N121UP
Service difficulty reports · 244
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N121UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N121UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA10160445Floor Panel · damagedINSPECTION TYPE:10YR EDGE DAMAGE F/B NR 151UF AFT CARGO. FABRICATED AFT CARGO FLOOR PANEL NR 151UF IAW EO A300-5320-16407-D, APPENDIX C.SDR IPXA10160691Stringer · shearedINSPECTION TYPE:10YR, AFT UNDERFLOOR COMPT STR 40R IS SHEARED JUST AFT OF FR 73. ACCOMPLISHED REPAIR IAW SRM 53-10-14, PARA 5, FIG 208.SDR IPXA10160690Stringer · shearedINSPECTION TYPE:10YR, AFT UNDERFLOOR COMPT STR 39R IS SHEARED JUST AFT OF FR 73. ACCOMPLISHED REPAIR IAW SRM 53-10-14, PARA 5, FIG 208.SDR IPXA10160689Skin · damagedINSPECTION TYPE:10YR, EXTERIOR FUSELAGE SKIN IS DAMAGED AR FR 73 TO FR 74 BETWEEN STR 38R AND STR 41R. ACCOMPLISHED REPAIR IAW SRM 53-10-12 PAR 13, FIG 210.SDR IPXA10161016Structure · damagedINSPECTION TYPE:10YR, IMPACT DAMAGE TO RT INBD T/E FLAP OTBD T/E. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR IAW EA 300-5753-01-A2458 I/R AND UPS EO A300-5750-38674-A.SDR IPXA10158341Light · inoperativeEVACUATION SLIDE DOOR LIGHT INOP - BUZZER OK. (DEFERRED 418031) PERFORMED TEST IAW AMM 52-73-00-06. OPS CHECKS GOOD. THIS CLEARS M418031.SDR IPXA09156842Isolation Valve · malfunctionedINSPECTION TYPE:N/A CREW ADVISED, LOST CENTER HYDRAULIC (GREEN) SYSTEM. CREW DECLARED EMERGENCY AND PERFORMED MANUAL GEAR EXTENSION; LANDED WITHOUT INCIDENT. REPLACED GREEN SYS ISOLATION VALVE BLOCK PER AMM 27-14-21-04.SDR IPXA09156467Skin · misrepairedINSPECTION TYPE:1C REPAIR SURVEY SEQ W4-02 RIGHT I/B FLAP UPPER SKIN REPAIR FOUND TO HAVE A DISCREPANT FASTENERS INSTALLED AT RIB 1C. REMOVED EXISTING DISCREPANT FASTENERS FROM RT WING, INNER FLAP, UPPER SKIN BETWEEN RIB 1C-3 AND STR 2.1-2.2 AND REPLACED WITHSDR IPXA09156457Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161HF, HAS PREVIOUS REPAIR THAT WAS NOT SIGNED OFF TO A EO THAT CONTAINS SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 161HF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156454Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161GF HAS PREVIOUS REPAIR THAT SIGNED OFF TO AN EO THAT CONTAINS NO SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 161GF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156453Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 241LN HAS SEVERAL PUNCTURES. FABBED FLOOR PANEL 241LN IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156452Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL162HF HAS PREVIOUS REPAIR THAT WAS SIGNED OFF TO AN EO THAT CONTAINS NO SPECIFIC REPAIR PROCEDURES. FABBED FLOOR PANEL 162HF IAW IPXA EO A300-5320-16407-C, APPX D.SDR IPXA09156451Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 232SG, HAS SEVERAL PUNCTURES. FABBED FLOOR PANEL 232SG IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156449Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 232EF, HAS HOLES ON THE FIELD