N252WN
Service difficulty reports · 323
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N252WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N252WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2024072404678Angle · corrodedCORROSION ON LH Z ANGLE NEAR F.E.D MOP SILL BS 344; LBL 62; WL 208.<[01] REMOVED CORROSION ON ZEE CHORD ANGLE AT DISCREPANCY AREA: L = 1'; W= 1'; MAX. MATERIAL LOSS= 0.004'; WAS FOUND WITHIN LIMIT PER SRM 53-10-15-1A-1; STEP 4.C(2)A; FIG. 108; DETAIL D.<BR><BRSDR SWAA2024072404683Support · corrodedAFT CARGO L/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727E-747MARKED CORRECTION TO LOCATION=AFT CARGO R/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727E-747MARKED<[01] REMOVED AND REPLACED RH FLOOR TO SIDEWALL SUPPORT BSSDR SWAA2024072404684Support · corrodedAFT CARGO L/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727D-727E MARKED AFT CARGO R/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727D-727E MARKED<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH THE CUSTOMER CARD # TTG8Q00U4KSDR SWAA2024072404685Support · corrodedAFT CARGO L/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727C MARKED AFT CARGO R/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 727C MARKED<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH THE CUSTOMER CARD # TTG8Q00U4KVZ;[02] VESDR SWAA2024072404603Sill Drain · corrodedCORROSION FOUND ON LOWER FORWARD GALLEY DOOR CUTOUT SURROUND STRUCTURE MOPSIL WL 208; RBL 64; BS 312-360.<[01] REMOVED AND REPLACED MOP SILL WL 208; RBL 64; BS 312-360; PER SRM 51-10-02-0G-0; SRM 51-40-02 AND DWG 141A8310.;[02] VERIFIED CORRECTIVE ACTION 1.SDR SWAA2024072404598Shield · corrodedAFT CARGO DOOR SHEILD CORROSION AT STA 767 TO 787 LBL 20 ON 6 EA. AREAS MARKED CORRECTION FOR LOCATION: CORROSION IS LOCATED AT BS 767 TO 787 RBL 20<[01] REMOVED AND REPLACED AFT CARGO DOOR SHIELD BS767 TO BS 794.25 RBL 20 IAW SRM 51-40-02 AND DWG 146A0081 ID:SDR SWAA2024072404681Intercostal · corrodedAFT CARGO INTERCOSTAL HAS CORROSION AT STA 767 +6 ON 2 EA. NUT PLATE HOLES MARKED<[01] VERIFIED STEP 3;4 COMPLETE.;[02] REMOVED AND REPLACED ON AFT CARGO BAY INTERCOSTAL ITEM 146A8123-20 LOT#1568533-1 IAW SRM 51-40-02 AND DWG 146A0081 ID:0031 REV:-;[03] VERIFISDR SWAA2024072404679Support · corrodedAFT CARGO L/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 747-767 MARKED AFT CARGO R/H FLOOR TO SIDEWALL SUPPORT HAS CORRODED NUT PLATE HOLE AT STA 747-767 MARKED<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH THE CUSTOMER CARD # TTG8Q00U4KVZ;[SDR SWAA2024072404689Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 767-787 CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 767-787<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH THE CUSTOMER CARD # TTGSDR SWAA2024072404690Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 747-767 CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 747-767<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH THE CUSTOMER CARD # TTGSDR SWAA2024072404695Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727E-747 CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727E-747<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD# TTG8Q0SDR