N2645U
Service difficulty reports · 25
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2645U' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N2645U' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026052016407Light · damagedTHE FLOOR PROXIMITY LIGHT DAMAGE ON ROW 53 RH & ROW 43 LH. REPLACED LIGHT ASSY AND OPERATION CHECK OK.SDR CALA2026052016405Cradle · faultyEMERGENCY EQUIPMENT PLACARD, GENERAL PROCEDURE. FOUND CAPT SIDE PUSH-TO-TEST BUTTON NO LIGHT SHOW AT ALL. R & R FLASHLIGHT BRACKET ASSY, FUNCTION CHECKED GOOD, CONDITION OK. FLASHLIGHT FUNCTION CHECKED OK IAW AMM 25-64-01.SDR CALA2025101610188Controller · faultedBLEED FAMV R EICAS STATUS RIGHT ENGINE BLEED FAN AIR MODULATING VALVE (FAMV) FAILED OPEN O R CLOSED, OR RT AIR SUPPLY AND CABIN PRESSURE CONTROLLER FAILURE. CMC MSG 3610325, AIR SUPPLY & CABIN PRES SURE CONTROLLER (R) PRESENT LEG FAULTS AND EXISTING FAULTS. SDR CALA2025082508093Light · looseEMERGENCY EXIT LIGHTS LOOSE AT 47D RESECURED EMERGENCY LIGHT AT SEAT 47D REF AMM 33-51-01.SDR CALA2025042404194Battery · dischargedDR R2 M33098 EMER LT BATTERY PACK CAPACITY CHECK FAILED. DR R2 M33098 EMER LT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM33-26-00.SDR CALA2025042404191Battery · dischargedSUPPORT TASK - OFAR M33143 EMER LT BATTERY PACK CAPACITY CHECK FAILED. EMER LT BATTERY PACK REPLACED AND TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2025042404190Battery · dischargedSUPPORT TASK - DR R3 M33305 EMER LT BATT PACK CAPACITY CHECK FAILED. REPLACED EMER LIGHT BATTERY AT DR R3 M33305 AND TESTED NORMAL AS PER AMM33-51-06.SDR CALA2025022402434Skin · damagedSKIN WAVINESS - EXAMINATION (AT THE STATIC PORTS) SKIN WAVINESS EXAMINATION - L/H FUSELAGE FOUND DENT BETWEEN LEFT AND RIGHT STATIC PORTS.MEASURED DENT JUST FWD OF AIRCRAFT LEFT- AFT STATIC PORT AT STATION BS 764 AND WL139. DENT MEASURED 1.625 " X 1.50" ; DEPTSDR CALA2025021802362Lens · inoperativeAISLE EMERGENCY LT INOP AT SEAT 42D,48D & 53G. RPL'D LAMP & LENS THEN OPN CKD OK.PARTS USED: 26-3321-3-0054,QTY :1SDR CALA2024122601657Proximity Sensor · faultedEICAS MSG DOOR E/E ACESS CLEANED E&E ACCESS DOOR PROX SENSOR, OPENED AND CLOSED DOOR SEVERAL TIMES WITH NORMAL EICAS INDICATIONS DURING EACH CYCLE. DOOR AND TRACKS IN GOOD OPERATING CONDITION AND WIRING IS IN GOOD CONDITION, REF FIM 52-48 TASK 805.SDR CALA2024120603028Gcu · failedPOWER DROPPED OFF LINE PRIOR TO PUSHBACK. FLAGGED SDR FOR LOSS OF ELEC POWER REPLACED APU GENERATOR CONTROL UNIT REF AMM TASK 24-22-02-400-801. TESTS ARE OK REF AMM TASK 24-22-02-710-802. VERIFIED RIGHT BUS MAINTAINS POWER ON APU GENERATOR AND EXTERNAL POWERSDR CALA2024120501405Gcu · odorPOWER DROPPED OFFLINE PRIOR TO PUSHBACK. FLAGGED SDR FOR LOSS OF ELEC POWER REPLACED APU GENERATOR CONTROL UNIT REF AMM TASK 24-22-02-400-801. TESTS ARE OK REF AMM TASK 24-22-02-710-802. VERIFIED RIGHT BUS MAINTAINS POWER ON APU GENERATOR AND EXTERNAL POWER.SDR CALA2024040400976Access Panel · missingPDA 1 PANEL 196CR (GROUND AIR CONDITIONING PANEL) DELAMINATED AND 12X37 AREA BROKE OFF. REF IPC 53-96-51 ITEM 370. REF TO LOGPAGE 