N226UA
Service difficulty reports · 154
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N226UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N226UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026092119594Tire Tread · separatedNR 7 MLG TIRE TREAD LOSS CONDITION, FOUND ON ARRIVAL LT.SDR CALA2026090119169Unknown · smokeCREW REPORTED SMOKE IN COCKPIT AND CABIN. SMOKE IN COCKPIT AND CABIN FROM P-300 PANEL HEAT DAMAGE. REF LOG PAGE 3078470 WORK COMPLETED AND SIGN OFFS.SDR CALA2026040615101Battery · no testL4 DOOR, EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED. THE L4 EMERGENCY BATTERY R & R AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026040615100Charger · no testL4 DOOR EMERGENCY LIGHT BATTERY CHARGER TEST FAILED. EMERGENCY LIGHTS CHARGER REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026040615099Battery · no testR4 DOOR EMERGENCY LIGHT BATTERY CAPACITY CHECK FAILED REF HX NR WO.6382596, EMERGENCY LIGHT BATTERY REPLACED AND TESTED NORMAL IAW AMM 33-51-06.SDR CALA2026011112860Power Supply · faultedLEFT FWD M33093 POWER SUPPLY ASOC. EMERGENCY LIGHTS INOPERATIVE DURING AN OPS TEST WITH THE CONTROL SWITCHES PROCEDURE. R & R POWER SUPPLY M33093 IAW AMM 33-51-06-960-803. OPS CKD OK.SDR CALA2025102210407Lamp · no testEMERGENCY LIGHTS ABOVE 40 AND 43 JKL INOPERATIVE DURING OPS TEST WITH THE CONTROL SWITCHES PROCEDURE, EMERGENCY AREA LIGHTS LAMP REPLACED. IAW 33-51-03-960-801.OPS CHK OK.SDR CALA2025101309925A/C Pack · overtempSTRONG FUEL SMELL IN FA LOWER REST. ALSO EXTREME Y HOT REF SDS 21-29-00-006 OPERATION NORMAL. SMELL AND HEAT DUE TO EXTENDED USE OF LEFT PACK ON GROUND. WITH LEFT PACK OFF SMELL AND HEAT DISSIPATED AND OPS CHK NORMAL ADD EMP:U346122SDR CALA2025100709714Battery · dischargedDOOR R1 EPAS BATTERY PACK DOESNT CONTINUOUSLY BLINK GREEN IN ARMED POSITION REPLACED DR R1 EPAS BATTERY PACK REF AMM 52-11-20. OPS CHK GOOD.PARTS USED: 26-5211-9-9003, QTY :1 ROTABLE PARTS CHG:TT # 1179479 SN OFF 5831 PN OFF 26-5211-9-9003.BATTERY, ASSY, OFF SDR CALA2025091108780Generator · failedELEC BACKUP GENERATOR LT EICAS ADVISORY LT BACKUP GENERATOR IS OFF OR HAS FAILED. BACKUP CONVERTER INTERROGATED MAT & DISCOVERED MAINT MESSAGE 24-46080, REQUIRES FIM 24-25 TASK 861. FOUND OIL LEAKAGE UNDER NR 1 ENG. REQUEST INSPECTION FOR L BUG TERMINAL STSDR CALA2025060605324Light · malfunctionedDURING CRUISE THE CABIN EMERG LIGHTS CAME ON 4 APPROX 5 MIN THEN OUT NO FAULT FOUND. EMERGENCY LIGHT ARE FULLY FUNCTIONAL OKAY FOR SERVICE REF AMM TASK 33-51-00SDR CALA2025032103046Light · unsecureSEAT 42D ISLE EMERG EXIT LIGHT HANGING FROM SOCKET SECURED EMERGENCY LIGHT FOR SEAT 42D, OK TO CONTINUE.SDR CALA2025021202302Lamp · inoperativeEXTERNAL EMERGENCY LIGHT AT DOOR 3L INOP FOUND DURING OPERATIONAL TEST WITH THE TEST SWITCHES PROCEDURE. SLIDE/OVERWING LIGHT BULB REPLACED AT DOOR 3L REF.: TASK 33-51-04-960-801 TEST SATISFACTORY. PARTS USED: 99-3351-3-0014,QTY :1SDR CALA2025013102144Trim Panel · damagedCELL PHONE FIRE UNDER 2D DAMAGE TO TRIM FIRE IS OUT. PASSENGER REPORTED PHONE FELL BEHIND SEAT WHILE ASLEEP. WHILE MOVING SEAT TO TTL MODE PHONE CAUGHT BETWEEN SEAT TRACK REMOVED SEAT BACK. FA AND PAX REPORTED THAT SMOKE COMING UNDER THE SEAT, AND THERE WERESDR CALA2024111502873Battery · dischargedBATTERY PACK OF EMERGENCY LIGHT AT DR 2L FND CAPACITY LOW. DR 2L BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL I.A.W AMM 33-51-06.SDR CALA2024111502872Battery · dischargedB777-33-3-7019 - BATTERY PACK OF EMERGENCY LIGHT AT DR 3R FND CAPACITY LOW. DR 3R BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL I.A.W. AMM 33-51-06.SDR CALA2024111502874Battery · dischargedB777-33-3-7019 - BATTERY PACK OF EMERGENCY LIGHT AT DR 1RFND CAPACITY LOW. DR 1L BATTERY PACK REPLACED AND INSTALLATION TEST CARRIED OUT RESULT NORMAL I.A.W. AMM 33-51-06.SDR CALA2024111502861Battery Pack · dischargedBATTERY PACK OF EMERGENCY LIGHT AT DR 4L FND CAPACITY LOW. DR 2R BATTERY PACK REPLACED AND INSTALLATION TEST RESULT NORMAL I.A.W AMM 33-51-06.SDR CALA2024031100687Wheel · missingPDA 1 #10 MLG WHEEL ASSY FELL OFF ON TAKEOFF. ACCOMPLISHED CONDITIONAL INSPECTION FOR PART DEPARTED AIRPLANE IN REF TO AMM 05-51-59. NO DEFECTS NOTED CONDITIONAL INSPECTION WAS ACCOMPLISHED IN REF TO AMM 05-51-59. PARTS TRANSACTION UPDATE R & R #10 TIRE REF ASDR CALA2023041701136Battery Pack · unknownEMERGENCYLIGHT BATTERY PACK M33409 AT DOOR R4 INOP. EPLACED BATTERY PACK M33409 AT R4 DOOR PER AMM 33-51-06-960-802. OPS CCHECKS GOODSDR CALA2023041701135Battery Pack · unknownENTRY FOR SDR REPORTING. REF ST ENGINEERING N/ R 98886, EMERGENCY LIGHTS INOP AT DOORS L1, L2, L3 &. R3. EPLACED BATTERY PACK M33405 AT R3 DOOR PER AMM 33-51-06-960-802.SDR CALA2023041701128Battery Pack · inoperativeREF ST ENGINEERING N/R 98887. EMERGENCY LIGHTS IN FIRST CLASS CEILING INOP. REMOVED & REPLACED POWER SUPPLY BATTERY PACK M33924 AT L1 DOOR. OPS CHECKS GOOD AS PER AMM 33-51-06-960-802. LOG ENTRY FOR SDR REPORTING. WORK PERFORMED BY V943097SDR CALA2022112103192Screw · missingPDA 3 FOUND A SCRREW MISSING FROM PANEL 195LL. SIZE IS SMALLER THAN 15 SQUARE INCHES. INSTALLED A NEW SCRREW. CORRECTION OF PANEL#, CORRECT PANEL# IS 197LL.SDR CALA2022100302647Panel · peelingLEFT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7002} - PANEL 511CB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL REPAIR REMOVED DAMAGED FOIL AND CLEANED AREA ON PANEL 511CB. REPAIRED DAMAGE PERSDR CALA2022100302646Panel · peelingLEFT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7002} -PANEL 511AB HAS PEALING REPAIR TAPE ON INNER SURFACE INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL INSPECTED REPAIR OK TO INSTALL REPAIR REMOVED LOOSE TAPE AND CLEANING PANEL 511AB SDR CALA2022100302645Panel · peelingRIGHT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7003} - PANEL 611CB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL REPAIR REMOVED LOOSE TAPE AND CLEANING PANEL 611CB FER SRM 51-70-14. INSTALLED SDR CALA2022100302644Panel · peelingRIGHT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7003} - PANEL 611AB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL REPAIR REMOVED PEELING TAPE AND CLEANED PANEL. INSPECTION REQUIRED. INSTALLED NSDR CALA2022100302643Panel · peelingLEFT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7002} - PANEL 511QB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL REPAIR REMOVED DAMAGED FOIL AND CLEANED AREA ON PANEL 511QB. INSTALLED NEW TAPE SDR CALA2022100302642Panel · peelingRIGHT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7003} - PANEL 611GB HAS PEALING REPAIR TAPE ON INNER SURFACE. REMOVED TAPE AND CLEANED AREA. INSPECTED PANEL WITH TAPE REMOVED OK TO INSTALL REPAIR INSTALLED TAPED AND SEAL IRW SRM 51-70-14 ON PANEL 6SDR CALA2022100302641Panel · peelingLEFT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7002} - PANEL 511PB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL REPAIR REMOVED TAPE AND CLEANED AREA. INSTALLED NEW TAPE AND EGE SEAL ON PANEL 5SDR CALA2022100302640Panel · damagedLEFT WING LEADING EDGE PANELS FOIL/MESH INSPECT {B777-20-3-7002} - PANEL 511GB HAS PEALING REPAIR TAPE ON INNER SURFACE. INSPECTED AREAS FOR REPAIR TAPE INSTALLATION OK TO INSTALL INSPECT REPAIR OK TO INSTALL PANEL REPAIR REMOVED TAPE AND CLEANED