N1321A
Service difficulty reports · 377
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1321A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1321A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018103102432Warning Message · false activationLEFT STRUT DUCT LEAK EICAS, PERFORMED QRH. PERFORMED FIM 26-18 FT 804 AND AMM 26-18-00, NO DEFECTS NOTED. PRESSURE CHECKED THE LT PACK AREA AND L/E DUCT LEFT SIDE PRSOV. NO LEAKS NOTED. PERFORMED A DUCT LEAK AND WHEEL WELL FIRE CARD IAW AMM 26-10-00 CHESDR UIEA2018100302172Warning System · false activationON CLIMB OUT "LT ENG BLEED OFF" EICAS. PERFORMED BITE TEST OF AIR SUPPLY MONITOR UNIT PASSED NO FAULTS OR EICAS MSG AT THIS TIME AMM 36-11-0.SDR UIEA2018100102138Clamp · looseEICAS: " L STRUT DUCT LEAK" FL 390, QRH ACCOMPLISHED L DUCT PRESS 5 PSI RT DUCT PRESS 31 PSI. FOUND LOOSE V-BAND CLAMP IN PYLON JUST FWD OF PRSOV RE-TORQUED V-BAND CLAMP AND RAN ENGINE, NO DUCT LEAK NOTED AT THIS TIME. REF AMM 70-50-00 AND 71-00-00.SDR UIEA2018102902401Bearing · migratedRT A/C PACK AFT EXHAUST DOOR RT ATTACH BEARING HAS MIGRATED LINER. REMOVED AND REPLACED RT A/C PACK AFT EXHAUST DOOR RT ATTACH BEARING IAW S20-50-03.SDR UIEA2018102902402Link Assy · wornNR 1 ENG TCC DUCT AFT OF FUEL NOZZLES HAS 2 EA ATTACH LINKS WITH WORN RODEND BEARINGS. REMOVED AND REPLACED 2 EA ATTACH LINKS AFT OF FUEL NOZZLES ON NR 1 ENG I/B SIDE IAW AMM 70-50-00. (SUP DD 10/27)SDR UIEA2018102902403Unknown · leakingNR 1 ENG, OIL TANK LEAKING AT FILL AND DRAIN PLUGS. CLEANED NR 1 ENG OIL TANK, AREA AROUND FILL AND DRAIL PLUGS IAW SOPM 20-30-03 PERFORMED. SATISFACTORY CHECK OF NR 1 ENG OIL TANK AND (NO LEAKS NOTED) IAW AMM 71-00-00. (SUP DD 10/27)SDR UIEA2018102902404Sensor · faultyRT PRIM HX IN INDICATION IS MISSING ON EICAS. REMOVED AND REPLACED RT TEMP BULB SENSOR, PERFORMED INSTALLATION TEST IN RT TEMP BULB SENSOR WITH NO FAULTS IAW AMM 21-52-08 RT PRIM HX IN EICAS. (SUP DD 10/27)SDR UIEA2018102902405Acoustic Panel · damagedLOOSE FIBERGLASS MESH ON ACOUSTICAL PANEL NR 2 ENGINE FAN CASE AT 5 OCLOCK POSITION IAW SRM 54-12-01 REPAIR 6. REPAIRED MESH ON ACOUSTICAL PANEL NR 2 ENGINE FAN CASE AT 5 OCLOCK POSITION IAW SRM 54-12-01 REPAIR 6. (SUP DD 10/27)SDR UIEA2018102902406Lug · brokenEQUIPMENT COOLING FAN MOUNTING LUG BROKEN OFF FROM ASSY. REMOVED AND REPLACED EQUIPMENT COOLING FAN IAW AMM 21-58-06. OPS CHECK GOOD, NO LEAK NOTED. (SUP DD 10/27)SDR UIEA2018102902407Cooling Fan · faultyEQUIPMENT COOLING EXH FAN C/B IS POPING OUT. REMOVED AND REPLACED EQUIPMENT COOLING FWD EXH FAN IAW AMM 21-58-06. PERFORMED INSTALLATION TEST IAW AMM 21-58-06. (SUP DD 10/27)SDR UIEA2018102902408Pin · migratedLT A/C PACK RAM AIR INLET DOOR FWD HINGE HAS MIGRATED PIN. RESEATED LG A/C PACK TAM AIR INLET DOOR