N247SY
Service difficulty reports · 18
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N247SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N247SY' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2026050275974Control Lever · warning messageFLAP FAIL CAUTION MESSAGE, RETURNED TO FIELD QRH DID NOT CLEAR MESSAGE. (FLIGHT 3952) INTERROGATED CMC FOUND FAULT CODE 27512014ACE, TROUBLESHOT PER FIM 27-51-00-810-802-A. DETERMINED LH OUTBOARD FLAP ACTUATOR NUMBER #4 CAUSING FAULT. COMPLIED WITH TASK CARDSDR SWIA20250116221Seat Track · gougedRH FLOOR SEAT TRACK 74/84 HAS PAINT DAMAGE OR GOUGES ON OR AFT OF FRAMES 74, 76, 78, 79, 80, 81 AND 83. (C-CHECK RO 1/15/2025) REMOVED AND REPLACED PORTION OF R/H FLOOR SEAT TRACK BETWEEN FR 81-84 REF: ETD2022-170-022163-BSDR SWIA202265375None · corrodedCORROSION- FRAME 88 STRINGER 28R SHEAR CLIP CORRODED. (C CHECK RO 4/16/22) REMOVED AND REPLACED SHEAR CLIP AT FR 88 STRINGER 27R-28R REF ERJ 175 SRM 51-40-08. SEE CONTINUE CARD FOR WORK PERFORMED.SDR SWIA202265384None · crackedFR12 CENTERLINE COCKPIT FLOOR SUPPORT BEAM HAS ATTACH ANGLE CRACKED UNDER CANNON PLUGS AS MARKED (C CHECK RO 4/16/22) / REMOVED AND REPLACED FR12 CENTERLINE COCKPIT FLOOR SUPPORT BEAM ATTACH ANGLE REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-2SDR SWIA202265383None · crackedLH MLG - FRAME 52 "L" ANGLE CRACKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED LH MLG - FRAME 52 "L" ANGLE REF SRM 51-40-08. RESTORED SURFACE PROTECTION REF SRM 51-23-06SDR SWIA202265388None · wornRH ELEVATOR HINGE FITTING # 2 HARDWARE IS WORN. (C CHECK RO 4/16/22) REMOVED AND REPLACED RH ELEVATOR HINGE FITTING # 2 HARDWARE ON RACK REF: ERJ 175 AMM 27-31-05-01-ASDR SWIA202265387None · wornRH ELEVATOR HINGE FITTING # 3 HARDWARE IS WORN. (C CHECK RO 4/16/22) REMOVED AND REPLACED RH ELEVATOR HINGE FITTING # 3 HARDWARE ON RACK REF: ERJ 175 AMM 27-31-05-01-ASDR SWIA202265386None · wornLH ELEVATOR HINGE FITTING # 2 HARDWARE IS WORN. (C CHECK RO 4/16/22) REMOVED AND REPLACED HARDWARE FOR LH ELEVATOR #2 HINGE FITTING REF AMM 27-31-05. REFER TO CP 24530014 FOR FINAL INSTALLATIONSDR SWIA202265385None · wornLH ELEVATOR HINGE FITTING # 3 HARDWARE IS WORN. (C CHECK RO 4/16/22) REMOVED AND REPLACED HARDWARE FOR LH ELEVATOR #3 HINGE FITTING REF AMM 27-31-05. REFER TO CP 24530014 FOR FINAL INSTALLATIONSDR SWIA202265382None · corrodedSTILL RIGHT FWD WET AREA FRAME 12-14 TWO AREAS OF CORROISION AS MARKED. (C CHECK RO 4/16/22) CORROSION OUT OF LIMITS REF. EMB SRM 53-10-10/AD06. REMOVED AND REPLACED SILL AT RIGHT FWD WET AREA FRAME 12-14 REF. EMB SRM 51-40-08.SDR SWIA202265376None · crackedCRACKED SHEAR CLIP FRAME 12 @ INTERCOSTAL OTBD OF PILOT OTBD SEAT TRACK (C CHECK RO 4/16/22) REMOVED AND REPLACED SHEAR CLIP FRAME 12 @ INTERCOSTAL OTBD OF PILOT OUTBD SEAT TRACK REF SRM 51-40-08. APPLIED SURFACE PROTECTION REF SRM 51-23-06 AND CIC PROTECTSDR SWIA202265381None · corrodedCENTER SHEAR PANEL AT FR87 /FR88 HAS CORROSION AROUND GALLEY BARREL NUT AS MARKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED CENTER SHEAR PANEL AT FR87 /FR88 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202265380None · corrodedR/H I/B SHEAR PANEL HAS CORROSION AS MARKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED R/H I/B SHEAR PANEL REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202265379None · corrodedR/H I/B SPLICE AT FR89 HAS CORROSION AS MARKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED R/H I/B SPLICE AT FR89 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202265378None · corrodedR/H GUSSET PLATE AT FR90 HAS CORROSION AS MARKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED R/H GUSSET PLATE AT FR90 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA202265377None · corrodedR/H PANEL SUPPORT AT FR89 TO FR90 HAS CORROSION AS MARKED. (C CHECK RO 4/16/22) REMOVED AND REPLACED R/H PANEL SUPPORT AT FR89 TO FR90 REF SRM 51-40-08. SEE CONTINUATION CARD FOR WORK PERFORMED.SDR SWIA2020090852312Skin · damagedREFERENCE CAMP 21414889 FOR ORIGINAL DISCREPANCY OF OUT OF LIMITS THROUGH DAMAGE TO LEFT AFT FUSELAGE, LOCATED BETWEEN FRAMES 83 AND 85 AND STRINGERS 19 AND 20. PERFORM DAMAGE REMOVAL AND CUTOUT FOR ETD SUBMISSION PER MANUFACTURERS INSTRUCTIONS FOR PREPARATIOSDR SWIA2020090852311Skin · damagedREFERENCE CAMPS 21404308 AND 21414879. OUT OF LIMITS THROUGH DAMAGE TO LEFT AFT FUSELAGE, LOCATED BETWEEN FRAMES 83 AND 85 AND STRINGERS 19 AND 20. MEASURES 18 1/2 INCHES LONG AND 5 INCHES WIDE WITH A GOUGE MEASURING 4 3/4 LENGTH 0.025 DEEP AND 0.25 WIDE. R
Back to N247SY