N219UA
Service difficulty reports · 173
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N219UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025061605568Engine · faultedRIGHT ENGINE EGT EXC. 706. ON CLB OUT RET W/IN LIMITS. CREW REPORTS ON CLIMB OUT EST. 1000FT - AUTO THROTTLE ENGAGED, ENG 2 EGT REDLINED. CREW PROCEEDED TO REDUCE THRUST ON ENG 2, AND EGT FOLLOWED DROPPING BELOW REDLINE. AUTO THROTTLE RETURNED THRUST AND EGT ESDR CALA2025060505282Lamp · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE - MID GALLEY CEILING EMERGENCY LIGHT INOP RELAMPED PER AMM 33-51-03-960-801 CK OKSDR CALA2025041003668Unknown · odorFA SMELLED FUMES COMING FROM FORWARD GALLEY AREA BETWEEN 1L/R ON DESCENT UNABLE TO FIND ANY SMELLS OTHER THAN A VINAL SMELL COMING FROM THE FWD STOWAGE CLOSET WHERE THE BABY BASSENETTS ARE STOWED. STARTED APU AND OPERATED PACKS ALL TESTS OK. FIM 21-00 TASK 808SDR CALA2024121601526Elec Connector · disconnectedROW 26 GFED (BOTH LEFT AND RIGHT) FLOOR PROXIMITY EMERGENCY LIGHTS INOP. SWAPPED LIGHT ASSEMBLIES AND VERIFIED LIGHTS ARE NOT THE PROBLEM. FOUND CENTER ROW 26 EMER LIGHT CONN DISCONNECTED, RECONNECTED EMER CONNECTOR AND OPS CHK GOOD. REF WDM 33-51-65-2SDR CALA2024062601892Power Cable · damagedPDA 2 FOUND ON ARRIVAL EXTERIOR GROUND POWER SERVICE DOOR WITH SECONDARY POWER CORD STRAP OUTSIDE OF DOOR AND WHEN INSPECTED INSIDE OF DOOR FOUND HOOK MISSING. DEFERRING EXTERNAL SECONDARY POWER SYSTEM PER MEL 2441D DUE TO POWER ACCESS DOOR. DEFERRED AND PLACASDR CALA2024011700123Charger · no testB777-33-3-7031 CABIN DOOR R3 EMER LT PWR SUPPLY M33401 OPERATIONAL TEST FAIL. WORK TRANSFER NON ROUTINE WO.2732904. CABIN DOOR R3 EMER LT PWR SUPPLY M33401 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024011700122Charger · no testCABIN DOOR R3 EMER LT PWR SUPPLY M33404 OPERATIONAL TEST FAIL. WORK TRANSFER NON ROUTINE WO.2732906 AND CABIN DOOR R3 EMER LT PWR SUPPLY M33404 REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PER AMM 33-51-06.SDR CALA2024011200098Battery Pack · dischargedEMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED RESULT WITH NORMAL AS PER AMM 33-51-06. WORK TRANSFER NON ROUTINE WO.2612903. EMERGENCY LIGHTS BATTERY PACK M33424 AT DR L1 REPLACED AND INSTALLATION TEST CARRIED OUT RESULT SDR CALA2024011200094Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33408) AT DR 4R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612915. EMERGENCY LIGHTS BATTERY PACK(M33408) AT DR 4R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06SDR CALA2024011200092Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612909. EMERGENCY LIGHTS BATTERY PACK M33099 AT DR 2L REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200090Battery Pack · dischargedB777-33-3-7019 EMERGENCY LIGHTS BATTERY PACK (M33097) AT DR 2R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612923. EMERGENCY LT BATTERY PACK (M33097) AT DR 2R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. ISDR CALA2024011200088Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK (M33401)AT DR 3R FOUND CAPACITY CHECK FAIL. WORK TRANSFER NON ROUTINE WO.2612917. EMERGENCY LIGHTS BATTERY PACK(M33401) AT DR 3R REPLACED AND INSTALLATION TEST CARRIED OUT RESULT WITH NORMAL AS PER AMM 33-51-06. SDR CALA2024011200096Battery Pack · dischargedB777-33-3-7019 - EMERGENCY LIGHTS BATTERY PACK AT LLAR FOUND CAPACITY CHECK FAIL.WORK TRANSFER NON ROUTINE WO.2612901 AND ORIGINATED BY EMP V920586. EMERGENCY LIGHTS BATTERY PACK M023 AT LLAR REPLACED AND INSTALLATION TEST CARRIED OUT WITH NORMAL RESULT AS PERSDR CALA2023092102840Control Unit · failedSPOILERS EICAS ADVISORY FAILURE OF ONE OR MORE SPOILER PAIRS. FLT CONTROL SYS STATUS AFTER LANDING. REF MX MSG 27-10504, 27-10505, 27-10506 & 27-10510. PERFORMED SPOILER SYSTEM TEST PER AMM TASK 27-61-00-740-801 ALL TESTS PASSED. NO SPOILER MSG. DUE TO MSG 27-SDR CALA2022120503305Rivet · missingPDA 3 FOUND 1 MISSING RIVET ON UPPER HINGE ON AFT POTATBLE WATER SERVICE ACCESS DOOR. UPPER HINGE ALSO DAMAGED. REPLACED UPPER HINGE AND FASTENERS.SDR CALA2022120503298Controller · faultedCABIN TEMP CONTROL INOP ALL ZONES AT THE GATE FOUND DIFFERENT ZONE WORKS OUT OF DIFFERENT CHANNELS. TEMPRATURE WERE GOING COLD TO HOT AND BACK TO COLD. REPLACED RIGHT CABIN TEMP CONTROLLER , GND CHK OK.SDR CALA2022050901171Battery · failedDR L2 M33099 EMER LIGHT BATTERY PACK CAPACITY CHECK FAIL TRANSFER REF. NON-ROUTINE HX NRC WO.788687 AND ORIGINATED BY EMP NO. V898181 DR L2 M33099 EMER LIGHT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSSDR CALA2022050901166Charger · failedDR L2 M33099 EMER LIGHT PWR SUPPLY BATTERY PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.674089 AND ORIGINATED BY EMP NO. V898181 DR L2 M33099 EMER LT PWR SUPPLY CHARGER AND BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISSDR CALA2022050901165Charger · failedDR L2 M33096 EMER LIGHT PWR SUPPLY BATTERY PACK CAPACITY CHECK FAIL. TRANSFER REF. NON-ROUTINE HX NRC WO.674106 AND ORIGINATED BY EMP NO. V898181 DR L2 M33096 EMER LT PWR SUPPLY CHARGER AND BATTERY REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISSDR CALA2022050601153Battery · failedLLAR EMER LIGHT BATTERY PACK CAPACITY CHECK FAIL TRANSFER REF. NON-ROUTINE HX NRC WO.674110 AND ORIGINATED BY EMP NO. V898181 LLAR EMER LIGHT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06. WORK ACCOMPLISHED BY MECHANIC V898181 INSPECTED BY V89695SDR CALA2019083001452Oven · odorFA REPORTED UNIDENTIFIED ODOR AFTER TO IN AFT GALLEY PERFORMED SMOKE ODOR IN FLT. DECK/CABIN INSPECTION IAW MM 05-52-58-800-801C3. RAN APU, PACKS, HYD, LIGHTS, FLUSHED LAV, IFE EQUIP. AND CHECKED FOR TRIPPED C/BS. TURNED ON ALL COFFEEMAKER, WARMER, AND OVENSSDR CALA2019041900619Battery Pack · dischargedLH DOOR 3 SLIDE LIGHT FOUND INOP. REPLACED L3 DOOR SLIDE LT LAMP AND CHARGED L3 DR EMERG PWR PACK M33405 AND O/P TEST CARRIED OUT NORMAL R EF AMM 33-51-04-960-801 REV.85,AMM33-51-06-960-802 REV.85.SDR CALA2019041900618Battery Pack · dischargedEMERG PWR PACK M33400 O/P FOUND CAPACITY LOW. REPLACED EMERG PWR PACK M33400 AND O/P TEST