FWD HINGE IAW AMM 21-53-01. (SUP DD 10/27)SDR UIEA2018102902409Hinge · wornLT A/C PACK RAM AIR INLET DOOR WORN 2ND FROM FWD HINGE RT SIDE. REMOVED AND REPLACED LT A/C PACK RAM AIR AFT HINGE ON DOOR IAW SRM 51-40-02. (SUP DD 10/27)SDR UIEA2018102902410Seal · damagedMISSING MATERIAL OF THE BUTYL SEAL OF THE FLAPPER DOOR AFT ASSEMBLY. REMOVED AND REPLACED SEAL ON FLAPPER DOOR AFT ASSY (OUTFLOW VALVE TOP DOOR SEAL) IAW AMM 51-31-01. (SUP DD 10/27)SDR UIEA2018102902411Housing · damagedLT AC PACK RAM AIR EXHAUST DOOR HOUSING HAS 8 SQ IN DISBONDED. LAYER LOOKING FWD THRU OPEN DOOR .REPAIRED LT A/C PACK RAM AIR EXHAUST DOOR HOUSING IAW AMM 21-23-07. PERFORMED LEAK AND OPERATION CHECK IAW AMM 21-53-02. LEAK AND OPERATIONAL GOOD. (SUP DD 10/27)SDR UIEA2018102902413Hinge · looseNR 2 ENG RT CORE COWL BLOW OUT DOOR FITS LOOSE WHEN FULLY CLOSED. REMOVED AND REPLACED UPPER AND LWR HINGES ON BLOW OUT DOOR IN NR 2 ENG RT CORE COWL IAW SRM 51-40-02. (SUP DD 10/27)SDR UIEA2018102902414Clamp · looseDURING E&E COOLING LOW FLOW MONITOR SYSTEM TEST E5 FLOW BALL INTERMITTENT. T/S FOUND LOOSE HOSE CLAMP ON E&E COOLING LOW FLOW MONITOR. RE-SECURED HOSE CLAMP AND PERFORMED SATISFACTORY OPS CHECK IAW AMM 21-58-34.SDR UIEA2018090901929Warning System · false activationEICAS MSG L STRUT DUCT LEAK. PERFORMED WING AND BODY DUCT LEAK DETECTION BITE PROCEDURE IAW FIM 26-18 FAULT TREE 804 AND FOUND NO DEFECTS AT THIS TIME.SDR UIEA2018090401878Hf Comm · malfunctionedDURING COAST OUT HF RADIO L/R BOTH UNREADABLE NO COMM ESTABLISHED, NO SELCAL, RADIO COULD HEAR US BUT WE COULD NOT HEAR THEM. TRANSFER TO MDDR 98961 IAW MEL 23-11-01-02A CAT D DUE 01 JAN 18 PLACARDS INSTALLED.SDR UIEA2018090301872Warning System · false activationON LANDING LEFT STRUT DUCT LEAK EICAS MESSAGE. PERFORMED FIM 26-18 FT 804, NO FAULTS NOTED AT THIS TIME. DUCT LEAK OPS CK OK.SDR UIEA2018090501901A/C Pack · out of adjust"LT PACK OFF" EICAS MESSAGE IN FLIGHT. PERFORMED ADJUSTMENT OF LT PACK SYSTEM. OPS CHECKS GOOD AT THIS TIME IAW AMM 21-51-00.SDR UIEA2018090501900Sensor · failed"LT ENG BLEED OFF" EICAS MESSAGE IN FLIGHT. REMOVED AND REPLACED LEFT FAN AIR TEMP SENSOR IAW AMM 36-11-17. LEAK AND BITE TEST OK.SDR UIEA2018082201768Plenum · contaminatedAT CRUISE, APPROX 5 MIN AFTER APU START A STRONG ODOR WAS DETECTED. AFTER APU SHUTDOWN THE ODOR DISSIPATED. IT CAME BACK DURING DESCENT AT APPROX 60,000, WITH L PACK OFF THE ODOR WAS LESS NOTICEABLE. PERFORMED FIM 21-00-21 LEFT PACK. FOUND NO TRACES OF OIL IN SDR UIEA2018071201445Oil System · leakingAPU INOP. WHILE SEARCHING FOR SOURCE OF SMELL PERFORMED GVI OF LEFT PACK AS PER AMM 21-51-00 FOUND EVIDENCE OF OIL AT DUCT FWD OF AC BEFORE TRIM AIR VALVE, LT PACK CLEAN OIL ON AN DIN DUCTS AS PER AMM 21-00-21, CLEANED