N167UP
Service difficulty reports · 124
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N167UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N167UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA0160611Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 232FF HAS A CRACK. FABRICATED MAIN CABIN FLOORBOARD NR 232FF IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160542Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 241LJ IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 241LJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160541Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOOR PANEL NR 251JM IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 251JM IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160540Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD PANEL NR 231NJ HAS A CRACK. FABRICATED MAIN CABIN FLOORBOARD NR 231NJ IAW EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160539Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231SG IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 231SG IAW EO A300-5320-16407-D,
APPENDIX B.SDR IPXA10160538Floorboard · crackedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 231RG IS CRACKED. FABRICATED MAIN CABIN FLOORBOARD NR 231RG IAW UPS EO A300-5320-16407-D, APPENDIX B.SDR IPXA10160537Floorboard · delaminatedINSPECTION TYPE:5YR, MAIN CABIN FLOORBOARD NR 241VK HAS DELAMINATED FABRICATED MAIN CABIN FLOORBOARD NR 241VK IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10160429Skin · gougedINSPECTION TYPE:5YR, REPAIR SURVEY SEQUENCE NR167-W3-02 REPAIR DOUBLER GOUGED IN 4 PLACES ON LT CTR FLAP UPPER SKIN BETWEEN RIBS 13-15 STGR 2.6 AND 2.7. REMOVED, FABRICATED AND INSTALLED NEW REPAIR DOUBLER IAW SRM 57-50-00 PB 201 PARA 4E, FIG 205 AND SRM 57-5SDR IPXA10160674Skin · dentedINSPECTION TYPE:5YR, SKIN DENTED. ACCOMPLISHED REPAIR IAW STA-SA EA300-5330-01-A2477 IR AND EO A300-5330-38319-A.SDR IPXA0160648Skin · gougedINSPECTION TYPE:5YR, LT OTBD FLAP IB L/E TIP IS GOUGED. CUT OUT DAMAGE, FABRICATED AND INSTALLED REPAIR IAW SRM 57-50-00 PARA. 4H FIG 208.SDR IPXA0160609Skin · gougedINSPECTION TYPE:5YR, RT WING OTBD FLAP INBD L/E GOUGED. CUT OUT DAMAGED L/E SKIN, FABRICATED AND INSTALLED REPAIR IAW SRM 57-50-00 PARA 4 H FIG 208.SDR IPXA0160608Skin · misrepairedINSPECTION TYPE:5YR, REPAIR SURVEY SEQ 167-F1-01. REPAIR DOUBLER AT FR 20A, STGR 39 RT DOES NOT CORRELATE WITH SRM. REMOVED REPAIR, FABRICATED AND INSTALLED REPLACEMENT REPAIR IAW UPS EO A300-5330-38211-A AND SAA EA 300-5330-01-A2465.SDR IPXA10160428Floor Panel · misrepairedINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 161GF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL NR 161GF IAW EO A300-5320-16407-D, APPENDIX D.SDR IPXA10160374Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 161JF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL 161JF IAW EO A300-5320-16407-D APPENDIX D.SDR IPXA10160373Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR161HF REQUIRES REPLACEMENT IAW EO A300-5320-16407-D. FABRICATED BULK CARGO COMP FLOOR PANEL NR161HF IAW EO A300 5320-16407-D APPENDIX D.SDR IPXA10160372Floor Panel · unknownINSPECTION TYPE:5YR, BULK CARGO FLOOR PANEL NR 162HF REQUIRES REPLACEMENT IAW UPS EO A300-5320-16407-D. FABRICATED BULK CARGO FLOOR PANEL NR 162HF IAW UPS EO A300-5320-16407-D, APPENDIX D.SDR IPXA10160371Floor Panel · damagedINSPECTION TYPE:5YR, MCD FLOOR PANEL NR 261AH REQUIRES REPLACEMENT IAW UPS EO A300-5320-16407-D. FABRICATED FLOOR PANEL NR 261AH IAW EO A300-5320-16407-D APPENDIX B.SDR IPXA10158375Lens · missingEMERGENCY LIGHT LENS NEAR COCKPIT DOOR MISSING. REPLACED LIGHT ASSY IAW AMM 33-51-17. OPS CHECK GOOD.SDR IPXA10158259Computer · faultedEMERGENCY DECLARED - WHILE IN CRUISE, NAV MODE FAILED SEVERAL TIMES REVERTING TO HDG MODE. T/S IN REF TO TSM 2-10-00 AND AMM 22-40-00-05, FOUND FCU FAULTED, REMOVED AND REPLACED FCU IN REF TO AMM 22-15-12-04 AND TESTED IN REF TO 22-00-00 P BLOCK 501 AND 22-40-SDR IPXA09158028Slide · unwanted deployMAIN ENTRY DOOR SLIDE DEPLOYED ON GROUND. DEFERRED IAW MEL 52-11-01-3. VERIFIED ENTRY DOOR CLOSED AND LOCKED.SDR IPXA09156366Warning Light · inoperativeINSPECTION TYPE:N/A EVAC SLIDE WARNING LIGHT INOP. REMOVED AND REPLACED POWER SUPPLY UNIT WRT AMM 52-73-18-04 AND 52-73-00-05. OPERATIONAL CHECK WAS GOOD.SDR UPS08151458Skin · chafedINSPECTION TYPE:1C LT CENTERFLAP IB UPPER SURFACE HAS HEAVY CHAFFING. REMOVED DAMAGE, FABRICATED, AND INSTALLED REPAIR DOUBLER IAW A300-600 SRM 57-50-00.SDR UPS07149604Escape Rope · misinstalledINSPECTION TYPE:N/A F/O'S ESCAPE ROPE IS NOT INSTALLED PROPERLY. PART OF ROPE IS TRAPPED IN PANEL, WON'T RELEASE FULLY, NEEDS TO FREELY BE RELEASED AND PROPERLY REPACKED. REMOVED ROPE AND REPACKED PROPERLY.SDR UPS07149545Light · inoperativeINSPECTION TYPE:PS DURING TEST OF GLARESHIELD EMERGENCY LIGHTS FOUND LAMP 133LE INOP. RELAMPED AND CHECKS GOOD PER PS CK METHODS STEP 10 AND MM 33-12-00-09.