REPAIR. FABBED FLOOR PANEL 232EF IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156448Floor Panel · misrepairedINSPECTION TYPE:4/C VALIDATION SURVEY BULK CARGO PIT FLOOR PANEL 161JF HAS PREVIOUS REPAIR THAT IS NOT COVERED BY APPROVED STRUCTURAL REPAIR PROCEDURE. FABBED FLOOR PANEL 161JF IAW IPXA EO A300-5320-1647-C, APPX D.SDR IPXA09156447Floor Panel · damagedINSPECTION TYPE:4/C MAIN CABIN FLOOR PANEL 242 LJ FIELD REPAIR HAS HOLES. FABBED FLOOR PANEL IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156461Floor Panel · damagedINSPECTION TYPE:4/C FLOOR PANEL 132DE IS MISSING INSERTS AND DELAMINATED. FABBED FLOOR PANEL 132DE IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156456Floor Panel · damagedINSPECTION TYPE:4/C VALIDATION SURVEY FWD CARGO PIT FLOOR PANEL 132PG HAS PREVIOUS REPAIR INSTALLED THAT IS NOT COVERED BY AN APPROVED SRM. FABBED FLOOR PANEL 132PG IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156455Floor Panel · damagedINSPECTION TYPE:4/C FLOOR PANEL 132AH IS MISSING INSERTS AND DELAMINATED. FABBED FLOOR PANEL 132AH IAW IPXA EO A300-5320-16407-C, APPX C.SDR IPXA09156450Floor Panel · misrepairedINSPECTION TYPE:4/C VALIDATION SURVEY PANEL 242 WK CARGO MAIN FLOOR PANEL HAS PREVIOUS REPAIR NOT COVERED BY AN APPROVED SRM. FABBED FLOOR PANEL 242WK IAW IPXA EO A300-5320-16407-C, APPX B.SDR IPXA09156477Skin · chafedINSPECTION TYPE:4C LT WING INBOARD FLAP UPPER SURFACE CHAFED, AFT OF NR 1 SPOILER. REMOVED DAMAGE AND FABRICATED AND INSTALLED REPAIR DOUBLER PER E0-A30 0-5750-34048-A.SDR IPXA09156468Skin · gougedINSPECTION TYPE:1C REPAIR SURVEY SEQ F1-04 REPAIR REQUIRES REPLACING DUE TO GOUGES IN PREVIOUS REPAIR DOUBLER. REMOVED EXISTING REPAIR AND DAMAGE, FABRICATED AND INSTALLED REPLACEMENT REPAIR AT FR 84-86 AND STR 43L-44R REF EO A300-5330-34033-A AND E A 300-533SDR IPXA09156446Skin · gougedINSPECTION TYPE:4/C LEFT WING CENTER FLAP UPPER SURFACE GOUGED APPROX 18 INCHES ABOVE RUB TRIP O/B OF NR 3 FLAP TRACK. FABBED AND INSTALLED REPAIR DOUBLER IAW IPXA EO A300-5750-34021-A, AND SAA EA 300-5753-01-A1859.SDR IPXA09155192Skin · gougedINSPECTION TYPE:N/A RT WING T/E FLAP GOUGED ON LOWER SURFACE. COMPLETED REPAIR PER EO A300-5750-32923A & A300 SRM 57-50-00-20.SDR UPS09154734Light · inoperativeINSPECTION TYPE:N/A LOWER LAV EMERGENCY LIGHT INOP. RELAMPED LIGHT, OPS CHECK GOOD.SDR UPS08153433Light · inoperativeINSPECTION TYPE:N/A LAV MIRROR EMERGENCY LIGHT OUT. RELAMPED & OPS CHECKED GOOD PER IPC 33-51-21-02.SDR UPS08152684Outflow Valve · failedAFTER T/O AT 1,000', PRESSURE REGULATOR NR1 FAILED. REMOVED AND REPLACED FWD CABIN PRESSURE OUTFLOW VALVE IAW MM 21-31- 12-04.SDR UPS07149234Warning Light · inoperativeINSPECTION TYPE:N/A FWD ENTRY DOOR ESCAPE SLIDE ARM WARNING LIGHT IS INOP. CLEANED AND RESEATED THE CONNECTOR ON THE AUTONOMOUS STANDBY POWER SUPPLY UNIT 70WN AS REQUIRED. WARNING LIGHT OPS CHECKS GOOD. OK FOR SERVICE.SDR UPS06146418Oxygen Mask · no testCAPT'S 02 MASK W/NOT TEST. REMOVED AND REPLACED CAPT QUICK DONNING 02 