N19141
Service difficulty reports · 138
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N19141' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N19141' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017120204293Intercostal · corrodedMAIN MID CABIN FLOOR SUPPORT INTERCOSTAL HAS CORROSION AT BS 684, RBL 50 ON UPPER SURFACE. REMOVED, FABRICATED AND INSTALLED NEW FLOOR SUPPORT INTERCOSTAL AT MID CABIN, BS 684, RBL 50 IAW DWG 143N5845 AND SRM 51-40-02.SDR CALA2017112704234Skin · crackedNR 1 SLAT COVE HAS CRACK AT I/B OD I/B SLAT TRACK FWD MOUNT FITTING 090-005 B757-57-3-0552. REMOVED DAMAGE AND REPAIRED NR1 SLAT COVE SKIN I/B OF I/B SLAT TRACK FWD MOUNT IAW SRM 57-43-01 REPAIR 4 FIG 201 PG 201-20 5.SDR CALA2017112704231Floor Support · corrodedFOUND CORROSION ON THE MAIN CABIN FLOOR SUPPORT UPPER SURFACE AT BS 367, RBL 62. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PAGE 10, AND TWO ANGLES IAW SRM 51-40-02, PAGE 10.SDR CALA2017112604222Floor Support · corrodedMAIN MID CABIN FLOOR SUPPORT INTERCOSTAL HAS CORROSION BETWEEN BS680 AND BS700, RBL 50 ON UPPER SURFACE. REMOVED AND REPLACED MAIN CABIN FLOOR SUPPORT INTERCOSTAL AT STA 680 TO 700 RBL50 IAW SRM 51-40-02 PG 1-10 AND DWG 143N 5845.SDR CALA2017112604221Support Channel · corrodedL1 DOOR LOWER SILL SUPPORT CHANNEL 2EA CORRODED. REMOVED AND REPLACED 2 EA L1 LOWER DOOR SILL SUPPORT CHANNELS IAW SRM 51-40-02 PAGE 2 DRAWING NR 141N8322.SDR CALA2017112604220Floor Support · corrodedCORROSION ON MAIN CABIN FLOOR SUPPORT AT STA 365 RBL-25 RG-14. BLENDED OUT CORROSION AREA ON MAIN CABIN FLOOR SUPPORT AT STA 36 5 RBL-25. AREA FOUND OUT OF LIMIT IAW SRM 53-10-52 ALLOWABLE DAMAGE 1 FIG 101 DETAIL V. REMOVED AND REPLACED FLOOR SUPPORT ON MAIN CSDR CALA2017112604219Floor Support · corrodedBULK CARGO FLOOR SUPPORT STR LBL 2.9 HAS CORROSION AT BS 1510. ACCOMPLISHED REPAIR ON BULK CARGO FLOOR SUPPORT STR LBL 2.9 BS 1510 IAW SRM 53-0053 REPAIR 1 TABLE 201 DETAIL XII.SDR CALA2017112504207Transition Panel · corrodedAFT CARGO RBL 19 FLOOR SIDE PANEL HAS CORROSION ON UPPER SIDE IN MULTIPLE LOCATION FROM SPLICE AT BS 1310 TO BS 1380, 209-064. BLENDED OUT CORROSION AT AFT CARGO RT SIDE, SIDE PANEL, RBL 19 IAW 757-200 SRM 53-00-53 FIG 101 DETAIL V, ALLOWABLE DAMAGE FOUND TO BSDR CALA2017112504206Skin · crackedNR 1 SLAT COVE SKIN HAS CRACK AT O/B OF I/B SLAT TRACK FWD MOUNT FITTING. REMOVED DAMAGE AND REPAIRED NR1 SLAT COVE SKIN O/B OF I/B SLAT TRACK FWD MOUNT IAW SRM 57-43-01 FIG 201 REPAIR 4 PG 201-20 5.SDR CALA2017112404201Floorbeam · corrodedCORROSION ON THE MAIN CABIN FLOORBEAM UPPER SURFACE AT BS 398 RBL 47 TO RBL 59, CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-0-51. ALLOWABLE DAMAGE 1, FIG 101, DETAIL III. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02, PAGES 4-8.SDR CALA2017112404200Floor Support · corrodedMAIN MID CABIN FLOOR SUPPORT BETWEEN BS 680 AND 740, LBL 58.22 HAS CORROSION ON UPPER SURFACE. BLENDED THE CORRODED AREA. FOUND TO BE OUT O F LIMITS IAW SRM 53-30-15, ALLOW DAMAGE 1, FIG 101, DETAI L VI. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40SDR CALA2017112104172Floorbeam · corrodedAFT CABIN FLOORBEAM AT BS 1640 HAS CORROSION ON UPPER SURFACE FROM LBL 24 TO RBL 30. REPAIRED IAW SRM 53-00-51, FIG 201, REPAIR 3, PAGES 201-206.SDR CALA2017111003971Strap · crackedFWD CARGO STABILIZATION STRAP AT BS 560, LBL 45 CRACKED. REPAIRED IAW SRM 53-00-51, REPAIR 13.SDR CALA2017100203409Spring · brokenR2 DOOR ARM, DISARM INDICATOR SPRING IS BROKEN. REMOVED AND REPLACED HINGE ASSY. THE DOOR SLIDE ARM, DISARM INDICATOR OPS CHECKED GOOD.SDR CALA2017100203372Bulb · inoperativeUNARMED LIGHT FOR THE EMERGENCY LIGHTS ON OVERHEAD PANEL BULB INOPERATIVE. REPLACED THE BULB. OPS CHECKED GOODSDR CALA2017090803065Oven · odorMID GALLEY OVEN HAD A PLASTIC BURNING ODOR. DISSIPATED AFTER REMOVING POWER. REMOVED AND REPLACED OVEN, ALL CHECKED GOOD.SDR CALA2017090102994Battery · inoperativeEMERGENCY FLASHLIGHT AT THE L2 DOOR NOT CHARGING. REPLACED THE BATTERY. OPS CHECKED GOOD.SDR CALA2017071002139Oven · overheatedOVEN 413 AFT GALLEY OVERHEATED AFTER 15 MINUTES, SETOFF SMOKE ALARM IN LAVATORY. R & R THE OVEN. OPS CHECKED GOOD.SDR CALA2017050101212Light · brokenEMERGENCY EXIT SEAT LIGHT LENS AT 22C BROKEN. REPLACED THE EMERGENCY LIGHT, OPS CHECKED NORMAL.SDR CALA2016112500962Battery · dischargedNUMBER 2 EMERGENCY FLASHLIGHT AFT GALLEY RIGHT SIDE BATTERY INOP . INSTALLED NEW BATTERY NUMBER 2 EMERGENCY FLASHLIGHT AFT GALLEY RIGHT SIDE.SDR CALA2016111800936Connector · looseEMERGENCY LIGHT AT SEAT ROWS 32 AND 34 INOPERATIVE. FOUND CONNECTORS LOOSE, SECURED AND OP CHECKED GOOD.SDR CALA2013032500173Warning Light · false activationLEFT AFT ENTRY DOOR LIGHT ILLUMINATED ON TAKEOFF AT 80 KTS. OPENED AFT LT ENTRY DOOR AND VISUALLY INSPECTED. CLOSED DOOR AND VERIFIED PROPER LOCK.SDR CALA2012072000469Governor · malfunctionedAFTER FUEL CONTROL SWITCHES WERE PLACED IN CUTOFF, BOTH ENGINE CONTINUED TO RUN FOR ABOUT 10 SECONDS. NR 1 ENG FFG CHANGED AND OPS CHECKED AND NR 2 ENG RUN.SDR CALA2011102700689Skin · dentedPER L/P 8689269 DMG JOB 157 INSPECTED PREVIOUSLY DENTED AREA AT STA 1681.8 30 INCHES BELOW L-4 DOOR FUSELAGE SKIN IS DENTED BEYOND LIMITS IN SRM 53-00-01 DETAIL 3 A=3.5 Y=.140 A/Y 25. THIS IS A DOUBLE DENT INSTALLED REPAIR DOUBLER AS PER ECRA 5331-01543. SESDR CALA2011102700688Floorbeam · corrodedCORROSION AT FASTENER HOLE ON UPPER FLANGE OF CABIN FLOORBEAM S TA 1640 APPROX RBL 55.5. REPAIRED FLOORBEAM BY INSTALLING REPAIR ANGLE AT STA 