N245WN
Service difficulty reports · 314
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N245WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N245WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2025031001280Seal · out of alignmentRT HORIZONTAL STAB AFT SLIDER SEAL CONTACTING FUSELAGE SKIN. <[01] REPAIRED EXTERNAL FUSELAGE SKIN IAW 25-153-00531 (N245WN - CPZ - REPAIR - SECTION 48 RH FUSELAGE FAIRING SKIN GOUGE DAMAGE) TTG8Q00Z50AA; [02] VERIFIED REPAIRED EXTERNAL FUSELAGE SKIN IAW 25-1SDR SWAA2025031003350Seal · out of alignmentRT HORIZONTAL STAB AFT SLIDER SEAL CONTACTING FUSELAGE SKIN. <[01] REPAIRED IAW EA 25-153-00531 (N245WN - CPZ - REPAIR - SECTION 48 RH FUSELAGE FAIRING SKIN GOUGE DAMAGE) [TTG8Q00Z50AA]; [02] VERIFIED REPAIRED IAW EA 25-153-00531 (N245WN - CPZ - REPAIR - SECTISDR SWAA2025030399679Panel · crackedPANEL 521SB CORNER IS CRACKED <[01]. REPAIRED PANEL 521SB PER SRM 57-41-01-2R-6.SDR SWAA2025022899676Support Bracket · crackedSUPPORT BRACKET FOR FWD SIDE OF PANEL 651BT IS CRACKED. BRACKET IS LOCATED JUST O/B OF R/H WING PICKLEFORK FITTING. <[01] REMOVED & REPLACED SUPPORT BRACKET FOR FWD SIDE OF PANEL 651BT. I.A.W. SRM 51-40-02 AT R/H WHEEL WELL.SDR SWAA2025022700105Seal · damagedRT HORIZONTAL STAB AFT SLIDER SEAL CONTACTING FUSELAGE SKIN<[01] COMPLIED WITH 25-153-0014-WIP1.;[02] C/W 25-153-00514-WIP1 (N245WN - SWA - REPAIR - SECTION 48 FUSELAGE FAIRING SKIN GOUGE DAMAGE). INSPECTION C/W.;[03] COMPLIED WITH 25-153-00514-WIP1 (N245WN - SDR SWAA2024101046791Slide · dislodgedL2 DOOR SLIDE FELL OUT OF THE COMPARTMENT.<[01] R&R EMERGENCY ESCAPE SLIDE LATCH PER AMM 25-66-01 ON AFT ENTRY DOOR.SDR SWAA2024101046792Latch · damagedREF LOG PAGE 2623744; L2 DOOR SLIDE FELL OFF DOOR.<[01] DURING MT 725-61-06; FOUND LATCH ASSEMBLY DAMAGED. REF LOG PAGE 2623744 FOR FINAL RESOLUTION.SDR SWAA2024041171229Lamp · inoperativeFORWARD SERVICE DOOR EMERGENCY SLIDE LIGHT INOP. RE LAMPED FWD SERVICE DOOR EMERGENCY SLIDE LIGHT AND PERFORMED GOOD OPERATIONAL TEST PER AMM 33-51-04-960-801.SDR SWAA2024041171230Bulb · inoperativeLEFT OVERWING FORWARD EMERGENCY LIGHT BULB OUT. REPLACED THE LAMP IN THE LH OVERWING FWD EMERGENCY LIGHT AND PERFORMED GOOD OPERATIONAL TEST PER AMM 33-51-01-960-801.SDR SWAA2024041669481Support Bracket · brokenWIRE SUPPORT BRACKET BROKEN B.S. 867 STR 2R. R & R THE SUPPORT BRACKET IAW SRM 51-40-02-0G-0, & DWG 146A7901, REV-.SDR SWAA2024041567909Web · crackedCRACK NOTED IN 1EA HOLE AT FSD THRESHOLD SHEAR WEB BS295; RBL54.5; WL208 AT 9:00 POSITION; MARKED.<[01] UPDATED MEASUREMENT TABLE.;[02] REMOVED AND REPLACED FSD THRESHOLD WEB BETWEEN BS 291-332; WL 208 PER SRM 51-40-02 AND DWG:141A8310 REV-.SDR SWAA2024041566610Support · chafedFUSELAGE LOWER FAIRING SUPPORT IS CHAFED FROM STA 663 TO 663+10; LBL 27; WL 148.5<[01] UP DATE CORROSION LEVEL;[02] CERTIFY;[03] ALL STEPS COMPLETED.;[04] REPLACED FAIRING SUPPORT IAW SRM 51-40-02- AND DWG 149A7216SDR SWAA2024041566789Stiffener · crackedLEFT HORIZONTAL STAB RIB AT STAB STA. 120.30 FWD ATTACH STIFFENER CRACKED<[01] REMOVED CRACKED FWD ATTACH STIFFENER IAW SRM 51-40-02-0G-0. RECEIVED NEW STIFFENER (PN: 182A2405-13; LOT: 1558499-1) AND INSTALLED IAW SRM 51-40-02-0G-0.;[02] UPDATE TO CORRECTIVE ASDR SWAA2024041566608Floor