CARRIED OUT NORMAL REF AMM 33-51-06-960-802 REV.85.SDR CALA2017122804652Skin · chafedBS 2108 TO 2150, STRINGERS 2 -3R SKIN FOUND CHAFED. THE SKIN WAS REPAIRED IAW SRM 53-70-01, REPAIR 2, REV 75, AND ECRA 5330-06262, REV B.SDR CALA2017122804651Skin · chafedBS 2108 TO 2150 STRINGERS 2 -3L SKIN FOUND CHAFED. THE SKIN WAS REPAIRED IAW SRM 53-70-01, REPAIR 2, REV 75 AND ECRA 5330-06262, REV B.SDR CALA2017122504598Lens · crackedDURING CHECK OF THE EMERGENCY LIGHT FUNCTION, FOUND THAT THREE EMERGENCY LIGHTS LENS CRACKED. REPLACED THE EMERGENCY LIGHTS, TESTED AND FOUND NORMAL IAW AMM 33-51-05-960-003, REV 81.SDR CALA2017122004550Battery · dischargedDURING CHECK THE EMERGENCY LIGHTS, FIND THAT THE AISLE LIGHTS AT STA1582 & 1666, RBL51 NOT COME ON. REPLACED THE CABIN 3R DOOR AREA M33401 BATTERY & POWER SUPPLY AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 81 & AMM 33-51-06-960-803 RESDR CALA2017122004549Battery Pack · dischargedDURING CHECK THE EMERGENCY LIGHTS, FIND THAT BOTH DOOR 4R EXIT IDENT SIGNS DOES NOT COME ON. REPLACED THE CABIN 4R AREA M33408 EMERGENCY BATTERY PACK AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-803 REV 8 1.SDR CALA2017122004548Battery · failedEMER BAT PACK M33093 FAILED IN CAPACITY CHECK. REPLACED THE CABIN 1L DOOR AREA M33093 EMERGENCY BATTERY AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-802 REV 8 1.SDR CALA2017121904525Light · brokenDURING CHECK THE EMERGENCY LIGHT FIND THAT THE DOOR 1 CENTER FROM RIGHT FLOOR PROXIMITY LIGHT DAMAGED. REPLACED THE CABIN DOOR NR 1 CENTER RIGHT FLOOR PROXIMITY LIGHT AND OP TEST CARRIED OUT, FOUND NORMAL AS PER AMM 33-51-05-960-80 2 REV 81.SDR CALA2017121804512Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M33409 FAILED A CAPACITY CHECK. REPLACED THE BATTERY PACK AND OPS TESTED NORMAL IAW AMM 33-51-06-960-801 REV.81SDR CALA2017121804511Light · crackedDURING CHECK A THE OF ZONE A CENTER DIVIDER, FOUND THAT BOTH SIDES CRACKED. THE EMERGENCY LIGHTS WERE REPLACED, TESTED NORMAL IAW AMM 33-51-05-960-802 REV.81.SDR CALA2017121804510Light · crackedDURING CHECK OF THE ZONE B CENTER DIVIDER, FOUND THAT BOTH SIDE EMERGENCY LIGHTS CRACKED. THE LIGHTS WERE REPLACED, TESTED NORMAL IAW AMM 33-51-05-960-802 REV.81.SDR CALA2017121804509Light · brokenDURING CHECK OF THE EMERGENCY LIGHTS CONDITION IN THE M2 GALLEY, FIND ALL LATERAL EMERGENCY LIGHT BODIES BROKEN. THE LIGHTS WERE REPLACED. TEST PERFORMED AND FOUND NORMAL IAW AMM 33-51-05-960-802 REV.81.SDR CALA2017121804508Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M33404 FAILED A CAPACITY CHECK. REPLACED THE BATTERY PACK AND OP TESTED NORMAL IAW AMM 33-51-06-960-802 REV.8 1.SDR CALA2017121804507Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M33094 FAILED A CAPACITY TEST. REPLACED THE BATTERY PACK AND OP TESTED NORMAL IAW AMM 33-51-06-960-812 REV.8 1.SDR CALA2017121804506Battery Pack · no testEMERGENCY LIGHT BATTERY PACK M33407 FAILED A CAPACITY CHECK. REPLACED THE BATTERY PACK AND OP TESTED NORMAL IAW AMM 33-51-16-960-802, REV 81.SDR CALA2017121804505Battery · no testEMERGENCY LIGHT BATTERY PACK M33406 FAILED IN CAPACITY CHECK. REPLACED THE BATTERY AND OP TESTED NORMAL IAW AMM 33-51-06-960-802 REV.81.SDR CALA2017100203402Lens · detachedSIDEWALL EMERGENCY EXIT LIGHT AT THE R2 DOOR AFT SIDEWALL, FOUND THE LENS DETACHED. INSTALLED LIGHT LENS.SDR CALA2017072902427Oven · overheatedOVEN R31 BUSINESS CLASS IS OVERHEATING AND SMOKING. REPLACED R31 BUSINESS OVEN. REF AMM 25-32-02. OPS CHECK GOOD.SDR CALA2016060895440Unknown · smokeFLIGHT ATTEND REPORTED VISIBLE SMOKE & ODOR FROM AFT GALLEY VENT. HALON EXT DISCHARGED INTO VENT. ALL AC FEED CB'S PULLED TO REMOVE POWER FROM GALLEY. COMPLIED WITH CONDITIONAL INSPECTION AS REQUESTED. REF SEQ 5382009 & LM 4914. NO EVIDENCE OF SMOKE OR SMSDR CALA2016060795437Unknown · smokeVERY LIGHT GREY SMOKE & BURNING ODOR IN AFT GALLEY OF ACFT. HALON BOTTLE EXTINGUISHED IN AREA & SMELL SUBSIDED. ACCOMPLISHED SMOKE INSPECTION IAW 05-51-50 WITH NO DEFECTS NOTED. FORM 46.6020 FILLED OUT.SDR CALA2016020495084Smoke Detector · false activationEICAS SMOKE CREW REST LOWER. ALSO SMOKE DETECTOR ACTIVATED LOWER CREW REST, NO SMOKE, NO HEAT IN AREA. RESET AFTER 3 MINUTES BY ITSELF. IAW THE PURSER THERE WAS NO SMOKE, NO ODOR, NO ABNORMAL HEAT IN THE FLIGHT ATTENDANT CREW REST. SMOKE DET MAT OPERATIONASDR CALA2015042093580Skin · dentedLEFT NR 4 DOOR CUT OUT AFT 50 STATION 2108 - 2129, STRINGER 24L - 26L & TWO EACH DENT. NR 4 DOOR CUT OUT REPAIR IAW ECRA 5330-05141. GENERATE CF TO NOTIFY UAL ENG PRIOR TO REACHING 29,000 PTC SA. A REQUEST FOR A NEW APPROVAL WHICH CONTAINS THE INSPECTION RESDR CALA2015042093579Skin · dentedLOWER FUSE SKIN BS 2108 - 2129 LT, STRINGER 45 - 46 FOUND THREE EACH DENTS. REPAIRED IAW ECRA 5330-05139. REMAINING DENT WITHIN SRM 53-00-01 AD1 FIG 102 TABLE A REF CF9075. NOTIFY UAL EG PRIOR TO 29000 PTC SA A REQUIRED FOR A NEW APPROVAL WHICH CONTAINS THESDR CALA2014010790056Warning System · activatedAFTER ENG START HAD BLEED OFF ENG RT EICAS & BLEED HPSOV RT STATUS.SDR CALA2013123094017Unknown · malfunctionedEQ4040 PRIMARY FLT CONTROL TEST FAILED, MESSAGE 27-10308. FLAPERON POWER CONTROL UNIT LT INBD ACTUATION CONFIDENCE TEST FAILED SEVERAL TIMES. RESET K26 CB & POWER SUPPLY CB ON 5E RACK, NO HELP. SWAPPED THE ACE WITH ANOTHER, NO HELP. SWAPPED THE ACE TO ORIGSDR CALA2013121893770Fuel Nozzle · defectiveDUE TO ENG IGNITER R2 SLOW LIGHT OFF, REPLACE SIX EACH FUEL INJECTOR NOZZLES ON RT SIDE OF ENG 7 - 12. REPLACED NR 2 ENG FUEL NOZZLES 10 - 12, NOZZLES 7 - 9. REPLACED IAW SEQUENCE # 9546008.SDR CALA2013121793759Display · malfunctionedNO FUEL INFORMATION ON FMC'S & CDU'S, RESET AIMS, INFORMATION RETURNS BRIEFLY THEN BLANKS. TRIED A FQIC, NO HELP. REINSTALLED THE ORIGINAL CONT OF AMIS ITEM 9546004.SDR CALA2013110692687Clamp · looseVIBRATION IN FLOOR BETWEEN ROWS 20-26 ON RT SIDE, ACCOMPANIED BY CHEMICAL ODOR. FLIGHT CREW SHUT DOWN RT PACK, NO VIBRATION & SMELL DISSIPATED. UNDER RT PACK FAN BYPASS CHECK VLV FLEXIBLE DUCT CLAMP LOOSE & BACKED OFF DUCT. RE SEATED DUCT & TIGHTENED CLAMP.
Back to N219UA