N213UA
Service difficulty reports · 185
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N213UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026092219635Light · malfunctionedEMERGENCY AREA LIGHT DOES NOT TURN OFF. EMERGENCY LIGHTING WILL NOT TURN OFF IN MAIN CABIN UPON ARRIVAL EMERGENCY LIGHTS WERE OFF INSIDE THE CABIN. PERFORMED EMERGENCY LIGHTS FUNCTIONAL TEST AND OPS CHECK GOOD. IAW AMM 33-51-00.SDR CALA2026030514355Light · shortedEMERGENCY LIGHTS - OPS TEST WITH TEST SWITCHES PROCEDURE, MULTPLE LIGHTS ASSOCIATED WITH POWER SUPPLY M33094 INOPERATIVE. FOUND POWER SUPPLY M33094 FUSE F3 OPEN, REPLACED POWER SUPPLY AS A PRECAUTION IAW AMM 33-51-06-960-803, ON FOLLOW UP TEST, CONDITION SAMSDR CALA2025101309929Switch · malfunctionedSOME OF THE EMERGENCY EXIT LIGHTS ARE ON SWITCH IS IN ARM CYCLED F-D SWITCH TO ON - OFF - AND ARM. EEL LIGHTING IN CABIN RESPOND TO EACH SWITCH SELECTION, TESTS OK..SDR CALA2025072506917Lock · obstructedDOOR FLIGHT LOCK 2R EICAS STATUS #2 RIGHT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SEN SOR DISAGREEMENT. DB PSEU 2 (R2) DB PSEU 2 (L2) INSPECTED DOOR 2R FLIGHT LOCK MECHANISM AREA. REPOSITIONED DOOR LINING INSULATION FROM PROX SENSOR TARGETS. ACCOMSDR CALA2025071006419Bustle · noneREMOVED R3 DOOR BUSTLE CLARENCE TO INSTALL DOOR THREE RIGHT BUSTLE. CLEAR TO INSTALL DOOR THREE RIGHT BUSTLE. INSTALLED DOOR 3R BUSTLE REF AMM TASK 25-66-06-400-801. VERIFIED DOOR 3R SLIDE SAFETY PIN REMOVED AND STOWED. REF. GMM.09-25-05SDR CALA2025061805680Pressure Blkhd · crackedLH MLG W/W SLOPING PRESSURE WEB AT STA1245-1287 LBL25.7 FOUND 53 EA SOLID RIVETS DAMAGE AND 1EA CRACK, REF TO HAECO NON ROUTINE NO.9466841,EA 5300-02713 REV B OP004. LT MLG W/W SLOPING PRESSURE WEB AT STA 1245-STA1287 LBL25.7 53EA SOLID RIVETS DAMAGE AND 1ESDR CALA2025061705651Battery Pack · dischargedEMERGENCY LIGHT BATTERY TEST FOUND M33093 NOT OPERATION, REPLACED M33093 EMERGENCY LIGHT BATTERY AND C/O TEST FND TEST PASSED,AS PER AMM 33-51-06-960-802 REV 10 4.SDR CALA2025061705650Battery Pack · faultedEMERGENCY LIGHT BATTERY TEST FOUND M33405 BATTERY INOP, REPLACED THE L3 DOOR M33405 EMERGENCY LT BATTERY AND C/O OP TEST.FND NORMAL PER AMM 33-51-06-960-802 REV 104.SDR CALA2025061705649Battery Pack · faultedEMERGENCY LIGHT BATTERY TEST FOUND M33408 BATTERY INOP, REPLACED THE R4 DOOR M33408 EMERGENCY LT BATTERY AND C/O OP TEST FND NORMAL PER AMM 33-51-06-960-802 REV 104.SDR CALA2025061705648Battery Pack · dischargedEMERGENCY LIGHT BATTERY TEST FOUND M33096 BATTERY INOP, REPLACED THE L2 DOOR M33096 EMERGENCY LIGHT BATTERY AND C/O OP TEST. FOUND NORMAL PER AMM 33-51-06-960-802 REV 104.SDR CALA2025061705647Battery Pack · faultedEMERGENCY LIGHT BATTERY TEST FOUND M33400 BATTERY INOP,ORIGINATE D BY EMP V903172,REF TO HAECO NON ROUTINE NO.9469613.PERFORMED BY EMP V903172 - REPLACED THE L3 DOOR M33400 EMERGENCY LT BATTERY AND C/O OP TEST.FND NORMAL PER AMM 33-51-06-960-802 REV 104.SDR CALA2025052604942Warning Horn · false activationNEAR EMER EXIT 3R AN AUDIBLE ALERT/ALARM IS