N1439A
Service difficulty reports · 179
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1439A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1439A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2018091701990Status Message · false activationWXR SYS STATUS MSG. PERFORMED OPS CHECK OF WEATHER RADAR SYSTEM IAW AMM 34-43-00-715-026-002, NO DEFECTS NOTED AT THIS TIME.SDR UIEA2018091501978Exciter · failedAPU RELIABILITY COLD START ACCOMPLISHED ON FLT LEG TPA- SCK SAT -54C FL 410 UNSUCCESSFUL AFTER 3 START ATTEMPTS. REMOVED AND REPLACED IGNITION EXCITER IAW AMM 49-41-03. PERFORMED OPS CHECK, OPS CHECK SATISFACTORY.SDR UIEA2018091301964Unknown · malfunctionedWEATHER RADAR FAILED. PERFORMED OPERATIONAL TEST OF WEATHER RADAR SYSTEM IAW MM 34-43-00-715-001-001. WEATHER RADAR OPERATES NORMAL AT THIS TIME.SDR UIEA2018083001851Sensor · dirtyBULK CARGO TEMP READOUT ERRATIC +8 TO -56 IN FLIGHT. CLEANED AFT ZONE TEMP SENSOR (BULK PIT) IAW AMM 21-61-09. OPS CHECK GOOD AND READING STABLE.SDR UIEA2018082701810Monitor · inoperativeENGINE VIBE DISPLAY INOP. REMOVED AND INSTALLED A SERVICABLE ENGINE VIBE MONITOR UNIT IAW AMM 77-31-03. SELF TEST CHECK GOOD IAW AMM 77-31-00.SDR UIEA2018082501794Monitor · inoperativeENGINE VIBE DISPLAY INOP. REMOVED AND INSTALLED ENGINE VIBE MONITOR UNIT IAW AMM 77-31-03, SELF TEST CHECK GOOD IAW AMM 77-31-00.SDR UIEA2018082001753Actuator · malfunctionedNR 2 ENGINE SPAR VALVE LIGHT FAILED TO ILLUMINATE WHEN FUEL CONTROL WAS SELECTED TO RUN. REMOVED AND REPLACED RT ENG FUEL SHUTOFF VALVE ACTUATOR IAW AMM 28-22-11. PERFORMED OPS CHECK IAW AMM 28-22-11. GOOD, NO FAULTS AT THIS TIME.SDR UIEA2018081401692Starter · malfunctionedLT STARTER WOULD NOT CUT OUT. R&R LT ENGINE STARTER IAW AMM 80-11-01. OPS GOOD.SDR UIEA2018081301671Fire Loop · open"L ENG FIRE 1P 2" STATUS MSG. T/S IAW WDM 26-11-11. FOUND OPEN ON LOOP 2 DETECTOR T5681. ROBBED LOOP & INSTALLED IAW AMM 26-11-02. OPS CK GOOD PER AMM 26-11-02.SDR UIEA2018072901575Actuator · faultyRT ENG SPAR VALVE DID NOT CYCLE DURING START. R&R RT ENGINE FUEL SHUTOFF VALVE ACTUATOR IAW AMM 28-22-11. OPS CHECK GOOD.SDR UIEA2018072901576Actuator · faultyLEFT HAND SPAR VALVE LIGHT DID NOT COME ON FOR ENGINE START. REMOVED AND REPLACED ENGINE FUEL SHUTOFF VALVE ACTUATOR IAW AMM 28-22-11. OPS CHECK GOOD.SDR UIEA2018073001581Indication Sys · malfunctionedLOWER EICAS LEFT & RIGHT VIBE INDICATIONS BLANK. CYCLED VIBE CIRCUIT BREAKERS IAW AMM 20-60-01. PERFORMED ENGINE RUN IAW AMM 71-00-00. VIBE INDICATION OPS CHECK NORMAL. OK FOR SERVICE.SDR UIEA2018072301539Warning System · false activationDURING DESCENT AT 18000 FT GOT WXR FAIL STATUS MESSAGE ON F/O ND. PERFORMED OPS TEST OF WEATHER RADAR AS PER AMM 34-43-00, NO MESSAGES PRESENT. OPS CHECK GOOD.SDR UIEA2018072301537Warning System · false activationWHEN CAPT SELECTS WXR OFF FROM EFIS CONTROL PANEL, FO RECEIVES WXR FAIL ON EHSI WHEN FO SELECT WXR OFF ON EFIS CONTROL PANEL, CAPT RECEIVES