N186US
Service difficulty reports · 291
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N186US' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N186US' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA2013090900018Floor Support · corroded2S CHECK, CORROSION ON FLOOR SUPPORT FRAMES 64 - 67, -Y465. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-00-14, 51-42-11, 51-44-11 & 51-75-12.SDR USAA2013090900017Floor Support · corroded2S CHECK, CORROSION ON FLOOR SUPPORT FRAMES 65 TO 67, -Y318. REPLACED FLOOR SUPPORT IAW SRM 51-74-00, 53-00-14, 51-42-11 & 51-21-11.SDR USAA2012122700001Bottle · low pressureCIDS PANEL CAUTION LIGHT ILLUMINATED DURING BOARDING PROCESS. MAINTENANCE FOUND 2R DOOR BOTTLE PRESSURE LOW - SERVICED 2R DOOR IAW AIRBUS MAINTENANCE MANUAL 52-22-00-614-002-A.SDR USAA2012120500011Lens · brokenPLASTIC EXIT LIGHT COVER AT 4L DOOR BROKEN. INSTALLED SERVICEABLE EMERGENCY EXIT LIGHT COVER AT 4L DOOR.SDR USAA2012070500016Lens · brokenEMERGENCY LIGHT LENS BROKEN ON 9D. INSTALLED NEW LENS.SDR USAA2012062600003Lens · missingROW 10 A/C LEFT FLOOR PATH RED EXIT LIGHT MISSING. INSTALLED NEW RED EXIT LIGHT LENS AT ROW 10.SDR USAA2012062500024Bottle · low pressureCIDS CAUTION LIGHT ON FOR MID LEFT AND RIGHT DOOR ASSIST. SERVICED 2R DOOR ASSIST BOTTLE IAW AIRBUS MAINTENANCE MANUAL 52-73-00.SDR USAA2012062500021Bottle · low pressureCIDS PANEL CAUTION LIGHT ON FOR MID LEFT AND RIGHT DOOR ASSIST. SERVICED L2 AND R2 DOOR ASSIST BOTTLES IAW AIRBUS MAINTENANCE MANUAL 52-73-00.SDR USAA2012031900030Audio Panel · faultyNR 1 RADIO FAILED DURING DESCENT INTO LAS. THERE WAS A HOT WIRE ODOR ASSOCATED WITH FAILURE. REMOVED AND REPLACED NR 1 AUDIO CONTROL PANEL IAW AIRBUS MAINTENANCE MANUAL 23-51-12.SDR USAA2011100300019Lens · missingLI DOOR SLIDE ARMED LIGHT COVER MISSING. MAINTENANCE REPLACED L1 DOOR SLIDE ARMED LIGHT COVER.SDR USAA2011072200006Lens · missingEMERGENCY LIGHT LENS MISSING AT 5L. REPLACED MISSING LENS AT 5L.SDR USAA2011052391955Light · inoperativeFLT 1471 -TPA - EEL - OVERHEAD EMERGENCY LIGHT NEAR DOOR 3R INOPERATIVE. MAINTENANCE REMOVED AND REPLACED 3R DOOR OVERHEAD EMERGENCY LIGHT ASSEMBLY IAW AIRBUS MAINTENANCE MANUAL 33-51-00.SDR USAA2011021490705Lens · missingFLT 1035 - CLT - EEL - LOW LEVEL EMERGENCY LIGHT COVER MISSING SEAT 8D. MAINTENANCE REPLACED MISSING LENS COVER AT ROW 8D.SDR USAA2010111792619Fitting · corrodedPIT - C11 - MAJOR REPAIR - CORROSION ON CLEAT AT FR27 BETWEEN S43R TO S44R. REPLACED CLEAT AT FR27 BETWEEN S43R TO S44R IAW A321 SRM 51-72-00.SDR USAA2010092092030Lens · missingINSP LAX - EEL - SEAT MOUNTED EMERGENCY EXIT LIGHT LENS MISSING AT SEAT 5C. MAINTENANCE REPLACED LENS AT SEAT 5C.SDR