Panel · debondedAFT FLOOR PANEL 242UF UPPER SKIN HAS MULTIPLE DISBONDS. (MARKED)<[01] AFT FLOOR PANEL 242UF UPPER SKIN DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED FLOOR PANEL 242UF HAS BEEN REPAIRED PER SRM 53-00-50SDR SWAA2024041565974Support Bracket · crackedAFT CARGO BAY FWD BULKHEAD DIAGONAL PANEL SUPPORT BRACKET CRACKED<[01] REPLACED FWD BULKHEAD SUPPORT IAW IAW SRM 51-40-02-0G-0 AND DWG 144A2600;;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041565976Vapor Barrier · crackedR/H VAPOR BARRIER CRACKED AT BS 663 RBL 27 WL 148<[01] ALL WORK ACCOMPLISHED ON TTG8Q00SV07;[02] ALL WORK ACCOMPLISHED ON TTG8Q00S3V07;[03] VERIFIED CORRECTIVE ACTION 2SDR SWAA2024041565044Bracket · crackedDURING REMOVAL R/H VAPOR BARRIER BS 663 RBL 45 TO RBL 54 FOUND BRACKET P/N 276A9183-2 CRACKED<[01] LOCATED AND DRILLED NEW BRACKET ASSY P/N 276A9183-2 IAW SRM 51-40-05 AND DWG 111A1001<BR>REQ. OK TO INSTALL;[02] VERIFIED CORRECTIVE ACTION 1. OK TO INSTALL GIVESDR SWAA2024041564887Floor Panel · delaminatedFLOOR PANEL 241XF HAS DELAMINATION ON LOWER SURFACE.<[01] FLOOR PANEL 241XF WITH DELAMINATION ON LOWER SURFACE WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] FINAL INSPECTION. JOB COMPLETE.SDR SWAA2024041164731Floorbeam · crackedFLOORBEAM CRACKED AT FASTENER HOLE; BS 328 RBL 24 WL 208, NDT HFEC INSPECTED SURFACE IAW NDTM PART 6; 51-00-00, PROC 23, .5' LONG CRACK NOTED. FROM THE HOLE TO THE EDGE OF THE FLOORBEAM. BS 328 FLOORBEAM WAS REPAIRED DUE TO CRACK AT FLOORBEAM HOLE IAW SRM SDR SWAA2024041164732Stub Frame · crackedFWD GALLEY DOORWAY FWD STUB FRAME CRACKED; BS 294.5, RBL 54, WL 208.1. NDT HFEC INSPECTED SURFACE PER 737 NDTM PART 6; 51-00-00; PROC 23; 1' LONG CRACK NOTED. EDGE TO EDGE. INSTALLED CLIP RBL 56, WL 208 IAW SRM 53-10-15-2R-7 AND DWG:141A8310;REV -. REPAISDR SWAA2024041164724Support Fitting · crackedFED DOORWAY FWD LOWER SUPPORT FITTING CRACKED; BS 294.5 + 1'; STR 16L; IB RADIUS; MARKED<[01] NDT HFEC INSPECTED SURFACE PER 737 NDTM PART 6; 51-00-00; PROC 23; .750' LONG CRACK NOTED. MARKED DIRECTION AND END OF CRACK. UPDATED STEPS 1-3 NO ALLOWABLE DAMAGE SDR SWAA2024041564271Support · corrodedCORROSION ON ACB FLOOR TO SIDEWALL SUPPORT STA-727 TO 847 LBL-20<[01] TASK COMPLETED.;[02] REPLACED AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT BS 727 - BS 847 LBL 20 IAW SRM 51-40-05-0G-0; SRM 53-00-53-2R-6 AND DWG 146A7502 AND DWG 146A7500;[03] VERIFIED CORRECTISDR SWAA2024041564289Support Angle · crackedCRACK ON SUPPORT ANGLE ACB COMMON TO POTABLE WATER SERVICE PANEL.<[01] REMOVED AND REPLACED SUPPORT ANGLE COMMON TO WATER SERVICE PANEL IAW SRM 51-40-02 AND DWG 147A7221 REV: -DUE TO NO FOUND ALLOWABLE DAMAGE LIMIST ON SRM;[02] VERIFIED CORRECTIVE ACTION COMPLSDR SWAA2024041564293Support · crackedCRACK BULKHEAD SUPPORT STA-947 LBL-13<[01] REPLACED BULKHEAD SUPPORT IAW SRM 51-40-02 AND DWG 149A8103;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041564264Web · corrodedCORROSION ON FWD CARGO DOORWAY THRESHOLD WEB AT BS 484; RBL 31; BS468; RBL 29; AND BS 452; RBL 29<[01] REMOVED AND REINSTALLED FWD CARGO DOORWAY THRESHOLD WEB FROM BS 440 TO BS 492.4; RBL 22; IAW SRM 51-40-02-0G-0 AND DWG 143A8330; ID: 0030; REV: -SDR SWAA2024041575102Track · corrodedCORROSION ON FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B RBL-3<[01] REMOVED AND REPLACED FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B RBL-3 IAW SRM 51-40-02 AND DWG:146A7500 REV:A;[02] VERIFIED CORRECTIVE ACTION ITEMS 1; CARD COMSDR SWAA2024041564276Web · corrodedCORROSION ON FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B RBL-3<[01] REMOVED AND REPLACED FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B RBL-3 IAW SRM 51-40-02 AND DWG:146A7500 REV:A;[02] VERIFIED CORRECTIVE ACTION ITEMS 1; CARD COMSDR SWAA2024041575103Track · corrodedCORROSION ON FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3<[01] REMOVED AND REPLACED FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3 IAW SRM 51-40-02 AND DWG:146A7500 REV:A;[02] VERIFIED CORRECTIVE ACTION & MEASUREMENTS FISDR SWAA2024041564266Web · corrodedCORROSION ON FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3<[01] REMOVED AND REPLACED FASTENERS COMMON TO WEB AND RAIL TRACK ACB STA-727A TO 727B LBL-3 IAW SRM 51-40-02 AND DWG:146A7500 REV:A;[02] VERIFIED CORRECTIVE ACTION & MEASUREMENTS FISDR SWAA2024041564267Stringer Clip · corrodedCORROSION ON STRINGER CLIP ACB STA-767 STR-26R<[01] CORRECTION TO CORROSION LEVEL 1;[02] CERTIFY;[03] CORROSION LEVEL CORRECTION;[04] CORRECTED;[05] VERIFIED TASK COMPLETEDSDR SWAA2024041564277Stringer Clip · corrodedCORROSION ON STRINGER CLIP ACB STA-787 STR-26R<[01] REMOVED AND REPLACED CLIP AT ACB STA-787 STR-26R IAW SRM 51-40-02 AND DWG 146A1262 REV.;[02] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.SDR SWAA2024041564278Stringer Clip · corrodedCORROSION ON STRINGER CLIP ACB STA-807 STR-26R<[01] REMOVED AND REPLACED STRINGER CLIP P/N 146A1010-27 LOCATED AT ACB STA-807 STR-26R IAW SRM 51-40-02 AND DWG 146A1263 REV: A DUE TO NO FOUND ALLOWABLE DAMAGE LIMITS OS SRM.SDR SWAA2024041564268Stringer · corrodedCORROSION ON STRINGER CLIP ACB STA-847 STR-27L<[01] REMOVED AND REPLACED CLIP AT ACB STA-847 STR-27L IAW SRM 51-40-02-0G-0 AND DWG 146A1281 REV.-;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041564270Support · corrodedCORROSION ON ACB FLOOR TO SIDEWALL SUPPORT STA-727 TO 767 RBL-20<[01] REMOVED FABRICATED AND INSTALLED ACB FLOOR TO SIDEWALL SUPPORT BS 727 TO BS 767 RBL20 WL 156 MATERIA USING BAC1496-377#7075T62 LOT:1549286-2 IAW SRM 51-40-02- DWG 146A7502 REV:- AND DWG 146ASDR SWAA2024041564297Shield · corrodedCORROSION ON ACB FWD SHIELD.<[01] CORROSION ON ACB FORWARD SHIELD FOUND TO BE OUT OF ALLOWABLE DAMAGE LIMITS DUE TO NO ALLOWABLE GIVEN IN SRM. REPAIR BY REPLACEMENT IAW SRM 51-10-02;[02] VERIFIED.SDR SWAA2024041564298Strap · corrodedCORROSION ON FWD FLOORBOARD STRAP ACB STA-767+3''<[01] RECEIVED NEW ACB FLOOR BOARD T-STRAP BS 767+3' FROM STORES. PART IS TO BE INSTALLED ON CUSTOMER CARD #TTG8Q00RJLCR.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024041564299Strap · corrodedCORROSION ON NUT-PLATE STRAP ACB STA-787+3'' RBL-21<[01] REMOVED AND INSTALLED NEW NUT-PLATE STRAP ON AFT CARGO BAY BS 787+3'; RBL 21 I.A.W. SRM 51-40-02-0G-0; DWG# 146A8340 SHEET 19;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.SDR SWAA2024041564284Strap · corrodedCORROSION ON TENSION STRAP THRESHOLD AREA ACB DOOR<[01] REMOVED AND INSTALLED NEW TENSION STRAP ON ACB P/N 146A8128U14 I.A.W. SRM 51-40-02-0G-0 DWG.