N126UP
Service difficulty reports · 233
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N126UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N126UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2023060693383Bracket · crackedINSPECTION TYPE:1CAFT CARGO FR 54 BRACKET AT - Y953 RH CRACKED.REMOVED AND REPLACED IAW SRM 51-40-21.SDR IPXA2023060693382Bracket · crackedINSPECTION TYPE:1CAFT CARGO FR 54 BRACKET AT-Y953 LH CRACKED.REMOVED AND REPLACED IAW SRM 51-40-21.SDR IPXA2022031680177Door · noneINSPECTION TYPE:NALOCKING PIN MISSING FOR MAIN CREW ENTRY DOORREPLACED MISSING PIN WRT A300 AMM 52-73-00SDR IPXA2022012078061None · noneINSPECTION TYPE:NA**SUPPLEMENTAL SDR **SLIDE PRESSURE NOT IN GREEEN BAND. DEFERRED L1 DOOR SLIDE IAW MEL 52-11-01-2-3REPLACED DOOR SLIDE AS PER AMM 25-61-21-0401 EMERGENCY OP CYL AND DOOR WARNING SYSTEM ARMED/CHECKED. DMP WAS NOT APPLICABLE AS PER 52-11-01-2-3SDR IPXA2021081072610Interphone · failedATB* EMERG DECL'D*HAZMAT INFO WAS SENT* A/C LANDED WITHOUT INCIDENT*A/C OOS* - WITH GEN #2 DEFFERED. APU FAILED AT 100 FT ON TAKEOFF. EMERGENCY DECLARED TO KMCO. R/R IDG & INTERPHONE BOX.TROUBLESHOT PER AMM 49-62-00 SCH 1 PG 101. THIS CLEARS M752897SDR IPXA2021072872222Girt Bar · dirtyINSPECTION TYPE:NACREW REPORTED DIFFICULITY IN DISARMING DOOR SLIDE.CLEANED AND LUBED GIRT BAR AND ALL ASSOCIATED LINKAGES PER AMM 12-22-52-0001. OPS CHECK GOOD PER AMM 25-61-21-0401SDR IPXA2021070971452Former · crackedINSPECTION TYPE:CLH WING LE KRUEGER FLAP FORMER I/B CUTOUT IS DAMAGED.REMOVED AND REPLACED FORMER PER SRM 51-40-21.SDR IPXA2021070971451Stiffener · crackedINSPECTION TYPE:CLH WING LE KRUEGER FLAP STIFFENER I/B CUTOUT IS DAMAGED.REMOVED AND REPLACED STIFFENER PER SRM 51-40-21.SDR IPXA2021062771011Fitting · crackedINSPECTION TYPE:A300CENTER FUSELAGE FRAME BASE FITTING STR. 36 FR45 L/H CRACKED.REPAIR IAW A300-5310-46789-G APPENDIX J.SDR IPXA2021070271226Frame · crackedINSPECTION TYPE:A300LH FR 40 LOWER JUNCTION MIDDLE FASTENERS HOLE CRACKS 9 O CLOCK POSITIONREPAIR HOLE PER EA A300-5710-27-A2619 STEPS 1-14SDR IPXA2021070471250Frame · crackedINSPECTION TYPE:CFRAME 40 UPPER UNCTION BOTTOM HOLE HAS CRACK INDICATION FOUND DURING ROTARY PROBE 6 O'CLOCK POSITIONREPAIRED IAW EA 300-5710-A2622 STEPS 1-35SDR IPXA2021070471249Frame · crackedINSPECTION TYPE:CLH FR 40 UPPER JUNCTION MIDDLE FASTENER HOLE CRACKS 2 O'CLOCK POSITIONREPAIR HOLE PER EA 300-5710-27-A2622 STEPS 1-35SDR