N182UA
Service difficulty reports · 454
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N182UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N182UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2007UALA01848Battery Pack · faultyD-ZONE RIGHT SIDE EEL LIGHTS BLINK ON AND OFF. [06-22-07] REPLACED BATTERY PACK OPS CHECKS NORMAL.SDR 2007UALA01610Light · looseEEL LIGHT STAIRWAY RIGHT SIDE UD LOOSE. [SUP 06-06-07] SECURED EEL. LIGHTS CK OK .SDR 2007UALA01567Light · inoperativeEMERGENCY LIGHT NEAR DOOR 5 RIGHT ALONG MIDDLE BOTTOM LAV WALL INOP. REPLACED EMERGENCY LIGHT.SDR 2007UALA01566Light · inoperativeEMERGENCY LIGHT ROW 38 LEFT INOP. RELAMPED EMERGENCY LIGHT. OP CHECKS NORMAL.SDR 2007UALA01565Connector · unsecureEMERGENCY LIGHT ROW 40 RIGHT INOP. [SUP 06-06-07] RESECURED CONNECTOR. OP CK NORMAL.SDR 2007UALA01564Light · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 34 RIGHT INOP. RELAMPED EMERGENCY LIGHT, OK CHECKS NORMAL.SDR 2007UALA01512Lavatory · inoperativeFLIGHT DIVERTED DUE TO ALL LAVATORIES GOING INOP. HISSING SOUND NOTED BELOW 1R. TRIED TROUBLESHOOTING TO NO AVAIL. [SUP 06-06-07] EXISTING SERVICE BULLETIN 747-38-2109 DIRECTS TO REPLACE RELAY R8432 (LEVEL SENSING TRANSFER RELAY). THIS RELAY IS IDENTIFIED SDR 2007UALA01411Motor · overheatedCART LIFT MOTOR NR 2 OVERHEATED AFTER CATERING SERVICE LOADED 8 FOOD CARTS. [SUP 06-01-07] REPLACED CART LIFT ACTUATOR MOTOR ASSY PER MM25-38-02. OP CHECKED GOOD.SDR 2007UALA01133Oven · odorOVEN 032 AUX B-C GALLEY SMOKES AND HAS BURNED PLASTIC ODOR. [SUP 05-04-07] REPLACED OVEN, OPS NORMALLY. BURN ODOR IS GONE. A/C OK FOR SERVICE.SUSPECT FOOD SERVICE WRAP FELL ON HEATING ELEMENTS.SDR 2007UALA01110Wire · looseEEL INOPERATIVE ROW 53L. REPINNED LOOSE WIRE IN SEAT PLUG. OPS CHECKED GOOD.SDR 2007UALA01083Lamp · inoperativeEEL INOPERATIVE AT SEAT 3J AFT SECTION, ROW 39R & SEAT 32R. *S/D* RELAMPED EMERGENCY LIGHT.SDR 2007UALA01082Battery · inoperativeEEL INOPERATIVE SEAT 5A AFT SECTION. *S/D* REPLACED BATTERY.SDR 2007UALA01081Battery · inoperativeEMERGENCY LIGHT INOPERATIVE AT DOORS 2R & 5L SLIDE ILLUM.SDR 2007UALA01080Lamp · inoperativeEMERGENCY LIGHTS INOPERATIVE AT FWD GALLEY CEILING, COCKPIT CEILING, LEFT SIDE FWD GALLEY CEILING & ROW 15 CEILING. *S/D* REPLACED LAMP.SDR 2007UALA01095Warning Light · activatedPRE-DEPARTURE CREW REPORTED APU BATTERY CHARGER STATUS MSG 24099A. [SUP 05-08-07] REPLACED APU BATTERY & OP CHECKS OK. MSG STATUS NORMAL, A/C RETURNED TO SERVICE.SDR 2007UALA00848Guard · out of adjustEMERGENCY