MASK AND PLACED W/SERVICEABLE 02 MASK IAW A300-680 AMM 35-12-54-4.SDR UPS05144963Bracket · crackedINSPECTION TYPE: 5YR, AFT CARGO PIT, CENTER UPPER ANGLE STRUCTURE IS CRACKED. REMOVED & REPLACED ANGLE BRACKET IAW A300-600 SRM 51-40-21.SDR UPS05144962Bracket · crackedINSPECTION TYPE: 5YR, AFT CARGO PIT, UPPER RIGHT ANGLE STRUCTURE IS CRACKED. REMOVED & REPLACED ANGLE BRACKET IAW A300-600 SRM 51-40-21.SDR UPS05144961Bracket · crackedINSPECTION TYPE:5 YR AFT CARGO PIT, AFT BULKHEAD, UPPER LEFT ANGLE STRUCTURE IS CRACKED. REMOVED & REPLACED ANGLE BRACKET IAW A300-600 SRM 51-40-21.SDR UPS05144964Angle · crackedINSPECTION TYPE: 5YR, LEFT WING INSIDE KRUGER FLAP WELL, CURVED SUPPORT STRUCTURE IS CRACKED IN RADIUS OF 2ND RIB. REMOVED & REPLACED SUPPORT STRUCTURE ANGLE IAW A300-600 SRM 51-40-00.SDR UPS05144680Connector · dirtyMAIN ENTRY DOOR SLIDE LT INOP. CLEANED CONNECTOR TO ASPSU OPS GOOD PER MM 52-73-18-04.SDR UPS05144024Light · will not testINSPECTION TYPE:N/A EMERGENCY EXIT LIGHTS DON'T TEST PROPERLY. RELAMPED LIGHT ASSY OVER L1 DOOR, CHECKS OK.SDR UPS04143034Light · inoperativeLAV EMERGENCY LIGHT INOP. RELAMPED LAV EMERGENCY LIGHT.SDR UPS04142924Connector · damagedON MAIN ENTRY DOOR RED LIGHT WILL NOT TEST. FOUND PIN -C- AT CONNECTOR 1587 PUSHED BACK. SEATED PIN, CHECKS NORMAL AMM 52-73-00-5. PLACARD REMOVED.SDR UPS04142829Indicator · inoperativeCREW ENTRY DOOR ESCAPE SLIDE INDICATOR INOP. REMOVED AND REPLACED ASPSU IAW 52-73-16-4, OPS CHECK NORMAL ON GROUND. PLACARD WAS REMOVED. CLEARED DEFERRAL M285209.SDR UPS04142862Slide · inoperativeL1 DOOR ESCAPE SLIDE AND LIGHT INOP. PLACED ON MEL 52-73-01-1 M285209 ASSIGNED. PART ORDERED. BUZZER OPS NORMAL.SDR UPS04142816Switch · inoperativeMAIN ENTRY DOOR SLIDE WILL NOT ARM, REF M384898. REMOVED AND REPLACED FWD CARGO COMPT ENTRY DOOR SLIDE ARM SWITCH. SYS OPS CK NORMAL.SDR UPS04142543Slide · will not armINSPECTION TYPE:N/A DIFFICULTY IN ARMING MAIN ENTRANCE DOOR SLIDE. COULD NOT GET SLIDE ARMED INDICATION UNTIL AFTER REPEATED ATTEMPTS. PERFORMED DOOR EMERGENCY SLIDE ARMING ADJUSTMENT AND TEST PER MM 52-73-00-5, OPS CHECK GOOD.SDR UPS04141792Oxygen Mask · inoperativeCREW AND ALL JUMPSEAT OXYGEN MASKS WILL NOT TEST. FOUND NR 1 COURIER MASK NOT STOWED. RESTOWED ALL MASKS, CHECK OK. NR 1 COURIER 02 MASK INOP. ENTERED DEFERRAL M274961 MEL 35-31-01 PLACARD INSTALLED, SEAT MUST BE UNOCCUPIED. REPLACE 02 MASK PER MM TESTS OSDR UPS05145889Hydraulic Line · brokenINSPECTION TYPE: N/A GREEN SYS RSVR LOW LEVEL WARNING CAME ON IN FLT FOLLOWED ALL ECAM PROCEDURES AND CHECK LIST. **** SUPPLEMENTAL MRR **** REPAIRED HYD LINE NEAR GREEN SYS SERVO CONTROL UNIT IAW M/M 20-23-11-0. LEAK CHECKS OK. SERVICED GREEN SYSTEM RES.SDR UPS02137490Diaphragm · puncturedINSPECTION TYPE:IN FWD DOOR EMERGENCY OPERATION CYLINDER SEALING DIAPHRAGM HAS BEEN PUNCTURED ITEM DEF M230237. INSTALLED NEW DIAPHRAGM AND SERVICE DOOR DAMPER CYLINDER PER A300 MM CH 52-10-14. CHANGED O-RINGS AND SERVICED PER A300 MM 52-10-14. THIS CLEARS
Back to N121UP