SOUNDING UPON ARRIVAL NO ALARMING SOUND NOTED FROM DOOR 3 AREA. OK FOR SERVICE. NO HISTORY FOUND FOR ALARMING SOUND.SDR CALA2025022002388Socket · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - R1 DOOR SLIDE LIGHT INOP REPLACED LAMP HOLDER AND INSULATOR AND RELAMPED PER AMM 33-51-04-960-801 CK OK PARTS USED: 25-3351-3-0030,QTY :1SDR CALA2025022002387Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - AISLE AREA LIGHT AT SEAT 1BA INOP RELAMPED PER AMM 33-51-03-960-801 CK OK PARTS USED: 00-0596-3-2874,QTY :1SDR CALA2025022002386Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - AISLE AREA LIGHT ABOVE 3BA INOP RELAMPED PER AMM 33-51-03-960-801 CK OK PARTS USED: 00-0596-3-2874,QTY :1SDR CALA2025022002385Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - AISLE AREA LIGHT ABOVE 4BA INOP RELAMPED PER AMM 33-51-03-960-801 CK OK PARTS USED: 00-0596-3-2874,QTY :1SDR CALA2025022002384Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - AISLE LIGHT ABOVE 20LKJ INOP RELAMPED PER AMM 33-51-03-960-801 CK OK PARTS USED: 00-0596-3-2874,QTY :1SDR CALA2025022002383Lamp · inoperativeEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - AISLE LIGHT ABOVE 36LKJ INOP RELAMPED PER AMM 33-51-03-960-801 CK OK PARTS USED: 00-0596-3-2874,QTY :1SDR CALA2024122301615Sign · detachedEMERG EXIT SIGN DETACHD AT 30G REPLACED FLOOR PROXIMITY LIGHT - LIGHT ASSEMBLY REFERENCE AMM 33-51-05-960-802. OPS CHECK GOOD.SDR CALA2022081002017Battery Pack · failedDR L4 EMER LT BATTERY M33407 CAPACITY CHECK FAIL TRANSFER REF NR HX WO.925621 AND ORIGINATED BY EMP V898181. DR L4 EMER LIGHT BATTERY M33407 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSPECTED BY V896958. IDT INSPECTSDR CALA2022081002016Charger · failedDR L4 EMER LT BATTERY CHARGER M33407 TEST FAIL. TRANSFER REF NR HX WO.925626 AND ORIGINATED BY EMP V898181. DR L4 EMER LIGHT CHARGER M33407 REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSPECTED BY V896958. IDT INSPECTESDR CALA2020103001223Charger · no testB777-33-3-7015-RT DR2 M33098 EMERGENCY POWER SUPPLY BATTERY PACK CAPACITY FUNCTIONAL TEST FAIL, REF NR LP 9130433 DR 2R M33098 EMERGENCY LIGHT POWER SUPPLY BATTERY AND CHARGER REPLACE D AND TESTED NORMAL, AS PER AMM 33-51-06 ATTACHED FORM 44-0008 ITEM 1-2 ACCOSDR CALA2020103001222Battery · no testB777-33-3-7015 - RT DR2 M33098 EMERGENCY POWER SUPPLY BATTERY PACK CAPACITY FUNCTIONAL TEST FAIL REFER TO NR LP:9130433 DR 2R M33098 EMERGENCY LIGHT POWER SUPPLY BATTERY AND CHARGER REPLACED AND TESTED NORMAL, AS PER AMM 33-51-06. ATTACHED FORM 44-0008 ITEM 1SDR CALA2019011800120Light · brokenREFER TO NRC LOG PAGE NO.:9130124, B777-33-3-6026: RT DR4 PARTITION AFT FLOOR EMER LIGHT FOUND BROKEN. RT DR NO.4 PARTITION AFT FLOOR EMER LIGHT REPLACED & TEST OKAY IAW AMM 33-51-05.SDR CALA2019011800119Charger · inoperativeREFER TO NRC LOG PAGE NO.:9130125, B777-33-3-6026: LT DR1 EXIT SIGN CAPACITY CHECK FOUND FAIL. LT DR1 EMER PWR SUPPLY M33093 CHARGER REPLACED AND OP TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06.SDR