SWAA2024072404696Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727D-727E CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727D-727E<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD# TTG8SDR SWAA2024072404697Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727C-727D CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727C-727D<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD# TTG8SDR SWAA2024072404698Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727B-727C CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727B-727C<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD# TTG8SDR SWAA2024072404699Support · corrodedRH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727-727A CORRECTION TO FAULT DESCRIPTION: LH AFT CARGO FLOOR TO SIDEWALL SUPPORT HAS CORRODE NUT PLATE HOLES STA 727-727A<[01] THIS TASK CARD WILL BE ACCOMPLISHED WITH CUSTOMER CARD# TTG8Q0SDR SWAA2024072404701Floorbeam · corrodedCORROSION ON RH FLOOR BEAM BS 1013; RBL 38; WL 208 CORROSION ON RH SHEAR WEB BS 1013 RBL 38 WL 208<[01] REWORKED CORRODED AREA ON RH FLOOR BEAM BS 1013; RBL 38; WL 208; IAW EA 24-153-01754.;[02] CORRECTION TO ACTION 1: CORROSION FOUND TO BE OUT OF LIMITS DUE TSDR SWAA2024072404702Web · corrodedCORROSION ON RH VERTICAL WEB; BS 1016; RBL 35; RBL11; BS 1032; RBL 8. CORRECTION-CORROSION ON RH VERTICAL WEB BS 1016; RBL 35 RBL11 BS 1032 RBL 8 WL 208.<[01] REWORKED CORRODED AREAS ON RH VERTICAL WEB; BS 1016; RBL 35; RBL 11; BS 1032; RBL 8 IAW EA 24-153-017SDR SWAA2024072404703Strap · corrodedCORROSION ON LH VERTICAL BEAM STRAP BS 1016-1024; LBL 3; WL 208<[01] REMOVED AND REPLACED TENSION STRAP AT BS 1016-1024; LBL 3; WL 208 IAW SRM 51-40-02-0G-0 AND DWG # 147A5600 REV B;[02] VERIFIED STEPS AND CORRECTIVE ACTION ITEM; CARD COMPLETE.SDR SWAA2024072404693Strap · corrodedCORROSION ON RH VERTICAL BEAM STRAP BS 1016-1024; RBL 3; WL 208<[01] REMOVED AND REPLACED TENSION STRAP AT BS 1016-1024; RBL 3; WL 208 IAW SRM 51-40-02-0G-0 AND DWG # 147A5730 REV C;[02] VERIFIED CORRECTIVE ACTION ITEM AND STEPS; CARD COMPLETE.SDR SWAA2024072404692Web · corrodedCORROSION ON LH VERTICAL WEB; BS 1026; LBL 21; WL 208.<[01] REMOVED CORROSION ON LH VERTICAL WEB; BS 1026; LBL 21 WL 208 AND REWORKED AREA PER EA 24-153-01750.;[02] VERIFIED CORRECTIVE ACTION ENTRY 1.SDR SWAA2024072304682Floor Panel · delaminatedAFT FLOOR PANEL 241ACF HAS UPPER SURFACE DELAMINATION AND DAMAGED INSERTS<[01] AFT FLOOR PANEL 241ACF HAD UPPER SURFACE DELAMINATION AND DAMAGED INSERTS REPAIED IAW SRM 53-00-50-2R-6;[02] JOB COMPLETE.SDR SWAA2024072304677Floorbeam · corrodedCORROSION ON CROSSBEAM LBL 0; BS 294.5; WL 208.<[01] REPAIRED FLOOR BEAM BS 294.5; BL 0; WL 208 IAW SRM 53-10-51-2R-14 REPAIR 14;[02] VERIFIED ACTION 1.;[03] JOB COMPLETE.SDR SWAA2024072304680Web · corrodedCORROSION ON FWD GALLEY DOOR CUTOUT SURROUND LOWER STRUCTURE WL 208; BS 344+2; RBL 66. CORROSION ON FWD GALLEY DOOR CUTOUT SURROUND LOWER STRUCTURE WEB WL 208 BS 328+2 RBL 66<[01] REMOVED AND REPLACED ON FWD GALLEY DOOR CUTOUT SURROUND LOWER STRUCTURE WEB IAW SDR SWAA2024072304691Floorbeam · corrodedCORROSION ON LT FLOORBEAM; BS 986.5; LBL 45; WL 208.