IPXA2021070471248Frame · crackedINSPECTION TYPE:CFRAME 40 L/H UPPER JUNCTION TOP HOLE HAS CRACK INDICATION FOUND DURING ROTARY PROBE 2 O'CLOCK POSITIONREPAIRED IAW EA 300-5710-A2622 STEPS 1-35SDR IPXA2021062871077Access Panel · crackedINSPECTION TYPE:A300ACCESS, PANEL 424AR EXTERNAL SURFACE WITH DENTREMOVED AND REPLACED 424AR P/N A7521502500300 IAW AMM 54-52-61-04-01SDR IPXA2021062370911Panel · crackedINSPECTION TYPE:A300PANEL RACK PANEL 413BL HAS A CRACKREPAIRED IAW 54-52-51-PARA 5.E FIGURE205SDR IPXA2021062170849Rub Strip · crackedINSPECTION TYPE:A300 LT WING CENTER FLAP L/E TOP SURFACE ROLLER RUB PLATE CRACKEDREMOVED,FABRICATED,AND INSTALLED IAW A300 SRM 51-40-21 AND 57-53-12SDR IPXA2021061870748Bracket · crackedINSPECTION TYPE:CLT WING BELOW #3 SPOILER I/B END RIB INTER-COSTAL FWD BRACKET CRACKED.REMOVED AND REPLACED IAW SRM 51-40-21SDR IPXA2021061870749Spar · crackedINSPECTION TYPE:A300DURING ROTO OF LH WING FR47 FASTENER HOLES PER EO A300-5710-68606-G A CRACK INDICATION WAS NOTED IN HOLE D.REPAIRED IAW UPS EO A30-5710-80684-ASDR IPXA2021032367170Blower · inoperativeINSPECTION TYPE:N/ALH EVAS FAILS BLOWER CHECKLH EVAS UNIT REPLACED OPS CK GOOD. REF:AMM 25-69-00.SDR IPXA2020113062955Jackscrew · contaminatedEMERGENCY DECLARED, NO EQUIP USED. A/C WAS OUT OF SERVICE. DURING APPROACH GOT SLATS SYS 1 & SYS 2 FAULT. FOLLOWED QRH. T/S SLAT SYS, PER TSM 27-80-02. BOTH SFCC'S FLGING JAM. FOUND LT SLAT TORQ LIMIT TRIPPED & NR 3 SCREWJACK ACT TRIPPED. PERFORMED OIL SDR IPXA2020071057614Skin · corrodedINSPECTION TYPE:SEG, CENTER FUEL TANK LOWER EXTERNAL SKIN L/H FRAM FWD AREA HAS CORROSION, EA 300-5710-27-A-2476 REV: PREM 3SDR IPXA2020071057612Fuel Tank · corrodedINSPECTION TYPE:SEG, CENTER FUEL TANK LOWER EXTERNAL SKIN LT FRAM FWD AREA HAS CORROSION. EA 300-5710-27-A2476 REV: PREM 3SDR IPXA2020071057611Fuel Tank · corrodedINSPECTION TYPE: SEG, CENTER FUEL TANK EXTERNAL SKIN L/H FRAME FWD AREA HAS CORROSION, EA 300-5710-27-A2476 REV: PREM 3SDR IPXA2020070757475Skin · dentedINSPECTION TYPE:SEGR/WING I/B FLAP LOWER SURFACE HAS SEVERAL DENTSREPAIRED PER EA 300-5750-27-A2474 & SRM 57-52-12-001, FIG 3, LHT3.SDR IPXA2020070357293Longeron · damagedINSPECTION TYPE:SEG NR 2 PYLON FAIRING 485AL MIDDLE LONGERON HAS ELONGATED HOLES IN ATTACH FLANGE. REMOVED AND INSTALLED NEW LONGERON IAW SRM 51-40-21.SDR IPXA2020070357292Skin Panel · chafedINSPECTION TYPE:SEG PANEL 481AT HAS HOLE CHAFED THRU ON INNER