CALA2019011800118Battery Pack · dischargedREFER TO NRC LOG PAGE NO.:9130127, B777-33-3-6026: CABIN SEAT 1DEFG TO 3DEFG EMER LT CAPACITY CHECK FOUND FAIL. CABIN SEAT 1DEFG TO 3DEFG EMER LT BATTERY PACK REPLACED AND OPERATIONAL TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2019011800117Battery Pack · dischargedREFER TO NRC LOG PAGE NO.:9130126, B777-33-3-6026: CABIN SEAT 1LK TO 4LK CEILING EMER LT CAPACITY CHECK FOUND FAIL. CABIN SEAT 1LK TO 4LK CEILING EMER LT BATTERY PACK REPLACED AND OPERATIONAL TEST RESULT NORMAL IAW AMM 33-51-06.SDR CALA2019011800116Battery · dischargedREFER TO NRC LOG PAGE NO.:9130128, B777-33-3-6026: RT DR3 EMER PWR SUPPLY M33401 BATTERY FOUND FAIL. RT DR3 EMER PWR SUPPLY M33401 BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06.SDR CALA2019011800115Charger · failedREFER TO NRC LOG PAGE NO.:9130130, B777-33-3-6026: RT DR2 EMER PWR SUPPLY M33098 CHARGER FOUND FAIL. RT DR2 EMER PWR SUPPLY M33098 CHARGER REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL IAW AMM 33-51-06.HX284042.SDR CALA2019011800114Battery · dischargedREFER TO NRC LOG PAGE NO.:9130129, B777-33-3-6026: RT DR2 EMER PWR SUPPLY M33098 BATTERY FOUND FAIL. RT DR2 EMER PWR SUPPLY M33098 BATTERY REPLACED AND INSTALLATION TEST CARRIED OUT NORMAL I.A.W AMM 33-51-06.SDR CALA2018021700669Unknown · odorAN ACRID ODOR IN THE FLIGHT DECK DURING DESCENT, WITH THROTTLES PULLED BACK. LASTED 5 MINUTES. BUT WAS STRONG ENOUGH TO MAKE EYES STING. PERFORMED CONDITIONAL INSPECTION IAW 05-51-58-800-801C3. ACCOMPLISHED AN INITIAL & OPERATIONAL INSPECTION, INCLUDING AN SDR CALA2017091003114Unknown · smokeTOWER REPORTED SMOKE COMING FROM NUMBER 1 ENGINE ON DEPARTURE. EMERGENCY DECLARED. VISUALLY INSPECTED INLET AND EXHAUST, DRAIN TUBES, AND OPENED THRUST REVERSER PRESSURE RELIEF DOORS LT & RT, NO LEAKS FOUND. CHECKED OIL QUANTITY, GOOD. CHECKED ENGINE OIL CONTASDR CALA2017061701854Fitting · out of adjustL2 DOOR WILL NOT ARM. FOUND THE AFT GIRT BAR FLOOR FITTING PAWL RUBBING THE GIRT BAR TUBE WHEN ARMING. ADJUSTED FLOOR GIRT BAR FITTINGS IAW AMM 52-00-00-001. OPS CHECKED IAW AMM52-00-00-001.SDR CALA2017050501244Splice · crackedSUPPORT TASK CABIN EA 5300-01568 OP 2 RT STA 332.5 FLOORBEAM SPLICES FOUND CRACKED. CABIN STA 332.5 RT FLOORBEAM SPLICE REPLACED AS PER EA 5300-01568.SDR CALA2017050501233Charger · inoperativeEMER LT M33099 FOUND BATTERY LOW. L2 DOOR EMERGENCY LIGHT BATTERY PACK M33099 AND CHARGER REPLACED, OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2017050501232Battery · dischargedEMER LT M33404 FOUND BATTERY LOW. R3 DOOR EMERGENCY LIGHT BATTERY PACK M33404 REPLACED AND CHECKED NORMAL AS PER AMM 33-51-06.SDR CALA2017050501231Battery · dischargedEMER LT M33406 FOUND BATTERY LOW. L3 DOOR EMERGENCY LIGHT BATTERY PACK M33406 REPLACED AND CHECKED NORMAL AS PER AMM 33-51-06.SDR CALA2017050501230Battery · dischargedEMER LT M33094 FOUND BATTERY LOW. R1 DOOR EMERGENCY LIGHT BATTERY PACK M33094 REPLACED AND OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2016082695678Ballast · failedSMOKE