1640 REF ECRA 5360-01165.SDR CALA2011102400681Floorbeam · corrodedAFT WET AREA STA 1620 TO RBL 20 FLOORBEAM CORRODED. REPAIRED AFT WET AREA FLOORBEAM 1620 RBL 20 REF BOEING 757/200 SRM 53-00-51 FIGURE 201 REPAIR 3.SDR CALA2010111500537Oven · overheatedAFT GALLEY OVEN AT STA 413 OVERHEATS SCORCHING FOOD SMOKE FROM THE SCORCHED FOOD SET OFF "LAV SMOKE" ALARMS RESULTING IN AN EICAS MSG "LAV SMOKE". AFT GALLEY OVEN DEPOSITS IN BOTTOM OF OVEN CLEANED OUT. C/B PULLED AND COLLARED. ITEM DEFERRED PER MEL.SDR CALA2010020500027Unknown · odorRECEIVED A LAV SMOKE EICAS MESSAGE. F/A REPORTED, SMELLED SMOKE IN AFT LAV. ON FINAL ALL LAVS SMOKE DETECTORS SOUNDED. AFTER LANDING DETECTORS STOPPED WHEN LAV OPENED. FOUND EMPLOYEE NUMBER REPORTING THIS DISCREPANCY INACTIVE. INSPECTED GENERAL AREA OF AFSDR CALA2009102300647Oven · smokeOVEN 413 SMOKES WHEN IN USE. REMOVED AND REPLACED OVEN 413, GROUND OPS CHECK NORMAL AT THIS TIME. OVEN, LARGE, SG OFF 99-2533-9-0002 SN 0370, ON 99-2533-9-0002 SN 0165.SDR CALA2009100700609Light · inoperativeL2 AND R1 DOOR EXTERIOR EMERGENCY LIGHTS ARE INOPERATIVE. RELAMPED EXTERIOR LIGHTS, OPERATIONAL CHECKS GOOD.SDR CALA2009100700608Wire · missingSEAT ROW 20C EMERGENCY LIGHT INOPERATIVE. FOUND BLACK WIRE MISSING IN SEAT HARNESS. SPLICED IN NEW SEAT HARNESS IAW SWP 20-30-12 AND 20-30-13.SDR CALA2009082600511Light · inoperativeEXTERIOR L2 DOOR EMERGENCY LIGHT INOPERATIVE. RELAMPED EXTERIOR L2 DOOR EMERGENCY LIGHT. OPS CHECKS GOOD.SDR CALA2008112501101Frame · gougedTOP OF FRAME HAS DEEP GOUGE STA 1300 STR 25R (APPROX). REPAIRED FRAME STA 1300 STR 25R REF ECRA 5311-01436.SDR CALA2008111901088Floorbeam · corrodedCABIN FLOORBEAM AT STA 365 RBL 8 HAS SMALL AREA OF SURFACE CORROSION. PERFORMED PERMANENT REPAIR TO CABIN FLOORBEAM AT STA 365 RBL 8 REF ECRA 5320-01913 STEPS 1 THRU 6.SDR CALA2008111901087Floorbeam · corrodedCABIN FLOORBEAM AT STA 365 RBL 40 HAS SMALL AREA OF SURFACE CORROSION. PERFORMED PERMANENT REPAIR TO CABIN FLOORBEAM AT STA 365 RBL 40 REF ECRA 5320-01913 STEPS 1 THRU 6.SDR CALA0800238Slide · malfunctionedDOOR 2L SLIDE BLOWN (BOTTLE DISCHARGED) BUT THE SLIDE DID NOT DEPLOY, FOUND SLIDE ON JETWAY AND UNRAVELED. REMOVED AND REPLACED SLIDE PER AMM 25-66-01. REMOVED AND REPLACED ASSIST BOTTLE PER 52-11-30.SDR CALA0600205Skin · crackedINSPECTION FOUND A 6 INCH CRACK IN RT WING FIXED L/E, WS 305-310. THE CRACKED AREA WAS LOCATED DIRECTLY IN BETWEEN THE EMERGENCY EVACUATION ROPE ATTACH FITTING AND THE I/B MAIN L/E SLAT CUTOUT TO NR 7 SLAT. THE FIXED L/E WAS REMOVED, REPAIRED, AND REINSTALLESDR CALA0600197Skin · corrodedINSPECTION FOUND FUSELAGE SKIN UNDER RIGHT PHONE ANTENNA CORRODED AT STA 1460-1480, S29R-S30R. A DOUBLER AND FILLER WERE INSTALLED IAW SRM 53-00-01.
Back to N19141