EXIT LIGHTS ON RIGHT SIDE OF ACFT CAME ON INFLIGHT. LEFT SIDE STAYED OFF. UNABLE TO DUPLICATE ON GRD. TESTED LIGHTS VIA FLT DECK SWITCH AND OPS NML ON BOTH SIDES. CHECKED VIA SWITCH AT 1L ATTENDANT SEAT AND OPS NORMAL. NOTE: SWITCH GUARD NOT POSITSDR 2007UALA00197Light · inoperativeEMERGENCY EXIT LIGHT INOP AT DOOR 4 LEFT AFT SILL, UPPER DECK EXIT DOOR AFT CEILING, UPPER DECK CEILING AT ROW 17 & SEAT 5F AFT. REPLACED LAMPS IN ALL FOUR POSITIONS. EACH OP CHECKS NORMAL.SDR 2007UALA00196Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP AT SEAT 46L & AT AFT CREW REST STAIR LIGHT. REPLACED LIGHT ASSY BOTH POSITIONS. BOTH OP CHECK NORMALLY.SDR 2006UALA02152Light · inoperativeFOUND EEL LIGHT INOP AT 5J AND 4J. REPLACED EEL LIGHT. OPS CHECKED.SDR 2006UALA02151Skin · crackedNR 4 PYLON SIDE SKIN CRACKED AT ACCESS PANEL 482ER CUT-OUT. INSTALLED REPAIR DOUBLER REF SRM 54-50-01 RPR 2.SDR 2006UALA02146Light · inoperativeLT OVERWING EMERGENCY LIGHT INOP, 3RD FROM FWD. RELAMPED. OPS CHECKED OK.SDR 2006UALA01815Lamp · burned outFOUND EEL 2A AFT INOP. RELAMPED. OP CHECKS OK FOR SERVICE.SDR 2006UALA01813Lamp · burned outFOUND EMERG LT OVERWING 2ND ASSY FROM AFT, BOTH BULBS INOP. RELAMPED. OP CHECKS OK FOR SERVICE.SDR 2006UALA01812Feeder Cable · damagedFOUND EEL AT LT SIDEWALL LAV 111 INOP. REPLACED FEEDER & EEL LIGHT, CHKS OKSDR 2006UALA01040Light · inoperative#3 LEFT EXTERIOR EMERGENCY LIGHT BOTH LAMPS INOP.SDR 2006UALA01041Light · missingEEL LIGHT ASSY MISSING FROM SEAT 47C.SDR 2006UALA00133Light · inoperativeCEILING EMERGENCY LIGHT INOP AT 2R ENTRY, ABOVE ROW 16 AND COCKPIT CEILING.SDR 2006UALA00132Light · inoperativeEEL AT 38ABC INOP.SDR 2006UALA00131Light · inoperativeSTAIRWAY EEL LIGHTS INOP.SDR 2005UALA01262Lamp · inoperativeEMERGENCY LIGHT INOP DR2 LT ENTRY CEILING. *S/D* REPLACED LAMP EMERGENCY LIGHT.SDR 2005UALA01271Connector · inoperativeEMERGENCY LIGHTS INOPERATIVE AT DOOR 3L: SILL, ENTRY CEILING, EXIT SIGN AND SLIDE ILLUMINATED (BUSTLE). RESET CONNECTOR.SDR 2005UALA01080Lamp · inoperativeMID LAV FLOOR TO WALL CROSS AISLE EMERGENCY LIGHT IS INOP. REPLACED EEL LAMP.SDR 2005UALA01079Light · inoperativeSEAT EMERGENCY LIGHT 58 HJK IS INOP. REPLACED EEL LIGHT.SDR 2005UALA01078Lamp · inoperativeEMERGENCY CEILING LIGHT NEAR SEAT ROW 44 ABC IS INOP. REPLACED LAMPSDR 2005UALA00993Duct · burnedWALL/FLOOR ON LEFT SIDE OF ACFT BY ROW 24 WAS EXTREMELY HOT WITH A BURNING SMELL. DUCT ASSEMBLY SIDEWALL RISER P/N 214U2119-11 FOR ZONE C WAS FOUND WITH HEAT DAMAGE AT THE HOT TRIM