WXR FAIL ON EHSI. CARRIED OUT WEATHER RADAR OPERATIONAL TEST AS PER AMM 34-43-00 FOUND GOOD AT THIS TIME.SDR UIEA2018072301538Status Message · false activationON SHUT DOWN WXR SYSTEM STATUS MSG. NO STATUS MSG PRESENT, PERFORMED GROUND TEST NO DEFECTS AT THIS TIME AS PER AMM 34-43-00.SDR UIEA2018072001520Relay · failedLT IDG VALVE. SERVICED BOTH IDG TO FULL IAW AMM 12-13-03. PERFORMED FIM 24-20-FT 802 REMOVED AND REPLACED RELAY IAW SWPM 20-81-11 K468. NO FAULTS NOTED AT THIS TIME.SDR UIEA2018071901518Light · inoperativeRIGHT SPAR VALVE LIGHT DID NOT CYCLE WHILE STARTING THE RIGHT ENGINE. REPLACED RT SPAR VALVE LIGHT ASSY AS PER SWPM 20-84-18, OPS CHECK GOOD AT THIS TIME.SDR UIEA2018071201450Warning System · activatedAFTER FIRST ENGINE START, RT AUX PITOT EICAS REMAINED ILLUMINATED, AFTER SECOND ENGINE START, RT AUX PITOT STILL REMAINED ILLUMIINATED. DEFERRED PER MEL 30-31-02 DMI 96358.SDR UIEA2018071001410Probe · faultyAFTER FIRST ENGINE START RIGHT AUX PITOT EICAS REMAINS ILLUMINATED AFTER SECOND ENGINE START RIGHT AUX PITOT EICAS STILL REMAINED ILLUMINATED. REMOVED AND REPLACED PROBE ASSY PITOT STATIC RT SIDE LOWER IAW AMM 34-11-01. PERFORMED HIGH RANGE LEAK CHECK REF TASKSDR UIEA2018071001414Circuit Card · defectiveRIGHT DUCT LEAK LOOP INOP. REPLACED WW O/H CARD PER AMM 26-10-01 CHKS GOOD NO FAULTS.SDR UIEA2018070901407Warning System · false activationON LANDING EICAS MESSAGE RIGHT AUX PITOT HEAT. PERFORMED OPS CHECK PER FIM 30-31 FAULT TREE 806 ALL TEST PASS OK TO CONTINUE SERVICE, 0 FAULTS.SDR UIEA2018070901408Control Valve · faultySTARTING NR 2 ENGINE IN CVG THE START VALVE DID NOT EXTINGUISH UNTIL AFTER START CUTOUT. REMOVED AND REPLACED START CONTROL VALVE. OPS CHECK GOOD REF AMM 80-11-02.SDR UIEA2018070501347Switch · contaminatedNR 2 ENGINE FUEL SPAR VALVE INOP. SUSPECT LOW SWITCH SPRING TENSION, UPON FURTHER INSPECTION FOUND THE SWITCH DIODE CONTACTS TO BE CONTAMINATED WITH DEBRIS. CLEANED IAW AMM 20-60-06. OPS CHK IAW AMM 28-22-00. CHK GOOD.SDR UIEA2018070101304Actuator · malfunctionedUPON POST FLIGHT INSPECTION FOUND APU HAS NO DUCT PRESSURE. REMOVED AND REPLACED IGV ACTUATOR IAW AMM 49-52-02. OPS CHECKED GOOD.SDR UIEA2018062501249Switch · inoperativeRIGHT FWD FUEL PUMP INOP. REMOVED AND REPLACED SWITCH 33-13-00 OPS CHECK NORMAL.SDR UIEA2018062101216Warning System · false activationSTATUS MSG "WX SYS". PERFORMED FIM 34-43 FAULT TREE 805. NO FAULTS FOUND. OPS CHECK GOOD.SDR UIEA2018062001206Panel · defectiveCAPT WXR INOP. CORRECTION ACTION EFIS PANEL REPLACED. PERFORMED WEATHER RADAR SYSTEM TEST REF 34-43-00. OPS CHECK OK AT THIS TIME.SDR UIEA2018061901202Relay · faultyAPU INOP. PFM FIM TASK 49-11, NO DEFECTS NOTED. REMOVED AND REPLACED RELAY K442. FAULTY RELAY PER SWPM 20-22. OPS CHECK OK IN ALL MODES.SDR UIEA2018061901197Control Panel · faultyCAPT WX RADAR INTERMITTENT WX FAIL. REMOVED AND REPLACED EFIS CONTROL PANEL PER 34-22-02. OPS CHECKED NORMAL.
Back to N1439A