SKIN. REPLACED PANEL 481AT IAW IPC 57-41-41-18.SDR IPXA2020070357291Panel · damagedINSPECTION TYPE:SEG PANEL 413BL HAS (2) ELONGATED HOLES IN ATTACH FLANGE. RECEIVED NEW PNL ASSY INSTALLED ON ACCESS M10 IAW SRM 51-40-21.SDR IPXA2020070357294Longeron · damagedINSPECTION TYPE:SEG NR 1 PYLON FAIRING 475AL HAS ELONGATED HOLES IN I/B MIDDLE LONGERON ATTACH FLANGE. REMOVED AND INSTALLED NEW LONGERON IAW SRM 51-40-21.SDR IPXA2020062435895Tab · brokenINSPECTION TYPE:SEG, LEFT WING MIDDLE FLAP OTBD FACE HAS A BROKEN TAB. REMOVED AND REPLACED THE TAB IAW SRM 51-40-21.SDR IPXA2020061986725Sidewall Panel · brokenINSPECTION TYPE:SEG, FWD MDC SIDEWALL PANEL 232BK BROKEN. FABRICATED FWD MDC SIDEWALL PANEL IAW SREO A300-2550-40641-A.SDR IPXA2019101877997Handle · stiffINSPECTION TYPE:N/ASLIDE ARM / DISARM LEVER DOES NOT MOVE FREELYOPS CHECK SLIDE ARM /DISARM LEVER UNABLE TO DUPLIDATE THE PROBLEM . ITS OK FOR SERVICE REF MM 52 10SDR IPXA2019091246657Switch · faultyINSPECTION TYPE:N/A EMERGENCY LIGHT FUNCTION OF CAPT'S & F/O'S DOME LIGHTS INOP. FROM OVERHEAD PNL & PURSERS PNL. BY CREW ENTRY DOOR.REPLACED EMERGENCY LIGHTING SWITCHING RELAY 43 LE, NO HELP. REPLACED DOME LIGHT SWITCH 14LE - REF ASM 33-12-00. OPS CHECK GOOD SDR IPXA2019080745424Window · crackedDIVERSION - R1 WINDOW CRACKED AT FL 320. R&R R1 WINDOW PER MM 56-11-11-0401, OPS CK GOODSDR IPXA2019072644922Handle · missingINSPECTION TYPE:N/A INTERIOR DOOR ASSIST HANDLE ON MAIN ENTRY DOOR UPPER HANDLE MISSING REF IPC 52-11-11-03C ITEM 270. INSTALLED ENTRY DOOR HANDLE COVER W. IAW 52-11-11. THIS CLEARS M678099.SDR IPXA2019062643764Switch · intermittentINTERMITTENT CREW ENTRY DOOR OPEN WARNING OTHER INDICATIONS SHOWED DOOR PROPERLY CLOSED. REPLACED CREW DOOR WARNING SWITCH 7WS W/R/T AMM 52-71-00-0401 OPS CK GOOD.SDR IPXA2019062103549Lever · inoperativeMAIN ENTRY DOOR SLIDE ARMING LEVER WILL NOT MOVE TO ARMED POSITION. REMOVED AND REPLACED MAIN CABIN L1 DOOR SLIDE IAW MM 52-10-30-0401.SDR IPXA2019061743369Girt Bar · out of adjustMAIN DOOR EMERGENCY SLIDE WILL NOT ARM. READJUSTED GIRT BAR IAW A300 AMM 52-10-11-0501SDR IPXA2019060762918Support · gougedINSPECTION TYPE:12Y#2 ENGINE T/R, OUTBOARD CASCADE SUPPORT FRAME HAS A GOUGE/KNICK IN THE FRAME ON THE EDGE, UPPER SECTION.REPAIRED IAW UPS EO A300-7830-72740-A, DATED 06JUN19.SDR IPXA2019052942590Splice · crackedINSPECTION TYPE:124C #2 PYLON PRECOOLER PANEL, FWD SUPPORT PLATE CRACKED. REMOVED AND