N171UA

Service difficulty reports · 293

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N171UA' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2012092405425Reveal · crackedWINDOW 7J INNER PANE SEAL WEAK. FOUND WINDOW ASSY INNER BOTTOM CRACKED. ASSY CANNOT KEEP IN POSITION. INTERIM REPAIR WITH TAPE. MAKE CF ITEM. REMOVED AND REPLACED 7J WINDOW REVEAL AS REQUIRED. SHADE OPS CHECKS GOOD.Sep 24, 2012 · N171UA · Boeing 747422 · Passenger Compartment EquipmentSDR UALA2012092405424Battery · faulty1L EEL STRIP FLICKERS ON THE WALL. REPLACED BATTERY, SYSTEM CHECKS GOOD.Sep 24, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012082704804Light · brokenEMERGENCY LIGHT SEAT 42H BROKEN IN HALF. REPLACED EMERGENCY LIGHT SEAT 42H, OPERATIONAL CHECK OKAY.Aug 26, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012082704803Circuit Breaker · faultyCAPT'S WINDSHIELD AIR FAILED. CREW COMMENTS: AT FL330. FOUND BOTH CAPT & F/O WINDSHIELD DEFOG VALVES FAILED CLOSED. MANUALLY OPENED BOTH VALVES PER MEL REQUIREMENTS, AIRFLOW NOTED ON BOTH CAPTS & F/O'S WINDOWS. REPLACED CIRCUIT BREAKER C10291 ON THE P180 PAug 26, 2012 · N171UA · Boeing 747422 · Windshield/Door Rain/Ice RemovalSDR UALA2012080804282Cover · unsecureCOCKPIT ESCAPE HATCH NEEDS TO BE RETAPED. SECURED ESCAPE HATCH COVER.Jul 31, 2012 · N171UA · Boeing 747422 · Emergency ExitsSDR UALA2012073004113Actuator · failedON PUSHBACK, APU INLET DOOR ADVISORY AND STATUS MESSAGE. FOUND APU DOOR IS PARTIALLY OPENED. INSTALLED NEW ACTUATOR.Jul 28, 2012 · N171UA · Boeing 747422 · Auxiliary Power Unit (APU) DoorsSDR UALA2012072303959Socket · faultyUPPER DECK CEILING LIGHT AT SEAT 17 IS INOPERATIVE. REPLACED LIGHT SOCKETS. CHECKS NORMAL.Jul 22, 2012 · N171UA · Boeing 747422 · Passenger Compartment LightingSDR UALA2012062203306Controller · faultyAIRCRAFT HAVING TROUBLE ACCEPTING FUEL. MANIFOLD NOT OPENING. REPLACED NR 3 REFUEL VALVE CONTROLLER.Jun 17, 2012 · N171UA · Boeing 747422 · Aircraft Fuel Distribution SystemSDR UALA2012061103222Lamp · inoperativeEMERGENCY CEILING LIGHT AT ROW 50. RELAMPED, OPS CHECKED NORMAL.Jun 9, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012061103221Lamp · inoperativeEMERGENCY LIGHT UPPER DECK CEILING AT ROW 13 INOPERATIVE. RELAMPED, OPS CHECKED NORMAL.Jun 9, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012061103220Connector · unsecureEMERGENCY LIGHT INOPERATIVE AT SEAT 51 ABC. SECURED CONNECTOR, OPS CHECKED NORMAL.Jun 9, 2012 · N171UA · Boeing 747422 · Light System WiringSDR UALA2012050102583Lamp · inoperativeR2 DOOR GALLEY AREA LOWER SIDEWALL EMERGENCY LIGHT IS INOPERATIVE. RELAMPED. CHECKED NORMAL PER MM 33-51-12.May 1, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012050102581Lamp · inoperativeUPPER DECK CEILING EMERGENCY LIGHTS 2EA IS INOPERTIVE. RELAMPED CEILING LIGHTS IN UPPER DECK CEILING. CHECKED NORMAL.May 1, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012050102580Lamp · inoperativeSEAT 53 HJK EMERGENCY LIGHT IS INOPERATIVE. RELAMPED, OPS CHECKED NORMALMay 1, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012042002393Lamp · inoperativeSEAT BELT AND NO SMOKE SIGN INOPERATIVE. REPLACED LAMPS, OPS CHECKED OKAY.Apr 19, 2012 · N171UA · Boeing 747422 · Passenger Compartment LightingSDR UALA2012032201819Drain Valve · leakingFOUND LEFT HST SUMP DRAIN SOLENOID LEAKING EXTERNALLY. RE-ACTIVATED HST ISO VALVES DV439 AND DV440 AS REQUIRED. ON ARRIVAL CHECK FOUND FUEL SEEPAGE FROM RT HORIZONTAL STABILIZER DRAIN HOLE NEAR STA 285. MUST EMPTY TANK AND CONFIRM NO LEAKS BEFORE DEPT. HST Mar 21, 2012 · N171UA · Boeing 747422 · Fuel StorageSDR UALA2012031201586Fireshield · wornNR 4 ENG OUTBOARD CORE COWL TRAILING EDGE IS WORN. NR 4 ENGINE, RT CORE COWL FIRESHIELD WORN. REPLACED CORE COWL.Mar 10, 2012 · N171UA · Boeing 747422 · Engine Cowling SystemSDR UALA2012031201583Light · inoperativeDOOR 2 GALLEY AISLE EMERGENCY LIGHT FWD WALL INOPERATIVE. RELAMPED, CHECKS NORMAL.Mar 10, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012031201582Light · inoperativeUPPER DECK DOOR RT EMERGENCY LIGHT INOP. RELAMPED, CHECKS NORMAL.Mar 10, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012031201584Light · inoperativeDOOR 4 LT FWD EMERGENCY SILL LIGHT INOP. RELAMPED, CHECKS NORMAL.Mar 10, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012020800765Line · leakingWATER LEAKING FROM THE BELLY OF FUSELAGE UNDER THE AFT CARGO PIT. COMPLIED WITH MEL 3810W, ONLY TO REVERSE MEL PROCEDURE AFTER LINE REPLACED. NEW LINE INSTALLED AND LEAK CHECK GOOD.Feb 7, 2012 · N171UA · Boeing 747422 · Water and Waste SystemSDR UALA2012012000429Battery Pack · dischargedSEAT ROW 54HJK TO 60 HJK EMERGENCY LIGHTS IS INOP. REPLACE BATTERY PACK FOR EMERGENCY LIGHTS SEAT ROWS 54-60 HJK. CHECKS NORMAL.Jan 20, 2012 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2012011200257Circuit Card · failed"HUMID FLT DK" EICAS ADVISORY MESSAGE DISPLAYED. FLIGHT DECK HUMIDIFICATION SYSTEM FAILURE. REPLACED ECS CARD. YMLA13 CARD. OPS CHECKED COVERED ON DF444. REPLACED & REINSTALLED FLIGHT DECK HUMIDIFIER, OPS TESTED GOOD.Jan 11, 2012 · N171UA · Boeing 747422 · Humidity Control SystemSDR UALA2011121906981Ballast · faultyG1 GALLEY LIGHT REPORTED FLASHING. AREA INSPECTED. NO ODOR OR EVIDENCE OF ARCING. INSPECTED BEHIND CIRCUIT BREAKER PANEL. NO ODOR OR EVIDENCE OF ARCING. RELAMPED LIGHT ASSY. NO HELP. CIRCUIT BREAKER PULLED AND COLLARED. ALL OTHER COMPONENTS OPS NORMAL. . REPLADec 19, 2011 · N171UA · Boeing 747422 · Passenger Compartment LightingSDR UALA2011122107002Trim Panel · misinstalledRUDDER AND AILERON TRIM PANEL IS INSTALLED THE WRONG WAY AND USE OF TRIM IS OPPOSITE OF WHA FOUND AIL, RUD TRM CTL PANEL MOUNTED UP SIDE DOWN AND TRIM INDICATOR