N224UA
Service difficulty reports · 144
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N224UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N224UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026102320548Engine · faultedEHM DATA TRENDS INDICATE GAS PATH AND PERFORMANCE SHIFTS. AT NEXT CONVENIENT OPPORTUNITY PLEASE CONDUCT TCC VIS UAL & FUNCTIONAL INSPECTIONS PER AMM 75-24-00-601. IF THERE ARE NO ABNORMAL FINDINGS, ON ACCOMPLISHMENT, FOUND TURBINE COOLING CASE DUCTING BROKEN.SDR CALA2026101220273Battery Pack · no testEMERGENCY LIGHTS - OPERATIONAL TEST WITH THE CONTROL SWITCHES PROCEDURE - EMERGENCY LIGHTS FROM POWER SUPPLY M33098 (DOOR 2R) INOP. M33098 POWER SUPPLY BATTERY PACK REPLACED IAW AMM 33-51-06-960-802.SDR CALA2026051516299Battery Pack · no testDURING ACCOMPLIMENT OF CONFORMITY CHECK, SOME EMERGENCY LIGHTS DOES NOT WORK PROPERLY. PERFORMED POWER SUPPLY BATTERY PACK CAPACITY CHECK IAW AMM 33-51-06-200-801 AND THE BATTERIES HAVE BEEN RE-CHARGED FOR 90 MINUTES. DURING RETEST, IT WAS VERIFIED BATTERIES OSDR CALA2026021113702Proximity Sensor · malfunctionedDOOR FWD CARGO EICAS CAUTION FORWARD CARGO DOOR NOT FULLY CLOSED, LATCHED AND LOCKED. FOUND LOOSE PLASTIC PART OF CARGO STRAP BLOCKING INDICATION OF LATCH SENSOR S52042 TARGET. REMOVED STRAP & INDICATION RETURNED TO NORMAL. FWD DOOR SENSORS S52021, S52022, SDR CALA2025042504248Slide · detachedSLIDE FELL OFF AT DOOR 2L REMOVED 2L SLIDE BUSSEL. UPON ARRIVING AT ACFT FOUND SLIDE 2L OUT OF BUSSEL AND ON JET BRIDGE FLOOR. FURTHER INSPECTION FOUND DOOR ARMING LEVER IN ARMED POSITION. REF AMM 25-66-01, PULLED AND COLLARED CB H10 ON P11, PUT 2L EPAS SWITCHSDR CALA2025031802920Girt Bar · obstructedDOOR 2R DIFFICULT TO OPEN FOUND PLASTIC STRAW ON GRIT BAR, REMOVED STRAW PERFORMED OPS CHECK ON DR2 R REF AMM 52-11-00-710-801 OPS CHECK GOD NO FURTHER FUALT NOTED AT TIME TIMESDR CALA2024111801172Apu · odorTEST FLIGHT DISCREPANCY. . BURNIG SMELL ON FLIGHT DECK PASSING 12K FT SEEM S ELEC REPLACED APU AND ALL LH PACK COMPONENTS. PERFORMED OPERATIONAL CHECKS AND NO SMELL IN COCKPIT OR CABIN. TEST CREW WILL CHECK REFERENCE PER LP 9801346.SDR CALA2024111301120Unknown · odorTEST FLIGHT DISCREPANCY . . BURNING SMELL ON DESCENT PASSING 14K. DISSIPATED ON LDG. ONLY IN COCKPIT. PERFORMED OPS CK OF BOTH PACKS ON GROUND WITH APU REF AMM 21-00-00. COULD NOT DUPLICATE SMELL. OPS CK GOOD. NOTE: REF FIM 21-00 TASK 808. RAN ALL FANS, AND GASDR CALA2024111102826Battery · no testB777-33-3-7019 CABIN - L/H DOOR NO.2 EMERGENCY LIGHT BATTERY PACK (M33096) CAPACITY CHECK FAILED. CABIN DOOR L2 EMERGENCY LIGHT BATTERY PACK REPLACED AND CARRIED OUT INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-00.SDR CALA2024111102825Battery · no testB777-33-3-7019 CABIN - L/H DOOR NO.2 EMERGENCY LIGHT BATTERY PACK (M33096) CAPACITY CHECK FAILED. CABIN DOOR L2 EMERGENCY LIGHT BATTERY PACK REPLACED AND CARRIED OUT INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-00.SDR CALA2024111102824Battery · no testB777-33-3-7019, CABIN DOOR R2 EMER LT PWR PACK M33098 CAPACITY CHECK FAIL. CABIN DOOR R2 EMER LT POWER PACK M33098 REPLACED AND CARRIED OUT INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-00.SDR CALA2024111102823Battery Pack · no testB777-33-3-7019: CABIN - L/H DOOR NO.3 EMERGENCY LIGHT BATTERY PACK (M33406) CAPACITY CHECK FAILED. CABIN L/H DOOR 3 EMERGENCY LIGHT BATTERY PACK (M33406) REPLACED AND CARRIED OUT INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-00.SDR CALA2024111102822Battery · no testB777-33-3-7019, CABIN DOOR R2 EMER LT PWR PACK M33097 CAPACITY CHECK FAIL. CABIN DOOR R2 EMER LT PWR PACK N33097 REPLACED AND TEST NORMAL AS PER AMM 33-51-00.SDR CALA2024111102821Battery Pack · no testB777-33-3-7019 CABIN - R/H DOOR NO.4 EMERGENCY LIGHT BATTERY PACK (M33408) CAPACITY CHECK FAILED. R/H DR4 EMERGENCY LT BATTERY PACK (M33408) REPLACED AND TEST NORMAL AS PER AMM 33-51-00.SDR CALA2024111102820Battery Pack · no testB777-33-3-7019 CABIN - L/H DOOR NO.4 EMERGENCY LIGHT BATTERY PACK (M33407) CAPACITY CHECK FAILED. CABIN L/H DOOR 4 EMERGENCY LIGHT BATTERY PACK (M33407) REPLACED AND CARRIED OUT INSTALLATION TEST RESULT NORMAL AS PER AMM 33-51-00.SDR CALA2024040200922Compressor · stalledPILOTS REPORT COMPRESSOR STALL ON E1 AT ALTITUDE. WITH FLAMES OUT OF TAILPIPE REPORTED. ENGINE ROLLED BACK TO BELOW IDLE THEN RETURNED TO CRUISE POWER. AND NO DEBRIS IN LINE. WORKE FIM TO STEP C(5)A. ON ENGINE CHECK #6, 2.9 BLEED VLV CHECK, PS3 FILTER WAS CLEASDR CALA2023090402683Rub Strip · bentAFT CARGO , UPPER MIDDLE PROTECTIVE RUBSTRIP IS BROKEN & BENT. DAMAGE IS TO AFT CARGO CEILING LINER RUBSTRIP. AREA INSPECTED AND NO FURTHER DAMAGE NOTED. ACCOMPLISHED INTERIM REPAIR PART 1. OF ECRA 2552-01091 REV D. PERFORMED REMOVED AND REPLACED RUB STRIP INSDR CALA2023070702196Cover · unknownDOOR 3R NOT DISPLAYING ARMED DOOR 3R AFT YELLOW INDICATIOR FOR DOOR ARMED TRASNPARENT COVER FOUND INSTALLED BACKWORDS , NOT POSSIBLE TO SEE THE YELLOW MARK IN THAT WAY. COVER REFITTED CORRECTLY AND INDICATION IS VISIBLE WHEN DOOR ARMED.SDR CALA2023061901906Battery