N242WN
Service difficulty reports · 327
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N242WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N242WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2012042303309Light · inoperativeLT OVERWING EXIT SIDEWALL LIGHT INOP. REMOVED AND REPLACED PER AMM.SDR SWAA2012030501871Controller · malfunctionedR2 WINDOW ARCED. REMOVED AND REPLACED NR 3 CONTROLLER, PIGTAIL, AND WINDOW PER MM.SDR SWAA2012021301349Lens · brokenEMERGENCY FLOOR TRACK LENS AT ROW 2 BROKEN. REMOVED AND REPLACED LENS PER AMM.SDR SWAA117850Cover · brokenDURING SCHEDULED MV2 CHECK, FOUND EEPLS COVER BROKEN AT ROW 22. REMOVED AND REPLACED COVER PER MM.SDR SWAA117849Cover · brokenDURING SCHEDULED MV2 CHECK, FOUND EEPLS COVER BROKEN AT ROW 4. REMOVED AND REPLACED COVER PER MM.SDR SWAA116435Light · inoperativeRT EMERGENCY EXIT SIDEWALL LIGHT INOP BETWEEN ROW 12 TO ROW 13. REPAIRED LIGHT PER MM.SDR SWAA116079Light · brokenFWD EEPLS BROKEN. REMOVED AND REPLACED LIGHT ASSY PER MM.SDR SWAA115803Lens · brokenDURING SCHEDULED SPV CHECK, FOUND LT EEPLS LENS BROKEN AT ROW 11. REMOVED AND REPLACED LENS PER MM.SDR SWAA111388Lens · missingLT EEPLS LENS MISSING AT ROW 1. INSTALLED LENS PER MM.SDR SWAA110683Light · inoperativeDURING SCHEDULED MV1 CHECK, FOUND R1 DOOR LOWER EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED LIGHT ASSY PER MM.SDR SWAA105537Cover · crackedDURING SCHEDULED CV CHECK, FOUND LT EEPLS COVER CRACKED BETWEEN ROW 19 TO ROW 23. REMOVED AND REPLACED COVER PER MM.SDR SWAA105536Cover · crackedDURING SCHEDULED CV CHECK, FOUND LT EEPLS COVER CRACKED BETWEEN ROW 1 TO ROW 11. REMOVED AND REPLACED COVER PER MM.SDR SWAA105224Lens · brokenL1 DOOR LOWER EMERGENCY EXIT LENS COVER BROKEN. REMOVED AND REPLACED LIGHT ASSY PER MM.SDR SWAA102942Battery Pack · failedDURING SCHEDULED HC2 CHECK, EMERGENCY EXIT LIGHTS BATTERY FAILED CAPACITY CHECK. REMOVED AND REPLACED BATTERY PACK PER MM.SDR SWAA102941Cover · crackedDURING SCHEDULED HC2 CHECK, FOUND EEPLS COVER CRACKED. REMOVED AND REPLACED COVER PER MM.SDR SWAA102295Light · inoperativeDURING SCHEDULED SPV CHECK, FOUND AFT CABIN CENTER CEILING EMERGENCY EXIT SIGN LIGHT INOP. REMOVED AND REPLACED LIGHT PER MM.SDR SWAA098027Bracket · brokenR1 DOOR EMERGENCY EVAC SLIDE GIRT BAR BRACKET BROKEN. REMOVED AND REPLACED BRACKET PER MM.SDR SWAA096043Light · crackedDURING SCHEDULED MV2 CHECK, FOUND EEPLS CRACKED. REMOVED AND REPLACED EEPLS PER MM.SDR SWAA090925Sign · looseFWD GALLEY EMERGENCY EXIT SIGN LOOSE. REMOVED AND REPLACED SIGN PER MM.SDR SWAA090623Light · inoperativeDURING SCHEDULED HC2 CHECK, FOUND LT OVERWING EMERGENCY EXIT DOOR LIGHT INOP. REMOVED AND REPLACED LIGHT PER MM.SDR SWAA085216Wire · disconnectedFOUND EMERGENCY EXIT FLOOR TRACK LIGHT INOP. RECONNECTED WIRES PER MM.SDR SWAA085224Wire · disconnectedFOUND FIRST EMERGENCY EXIT FLOOR TRACK LIGHT INOP. RECONNECTED WIRES PER MM.SDR SWAA084780Lens · missingDURING SCHEDULED MV1 CHECK, FOUND EEPLS LENS MISSING AT ROW 1 ABC. INSTALLED LENS PER MM.SDR SWAA084723Slide · low pressureL1 DOOR EMERGECNY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA080256Cover · looseEEPLS COVER LOOSE AT ROW 1 ABC. SECURED COVER PER MM.SDR SWAA073412Light · inoperativeDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EXIT LIGHT INOP. REMOVED AND REPLACED LIGHT BULB PER MM.SDR SWAA072260Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.
Back to N242WN