RESIDUAL OIL IN MIXING MANIFOLD AS PER AMSDR UIEA2018071101429Apu · inoperativeAPU INOP. THIS ITEM DEFERRED UNDER 49-11-01A, CAT "C". DUE DATE: 20JUL18.SDR UIEA2018071001415Unknown · odorSTRANGE OFFENSIVE ODOR EMANATING FROM THE AIRCRAFT VENTILATING SYSTEM WHEN THE PACKS ARE RUNNING. PERFORMED INSPECTION FOR SMOKE AND FUMES FROM AIRCRAFT VENTILATION SYSTEM IAW AMM 05-51-56, NO OFFENSIVE ODOR OR SMOKE DETECTED AT THIS TIME.SDR UIEA2018062101213Shutoff Valve · faultyAFTER ENGINE START LEFT BLEED OFF EICAS MSG WITH BLEED SW ON LT ENGINE DUCT PRESSURE ZERO (REPEATED ITEM). DUE HISTORY - PERFORMED TROUBLE SHOOTING AS FOLLOWS: R&R BLEED AIR CONTROL CARD PN 285T1115-15 SN OFF D01731 SN ON D01066 -AMM36-11-12. R&R HPSOV PN 8021SDR UIEA2018061801181Unknown · odorPACKS HAVE EXTREMELY BAD ODOR EMANATING FROM THEM. LEFT FLIGHT WITH HEADACHE. BAD SOCK? RAN PACKS IAW 21-00-00-862-024 AMM FOR ONE HOUR NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018061901196Controller · malfunctionedL ENG BLEED STATUS MSG. R&R PRV CONTROLLER IAW 36-11-19. TEST OK.SDR UIEA2018061301144Valve · malfunctionedL ENGINE BLEED EICAS AFTER START. REMOVED AND REPLACED NR 1 ENGINE FAN AIR VALVE IAW AMM 36-11-16. PERFORMED OPS AND BITE TEST OPS NORMAL.SDR UIEA2018060901087Warning System · false activationLAND R WX RADAR INOP. "WX FAIL" APPEARS ON BOTH CA & FO EHDI. "WX SYS" STATUS MESSAGE. PERFORMED OPS CHECKS ON THE L+R WX RADAR PER AMM 34-43-00, OPS CHECKS GOOD & RAN FIM 34-45 TASK 805 BOTH SYSTEM OK.SDR UIEA201805250949Unknown · odorODOR EMANATED FROM THE A/C PACKS. PERFORMED AN OPS CHECK IAW AMM 21-63-01, SYSTEM TESTED OK. COULD NOT DUPLICATE THE ODOR.SDR UIEA2018052200930Unknown · odorBAD ODOR EMANATING FROM THE A/C PACKS. PERFORMED AN OPS CHECK IAW AMM 21-63-01. RAN BOTH PACKS HOT FOR FIVE MINUTES THEN RAN BOTH PACKS COLD FOR FIVE MINUTES, COULD NOT DUPLICATE THE ODOR.SDR UIEA2018050300841Acm · malfunctionedLEFT PACK TEMP ON CLIMBOUT. AFTER STBY N AND 5 MINS, PACK RESET PUSH INOP LIGHT STAYS EXTINGUISHED. REMOVED AND REPLACED LT PACK ACM IAW MM21-51-03.SDR UIEA2018050100817A/C Pack · warning messageAFTER TAKE OFF, AN EICAS MESSAGE FOR THE LT PACK TEMP ILLUMINATED. OPERATED THE LEFT PACK IN STBY N MODE IAW QRH 2.33 PROCEDURES.SDR UIEA2018050100815Warning Message · false activationLEFT PACK TEMP MESSAGE. ACCOMPLISHED A PACK TEMP BITE, NO FAULTS NOTED IAW FIM 21-51 FT 844 , OPERATED PACK FOR OVER AN HOUR, OPS CHECKED GOOD IAW AMM 21-51-00,SDR UIEA2018042500794Transmitter · leakingFOUND A LEAKING PRESSURE TRANSMITTER ON THE NR 2 ENGINE. DEACTIVATED THE PRESSURE TRANSMITTER IAW AMM 73-33-01. REMOVED AND REPLACED, AND REACTIVATED THE NR 2 ENGINE FUEL PUMP PRESSURE TRANSMITTER IAW AMM 73-33-01-402-033-H00. OPS & LEAK CHECKED