# 146A8120SDR SWAA2024041564285Web · corrodedCORROSION ON THRESHOLD WEB ACB<[01] UPDATE TO WATERLINE;[02] CERTIFY;[03] 01 - REMOVED AND REPLACED PER [SRM 51-40-02-0G-0-A00729 (GENERAL - FASTENER INSTALLATION AND REMOVAL - AIRFRAME - PERMANENT)]<BR><BR>TASK CARD COMPLETED.;[04] VERIFIED CORRECTIVE ACTION SDR SWAA2024041564291Cargo Track · corrodedCORROSION ON RAIL TRACK ACB STA-927+18'' RBL-8<[01] REMOVED AND REPLACED RAIL TRACK BETWEEN BS 887 TO BS 947+3'; RBL 8 AT ACB PER SRM 51-40-02.AND DWG 147A7500 REV: - DUE TO FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2;[02] VERIFIED CORRECTIVE ACTION COMPLETSDR SWAA2024041564296Cargo Track · corrodedCORROSION CARGO TRACK TIE-DOWN ACB LBL-17 STA-807. UPON FURTHER INVESTIGATION DEFECT IS FOUND AT CARGO TRACK TIE-DOWN ACB LBL-17 STA- 787<[01] REMOVED CORROSION ON CARGO TRACK TIE-DOWN ACB LBL-17 STA-787. DEFECT FOUND TO BE IN LIMITS. TREATED AND PRIMED REWORKSDR SWAA2024041563769Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9; LBL 11; WL 208.1.<[01] UPDATED MEASUREMENT TABLE AND STEPS 1-3;[02] UPDATED STEPS 4;5;[03] STEP 5 COMPLETE;[04] MEASURMENT TABLE EDIT. PART IS NOT RII FOR REMOVAL AND REPLACEMENT.;[05] CERTIFY EDIT TO MEASUREMENT TABLE;[06] STSDR SWAA2024041563776Floor Support · crackedCRACKED INTERCOSTAL AT STA 344+9 BL 0; WL 208.1<[01] STARTED FASTENER REMOVAL IAW SRM 51-40-02-0G-0;[02] UPDATED STEPS 1-3;[03] STEPS 4;5 UPDATED;[04] UPDATED MEASUREMENT TABLE;[05] STEP 5 COMPLETE;[06] EVALUATED CRACKED INTERCOSTAL AND FOUND IT TO BE OUT OF LSDR SWAA2024041563770Floor Support · corrodedCORROSION ON INTERCOSTAL FASTENER HOLES AT STA 328+3; AND STA 328+11; LBL 12; WL 208.1<[01] UPDATE STEPS 1;2;[02] UPDATED MEASUREMENT TABLE;[03] UPDATE STEP 3;[04] STEP 3 COMPLETE.;[05] ADDED SUMMARY STATEMENT TO STEP 3.;[06] SUMMARY STATEMENT: INTERCOSTAL OUTSDR SWAA2024041563771Floor Support · crackedCRACKED INTERCOSTAL AT STA 312+8; LBL 46; WL 208.1<[01] UPDATED MEASUREMENTS TABLE;[02] REMOVED AND REPLACED INTERCOSTAL AT BS312-BS328 LBL46; PER SRM 51-40-02 AND DWG#141A5400.;[03] VERIFIED ACTION #2SDR SWAA2024041563782Floor Support · crackedCRACKED INTERCOSTAL AT STA 277+7 AND 277+13; BL 0; WL 208.1<[01] REMOVED AND REPLACED INTERCOSTAL AT BS 277-BS294.5 PER SRM 51-40-02 AND DWG#141A5400.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563795Floorboard · delaminatedDELAMINATION ON 242TF FLOORBOARD AFT WET AREA.<[01] DELAMINATION ON 242TF FLOORBOARD AFT WET AREA WAS REPAIRED IAW SRM 53-00-50-2R-1;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024041563792Floorboard · delaminatedDELAMINATION ON 241AEF FLOORBOARD AFT WET AREA.<[01] FLOOR PANEL 241AEF AFT WET AREA DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563791Floor Panel · delaminatedDELAMINATION ON 241ADF FLOORBOARD AFT WET AREA.<[01] FLOOR PANEL 241ADF AFT WET AREA DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2024041563790Floorboard · delaminatedDELAMINATION ON 241ZF FLOORBOARD AFT WET AREA.<[01] FLOORBOARD 241ZF DELAMINATION DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1.<BR><BR>ATTACHED CURE SHEETS TO THIS FAULT.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.
Back to N245WN