Pack · failedEMERGENCY LIGHTING BATTERY PACK FAILED DEEP CYCLE-TEST AT R2 DOO R LOCATION M33097 (ELB PAGE FOR SDR REPORTING ONLY REF VTSAA NR :101999)SDR CALA2023061901905Battery Pack · failedEMERGENCY LIGHTING BATTERY PACK FAILED DEEP CYCLE-TEST AT R2 DOO R LOCATION M33098 (ELB PAGE FOR SDR REPORTING ONLY REF VTSAA NR :101999)SDR CALA2023061901904Battery Pack · failedEMERGENCY LIGHTING BATTERY PACK FAILED DEEP CYCLE-TEST AT R1 DOO R LOCATION M33094 (ELB PAGE FOR SDR REPORTING ONLY REF VTSAA NR :101999)SDR CALA2023061901903Battery Pack · failedLOWER LOBE ATTENDENT REST (LLAR) BACK-UP LIGHT BATTERY FAILED DE EP CYCLE TEST (ELB PAGE FOR SDR REPORTING ONLY REF VTSAA NR:1019 11)SDR CALA2023052901694Electrical Sys · failedELEC BACKUP SYS EICAS ADVISORY BACKUP ELECTRICAL SYSTEM FAILURE. FOUND MAINT MSG 24-45000 NO PFCS INTERFACE STATUS MESSAGE PLACED ON MEL 2425A. DISPLAYED. FIM TASK 24-25 TASK 802 PERFORMED AND ENG GROUND RUN PERFORMED BY FLIGHT CREW MSG CLEAREDSDR CALA2022082202141I/O Module · unserviceableINBOUND FLT. CREW REPORTS BOTH FMC''S LOST WAYPOINTS AND ROUTE INFO TO CAPT''S AND FO''S NAV. DISPLAYS IMMEDIATELY FOLLOWING DEPARTURE. REPLACED BOTH LEFT AND RIGHT I/O MODULES M004. OK TO CONTINUE.SDR CALA2021111702118Charger · inoperativeEMERGENCY LIGHTING BATTERY PACK CAPACITY FUNCTIONAL CHECK FOUND DR2L M33099 EMERGENCY LIGHT BATTERY CHARGER INOP,REFER HAECO NON -ROUTINE LP:9462034,SPEC NO.B777-33-3-7015. PERFORMED BY EMP:V905449,REPLACED THE DR2L M33099 EMERGECNY LIGHT BATTERY CHARGER AND PSDR CALA2021111702117Light · missingFOUND MID GALLEY ONE EMERGENCY LIGHT LENS MISSING,REFER NON-ROUT INE LP:9465920,ORIGINATED BY EMP:V905400,SPEC NO.B777-33-3-7030. PERFORMED BY EMP:V905449,REPLACED THE MID GALLEY EMER LIGHT AND PERFORMED THE EMERGENCY LIGHT OPERATION TEST FOUND NORMAL REF AMM SDR CALA2021111702116Battery · noneEMERGENCY LIGHT BATTERY PACKS CAPACITY CHECK FOUND L2 M33099 EMERGENCY LIGHT BATTERY POOR CAPACITY,REFER HAECO NON-ROUTINE LP :9466604,ORIGINATED BY EMP:V905449,SPEC NO.B777-33-3-7019. PERFORMED BY EMP:V905449,REPLACED THE DR2L M33099 EMER LIGHT BATTERY AND PESDR CALA2018120702513Battery · dischargedREF NR L/P:9464014 - SPEC NO.B777-33-3-7019 - A ZONE L/H FWD CEI LING AREA EMERGENCY LT FOUND LOW CAPACITY. POWER SUPPLY - BATTERY M33424 AT DOOR 1L REPLACED AND OPERATIONA L TEST FND NORMAL AS PER AMM 33-51-06-960-802 REV.84 (OFF P/N:D717-01-100 OFF S/N:41221SDR CALA2018120702512Battery · dischargedREF NR L/P:9464007 - SPEC NO.B777-33-3-7019 - A ZONE R/H CEILING