<[01] ACCOMPLISHED LH BS986.5 LBL 45 FLOORBEAM REPAIR IAW SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 4;[02] VERIFIED. ITEMS AND STEPS; CARD COMPLETE.SDR SWAA2024072304295Frame · crackedFWD GALLEY DOORWAY; BS 294.5 STR 17R FWD SUB-FRAME CRACKED AT THE IB FASTENER HOLE; MARKED.<[01] NDT HFEC INSPECTED SURFACE PER 737 NDTM PART 6; 51-00-00; PROC 23; .400' CRACK NOTED. MARKED DIRECTION.<BR><BR>EQUIP ID ATS2353 DUE 01/25;[02] REMOVED AND REPLACEDSDR SWAA2024072304296Intercostal · crackedFWD ENTRY DOORWAY; BS 294.5 STR 16L; INTERCOSTAL CRACKED AT THE IB RADIUS; MARKED.<[01] NDT HFEC INSPECTED SURFACE PER 737 NDTM PART 6; 51-00-00; PROC 23; .400' CRACK NOTED. DIRECTION MARKED.<BR><BR>EQUIP ID ATS2353 DUE 01/25;[02] VERIFIED STEPS 3;4 COMPLETE; SDR SWAA2024072403541Floor Panel · pulledAFT FLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW FLOOR PANEL 241UF HAS BEEN COMPLETED IAW SRM 53-00-50-2R-0 AND BOEING DWG: 146A5810 ID: 0054.SDR SWAA2024072403542Floor Panel · pulledAFT FLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED AFT FLOOR PANEL 241VF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-22 ITEM 161.;[02] VERIFIED CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024072403543Floor Panel · pulledAFT FLOOR PANEL 241WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED AFT FLOOR PANEL 241WF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-22 ITEM 185.;[02] VERIFIED CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024072403544Floor Panel · pulledPANEL 231FF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] PANEL 231FF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARAR 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024072403546Floor Panel · pulledFLOOR PANEL 232FF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW FLOOR PANEL 232FF HAS BEEN COMPLETED IAW SRM 53-00-50-2R-0 AND BOEING DWG: 143A5810 ID: 0116.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024072403547Floor Panel · pulledFLOOR PANEL 232QF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW FLOOR PANEL HAS BEEN COMPLETED IAW SRM 53-00-50-2R-0 AND BOEING DWG: 143A5810 ID: 0107.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024072403548Floor Panel · delaminatedFWD FLOOR PANEL 222AF HAS UPPER SURFACE DELAMINATION<[01] DUE TO EXTENT OF DAMAGE; FLOOR PANEL 222AF WAS REPLACED IAW SRM 51-10-02-0G-0 PAR 9.A (1).;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024072403549Floor Panel · delaminatedFWD FLOOR PANEL 221AF HAS UPPER SURFACE DELAMINATION<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED FWD FLOOR PANEL 221AF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-50D ITEM 35.;[02] VERIFIEDSDR SWAA2024072403550Floor Panel · delaminatedFWD FLOOR PANEL 222BF HAS UPPER SURFACE DELAMINATION<[01] FWD FLOOR PANEL 222BF WITH UPPER SURFACE DELAMINATIONS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024072403551Floor Panel · delaminatedFWD FLOOR PANEL 221BF HAS UPPER SURFACE DELAMINATION<[01] FWD FLOOR PANEL 221BF WITH UPPER SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024072403552Floor Panel · delaminatedFWD FLOOR PANEL 221DF HAS UPPER SURFACE DELAMINATION<[01] FWD FLOOR PANEL 221DF WITH UPPER SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024072403555Floor Panel · delaminatedFWD FLOOR PANEL 221EF HAS UPPER SURFACE DELAMINATION<[01] FWD FLOOR PANEL 221EF WITH UPPER SURFACE DELAMINATION WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] JOB COMPLETE.SDR SWAA2024072403556Floor Panel · delaminatedFWD FLOOR PANEL 231AF HAS UPPER SURFACE DELAMINATION<[01] DUE TO THE EXTENT OF DAMAGE; REPLACED FWD FLOOR PANEL 231AF IAW SRM 51-10-02-0G-0 PARA 9 AND AIPC 53-21-00-50D ITEM 365.;[02] VERIFIED JOB COMPLETESDR SWAA2024072403558Floor Panel · delaminatedAFT FLOOR PANEL 242CF HAS UPPER SURFACE DELAMINATION<[01] CORRECTION: FLOOR PANEL SHOULD BE 242VF.<BR>PANEL TO BE REPAIRED ON FAULT #TTG8Q00U3266;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024072403566Floor Panel · delaminatedAFT FLOOR PANEL 241AAF HAS UPPER SURFACE DELAMINATION<[01] DUE TO EXTENT OF THE DAMAGE FABRICATED NEW 241AAF FLOOR PANEL IAW SRM 53-00-50-2R-0.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2024072407730Floor Panel · crackedCOCKPIT PANEL 211B IS CRACKED<[01] RECEIVED REPLACEMENT COCKPIT PANEL 211B <BR>(BRANT NEW); WILL BE INSTALLED ON CUST SYSTEM ID: TTG8Q00T9E95.<BR>MAINT REF SRM 51-10-02-0G-0 STEP 9.;[02] RECEIVED REPLACEMENT COCKPIT PANEL 211B<BR>(BRANT NEW); WILL BE INSTALLEDSDR SWAA2024072303545Floor Panel · pulledFLOOR PANEL 231MF UPPER SKIN HAS AREAS OF PULED STRANDS.<[01] FLOOR PANEL 231MF WITH UPPER SKIN HAS AREAS OF PULLED STRANDS WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPLETE.SDR SWAA2024072303553Floor Panel · delaminatedFWD FLOOR PANEL 222DF HAS UPPER SURFACE DELAMINATION<[01] UPPER SURFACE DELAMINATION ON FWD FLOOR PANEL 222DF WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPLETE.SDR SWAA2024072303554Floor Panel · delaminatedFWD FLOOR PANEL 222CF HAS UPPER SURFACE DELAMINATION<[01] REPAIRED DAMAGED UPPER SURFACE ON FWD FLOOR PANEL 222CF IAW SRM 53-00-50-2R-1.;[02] VERIFIED COMPLETESDR SWAA2024072303559Floor Panel · delaminatedAFT FLOOR PANEL 242VF HAS UPPER SURFACE DELAMINATION<[01] AFT FLOOR PANEL 242VF UPPER SURFACE DAMAGE HAS BEEN REPAIRED IAW SRM 53-00-50-2R-1 AND BOEING DWG: 147A5810 ID:0350.<BR><BR>ATTACHED CURE SHEET TO THIS FAULT.;[02] VERIFIED COMPLETESDR SWAA2024072303565Floor Panel · delaminatedAFT FLOOR PANEL 242UF HAS UPPER SURFACE DELAMINATION<[01] AFT FLOOR PANEL 242UF; WITH UPPER SURFACE DELAMINATION; WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] VERIFIED CORRECTIVE ACTION ITEMS; CARD COMPLETE.SDR SWAA2024072303570Floor Panel · delaminatedAFT FLOOR PANEL 241XF HAS UPPER SURFACE DELAMINATION<[01] AFT FLOOR PANEL 241XF UPPER SURFACE DELAMINATION WAS REPAIRED IAW SRM 53-00-50-2R-1.;[02] JOB COMPOLETE.SDR SWAA2024072303563Skin · crackedDURING HFEC INSPECTION OF LH HORIZONTAL STABILIZER LWR SKIN; CRACK FOUND AT STA 193.90 AT 18' FROM FWD EDGE. L: 0.9' MARKED.<[01] VERIFIED STEPS 3 COMPLETE.;[02] REMOVED THE DAMAGE PART OF LH HORIZ. STAB SKIN ON STAB STA 193.18' AND INSTALLED REPAIR PARTS IAW SDR SWAA2024072403312Panel · debondedDISBONDS NOTED ON INNER SURFACE OF PANEL 193AR<[01] REPAIRED DISBONDS ON INNER SURFACE OF PANEL 193AR IAW SRM 51-70-05-2R-2 AND SRM 51-70-05-2R-11;[02] VERIFIED
Back to N252WN