IN WRONG POSITION AS STATED. REMOVED AIL, RUD TRIM CTL PANEL TO CORRECT CONFIGURATION AND RELOCATEDec 18, 2011 · N171UA · Boeing 747422 · Rudder Tab Control SystemSDR UALA2011121406832Frame · crackedBS 2120 FRAME UPPER STRUCTURE CRACKED BETWEEN RBL 40 & RBL 45.3. MAJOR REPAIR ACCOMPLISHED, MANUFACTURED & INSTALLED NEW FRAME SECTION REF ECRA 5300-01382, EN 747EN-53-038 5.Dec 12, 2011 · N171UA · Boeing 747422 · Fuselage Main, FrameSDR UALA2011121206793Intercostal · crackedLEFT OVERWING INTERCOSTAL WEB CRACKED BS 1220. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB SECTION PER SB 747-53A2750.Dec 12, 2011 · N171UA · Boeing 747422 · Fuselage Miscellaneous StructureSDR UALA2011121206792Intercostal · crackedRIGHT OVERWING INTERCOSTAL WEB CRACKED BS 1220. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB SECTION PER SB 747-53A2750.Dec 12, 2011 · N171UA · Boeing 747422 · Fuselage Miscellaneous StructureSDR UALA2011121206791Intercostal · crackedRIGHT OVERWING INTERCOSTAL WEB CRACKED BS 1200. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB SECTION REF SB 747-53A2750.Dec 12, 2011 · N171UA · Boeing 747422 · Fuselage Miscellaneous StructureSDR UALA2011112106395Stringer · corrodedFOUND BULGES IN FUSELAGE SKIN AT AND BETWEEN RIVETS IN STR 51R AND 51L APPROX BODY STA 1940-1950. PERFORMED VISUAL INTERNAL INSPECTION, CORROSION APPEARS TO BE LOCALIZED TO AREA BETWEEN STRINGERS AND SKIN AT TWO LOCATIONS STR 51L&R STA 1945 LUMP APPEARANCE LANov 21, 2011 · N171UA · Boeing 747422 · Fuselage Main, Plate/SkinSDR UALA2011111606275Light · inoperativeTWO EMERGENCY AISLE CROSSOVER LIGHTS INOP AT BOTTOM OF STAIRWAY. RELAMPED, OPS CHECK OKAY.Nov 16, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011110906123Light · missingSEAT MOUNTED EMERGENCY LIGHT MISSING. REPLACED MISSING EMERGENCY LIGHT.Nov 9, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011102105690Oxygen Mask · no testCAPTAIN'S OXYGEN MASK WILL NOT TEST. REPLACED OXYGEN MASK PER 35-11-18-0401, 35-11-00 PG 506.Oct 19, 2011 · N171UA · Boeing 747422 · Crew Oxygen SystemSDR UALA2011101305569Lamp · inoperativeAFT FLOOR EMERGENCY LIGHT INOPERATIVE. RELAMPED, OPS CHECKED NORMAL.Oct 13, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011101305568Lamp · inoperativeEMERGENCY LIGHT AT SEAT 56 ABC INOPERATIVE. RELAMPED, OP CHECKED NORMAL.Oct 13, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011101305567Lamp · inoperativeEMERGENCY LIGHT AT SEAT 25 ABC INOPERATIVE. RELAMPED, OP CHECKED NORMAL.Oct 13, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011091905029Cowling · damagedUNDERSIDE OF NR 4 ENGINE NACELLE IS DAMAGED. REPLACED INLET COWL NR 4 ENGINE REF MM & CHECKS REF JRH 2-86-1, ALL SATISFACTORY, NO FURTHER DEFECTS.Sep 17, 2011 · N171UA · Boeing 747422 · Engine Cowling SystemSDR UALA2011091604993Nose Cowl · damagedNOSE COWL DAMAGED BY GROUND