ODOR EXPERIENCED DURING CRUISE. BALLAST FOR OVERHEAD CEILING INDIRECT LIGHTING AT ROW 24HJ EMITED A PUFF OF SMOKE AND ODOR, LIGHT ASSY WENT OUT. FOUND CEILING LIGHT BALLAST BURNED AND HEAVY ELECTRICAL BURNED ODOR. REPLACED IAW AMM 33-21-01. OPS CHECSDR CALA2016072995600Unknown · odorACRID ELECTRICAL ODOR ON FLIGHT DECK AT GATE. RAN APU 4 HOURS, BOTH PACKS TO FULL COLD AND PACKS TO FULL HOT. FWD GALLEY OVEN AND COFFEEMAKERS ON. NO ABNORMAL ODOR DETECTED.SDR CALA2016072195568Unknown · odorELECTRICAL ODOR IN AFT CABIN, DECREASED WITH IFE SWITCH OFF. ACCOMPLISHED AMM 05-51-50, NO ELECTRICAL OR ABNORMAL ODOR IN THE CABIN NOTED AT THIS TIMESDR CALA2016061595452Fan · odorF/A REPORT OF AN ELECTRICAL ODOR AT AROUND DOOR 1R AND 1L AND DOOR 2R AND 2L ON DESCENT AROUND 10,000 FT. RAN ALL FORWARD AND MID GALLEY EQUIPMENT. CHECKED ALL CBS AND LIGHTING IN AREA BETWEEN DOORS 1 AND 2 LT AND RT. FOUND WHEN RUNNING FWD UPPER RECIRCULATSDR CALA2016022495128Skin · corrodedLEFT WING LOWER SKIN, EXTERIOR SURFACE FOUND CORROSION, AT STRINGER L14, WS 580 - 599.5, STRINGER L14, WS 626 - 678, STRINGER L14, WS 758 - 810.5, STRINGER L14, WS 810.5 - 863, STRINGER L14, WS 863 - 889.5, STRINGER L14, WS 889.5 - 942, STRINGER L14, WS 942 - SDR CALA2016022495127Skin · corrodedLEFT WING LOWER SKIN EXTERIOR SURFACE FOUND CORROSION AT STRINGER L8 - L9, WS 1074, STRINGER L10, WS 862 - 916, STRINGER L10, WS 916 - 942, STRINGER L10, WS 995 - 1021, STRINGER L10, WS 1047 - 1101, STRINGER L10, WS 1101 - 1128, STRINGER L10, WS 115 5 - 1182, SDR CALA2016022495126Skin · corrodedLEFT WING LOWER SKIN EXTERIOR SURFACE, FOUND CORROSION AT WS 889.5 - 942, WS 942 - 968.5, WS 995 - 1021.5, WS 1047.5 - 1101, WS 1101 - 1155, WS 1182, WS 1292.5 - 1320 REAR SPAR AREA. LT WING LOWER SKIN EXTERIOR SURFACE CORROSION REMOVED & PROTECTED IAW SRM 51SDR CALA2016022495124Skin · corrodedRIGHT WING LOWER SKIN UNDER SURFACE, SEVERAL AREAS WERE FOUND CORRODED, AT WS 573 - 626, STRINGER L14, WS 652 - 705 STRINGER -L14, WS 705 - 758, STRINGER L-14, WS 758 - 810.5, STRINGER -L14, WS 810.5 - 863, STRINGER -L14, WS 863 - 916, STRINGER -L14, WS 916 - SDR CALA2016021295102Structure · crackedDENT AT STATION 2105, BETWEEN STRINGER 28R & 29R, HAS CRACK OUT OF SRM LIMITS. REPAIRED IAW SRM 53-00-0 1 REPAIR 6 FIG 202. REPAIR LOCATION STATION 2100 - 2111.SDR CALA2015120894871Sign · looseEXIT SIGN AT DOOR 4L IS LOOSE. REPLACED LIGHT ASSEMBLY IAW AMM 33-51-01. OPERATIONS CHECKED GOOD.SDR CALA2015090394265Overheat Loop · dirtyBLEED LOOP 1 BODY FAILURE OF BODY DUCT LEAK DETECTION LOOP OR LT DUCT LEAK OVERHEAT DETECTION SYS, DLODS, CARD. CLEANED & RESEATED LOOP 1 M26144 TO RESISTOR M26111 CONNECTOR & RESEATED P85A5 DLODS CARD, FAULT NOT ACTIVE. BLEED LOOP 1 BODY LOOP SYS OKAY FOR SSDR CALA2015072894165Circuit Card · failedSTATUS MESSAGE, OVERHEAT CIRCUIT R2 & OVERHEAT CIRCUIT R1, DISPLAY ON EICAS WITH MAINTENANCE MESSAGE 26-10032. REPLACED P84A10 FIRE DETECTOR CARD IAW FIM MAN 26-11-818 & AMM 26-11-03-400-801. STATUS MESSAGES EXTINGUISHED.
Back to N213UA