AREA. PANEL TSDR CALA2022093002576Radome · noneSTRONG STATIC DISCHARGE /LIGHTNING STRIKE AT NOSE DURING FLIGH T. FOUND BURNED MARKS ON RADOME UPDATING PICTURES. PERFORMED LIGHTING INSPECTION PHASE 1A AND 1B, FOUND SMALL BURN MARKS ON RADOME, NO OTHER AREAS OF DAMAGE NOTED. OPENED RADOME FOUND NO DAMAGE TSDR CALA2019020100197Beam · dentedREF NR L/P 9470032 FWD CGO DOOR UPR EDGE HAS A DENT AT UPR EDGE APPROX 27 INCHES FROM FORWARD END. FWD CGO DOOR UPR BEAM WEB FWD UPR EDGE APPROX 27 INCHES DENT REP AIRED AS PER ECRA 5234-01069 REV -. REFERENCE LP 8792223 FOR REINSPECTION. ADD EMP:V906646 RII BSDR CALA2019020100196Stringer · corrodedREF NR L/P 9470008 BULK CGO COMPARTMENT BS1958-1979 STRINGER SURFACE CORROSION FOUND ON STR47R. BULK CGO COMPARTMENT BS1958-1979 STR47R STRINGER REPAIRED AS PER SRM 53-70-03 REPAIR1 REV 78 AND ECRA 5341-01146 REV -. ADD EMP:V906646 RII BY TA328SDR CALA2019012800168Stringer · corrodedBLK CGO BILGE BS 2018 TO BS 2020 STR 47R STRINGER SURFACE FND CORROSION, OUTSIDE OF INSP AREA. BULK CGO BILGE BS 2018 TOO BS 2020 STR 47R STRINGER REPAIRED AS PER SRM 53-70-03 REPAIR1 FIG203 REV 78 & ECRA 5341-01146 REV -.SDR CALA2018070301570Battery · dischargedON CHK FOUND R1 DOOR EPAS GREEN LT INOP.SDR CALA2017100603433Battery Pack · dischargedEMERGENCY BATTERY PACK CAPACITY LOW, REPLACED THE BATTERY PACK AND CARRIED OUT OP TEST, FOUND GOOD IAW AMM 33-51-06-960-803, REV 80.SDR CALA2017100603432Light · brokenEMERGENCY LIGHTS FOUND BROKEN. REPLACED THE M/D M1 GALLEY & A4 GALLEY LOWER EMERGENCY LIGHTS AND OPS CHECKED GOOD IAW AMM 33-51-05-960-802, REV 80.SDR CALA2017100203405Light · brokenM/D A & B ZONE PARTITION EMERGENCY LIGHTS FOUND BROKEN. REPLACED EMERGENCY LIGHT ASSEMBLIES.SDR CALA2017100203404Sign · brokenM/D L1 DOOR AFT & R4 DOOR FWD EXIT SIGNS FOUND BROKEN. REPLACED THE SIGNS.SDR CALA2017100203403Light · brokenM/D DOOR 1, CENTER PARTITION, LT & RT TTL LOWER EMERGENCY LIGHTS FOUND BROKEN. REPLACED THE LIGHT ASSYS.SDR CALA2016022995189Battery Pack · failedDOOR 3 LT M33400 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED EMER LIGHT BATTERY PACK ON DOOR 3 FWD & CARRIED OUT OPERATIONAL TEST FOUND NORMAL IAW AMM.SDR CALA2016022995188Battery Pack · failedDOOR 2 LT M33099 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. DOOR 2 LT M33099 AFT EMER LIGHT BATTERY PACK REPLACED. CARRIED OUT OPERATIONS TEST & FOUND NORMAL IAW AMM.SDR CALA2016022995187Battery Pack · failedDOOR 1 LT M33424 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 LT M33424 AFT EMER LIGHT BATTERY PACK & PERFORMED OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995186Battery Pack · failedDOOR 1 LT M33093 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 LT M33093 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995185Battery Pack · failedDOOR 4 RT M33408 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 4 RT M33408 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995184Battery Pack · failedDOOR 1 RT M33094 EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 1 RT M33094 EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995183Battery Pack · failedDOOR 4 RT M33409 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 4 RT M33409 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995182Battery Pack · failedDOOR 3 RT M33401 AFT EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 3 RT M33401 AFT EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.SDR CALA2016022995181Battery Pack · failedDOOR 2 LT M33096 FWD EMER LIGHT BATTERY CAPACITY CHECK FAILED. REPLACED DOOR 2 LT M33096 FWD EMER LIGHT BATTERY PACK & CARRIED OUT OPERATIONS TEST, FOUND NORMAL IAW AMM.