N122UA
Service difficulty reports · 353
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N122UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N122UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012042302401Lamp · inoperativeZONE B CEILING EMERGENCY LIGHT NEAR SEAT ROW 8HG IS INOPERATIVE. REPLACED LAMP AND CHECKED NORMAL.SDR UALA2012042302400Lamp · inoperativeZONE B CEILING EMERGENCY LIGHT NEAR SEAT ROW 6HG IS INOPERATIVE. REPLACED LAMP, CHECKED NORMAL.SDR UALA2012041202214Guard · out of adjustEXIT PLACARD SIGN LOCATED ON WALL AFT OF DOOR 4R FLASHES ON AND OFF. ADJUSTED GUARD ON EMERGENCY LIGHT SWITCH AT DOOR 1L. OPS NORMAL.SDR UALA2012031201608Charger · inoperativeLEFT OVERWING FWD TWO EMERGENCY LIGHT ASSY IS INOP. REPLACED AND SECURED BATTERY CHARGER AT DOOR 3 LEFT, CHECKS NORMAL.SDR UALA2012031201603Light · inoperativeUPPER DECK EMERGENCY LIGHT AT SEAT 14AB IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201602Light · inoperativeUPPER DECK EMERGENCY LIGHT AT SEAT ROW 13A IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201607Light · inoperativeSEAT ROW 51 ABC EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201606Light · inoperativeUPPER DECK CEILING EMERGENCY LIGHT NEAR TOP OF STAIRS IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201605Light · inoperativeUPPER DECK CEILING EMERGENCY LIGHT NEAR SEAT ROW 17 IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201604Light · inoperativeUPPER DECK CEILING EMERGENCY LIGHT NEAR SEAT ROW 15 IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201601Light · inoperativeUPPER DECK CEILING EMERGENCY LIGHT NEAR SEAT ROW 13 IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012031201600Light · inoperativeFLT DECK CEILING EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2012011900397Smoke Detector · faultyLAV 111 SMOKE DETECTOR SOUNDED WITH NO SMOKE. NO GREEN LT ILLUM STOPPED SOUND BUT AGAIN. RPLD SMOKE DETECTOR PER MM 26-13-01 P401 AND TEST OK. TEST PER MM 26-13-00. CHKD AND FOUND NO FIRE, NO SMOKE IN LAV 111.SDR UALA2012011300286Unknown · leakingFIRST OFFICER'S FWD RT WINDOW SQUEALING. SOUND COMING FROM LWR FWD CORNER. CHECKED SEALANT CONDITION AROUND NR 2 WINDOW. SEALANT CONDITION CHECKED OKAY. NO DISCREPANCY FOUND.SDR UALA2011121906933Seal · dirtyPER CREW REPORT, SOUND LIKE POSSIBLE PRESSURE LEAK TOP-FWD EDGE RT UPPER DECK DOOR. CHECKED AND CLEANED SEAL AND AROUND DOOR SEAL AREA. NEED TO DO PRESSURE LEAK CHECK. PRESSURIZED ACFT TO 2.2 DIFF. PSI HAS AIR LEAK AND SLIGHT WHISTLE. CLEANED AREA APPLIEDSDR UALA2011122107032Window · crackedWINDOW 2R SHOWS SIGNS OF WATER INGRESS AND CRACKING. REMOVED WINDOW. PARTS AND HARDWARE TAGGED AND BAGGED IN COCKPIT. NEW WINDOW 2R IN PLACE BOLTS INSTALLED WET SOME NUTS INSTALLED PER MM.SDR UALA2011121906966Heater · faultyWINDOW 3R HEAT FAIL DISPLAYED 5 OUT OF 5 LEGS (MSG 30123) ACCOMPLISHED INSTALLATION OF WINDOW 3R REF AMM. WINDOW HEAT OPS NORMAL PER MM.SDR UALA2011121906990Light · inoperativeEEL ON CEILING ABOVE STAIRWAY TO UPPER DECK IS INOP. RELAMPED OP CHECK OK.SDR UALA2011121906989Light · inoperativeEEL UPPER DECK AT SEAT 16 IS INOP. RELAMPED OP CHECK OK.SDR UALA2011121906988Light · inoperativeEEL CEILING LIGHT IN UPPER DECK BETWEEN ROW 16 IS INOP. RELAMPED OP CHECK OK.SDR UALA2011121906987Light · inoperativeEEL CEILING LIGHT IN UPPER DECK BETWEEN ROW 15 IS INOP. RELAMPED OP CHECK OK.SDR UALA2011121906986Light · inoperativeEEL CEILING LIGHT IN UPPER DECK IN ROW 13 IS INOP. RELAMPED OP CHECK OK.SDR UALA2011121906985Light · inoperativeEEL CROSSOVER LIGHT IN AFT GALLEY NEAR DOOR 5L IS INOP. REPLACED CROSS OVER EEL LAMP IN AFT GALLEY NEAR 5L, OPS CHECK NORMAL.SDR UALA2011121906984Light · inoperativeEEL AT SEAT 33 ABC IS INOP. REPLACED EEL LIGHT AT SEAT 33 ABC, OPS CHK NORMAL.SDR UALA2011121906983Light · inoperativeEEL AT SEAT 19 ABC IS INOP. REPLACED EEL AT SEAT 19 