AREA EMERGENCY LIGHT LOW CAPACITY. POWER SUPPLY-BATTERY M33093 AT DOOR 1L REPLACED AND OPERATIONAL TEST FND NORMAL AS PER AMM 33-51-06-960-802 REV.84 (OFF P/N:D717-01-100, OFF S/N:412618;ON P/N:ASDR CALA2018120202478Sign · crackedEXIT IDENTIFIER BASE FND CRACK AT DOOR L2 AFT & DOOR R3 AFT. EXIT IDENTIFIER REPLACED AT DOOR L2 AFT & DOOR R3 AFT, C/O EMERGENCY LT OPERATIONAL TEST, THE RESULT FND NORMAL AS PER AMM 33-51-01-960-802 REV84.SDR CALA2018120202451Battery · dischargedB ZONE LT AFT CEILING AREA EMERGENCY LT FOUND LOW CAPACITY. EMER POWER SUPPLY BATTERY REPLACED AT DOOR L3 (M33400) AND C/O OPERATIONAL TEST OF EMERGENCY LIGHT, THE RESULT FND NORMAL AS PER AMM 33-51-06-960-802 REV84.SDR CALA2018120202450Battery · dischargedC ZONE LT AFT CEILING AREA EMERGENCY LT FOUND CAPACITY. EMER POWER SUPPLY BATTERY M33407 AT DOOR L4. REPLACED AND OPERATIONAL TEST OF EMERGENCY LIGHT FND NORMAL AS PER AMM 33-51- 06-960-802 REV84.SDR CALA2018120202449Battery · dischargedAFT ZONE A2, A3, A4 GALLEY EMERGENCY LT LOW CAPACITY. EMER PWR SUPPLY BATTERY M33408. REPLACED AND OPERATIONAL TEST OF EMERGENCY LIGHT WAS NORMAL REF TO AMM 33-51-06-960-802 REV 84.SDR CALA2018120202448Battery · dischargedA ZONE LT FWD SEAT AREA EMERGENCY LT FND LOW CAPACITY. EMER POWER SUPPLY BATTERY M33096 AT DOOR L2 REPLACED AND OPERATIONAL TEST OF EMERGENCY LIGHT FND NORMAL REF TO AMM 33-51- 06-960-802 REV84.SDR CALA2018062101482Regulator · leakingCREW O2 READS ZERO PSI. FOUND CREW OXYGEN REGULATOR LEAKING, REMOVED REGULATOR AND CREW 02 BOTTLE. OPS CK AND LEAK CKD GOOD PER AMM 35-11-05, 12-15-08 AND 35-11-00. ROTABLE PARTS CHANGE WAS INDICATED - TT 1870821 SN OFF 0188 TT 1293889 SN OFF 6624 IPC REFERESDR CALA2017072802389Skin · damagedDAMAGE AT LEFT SIDE OF FUSELAGE AT BS 667 BETWEEN STRINGERS 24-25L, .114 INCH DEPTH BY 3 INCHES LONG ON PREVIOUS REPAIR DOUBLER ECRA 5330-06127. REPAIR ACCOMPLISHED IAW ECRA 5330-06127 AND AREA WAS NDT AND WAS FOUND CRACK FREE IAW NDT PART 6, 51-00-01 PROCEDSDR CALA2017072802385Battery · dischargedMAIN DECK L3 DOOR, TWO EMERGENCY LIGHT POWER PACKS (M33406 & M33405) FOUND LOW CAPACITY. REPLACED, AND OPS TESTED GOOD IAW AMM 33-51-06-960-802, REV 80.SDR CALA2017072102314Light · brokenGALLEY CTR LEFT A4 GALLEY CTR TTL 3EA LWR EMER LIGHTS FOUND BROKEN. M/D M1 GALLEY CTR A4 GALLEY CTR TTL 3EA LWR EMER LIGHTS REPLACED & FUNCTIONAL TEST C/O FOUND "STATIS" REF AMM 33-51-05-9 60-802 REV 80.SDR CALA2017072102313Light · brokenA & B ZONE PARTITION 4EA LWR EMER LIGHTS FOUND BROKEN. M/D A & B ZONE PARTITION 