EQUIP. UNDERSIDE OF NUMBER 4ENGINE NACELLE IS DAMAGED. CARRIED OUT INSPECTION. WILL REQ RPL OF NOSE COWL. PCN 185-9199 COWL AND SLING 056-0097 ON ORDER. RPLC'D INLET COWL NR 4 ENGINE AND CHECKS ALL SATISFACTORY, NO FURTHER DEFECTSSep 16, 2011 · N171UA · Boeing 747422 · Engine Cowling SystemSDR UALA2011082604570Light · inoperativeDOOR 3R FWD SILL EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604569Battery Pack · dischargedUPPER DECK EMERGENCY LIGHT ABOVE STAIRWAY IS INOP. REPLACED EEL BAT PACK, OPS CHECK NORMAL.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604568Light · inoperativeSEAT 53HJK EMERGENCY LIGHT IS INOP. RELAMPED, OP CHECK NORMAL.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604567Light · looseSEAT 25 HJK EMERGENCY LIGHT IS INOP. RESECURED EMERGENCY LIGHT, OP CHECK NORMAL.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604566Light · inoperativeLEFT OVERWING SECOND LIGHT ASSY FWD LAMP IS INOP. RELAMPED, OP CHECK NORMAL.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604565Battery Pack · dischargedUPPER DECK RIGHT WING DOOR 2 EA EMERGENCY LIGHTS IS INOP. REPLACED RT UPPER DECK EMERGENCY BATTERY PACK, ALL LAMPS CHECK OKAY.Aug 26, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011082604576Skin · corrodedRT UPPER WING SURFACE HAS CORROSION JUST FWD OF DOOR 3R APPROX 2FT OUT FROM WING ROOT. BLENDED AREA, PERFORMED ULTRA SOUND INSP FOUND .310" MATERIAL REMAINING AT DEEPEST BLENDED AREA. ACP-HFEC SURFACE EDDY CURRENT CHECK FOR CRACKS AT WING SURFACE INDICATED BAug 26, 2011 · N171UA · Boeing 747422 · Wing, Plate/SkinSDR UALA2011071703615Housing · leakingFUEL LEAKING FROM RT HST INBD PCU HOUSING DRAIN HOLE. BOROSCOPED RT INBD HST PCU ACT HOUSING. FOUND SEVERAL LEAKS AT INBD SIDE FASTENERS MID SECTION.BLOWN BACK TO CLEAN AND VERIFIED SOURCE OF LEAK. DEFUELED HST AND SUMPED. BLOW BACK SUSPECTED AREA, NO LEAKJul 16, 2011 · N171UA · Boeing 747422 · Fuel Controlling SystemSDR UALA2011070503329Valve · malfunctionedON TAXI OUT AT SFO FUEL WAS COMING OUT THE RT SIDE VENT. WILL NEED TO CHECK FUEL FILL VALVES PER MM. IF GOOD WILL NEED TO CHECK FUEL VENT VALVES. ALL TANK FUEL VALVES OPERATE NORMAL AND ARE CLOSING. FILLED WING TANKS TO FULL TAXIED AIRCRAFT 15 MINUTES NO FJul 5, 2011 · N171UA · Boeing 747422 · Fuel StorageSDR UALA2011070503333Light · unsecureLOWER EXIT PATH LIGHTING AT 2R IS HANGING OFF. SECURED LIGHT, OP'S CHECKED GOOD.Jul 4, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011070103247Light · brokenLAV 102 LOWER CORNER EMERGENCY LIGHT BROKEN. SECURED EMERGENCY LIGHT.Jun 30, 2011 · N171UA · Boeing 747422 · Emergency LightingSDR UALA2011052502558Lamp · inoperativeTWO EA EMERGENCY LIGHTS NEAR FLOOR BETWEEN DOOR TWO LEFT AND TWO RIGHT LIGHTS INOPERATIVE. RELAMPED, OPS CHECKED GOOD.May 25, 2011 · N171UA · Boeing 747422 · Emergency Lighting
Back to N171UA