AIR INLET INTERFACE (STA 1153.66). THE DUCT ASSY EXHIBITED A DARK BROWN COLORSDR 2005UALA00905Power Supply · dischargedEMERGENCY LIGHTS UPPER DECK LEFT SIDE ROWS 16-17 SELF-ILLUM. SELF-TURNED OFF NOW. REPLACED POWER SUPPLY.SDR 2005UALA00839Light · intermittentEMER LT INTERMITTENT ON/OFF STAIR-LOC 658.SDR 2005UALA00728Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE, DOOR 1 SLIDE ILLUMINATED. REPLACED LAMP.SDR 2005UALA00727Fuse · burned outEMERG LTS INOP, LT OVERWING 2 EA AFT MOST ASSY'S. REPLACED FUSE IN PWR SUPPLY.SDR 2005UALA00726Lamp · inoperativeEMERG LT INOP, MAIN STAIRS ILLUM. REPLACED EEL LAMP.SDR 2005UALA00725Lamp · inoperativeEEL INOP, ROW 38 LT. REPLACED EEL LAMP.SDR 2005UALA00724Lamp · burned outEMERGENCY LIGHTS INOP AT ROW 14, ROW 17 CEILING, AND DR 3L CEILING. REPLACED LAMP.SDR 2005UALA00632Battery · dischargedAT RANDOM TIMES AFTER TAKEOFF & IN CRUISE THE EMERGENCY LIGHTS COME ON, U-D & STAIRS. REPLACED LOW BATTERY.SDR 2005UALA00404Bottle · lowLOW BOTTLE PRESSURE.SDR 2004UALA00836Valve · inoperativeNR 2 CROSS FEED VALVE CLOSED AND UNABLE TO USE FUEL IN NR 2 RSV TANK. VALVE BODY COULD NOT BE DRIVEN OPEN BY THE ELECTRICAL ACTUATOR. VALVE BODIES ARE FLOWN TO FAILURE. THERE HAVE BEEN TWO OF THESE VALVE BODIES REPLACED IN THE LAST 12 MONTHS WITH AN MTBUR OSDR 2004UALA00512Skin · damagedFUSELAGE DAMAGE AT STA 670-700 STR 46L-44R & STA 710-740 STR 42R-45R. MAJOR REPAIRS ACCOMPLISHED. INSTALLED JOINT REPAIRS, STRINGER REPAIRS AND THREE DOUBLER REPAIRS.SDR 2004UALA00004Battery · inoperativeEMERGENCY EXIT LIGHTS FLOOR LIGHT DAMAGED AT ZONE-E AREA OF SEATS 57C - 58C. REPLACED EEL BATTERY IN FRONT OF 5L.SDR 2002UALA00817Wire · chafedCREW REPORTS RIGHT BLEED DUCT LEAK, FOLLOWED FLIGHT MANUAL ISLN PROCEDURE AND INDIC REMAINED INTERMITTENT. NR 4 DUCT PRESS WAS 14 PSI WITH VALVE DESELECTED. AFTER CREW REPORTED A (POSSIBLE) RIGHT BLEED DUCT LEAK ON CLIMB WITH MESSAGE EVERY MINUTE AT FL250 SDR 2001UALA02157Wire · exposedFLIGHT ATTENDANT REPORTED BRIEF FIRE IN AFT GALLEY FROM CART N54 PIGTAIL HAS EXPOSED WIRE. THE 9F21904-501 PIGTAIL CABLE IN THE G5 GALLEY WAS DAMAGE DUE TO THE CABLE BEING PINCHED BETWEEN THE NEW TECH CART AND GALLEY COUNTER TOP. THE CABLE WAS REPLACED WITH SDR 2001UALA01696Compressor · surgesNR 3 ENGINE STALLED ON TAKE OFF, FLAMES REPORTED OUT TAILPIPE, EGT OVER TEMPTED OVER 820 DEGREES FOR 15 SECONDS, PEAK EGT 848 DEGREES. CREW WRITE-UP, ENGINE FIRE WARNING NR 3 ENGINE ON TAKE OFF. ENGINE FIRE-DAMAGE CHECKLIST ACCOMPLISHED. TOWER OBSERVED SLIGHT