USAA2010042690828Lens · brokenFLT 815 - CLT - EEL - EMERGENCY EXIT LIGHT LENS COVER BROKEN ROW 23 LEFT SIDE. MAINTENANCE REPLACED EMERGENCY EXIT LIGHT COVER AT ROW 23 LEFT AS REQUIRED.SDR USAA2009081392102Lens · missingFLT 1543 - SEA - EEL - EMERGENCY LIGHT LENS IS MISSING AT THE L-1 DOOR. MAINTENANCE REPLACED LIGHT LENS AT L-1 DOOR.SDR USAA2009022690451Wire · looseFLT 1624 - ORD - EEL - ROW 24 LT FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RE-SECURED WIRE TO LAMP ASSEMBLY. OPERATIONAL CHECK GOOD.SDR USAA2009022690442Wire · looseFLT 1624-ORD - EEL - ROW 9 RT FLOOR LEVEL EMERGENCY LIGHT INOPERATIVE. MAINTENANCE RE-SECURED WIRE TO LAMP ASSEMBLY. OPERATIONAL CHECK WAS GOOD.SDR USAA920081458Battery · dischargedFLT 1627 LGA-CLT - EMERGENCY EQUIPMENT - AFT EMERGENCY FLASHLIGHT INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY. OPERATIONAL CHECK WAS GOOD. (S)SDR USAA920081015Power Supply · inoperativeFLT NR 1418 LAX-PHL - EEL - WHILE ACCOMPLISHING EPSU BATTERY TIME CHANGE, FOUND 14WL UNABLE TO TEST. MAINTENANCE REMOVED AND REPLACED 14WL EMERGENCY POWER SUPPLY UNIT.SDR USAA070725Seat Track · corrodedINBOARD SEAT TRACK Y765 FRAME 47.1 & 47.2 HAS CORROSION. REMOVED AND REPLACED SEAT TRACK PER SR 53-00-15, DEFECT SIZE: 1" X 4" X .090".SDR USAA070716Floor Support · corrodedPAX FLOOR SUPPORT AT FR 20 40 INCHES RIGHT OF BL 0. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 51-72-11; CORR TASK JA-220-53500, CORR LEVEL 1, DEFECT SIZE: 2 SQ INCHES.SDR USAA070717Floor Support · corrodedFLOOR SUPPORT - Y1292 BETWEEN FR 64-69 HAS CORROSION. REMOVED AND REPLACED PAX FLOOR SUPPORT PER SRM 51-72-11; CORR TASK JA-260-53500; CORR LEVEL 1, DEFECT SIZE: 2.5 SQ INCH.SDR USAA070718Floor Support · corrodedFLOOR SUPPORT -Y1292 BETWEEN FR 64-69 HAS CORROSION. REMOVED AND REPLACED PAX FLOOR SUPPORT PER SRM 51-72-11; CORR TASK JA-260-53500; CORR LEVEL 1, DEFECT SIZE: 1 SQ INCH.SDR USAA070719Floor Support · corrodedFLOOR SUPPORT -Y1292 BETWEEN FR 64-69 HAS CORROSION. REMOVED AND REPLACED PAX FLOOR SUPORT PER SRM 51-72-11, DEFECT SIZE: 2 INCHES.SDR USAA070720Floor Support · corrodedFLOOR SUPORT Y1292 BETWEEN FRAMES C69-C65 HAS CORROSION. REMOVED AND REPLACED FLOOR SUPPORT PER SRM 53-00-14; CORR TASK JA-160-53500; LEVEL 1, DEFECT SIZE: 1 X 2 INCHES AT 3 AREAS.SDR USAA070721Floor Support · corrodedFLOORBEAM Y1292 BETWEEN FRAMES C69-C65 HAS CORROSION. REMOVED AND REPLACED FLOORBEAM PER SR 53-00-14, DEFECT SIZE: 1 X 2 INCHES AT 2 AREAS.SDR USAA070722Shear Tie · corrodedSHEAR PLATE AT SIDE BETWEEN FRAME 69-70 S-23R HAS CORROSION. DEFECTIVE PART REPLACED WITH IDENTICAL PART PER SRM 51-72-11, DEFECT SIZE: 2 SQ INCHES.SDR USAA070723Floor