4EA LWR EMER LIGHTS REPLACED & FUNCTIONAL TEST C/O FOUND "STATIS" REF AMM 33-51-05-960-802 REV 80.SDR CALA2017072102312Light · broken6G, 8C SEAT LWR EMER LIGHTS 2EA FOUND BROKEN. M/D SEAT 6G/8C SEAT LWR EMER LIGHTS REPLACED & FUNCTIONAL TEST C/O FOUND "SATIS" REF AMM 33-51-05-960-802 REV 80.SDR CALA2017022000432Connector · not seatedDOOR 1L EXTERIOR EMERGENCY EXIT LIGHT INOP. REPLACED LIGHT BULB, NO HELP. CHECKED VOLTAGE FOUND 6.2V. INSTALLED SEVERAL BULBS NO HELP. RELAMPED AND RESEATED CONNECTOR D3101P REF WDM 33-51-41, AMM 33- 51-04-960-801. DR 1L EXTERIOR EMER SLIDE LT OPS CK NORMAL.SDR CALA2016020395068Bracket · corrodedEMP COMPARTMENT, HORIZONTAL STAB BODY BONDING JUMPER FWD TORQUE BOX RIB 16L & 16R BRACKET FOUND CORROSION. CARRIED OUT REPLACEMENT IAW EA 2700-01491 & ECRA 2700-01936.SDR CALA2014070291390Pump · malfunctionedENG FUEL VLV L LT HP FUEL SOV POSITION DISAGREES WITH COMMANDED POSITION. STATUS MSG 01 NOT ACTIVE CRUISE MODE DEPENDENT. FMU LT ENG FUEL SOV IS NOT IN COMMANDED POSITION. DB ELEC ENG CONTROL LT ENG CH B. REPLACED LT ENG FUEL PUMP IAW AMM 73-11-01. NO LEASDR CALA2014070291389Pump · leakingCREW REPORTS FLUID, APPEARS TO BE FUEL FROM LT ENG RT FAN COWL AREA. ENG SHUT DOWN, FLUID LEAK STOPPED. REPLACED FUEL PUMP IAW AMM 73-11-01 C2. ACCOMPLISHED LT ENG WET MOTOR & IDLE POWER TEST IAW AMM 71-00-00 TEST NR 2A & 3. NO FUEL LEAKAGE NOTED & ENG OPESDR CALA2014063091364Heat Shield · wornNUMBER 2 HEAT SHIELD LE WAS WORN ON NR 2 PYLON. INTERIM REPAIR ON HEAT SHIELD WAS ACCOMPLISHED. VISUAL INSPECTION OF REPAIR AT INTERVAL OF 375 DAYS WITH THRESHOLD OF 6 JULY 2015. AFTER 29 JULY 2017 THE GENERATED CF ITEM CAN BE CLEARED IF INSPECTION OUTLINEDSDR CALA2013120393403Module · faultyUNABLE TO CONTROL B & C ZONE CEILING & READING LIGHT. REPLACED ZMU 2 IAW AMM, CHECKED OKAY.SDR CALA2013111993047Barrel Nut · damagedWHILE WORKING REVERSE ISSUE FOUND THREAD DAMAGED AT DEACTIVATION PIN INSTALLATION ON RT THRUST REVERSER SLEEVE OF NR 1 ENGINE. INSTALLED NEW BARREL NUT.SDR CALA2013111292872Light · inoperativeLT NR 2 & 3 DOOR OS SLIDE LIGHT FOUND INOPERATIVE. OUTSIDE EMERGENCY LIGHT RELAMPED & CHECKED NORMAL AT LT 2 & 3 DOORS IAW AMM 33-51-04.SDR CALA2013111292871Light · inoperativeSEAT 22D FLOOR PROXIMITY LIGHT FOUND INOPERATIVE. SEAT 22D FLOOR PROXIMITY LIGHT ASSEMBLY REPLACED & TESTED NORMAL IAW AMM.SDR CALA2013102192237Circuit Card · faultedLEFT ENGINE FIRE LOOP 1 & 2 FAULTED. REPLACED BOTH LT & RT FODC FIRE DETECTOR CARDS IN P84 & P85 A10 CARDS IAW MM 26-11-03 & OPS CHECKED GOOD.