N139SY

Service difficulty reports · 32

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N139SY' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWIA2026031175630Flap Track · out of limitsRIGHT, INBD AFT FLAP TRACK NR 6 HAS THICKNESS REDUCTION OF .028". THIS IS OUT OF LIMITS OF SRM 57-53-03/AD01. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED RT, INBD AFT FLAP TRACK NR 6. IAW AMM 27-51-08. OPS CHECKED.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026031175629Flap Track · out of limitsRIGHT, INBD AFT FLAP TRACK NR 5 HAS THICKNESS REDUCTION OF .029". THIS IS OUT OF ALLOWABLE LIMITS OF SRM 57-53-03/AD01. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED RT, INBD AFT FLAP TRACK NR 5. IN REFERENCE TO AMM 27-51-08. OPS CHECKED.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026031175628Flap Track · out of limitsRIGHT, INBD FLAP TRACK 1A HAS THICKNESS REDUCTION OF .028. THIS IS OUT OF ALLOWABLE LIMITS OF SRM 57-52-03/AD01. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED RT, INBD FLAP TRACK 1A. REF: AMM 57-54-25.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026031175627Flap Track · out of limitsLEFT, INBD FLAP TRACK 1A HAS THICKNESS REDUCTION OF .042. THIS IS OUT OF ALLOWABLE LIMITS OF SRM 57-52-03/AD01. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED LT, INBD FLAP TRACK 1A IAW AMM 57-54-25HG2-695, 1-7-27.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026031175626Flap Track · out of limitsLEFT WING INBD AFT FLAP TRACK NR 6 HAS THICKNESS REDUCTION OF .030. THIS IS OUT OF ALLOWABLE LIMITS OF SRM 57-53-03/AD01 TABLE 101. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED LT WING INBD AFT FLAP TRACK NR 6 IAW AMM 27-51-08.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026040275625Flap Track · out of limitsLEFT WING INBD AFT FLAP TRACK NR 5 HAS THICKNESS REDUCTION OF .040". THIS IS OUT OF ALLOWABLE LIMITS OF SRM 57-53-03/AD01 TABLE 101. ASSET TC2-7153 DUE 9-17-26. REMOVED AND REPLACED LT WING INBD AFT FLAP TRACK NR 5 IAW AMM 27-51-08. OPS CHECKED.Mar 11, 2026 · N139SY · Emb ERJ170200LR · Trailing Edge FlapsSDR SWIA2026030975624Skin · damagedEVALUATE PREVIOUS DOUBLER REPAIR AT FRAME 11, STRINGERS 18L AND 19L FOR SERVICABILITY. PERFORMED SKIN REPAIR ON SKIN AT FR 11 STR 18L AND STR 19L. REF ETD2026-170-004397 REV B.Mar 9, 2026 · N139SY · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR SWIA2026030875623Seat Track · corrodedFORWARD WET AREA LT SEAT TRACK CORRODED AROUND THE FORWARD END OF THE MILLED SEAT TRACK AREA BETWEEN FR19-20. PERFORMED REPAIR OF FORWARD WET AREA LT TRACK BEAM BETWEEN FR19-20. REF ETD2026-170-004518 REV.A.Mar 8, 2026 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2026030875622Floorbeam · corrodedAFT WET AREA FLOORBEAM CORRODED FR86. REMOVED AND REPLACED AFT WET AREA FLOORBEAM IAW SRM 51-40-08.Mar 8, 2026 · N139SY · Emb ERJ170200LR · Fuselage Main, Floor BeamSDR SWIA2026030875621Seat Track · corrodedFORWARD WET AREA RT TRACK BEAM CORRODED AROUND SCREW HOLE AND FASTENERS AT FR 17. REPAIRED FORWARD WET AREA R/H TRACK BEAM AT FR 17, REF SRM 53-10-10/REPAIR 01P.Mar 8, 2026 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2025021006Skin · dentedEVALUATED DAMAGE AND FOUND TO BE DENT ON FR11 BETWEEN STGR 18L AND STGR 19L WITH CREASE ON BOTH SIDES OF FRAME. (FILED CLOSED) UPON INSPECTION FOUND DENT WITH A CREASE AT FR11 BETWEEN STGR 18L AND 19L TO BE OUT OF LIMITS. PERFORMED RECTANGULAR REPAIR Feb 6, 2025 · N139SY · Emb ERJ170200LR · Fuselage Main, Plate/SkinSDR SWIA2023032814Unknown · corrodedAFT CABIN FLOOR SUPPORT STRUCTURE (WET AREA) HAS CORROSION ON FR 87 AT THE RH BEAM. (C-CHECK RO 3/24/2023) PERFORMED PERMANENT REPAIR TO CORROSION ON FR 87 CROSS BEAM REF ETD2023-170-006946. REF CONTINUATION CARD FOR CORRECTIVE ACTION DETAILS. THIS ACTMar 14, 2023 · N139SY · Emb ERJ170200LR · Fuselage Internal Mounting StructureSDR SWIA202303280013Unknown · corrodedCORROSION ON AFT WET AREA R/H FLOOR BEAM AT FR87. (C-CHECK RO 3/24/2023) REMOVED AND REPLACED R/H FLOOR BEAM AT FR87. REF EMB 175 SRM 51-40-08. THIS ACTION DOES NOT EFFECT THE AIRCRAFT'S WEIGHT AND BALLANCE. REF CONTINUATION CARD FOR CORRECTIVE ACTION DMar 13, 2023 · N139SY · Emb ERJ170200LR · Fuselage Main, FrameSDR SWIA20230307Unknown · corrodedAFT CARGO LOWER SKIN HAS CORRODED SHEAR CLIP AT FRAME 85 BETWEEN STRINGERS 28R-27R. (C-CHECK RO 3/24/2023) REMOVED AND REPLACED SHEAR CLIP AT AFT CARGO LOWER SKIN FRAME 85, BETWEEN STRGS 27R-28R.SEE CONTINUATION CARD FOR WORK PEROFORMED. REF SRM 51-40-Mar 7, 2023 · N139SY · Emb ERJ170200LR · Fuselage Main, Longeron/StringerSDR SWIA2023032805Unknown · gougedRH FLOOR SEAT TRACK 23/34 HAS GOUGES AFT OF FRAMES 27, 28, 30, 31 AND 33. (C-CHECK RO 3/24/2023) PERFORMED SPLICE DEVISE CUTOUT REPAIR AT FR 27-28, 30-31, 32-33, AND 33-34. REF EMB SRM 53-00-10/ REPAIR 02P AND ETD2022-170-022163. SEE CONTINUATION FOR AMar 5, 2023 · N139SY · Emb ERJ170200LR · Fuselage Structure (General)SDR SWIA2020072951579Plate · corrodedFWD CARGO DOOR LWR HORIZONTAL BEAM CLOSING PLATE HAS CORROSION. REMOVED THE BEAM CLOSING PLATE. LOCATED AND DRILLED HOLES IN NEW CLOSING PLATE. INSTALLED NEW FWD CARGO DOOR LWR HORIZONTAL BEAM CLOSING PLATE IAW AMM, AND SRM.Jul 7, 2020 · N139SY · Emb ERJ170200LR · Cargo/Baggage DoorsSDR SWIA2020072951578Attach Fitting · corrodedFORWARD FUSELAGE FAIRING AFT LOWER ATTACHMENT FLANGE HAS MINOR CORROSION. REMOVED FORWARD FUSELAGE FAIRING ATTACHMENT FLANGE. LOCATED AND DRILLED A NEW FAIRING ATTACHMENT FLANGE. TREATED AND PRIMED, INSTALLED, RESTORED SURFACE PROTECTION IAW SRM.Jul 7, 2020 · N139SY · Emb ERJ170200LR · Fuselage Main, Attach FittingsSDR SWIA2020072951576Gusset · corrodedAFT WET AREA RT MIDDLE GUSSET IS CORRODED AT FRAME 90, RBL 12. REMOVED AND REPLACED THE GUSSET IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951575Gusset · corrodedAFT WET AREA RT GUSSET WAS CORRODED AT FRAME 90, RBL 30. REMOVED AND REPLACED THE GUSSET IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951574Floor Support · corrodedAFT WET AREA RT SUPPORT PANEL IS CORRODED BETWEEN FRAMES 88 AND 90, RBL 45. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951573Floor Support · corrodedAFT WET AREA RT INTERCOSTAL WAS CORRODED BETWEEN FRAMES 89 AND 90 RBL 12. REMOVED AND REPLACED THE INTERCOSTAL ANGLE, AND RESTORED SURFACE IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951572Splice · corrodedAFT WET AREA RT FLOOR SPLICE IS CORRODED AT FRAME 89 RBL 12. REMOVED AND REPLACED THE FLOOR SPLICE, AND RESTORED SURFACE PROTECTION, IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951571Splice · corrodedAFT WET AREA LT FLOOR SPLICE WAS CORRODED BETWEEN FRAMES 87 AND 88, LBL 40 TO 45. REMOVED AND REPLACED THE FLOOR SPLICE, RESTORED SURFACE PROTECTION, IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951570Floorbeam · corrodedAFT WET AREA FLOORBEAM IS CORRODED AT FRAME 87 LBL 12. REMOVED AND REPLACED THE FLOORBEAM IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951569Support · corrodedAFT WET AREA LT SUPPORT PANEL IS CORRODED AT FRAME 84, LBL 45. REMOVED AND REPLACED SUPPORT PANEL IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951566Seat Track · corrodedAFT WET AREA LT SEAT TRACK WAS CORRODED AT FRAME 84, LBL 12. CUTOUT DAMAGE,FABRICATED AND INSTALLED A REPAIR IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2020072951565Seat Track · corrodedAFT WET AREA RT SEAT TRACK WAS CORRODED AT FRAME 84, RBL 12. REMOVED DAMAGE, FABRICATED AND INSTALLED A REPAIR IAW SRM.Jul 6, 2020 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2020072151568Seat Track · corrodedFORWARD WET AREA RT FLOOR SUPPORT WAS CORRODED BETWEEN FRAMES 17 AND 19, RBL 35 TO 45. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM.Jul 2, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951567Seat Track · corrodedFORWARD WET AREA RT FLOOR SUPPORT WAS CORRODED BETWEEN FRAMES 12 AND 14, RBL 35 TO 45. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM.Jul 2, 2020 · N139SY · Emb ERJ170200LR · Fuselage Miscellaneous StructureSDR SWIA2020072951564Seat Track · corrodedFORWARD WET AREA LH SEAT TRACK IS CORRODED BETWEEN FRAMES 17 AND 20, LBL 12. REMOVED AND REPLACED THE SEAT TRACK IAW SRM.Jul 2, 2020 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2020072951563Seat Track · corrodedFORWARD WET AREA RT SEAT TRACK WAS CORRODED AT FRAME 17, RBL 12. REMOVED AND REPLACED THE SEAT TRACK IAW SRM, RESTORED SURFACE PROTECTION IAW SRM AND CPM.Jul 2, 2020 · N139SY · Emb ERJ170200LR · Fuselage, Seat/Cargo Attach FittingsSDR SWIA2020072951562Doubler · corrodedDURING REMOVAL OF WASTE PANEL ACCESS DOOR, FOUND CORROSION ON DOUBLER SURROUNDING WASTE PANEL CUTOUT. COMPLIED WITH TEMPORARY REPAIR PER ETD.Apr 20, 2020 · N139SY · Emb ERJ170200LR · Fuselage Main, Plate/Skin
Back to N139SY