Support · corrodedY254 FLOOR SUPPORT BETWEEN FRAMES 16-20 HAS CORROSION. DEFECTIVE PART REPLACED WITH IDENTICAL PART PER SRM 51-72-11, DEFECT SIZE: 1 INCH DIA AT 3 SPOTS.SDR USAA070724Seat Track · corrodedFWD WET AREA FR 12-14 BL 10L HAS CORROSION. DEFECTIVE PART REPLACED WITH IDENTICAL PART PER SR 51-72-11; CORR TASK JA-220-53500; LEVEL 1. DEFECT SIZE: 3 X 24 INCHES.SDR USA2008F00000Rivet · corrodedCORRODED RIVET TAILS WERE FOUND IN THE FUSELAGE FWD CARGO COMPARTMENT BETWEEN FR 24 TO 35.8, STRINGER 39L TO 39R. APPROXIMATELY 1492 RIVETS WERE REPLACED. A RESIDUE OF SODIUM CLORIDE ATTACKED THE RIVETS. NUMEROUS OTHER RIVETS HAD THE PAINT FLAKING OFF THE RSDR SA05123Bottle · lowPHL - PILOT REPORTED THE LEFT OVERWING EXIT SLIDE BOTTLE PRESSURE LOW. MAINTENANCE REMOVED AND REPLACED THE SLIDE BOTTLE. CHECKS OK PER TASK 25-62-49-020.SDR USAASA03142Battery · inoperativePHL - AIRCRAFT FAILED THE EMERGENCY LIGHTS TEST WITH MESSAGE EPSU BAT AFT L. MAINTENANCE REPLACED THE AFT LEFT EMERGENCY POWER SUPPLY UNIT. OPERATIONALLY CHECKS OK. (M)SDR USAASA03075Smoke Detector · faultyBWI - FLT 197 - EN ROUTE PHL-SFO, WHILE CLIMBING THROUGH FL280, RECEIVED ECAM MESSAGE 'SMOKE LAV CRG DETECT FAULT', ACCOMPANIED BY A DISTINCT SMOKE ODOR IN THE FORWARD CABIN AND COCKPIT. THE FLIGHT DIVERTED TO BWI AND LANDED WITHOUT FURTHER INCIDENT. MAINTENSDR USAASA03033Slide · defectiveDURING TROUBLESHOOTING FOR AN 'EPSU EXT LOAD FWD L' FAULT MESSAGE, FOUND THE FORWARD RIGHT EMERGENCY ESCAPE SLIDE ALSO DEFECTIVE FOR HIGH RESISTANCE OF THE SLIDE LIGHTS. MAINTENANCE REPLACED THE R1 SLIDE. OK FOR SERVICE. (M)SDR USAASA03032Slide · malfunctionedTPA - FAULT MESSAGE, 'EPSU EXT LOAD FWD L', RESULTED DURING THE EMERGENCY LIGHTS TEST. MAINTENANCE REPLACED THE FORWARD LEFT EMERGENCY ESCAPE SLIDE DUE OT SLIDE LIGHT FAILURE. ALSO, REPLACED THE FORWARD RIGHT SLIDE DUE TO HIGH SLIDE LIGHT HARNESS RESISTANCE.SDR USAASA03003Slide · malfunctionedBOS - RECEIVED 'EPSU EXT LOAD FWD L' MESSAGE DURING THE EMERGENCY LIGHT TEST. MAINTENANCE REPLACED THE L1 DOOR ESCAPE SLIDE. OPERATIONALLY CHECKED OK. (M)SDR USAASA02102Battery · dischargedPHL - THE EMERGENCY POWER SUPPLY BATTERY AT THE L1 DOOR WAS FOUND TO BE WEAK. MAINTENANCE REPLACED THE BATTERY AT THE L1 DOOR. OPERATIONALLY CHECKS OK. (M)SDR USAASA02094Slide · defectiveBDL - DURING THE EMERGENCY LIGHT TEST, 'EPSU EXIT LOAD FWD L' MESSAGE DISPLAYED. MAINTENANCE REPLACED THE FORWARD ENTRY DOOR EMERGENCY EXIT SLIDE. OPS CHECKED OK. (M)SDR USAASA02073Light · will not testTPA - DURING THE EMERGENCY LIGHT TEST, THE EPSU EXTERNAL LOAD WAS FAULTED. THE L-1 DOOR SLIDE WAS REPLACED, THE R1 DOOR SLIDE CHECKED SATISFACTORY. (M)
Back to N186US