N254NV
Service difficulty reports · 22
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N254NV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N254NV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WX0A2026050432804Epsu · failed(AIRCRAFT NOT GROUNDED) DURING WEEKLY FOUND EPSU (11WL) EMER L MESSAGE. REMOVED AND REPLACED EPSU BATTERY WITH REPAIRED BATTERY IAW AMM 33-51-38-000/400-002-A. OPS CHECK GOODSDR WX0A2026040832780Epsu · faulted(AIRCRAFT NOT GROUNDED) EPSU(13WL) AFT L FAULT / REPLACED EPSU BATTERY AT 13WL IAW AMM 33-51-38-000/400-002-A. OPS CHECK GOOD."SDR WX0A2026010732696Battery · no test(AIRCRAFT GROUNDED) EPSU BATTERY 10WL FAILED EPSU BATTERY CAPACITY TEST. R & R EPSU BATTERY 10WL IAW AMM 33-51-38-000-002-A / 400-002-A"SDR WX0A2025081532543Battery · no test(AIRCRAFT NOT GROUNDED) FAS 5 FLASHLIGHT NOT BLINKING / REPLACED F/A 5 FLASHLIGHT BATTERY. OPS CHECK GOOD AT THIS TIME. THIS CLEARS MDDR 217954 MEL 25-60-08-A. INOP PLACARDS REMOVED. MX ACTION REVERSED.SDR WX0A2025041832389Intake · contaminated(AIRCRAFT GROUNDED) DURING DECENT THROUGH 15,000 FEET, DIRTY SOCK ODOR BECAME APPARENT IN THE FLIGHT DECK. FA/S IN FWD AND AFT ALSO SMELLED TH EODOR. PERFORMED ELIMINATION OF ODOR/FUMES IN FLIGHT DECK/CABIN QRH PROCEDURE. WITH PACK 1 OFF, ODOR DISSIPATED BUSDR WX0A2025041432384Smoke Detector · false activation(AIRCRAFT NOT GROUNDED) IN FLIGHT GOT ECAM SMOKE LAV SMOKE FOR RIGHT AFT LAV NO SIGN OF SMOKE FOUND. / PERFORMED LAV SMOKE DETECTOR TEXT REF AMM 26-17-00-710-001-A. TEST OK."SDR WX0A2025031432352Flashlight · inoperative(AIRCRAFT NOT GROUNDED) FA2 FLASHLIGHT INOP / REMOVED AND INSTALLED NEW BATTERY IN FA2 EMERGENCY FLASHLIGHT IAW LOPA. OPS CHECK GOOD."SDR WX0A2025020532299Battery · inoperative(AIRCRAFT GROUNDED) FORWARD FA FLASHLIGHT NOT WORKING. / REMOVED AND REPLACED BATTERY IN LEAD FA FLASHLIGHT IAW CMM 25-60-02. OPS CHECK GOOD. THIS CLEARS MEL 25-60-08B MDDR# 206869. PLACARDS REMOVED."SDR WX0A2024090632167Megaphone · no test(AIRCRAFT NOT GROUNDED) FA REPORTS MEGAPHONE IS NOT TESTING CORRECTLY / REPLACED MEGAPHONE BATTERIES IAW AMM 25-65-51-920-001-A. OPS CHECK GOOD."SDR WX0A2023121131918Megaphone · unknownAFT MEGAPHONE INOP / REMOVE & REPLACED AFT MEGAPHONE REF S.I.P. AND AMM 25-65-51-710-002. OPS CHECK GOOD."SDR EE4Y2023091118385Skin Panel · corrodedDURING THE ALLEGIANT WORD CARD ZL-540-01-1-001 ,FOUND AT LH BOTTOM WING SKIN AREA AROUND MANHOLE 540JB WITH CORROSION.DUE REWORKED AREA WAS FOUND OUT LIMITS IAW A320 SRM TASK 57-21-11-283-003 PARAG.2A