7519283.SDR CALA2023100602983Light · crackedSEAT 22G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY FOUND CRACK. SEAT 22G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY REPLACED AND OPER ATIONAL TEST PERFORMED AS PER AMM33-51-05, FOUND SATISFACTORY.SDR CALA2023100602981Light · crackedSEAT 53G AND 54G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY FOUND CRACK. SEAT 53G AND 54G SEAT MOUNTED EMERGENCY LIGHT ASSEMBLY REPLACED AS PER CMM25-21-53 REV 1 INSTALLATION TEST PERFOR MED AND FOUND SATISFACTORY.SDR CALA2023100602979Charger · damagedDOOR 1 RIGHT (M33094) EPSU CHARGER ASSEMBLY TEST BUTTON FOUND MISSING. DOOR 1 RIGHT EPSU CHARGER ASSEMBLY REPLACED AS PER AMM33-51-06-9 REV 98 DATED 05 MAY 2023. INSTALLATION TEST CARRIED OUT AS PER AMM33-51-06-960-803 REV 99 DATED 05 SEP 2023 FOUND WORKING SASDR CALA2023100602977Housing · crackedM7 GALLEY RH FWD PROXIMITY LIGHT ASSY FOUND HOUSING CRACKED. M7 GALLEY RH FLOOR PROXIMITY LIGHT ASSY REPLACED AND OPERATIONAL CHECK FOUND SATISFACTORY AS PER AMM33-51-05. WORK ACCOMPLISHED BY V943554SDR CALA2023100602975Charger · damagedDOOR 4 LEFT(M33406)EPSU CHARGER ASSEMBLY TEST BUTTON FOUND MISSING. EPSU CHARGER ASSEMBLY REPLACED AS PER AMM33-51-06-960-803 REV 98 INSTALLATION TEST CARRIED OUT AS PER AMM33-51-06-960-803 REV 99 DATED 05 SEP 2023, FOUND WORKING SATISFACTORY.SDR CALA2023100602985Lamp · inoperativeFOUND FOLLOWING CABIN SEATS PEEPS LAMP (1 OFF EACH)BLOWN AT 34D, 42D, 41G, 40G, 38G, 32G, 22G, 46G, 48G, 49G, 50G, 53G, 54G, 56G, 58G, 57D, 54D, 49D AND 47D THE FOLLOWING SEATS PEEPLS LIGHT LAMP REPLACED AND OPERATION TES ALL LIGHTS WORKING GOOD. T CARRIED OUTSDR CALA2023091802811Battery · noneEMERGENCY FLASH LIGHT BATTERIES FOUND WITH SERVICE LIFE EXPIRING. EMERGENCY FLASHLIGHT BATTERIES 14 EACH REPLACED IAW AMM 25-60-07 BY MECH L3885. NRC 38593834SDR CALA2023071902278Oven · inoperativeSMOKE FROM OVEN 410. OVEN TURNED OFF CB PULLE D. OVEN SMOKE DUE TO SPILLED FOOD . PLACED ON MEL. COMP. WITH MEL OVEN INOPED. NOC DESK: 777 NAME: DOUG DATE: 17-JUL-23- MID GALLEY OVEN 410 - NEF 2520AV PLEASE DO NOT USE TILL OVEN IS REPLACED. RTBL FOR SMOLE ISDR CALA2023070702182Skin · damagedRAMP REPORTED DAMAGE (GAUGE) ABOUT 5" FWD FOR THE FWD CARGO AT THE LAP SEEM. CORRECTION, DAMAGE IS 5 FEET FORWORD OF THE FORWARD CARGO DOOR. DAMAGE IS 66.5" FWD OF FWD CARGO DOOR CUTOUT BETWEEN STATIONS REMOVED FASTENERS ON SKIN LAP AND STRINGER JUST BELOW. CUSDR CALA2022042901107Smoke Detector · warning messageSMOKE DETECTED MSG DISPLAYED LEFT HAND CACP DR 5L RESET ACFT POWER MSG CLEARED.SDR CALA2021060200781Smoke Detector · false indicationMOMENTARY SMOKE LAVATORY EICAS. NO SMOKE PRESENT. LAV 4R. PERFORMED LAVATORY SMOKE DETECTION - SMOKE TEST IAW AMM TASK 26-13-00-730-801, NO FAULTS NOTED. 4R LAV SMOKE DET SYS OK FOR SVC.SDR CALA2019091401543Screen · dirtyCREW REPORTS AIRFLOW SUPPLY LIGHT ILLUMINATED IN CREW REST. ALSO NO AIRFLOW IN FLT DECK. ATTEMPTED SEVERAL RESETS WITH PACK RESET SW. AND ALSO ATTEMPTED TO HEAT PACK UP WITH TRIM AIR OFF TO TRY TO CLEAR POSSIBLE ICE ACCUMULATION ALL NO HELP. REFERENCE TO LOG 3