REPLACED SPLICE/FISHPLATE IAW SRM 51-40-21 AND DWG A54612371.SDR IPXA2019052742532Door Frame · crackedINSPECTION TYPE:124C FWD CARGO COMAPRTMENT DOOR FRAME FORK AT FR23A HOLE 7, HAS CRACK INDICATION AT THE 6 O'CLOCK POSITION WITH A DEPTH OF 0.119 - 0.122 FROM OUTER SURFACE. REPAIRED IAW REO-G22024 REV IR DATED 22-MAY-19.SDR IPXA2019052742531Door Frame · crackedINSPECTION TYPE:124C FWD CARGO COMPARTMENT DOOR FRAME FORK AT FR23A HOLE 9, HAS A CRACK INDICATION AT THE 6 O'CLOCK POSITION WITH A DEPTH OF 0.120 - 0.122 FROM OUTER SURFACE. REPAIRED IAW REO-G22024 REV.IR DATED 22-MAY-19.SDR IPXA2019052742526Door Frame · crackedINSPECTION TYPE:124C FWD CARGO COMPARTMENT DOOR FRAME FORK AT FR24 HOLE 9, HAS A CRACK AT THE 6 O'CLOCK POSITION WITH A DEPTH OF 0.120 FROM OUTER SURFACE. REPAIRED IAW REO-G22024 RE.IR 22-MAY-19.SDR IPXA2019052742525Door Frame · crackedINSPECTION TYPE:124C FWD CARGO COMPARTMENT DOOR FRAME FORK AT FR24 HOLE 2, HAS A CRACK INDICATION AT THE 6 O'CLOCK POSITION WITH A DEPTH OF 0.120 FROM OUTER SURFACE. REPAIRED IAW REO-G22024 REV.IR DATED 22-MAY-19.SDR IPXA2019052742524Door Frame · crackedINSPECTION TYPE:124C FWD CARGO COMPARTMENT DOOR FRAME FORK AT FR21 HOLE 7, HAS A CRACK INDICATION AT THE 12 O'CLOCK POSITION WITH A DEPTH OF 0.120 - 0.122 FROM OUTER SURFACE. REPAIRED IAW REO-G22024 REV.IR DATE 22-MAY-19.SDR IPXA2019061243158Hinge · damagedINSPECTION TYPE:12Y, RMLG DOOR CENTER DOOR HINGE LUG ID FOR BEARING EXCEEDS TOLERANCE.INSTALLED SLEEVE PER UPS EO A300-5280-72802-A.SDR IPXA2019061083011Retainer · damagedINSPECTION TYPE:12YRAPU R/H AFT DOOR CUTOUT AT C101 SEAL RETAINER AND SEAL DAMAGED.REMOVED AND REPLACED DAMAGED SEAL AND SEAL RETAINERS PER A300-600 SRM 51-40-44 AND 51-40-21.SDR IPXA2019060742948Hinge Fitting · damagedINSPECTION TYPE: 124CL, MLG DOOR CENTER DOOR HINGE LUG ID FOR BEARING EXCEEDS TOLERANCEINSTALLED SLEEVE PER EO A300-5280-72802-ASDR IPXA2019052642493Floor Panel · crackedINSPECTION TYPE:12YR FWD CARGO PIT FLOOR PANEL 131DE CRACKED FR25-FR27. REPAIRED PANEL 131DE IAW EO#A300-5320-42721-F APPENDIX - A.SDR IPXA2019061243160Floor Panel · crackedINSPECTION TYPE:12Y, MAIN CABIN FLOOR PANEL 231TG HAS A CRACKED INSERT.REPAIRED PER UPS DWG B53270744 REV A.SDR IPXA2019061243157Fitting · crackedINSPECTION TYPE:12Y, CRACK INDICATION IN 3 EA. LOCATIONS, L/H FR 40 UPPER JUNCTION, UPPER HOLE.REPAIRED PER HAECO REO G22035 REV IR AND UPS EO A300-5710-72842-A.
Back to N126UP