GOOD.SDR UIEA2018032200452Controller · failedAFTER DE-ICING, THE LT ENGINE BLEED OFF EICAS MESSAGE AND LT ENGINE BLEED SWITCH OFF LIGHT ILLUMINATED AND WILL NOT EXTINGUISH. RAN THE ENGINE IAW AMM 71-00-00, CYCLED LEFT BLEED SWITCH AND CIRCUIT BREAKER. LEFT ENGINE BLEED OK. REMOVED AND REPLACED THE NR 1SDR UIEA2018031900431Warning Message · activatedR ENG FUEL VAL EICAS MESSAGE ON ENGINE START. DEFERRED PER MEL 73-21-03-01 CAT C PLACARD INSTALLED MDDR 91252.SDR UIEA2018031900438Relay · failedEICAS MESSAGE FOR THE STANBY BUSS OFF ILLUMINATED. REMOVED AND REPLACED THE K104 RELAY IAW AMM 24-33-02 AND STANDBY POWER PANEL IAW AMM 24-33-04. OPS CHECKED NORMAL IAW AMM 24-33-00.SDR UIEA2018031900437Valve · faultedLEFT ENGINE FAN AIR VALVE SWITCH DISAGREE. FOUND THE LEFT ENGINE FAN AIR VALVE FAULTING. REMOVED AND REPLACED FAN AIR VALVE IAW AMM 36-11-16, OP CHECKED OK.SDR UIEA2018031900436Valve · failedAPU INOPERATIVE. ACCOMPLISHED AN APU BITE IAW FIM 49-11/ 958, FOUND REVERSE FLOW FAULT. ACCOMPLISHED 49-11 FAULT TREE 965. REMOVED AND REPLACED APU SURGE VALVE IAW AMM 49-53-01, OPS CHECKED NORMAL.SDR UIEA2018031900435Sensor · malfunctionedRT FATS DOES NOT COMMAND FAN AIR VALVE. REMOVED AND REPLACED THE RT ENGINE FAN AIR VALVE TEMP SENSOR IAW AMM 36-11-17.SDR UIEA2018031900434Rod · missingNR 1 ENGINE COOLING AIR DUCT TURBINE SECTION LT SIDE ONE LINK ROD MISSING. INSTALLED A NEW ROD IAW AMM 75-24-03.SDR UIEA2018031900433Valve · not reportedOVER PRESSURE RELIEF VALVE NEEDS TO BE RESET ON THE LT FUSELAGE. ACCOMPLISHED RESET IAW AMM 21-32-00.SDR UIEA2018031400404Cabin Pressure · malfunctionedAT FL 370 CABIN ALTITUDE BEGAN A SLOW CLIMB, WITH OUTFLOW VALVE FULLY CLOSED. DESCENDING TO FL 300 AND CABIN ALT STABILIZED AT 9000FT. PERFORMED A BITE CHECK OR THE PRESSURE CONTROLLERS IAW AMM 21-31-00. OPS CHECKED GOOD.SDR UIEA2018030500322Control Valve · failedAPU FAILED AND FAILED TO RESTART. ACCOMPLISHED AN APU BITE IAW FIM 49-11 FT 958. FOUND REVERSE FLOW FAULT, ACCOMPLISHED FIM 49-11 FAULT TREE 965, REMOVED AND REPLACED THE APU SURGE CONTROL VALVE IAW AMM 49-53-01. OPS CHECKED GOOD.SDR UIEA2018030500327Warning Message · false activationSTATUS MESSAGE AFT EQ EXHAUST FAN 2. OPS CHECKED GOOD IAW AMM 21-58-11.SDR UIEA2018030200311Adc · failedDURING APPROACH, IDLE DISAGREE. REMOVED AND REPLACED THE LEFT ADC IAW AMM 34-12-01. OPS CHECKED GOOD, PERFORMED TEST 30 OF MCDP IAW AMM 22-02-00. OPS CHECKED GOOD.SDR UIEA2018022500276Pressure Switch · malfunctionedAPU AUTO SHUTDOWN. REMOVED AND REPLACED THE GENERATOR OIL FILTER DIFFERENTIAL PRESSURE SWITCH IAW AMM 49-27-15.SDR UIEA2018021900258Fuel Filter · cloggedLEFT ENGINE FUEL FILTER BY-PASS EICAS AND STATUS MESSAGE. REMOVED AND REPLACED THE NR 1 FUEL FILTER IAW AMM 73-11-02