ABC, OPS CHK NORMAL.SDR UALA2011113006577Hose · leakingCREW REPORT: RUNNING WATER LEAK INSIDE LAV 105 REF DF872 WATER SOV SHOULD ALREADY BE IN OFF POSITION. SAMC TEXT: F/O CONFIRMED SOV IS IN THE OFF POSN, WATER STILL LEAKING. MAINT PLZ DEBRIEF FLT CREW UPON LANDING. :REF PTT 5432015 AND 5432016 FOR HOSES REPSDR UALA2011110906126Squib · faultyDURING TEST ON JOB8-8401 FIRE EXT BOTTLE SQUIB CHECK, ON STEP 12 TEST2 ENG 4 SQUIB LIGHT DID NOT COME ON. REPLACED NR 4, SYS 'B' SQUIB PER MM.SDR UALA2011110906125Light · inoperativeEMERGENCY LIGHT DOOR 2L GALLEY MID WALL INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011110906124Light · inoperativeEMERGENCY CEILING LIGHT FLIGHT DECK INOP. RELAMPED OP CHECK NORMAL.SDR UALA2011090904874Light · brokenEMERGENCY LIGHT STRIP AT 20H IS BROKEN. REPLACED AND TESTED STRIP AS PER A-C MM, ALL OPS NORMAL.SDR UALA2011082604562Plate · contaminatedECONOMY GALLEY HOT PLATE 162 HAS PLASTIC MELTED ON IT, NEEDS CLEANING. MECHANIC CALLED CABIN CLEANING CREW TO CLEAN PLASTIC OFF HOT PLATE. OP CHECK ACP BY FLIGHT ATTENDANT.SDR UALA2011082204453Light · shortedEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 45 THRU 53 RIGHT. FOUNDED SHORT LAMP AT ROW 50HJK. REPLACED LAMP, CHECKS NORMAL.SDR UALA2011082204452Battery Pack · dischargedEMERGENCY EXIT EELS VERY DIM SEAT ROWS 33 THRU 43 LEFT. REPLACED FLOOR EMERGENCY LIGHT BATTERY PACK. CHECKS NORMAL.SDR UALA2011082204451Battery · dischargedEMERGENCY EXIT EEL LIGHTS INOP SEAT ROWS 23 THRU 25 RT LWR WALL ACROSS DOOR 3R & LWR WALL BETWEENN LAVS 111 & 112. REPLACED FLOOR EMERGENCY LIGHT BATTERY AT DOOR 3 RIGHT. CHECKS NORMAL.SDR UALA2011082204450Light · inoperativeEMERGENCY EXIT LIGHT INOP FWD STAIRS CEILING STAIRWELL. RELAMPED 2EA, CHECKS NORMAL.SDR UALA2011082204449Light · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE CEILING FLIGHT DECK. RELAMPED, CHECKS NORMAL.SDR UALA2011082204448Connector · looseEMERGENCY EXIT EEL LIGHT INOP AT DOOR 4 LEFT GALLEY AREA LOWER WALL CROSS-AISLE IN GALLEY. SECURED CONNECTOR, OPS CHECKS NORMAL.SDR UALA2011082204447Oxygen Mask · brokenDURING ROUTINE MAINTENACE, FOUND FIRST OFFICERS OXYGEN MASK TO BE BROKEN. REPLACED F/O OXYGEN MASK IAW MM.SDR UALA2011081504275Light · malfunctionedFLOOR EMERG EXIT LIGHT STRIP ACROSS FROM LAV 1L FLICKERS. CYCLED EMERG LIGHTS IN ALL POS. NO IND OF FLICKERING ACROSS FROM LAV 1L AT THIS TIME. OK FOR SERVICE.SDR UALA2011081504274Light · malfunctionedEMERGENCY EXIT LIGHT FLICKERS AT LAV 2L. CYCLED EMER LIGHTS IN ALL POS. NO IND OF FLICKERING ACROSS FROM LAV 2L AT THIS TIME. OK FOR SERVICE.SDR UALA2011080804114Connector · unsecureEMERGENCY LIGHTS FLASH INTERMITTENT AT DOOR 2 LEFT. CONNECTOR SECURED AND EMERGENCY LIGHT CHECKED OKAY.SDR UALA2011080103969Wire · damagedF/O UNABLE TO TRANSMIT WITH MINITEL. PIGGYBACKED A WIRE FROM THE WIU WE THOUGHT WAS INTERMITTENT. NO JOY. FOUND WIRE OPEN. WIRE ON Y6680 CONFIRMED WIRE ETA 1430.SDR UALA2011062103052Battery · faultyBAT CHARGER APU STATUS. REPLACED APU BATTERY.SDR UALA2011062103045Light · inoperativeEMERGENCY LIGHT ROW 37 LT INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011062103044Light · unsecureMAIN AFT GALLEY EMERGENCY LIGHT ALONG WALL INOP. RESECURED EMERGENCY LIGHT. OP CHECK NORMAL.SDR UALA2011062103043Connector · disconnectedEMERGENCY LIGHT ROW 45 THROUGH 53 INOP LT. RECONNECT EMERGENCY LIGHT ALONG MAIN GALLEY WALL. OP CHECK NORMAL.SDR UALA2011062103042Connector · unsecureEMERGENCY LIGHT ROW 41 RT INOP. RESECURED EMERGENCY LIGHT CONNECTOR. OP CHECK NORMAL.SDR UALA2011062103041Light · inoperativeEMERGENCY CEILING LIGHT ROW 15 INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011060602782Battery · faultyBAT CHARGER APU, STATUS. REPLACED APU BATTERY PER MM. ALL OPS NORMAL.SDR UALA2011051102349Connector · saturatedEMERGENCY LT INOP: DOOR 4R AFT EEL EXIT SIGN. DRIED AREA AT GLY FLOOR, CHECKS OK.