FLOWCHART FIG 001 (SHEET 1 AND 2). AIRBUS WAS CONTACTED RSDR EE4Y2023090618359Door · dentedDURING THE ALLEGIANT WORD CARD ZL-831-04-1-001 , IT WAS FOUND A DENT ON FWD LH PASS DOOR AFT LOWER CORNER.EVALUATED DENTED AREA AND FOUND OUT OF ALLOWABLE DAMAGE LIMITS IAW A320 SRM TASK 52-10-00-283-002 PARAG 2.A.1 FIGURE 2 SHEET 2.AIRBUS WAS CONTACTED REQUESSDR WX0A2023072431801Epsu · unknownWHILE PERFORMING CABIN EMERG LIGHTING CHECK EPSU BATTERIES FAILED AT LOCATIONS 10WL, 11WL, 12WL AND 13WL. REQUIRE REPLACEMENT. / REMOVED AND REPLACED EPSU BATTERIES AT LOCATIONS 10WL, 11WL, 12WL AND 13WL, OPS CHECK GOOD IAW AMM 33-51-38-000-002-A AND AMM 33-51SDR WX0A2022110974311Epsu · noneEPSU 13WL FAILED TEST / REMOVED AND REPLACED THE EPSU 13WL BATTERY. REF AMM 33-51-38-000-002-A AND AMM 33-51-38-400-002-A. NO FURTHER DISCREPANCIES FOUND."SDR WX0A2022091674243Megaphone · noneDURING EMERGENCY EQUIPMENT CHECK, FOUND AFT MEGAPHONE INSPECTION DUE AT END OF MONTH FOR BATTERY REPLACEMENT. DURING BATTERY REPLACEMENT FOUND CURRENT BATTERIES LEAKING INTERNALLY INSIDE MEGAPHONE CAUSING CORROSION. / REMOVED AND REPLACED AFT MEGAPHONE IAW AMMSDR WX0A2022050674080Epsu · none12WL EPSU BATTERY FAILED EPSU TEST / REMOVED AND REPLACED 12WL EPSU BATTERY IAW AMM 33-51-38 PB 401. OPS CHECK GOOD."SDR WX0A2022020973987Epsu · noneWHILE COMPLETING TC-335100-03-001, EMERGENCY POWER SUPPLY UNIT AT FIN-12WL FAILED DURING TEST. / REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT LOCATED AT FIN-12WL IAW AMM 33-51-38, OPS CHECK GOOD."SDR WX0A2022020973989Megaphone · noneFORWARD MEGAPHONE INOP / REMOVED AND REPLACED FWD MEGAPHONE IAW AMM 25-65-51. OPS CHECK GOOD. A/C OK FOR SERVICE."SDR WX0A2021012573630Power Supply · faultedOPERATIONAL TEST OF THE EMERGENCY LIGHTS FAULTS. EPSU (10WL)FWD L AND EPSU (13WL) AFT L/DEU (300RH7). ACCOMPLISHED T/S AS PER A320 TSM 33-51-00-810-836-A. FOUND FAULTY LIGHTS CIRCUIT ON AFT RT SLIDE/RAFT, AS PER TSM. REMOVED AND REPLACED EPSU (13WL), REF AMSDR WX0A2021012273631Power Supply · inoperativeSEE NR00728622 FOR ORIGINAL DISCREPANCY. EPSU 10WL INOPERABLE. REMOVED AND REPLACED FORWARD EPSU 10WL, PER A320 AMM 33-51-38 PB 401.SDR WX0A2021012273630Power Supply · inoperativeSEE NR00728622 FOR ORIGINAL WRITE UP. EPSU 13WL INOPERABLE. REMOVED AND REPLACED EPSU 13WL, PER A320 AMM 33-51-38. OPERATIONS CHECK BAD, ITEM REMAINS OPEN.SDR WX0A2020091173568Epsu · failedPERFORMED EPSU SYS TEST, RECEIVED MESSAGE "BAT/EPSU ( 11WL ) EMER L". REMOVED AND REPLACED EPSU BATTERY, IAW AMM 33-51-38. OPS CHECK GOOD