACED SHEAR TIE AT FR32 BETWEEN S40R TO S41R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231586.SDR USAA2011062800037Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR31 BETWEEN S41R TO S42R. REPLACED SHEAR TIE AT FR31 BETWEEN S41R TO S42R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231586.SDR USAA2011062800021Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR31 BETWEEN S40L TO S41L. REPLACED CLEAT AT FR31 BETWEEN S40L TO S41L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800020Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR31 BETWEEN S40R TO S41R. REPLACED CLEAT AT FR31 BETWEEN S40R TO S41R IAW A320 SRM 51-72-1 & AIRBUS DRAWING D53231586.SDR USAA2011062800019Floorbeam · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR12 TO FR24, -Y765. REPLACED FLOORBEAM BETWEEN FR12 TO FR24, -Y765 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112812.SDR USAA2011062800015Splice Plate · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON FISHPLATE (SPLICE) AT FR30 + 17 INCHES, S24L. REPLACED FISHPLATE (SPLICE) AT FR30 + 17 INCHES, S24L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800014Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23R. REPLACED CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112198.SDR USAA2011062800013Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR33 BETWEEN S40R TO S41R. REPLACED CLEAT AT FR33 BETWEEN S40R TO S41R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231586.SDR USAA2011062800008Seat Track · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SEAT TRACK BETWEEN FR12 TO FR24, Y765. REPLACED SEAT TRACK BETWEEN FR12 TO FR24, Y765 IAW A320 SRM 51-72-11.SDR USAA2011062700026Floor Support · corrodedLEVEL 2 GALVANIC CORROSION ON FLOOR SUPPORT BETWEEN FR12 TO FR24, Y1292. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 & DRAWING D53112812.SDR USAA2011062700027Support Angle · corrodedSAL - 2S - NR # 6437468 - LEVEL 2 GALVANIC CORROSION ON SUPPORT ANGLE AT FR20, S23R. REPLACED SUPPORT ANGLE AT FR20, S23R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112784.SDR USAA2011062700024Stiffener · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON STIFFENER ASSEMBLY AT FR12 BETWEEN -Y1292 TO -Y254. REPLACED STIFFENER ASSEMBLY AT FR12 BETWEEN -Y1292 TO -Y254 IAW A320 SRM 51-72-11.SDR USAA2011062700019Floor Support · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, -Y254. REPLACED SUPPORT FLOOR BETWEEN FR12 TO FR24, -Y254 IAW A320 SRM 51-72-11& AIRBUS DRAWING D53110900 & D53111462.SDR USAA2011062700013Dummy Rail · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, -Y81. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, -Y81 IAW A320 SRM 51-72-11& AIRBUS DRAWING D53112829.SDR USAA2011062700011Angle · corrodedSAL - 2S - LEVEL 2 FILIFORM CORROSION ON ANGLE BETWEEN FR12 TO FR14, S23R. REPLACED ANGLE BETWEEN FR12 TO FR14, S23R IAW A320 SRM 51-72-11.SDR USAA2011062400026Dummy Rail · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR21 TO FR24, -Y189. REPLACED RAIL DUMMY BETWEEN FR21 TO FR24, -Y189 IAW A320 SRM 51-72-11, 51-42-11 & AIRBUS DRAWING D53111414.SDR USAA2011062400024Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23L. REPLACED CENTER FITTING BETWEEN FR16 + 7 INCHES TO FR19 + 5 INCHES, S23L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53112175.SDR USAA2011062400022Floor Support · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254. REPLACED SUPPORT FLOOR BETWEEN FR12 TO FR24, Y254 IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53110900.SDR USAA2011062400021Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR32 BETWEEN S43R TO S44R. REPLACED SHEAR TIE AT FR32 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062400005Dummy Rail · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON RAIL DUMMY BETWEEN FR12 TO FR16, S23R. REPLACED RAIL DUMMY BETWEEN FR12 TO FR16, S23R IAW A320 SRM 51-72-11.SDR USAA2011062400003Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR19 + 6 INCHES, S23L. REPLACED PLATE AT FR19 + 6 INCHES, S23L IAW A320 SRM 51-72-11.SDR USAA2011062400002Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR16 + 4 INCHES, S23L. REPLACED PLATE AT FR16 + 4 INCHES, S23L IAW A320 SRM 51-72-11.SDR USAA2011062400001Plate · corrodedSAL - S2 - LEVEL 2 GALVANIC CORROSION ON PLATE AT FR16 + 3 INCHES, S23R. REPLACED PLATE AT FR16 + 3 INCHES, S23R IAW A320 SRM 51-72-11.SDR USAA2011070100023Fitting · corrodedSAL - 2S CHECK - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR30 BETWEEN STR40R TO STR41R. REPLACED CLEAT AT FR30 BETWEEN STR40R TO STR41R IAW A320 SRM 51-72-11 AND AIRBUS DRAWING D53231712.SDR USAA2011070100014Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR27 BETWEEN S43R TO S44R. REPLACED CLEAT AT FR27 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800044Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR28 BETWEEN S43R TO S44R. REPLACED CLEAT AT FR28 BETWEEN S43R TO S44R IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800018Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR30 BETWEEN S40L TO S41L. REPLACED CLEAT AT FR30 BETWEEN S40L TO S41L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062800017Fitting · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT AT FR26 BETWEEN S41L TO S42L. REPLACED CLEAT AT FR26 BETWEEN S41L TO S42L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011062400028Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON CLEAT (SHEAR TIE) AT FR30 BETWEEN S41R TO S42R. REPLACED CLEAT (SHEAR TIE) AT FR30 BETWEEN S41R TO S42R IAW A320 SRM 51-72-11.SDR USAA2011062400023Shear Tie · corrodedSAL - 2S - LEVEL 2 GALVANIC CORROSION ON SHEAR TIE AT FR29 BETWEEN S40L TO S41L. REPLACED SHEAR TIE AT FR29 BETWEEN S40L TO S41L IAW A320 SRM 51-72-11 & AIRBUS DRAWING D53231712.SDR USAA2011070100020Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON RUDDER HINGE FITTING NR 2 AT RS1926, RIB 4. REPLACED RUDDER HINGE FITTING NR 2 AT RS1926, RIB 4 IAW A320 AMM 55-36-41.SDR USAA2011070100019Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON RUDDER HINGE FITTING NR 4 AT RS2632, RIB6. REPLACED RUDDER HINGE FITTING NR 4 AT RS2632, RIB 6 IAW A320 AMM 55-36-41.SDR USAA2011070100018Hinge Fitting · excess playSAL - 2S CHECK - EXCESSIVE PLAY ON NR 5 RUDDER HINGE FITTING AT RS2985, RIB 7. REPLACED NR 5 RUDDER HINGE FITTING AT RS2985, RIB7 IAW A320 AMM 55-36-41.SDR USAA2010083091848Blanking Plate · leakingFLT 779 PHL - TPA - IFSD - NR 2 ENGINE FAILED AT 5000 FT ON CLIMBOUT. UNABLE TO RESTART - RETURNED TO PHL. MX FOUND FUEL LEAKING FROM BURNER STAGING VALVE BLANKING PLATE. REPLACED PLATE IAW MM 73-11-70-04.SDR USAA2010072691489Lens · missingFLT 759 - ORD - EEL - EMERGENCY EXIT LENS COVER MISSING AT 11C. MAINTENANCE INSTALLED MISSING LENS AT 11C.SDR USAA2010012590175Power Supply · faultyFLT 789 - FLL - EEL - EMEREGENCY POWER SUPPLY UNIT 'EXT LOAD EMER R' FAULT. ALL EXTERNAL EMERGENCY LIGHTS OPS CHECKED NORMAL AT THIS TIME. MAINTENANCE REPLACED POWER SUPPLY UNIT 12WL PER AIRBUS MAINTENANCE MANUAL 33-51-38-000-001 & 33-51-38-400-001.SDR USAA2009052691290Fitting · crackedPIT - TRIPLE GEAR CHANGE - MAJOR REPAIR - JOB CARD JA-900-09000-13 - CRACK ON SKIN CLIP AT FR73 BETWEEN S31L TO S33L. REPAIRED SKIN CLIP AT FR73 BETWEEN S31L TO S33L IAW A320 SRM 51-72-11.SDR USAA2009052191248Cylinder · low pressureN/R 6140331, WEEKLY CK - PIT - EMERGENCY EQUIPMENT - L1 DOOR ASSIST BOTTLE LOW PRESSURE. SERVICED L1 DOOR EMERGENCY ASSIST BOTTLE PER AIRBUS MAINTENANCE MANUAL 52-10-00-03.SDR USAA2009051491171Fitting · crackedPIT - HMV GEAR CHANGE - MAJOR REPAIR - LEFT WING RIB 5 FITTING CRACKED. REPLACED LEFT WING RIB 5 FITTING IAW US AIRWAYS EA 112642.SDR USAA050854Floorbeam · corrodedPIT - FOUND BEAM CORRODED .5 INCH BY 3 INCH AREA, FLOORBEAM Y254 BETWEEN CROSSBEAMS C-16 AND C-20. REMOVED AND REPLACED WITH NEW PART PER SRM 53-11-14 FIG 202. CORROSION LEVEL 1, TASK JA-222-53500. (M)SDR USAA050855Floorbeam · corrodedFOUND FLOORBEAM CORRODED 21 HOLES WITH 1 INCH OF CORROSION, FRAME 66-68 FLOORBEAM Y1292. REMOVED AND REPLACED PER SRM 53-00-15 FIG 201. (M)SDR USAA050856Floor Support · corrodedPIT - FOUND FLOOR SUPPORT CORRODED 1 INCH IN DIAMETER IN SEVERAL SPOTS, Y1292 BETWEEN C16 AND C20. DEFECTIVE PART REPLACED WITH IDENT PART NR. (M)
Back to N108UW