N267WN
Service difficulty reports · 303
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N267WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N267WN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022030222010Track · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 463 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030222011Track · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 470 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030222005None · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 430 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030222006Track · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 437 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030222007Track · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 443 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030222002Track · elongated#3 SEAT TRACK I/B UPPER FLANGE FLOOR BOARD HOLE ELONGATED STA 422 / REMOVED AND INSTALLED NEW SEAT TRACK FROM STA 370 TO 480 PER SRM 51-40-02.SDR SWAA2022030221987Bracket · crackedFWD CARGO STA. 500D; BRACKET AT STRINGER 19L CRACKED. (MARKED) / FWD CARGO STA. 500D, INSTALLED REPLACEMENT BRACKET AT STRINGER 19L PER EA # 1-753-34162.SDR SWAA2022030221988Bracket · crackedFWD CARGO STA. 500D; BRACKET AT STRINGER 19R CRACKED. (MARKED) / FWD CARGO STA. 500D, INSTALLED REPLACEMENT BRACKET AT STRINGER 19R PER EA # 1-753-34162.SDR SWAA2022030221972Angle · corrodedFWD CARGO STA. 420-440; RIGHT TRANSITION ANGLE HAS CORROSION AROUND NUT-PLATE HOLES. / REMOVED AND REPLACED TRANSITION ANGLE (MPN 143A8126U21) PER SRM 51-40-02. SEE INDIVIDUAL SIGN OFFS FOR PROGRESSION.SDR SWAA2019020429123Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 787, STR 11R. R&R CLIP PER SRM.SDR SWAA2019020429121Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 807, STR 11R. R&R CLIP PER SRM.SDR SWAA2019020429120Stringer Clip · crackedSTRINGER CLIP CRACKED AT BS 827, STR 11R. R&R CLIP PER SRM.SDR SWAA2019013129033Strap · crackedFLOOR SUPPORT STRAP CRACKED AT BS 540, RBL 26. R&R STRAP PER SRM.SDR SWAA2019012928995Stringer · crackedRT WING INBOARD FIXED LEADING EDGE SKIN SUPPORT STRINGER CRACKED. R&R STRINGER PER SRM.SDR SWAA2022022521965Intercostal · crackedPASSENGER CABIN FLOOR STRUCTURE; AREA ABOVE WING BOX CENTER SECTION; BS 540; BL 0 TO LBL 2; INTERCOSTAL CRACKED THROUGH LOWER ANGLE. / REMOVED AND REPLACED WITH NEW INTERCOSTAL PER SRM 51-40-02SDR SWAA2019020829425Threshold · corrodedAFT CARGO THRESHOLD WEB CORRODED. R&R WEB PER SRM.SDR SWAA2022030121909Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 727A-727B. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROMSDR SWAA2022030121910Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 727B-727C. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROMSDR SWAA2022030121911Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 727C-727D. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROMSDR SWAA2022030121912Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 727D-727E. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROMSDR SWAA2022030121913Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 727E-747. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROM SDR SWAA2022030121914Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 747-767. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED L/H TRANSITION ANGLE FROM STA.727 TO 847 ; PART # 147A7501-17 ; LOCATED AND DRILLED SDR SWAA2022030121915Angle · corrodedAFT CARGO L/H TRANSITION ANGLE HAS CORROSION STA 767-787. / REMOVED CORR. L/H TRANSITION ANGLE PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM.53-60-51-1A1 ; REMOVED AND REPLACED PART # 147A7501-17 ; AND Z ANGLE SPLICE ; TRANSITION ANGLE FROM SSDR SWAA2022030121920Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 727D-727E. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 PER SRM. 51-40-02SDR SWAA2022030121923Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 767-787. / REMOVED CORR. AFT CARGO R/H TRANSITION ANGLE STA. 767-787 . PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OF LIMITS PER SRM. 53-00-53-1A-2 ; REMOVED AND REPLACED PART #146A8127U12 PER SRM. 51-40-02SDR SWAA2022030121927Panel · crackedPANEL 343CB AFT BULLNOSE HAS SEVERAL CRACKS (MARKED) / REMOVED AND REPLACED R/H HORIZONTAL STAB BALANCE BAY PANEL 343CB PER AMM 27-31-41. PANEL TO BE INSTALLED ON JPANEL-340-CLOSE TASK CARD.SDR SWAA2022030121943Beam · corrodedCORROSION IN AND AROUND FASTENER HOLE FOR RIGHT AFT GIRT BAR ATTACH BRACKET. STA. 986.5 RBL 43 / REMOVED CORROSION TO UPPER FWD FLANGE OF 986.5 FLOOR BEAM AT GIRT BAR ATTACH DOME NUT PER EA 1-A53-8241 R2. MECHANICALLY MEASURED .130' MATERIAL REMAINING; FILLED SDR SWAA2022030121937Strip · corrodedAFT CARGO N/P STRIP AT BS887 HAS CORROSION IN AND N/P HOLES BL0-RBL19. / REMOVED AND INSTALLED NEW N/P STRIP PER SRM 51-40-02SDR SWAA2022030121921Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 727E-747. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 ; INSTALLED PER SRM. SDR SWAA2022030121922Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 747-767. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 ; INSTALLED PER SRM. 5SDR SWAA2022030121919Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 727C-727D. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 PER SRM. 51-40-02SDR SWAA2022030121917Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 727B-727C. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 PER SRM. 51-40-02SDR SWAA2022030121916Angle · corrodedAFT CARGO R/H TRANSITION ANGLE HAS CORROSION STA 727A-727B. / REMOVED CORR. PER SRM. 51-10-02 ; MATERIAL FOUND TO BE OUT OFF LIMITS PER SRM. 53-60-51-1A-1 ; REMOVED AND REPLACED R/H TRANSITION ANGLE FROM STA.727 TO 767 ; PART # 146A7500-16 PER SRM. 51-40-02SDR SWAA2019020829424Bracket · corrodedAFT CARGO BRACKET CRACKED AT BS 865 LBL 10 ON VERTICAL POST. R&R BRACKET IAW SRM.SDR SWAA2022030121897Balance Weight · corrodedSUPPLEMENTAL INFORMATION: RUDDER WEIGHT CORRODED / ANSWERED CORROSION QUESTIONS. INSTALLED NEW SERVICEABLE RUDDER BALANCE ARM WEIGHT PER SRM 51-60-07-0G-0 PARAGRAPH 5. (6) (C) TO 5. (6) (C) D) RUDDER BALANCE ADJUST WEIGHT INSTALLATION ONLY WITH REFERENCE TO CMSDR SWAA2022030121898Skin · delaminatedRUDDER SKIN HAS SMALL AREA OF DELAMINATION ON RIGHT SIDE APPROXIMATELY 80 INCHES FROM TOP / REPAIRED DAMAGED AREA PER SRM 51-70-05-2R-1. RESTORED FINISH PER AMM 51-21-73; AND CALCULATED NEW MOMENT IAW SRM 51-60-07-0G-0. NEW MOMENT IS 532.46.MARKED RUDDER IDENTSDR SWAA2019020729377Attach Bracket · corrodedLT AFT GIRT BAR ATTACH BRACKET CORRODED AROUND FASTENER HOLE AT BS 987, LBL 45. R&R T-CAP PER SRM AND EA.SDR SWAA2019020629351Block · corrodedFLOOR AROUND GALLEY ATTACK BLOCK CORRODED AT BS 1016, RBL 8. REPAIRED BLOCK PER EA.SDR SWAA2019020629350Web · corrodedFLOOR WEB STRAP CORRODED AT BS 1028, RBL 8. REPAIRED WEB PER EA.SDR SWAA2019020629348Web · corrodedFLOOR WEB CORRODED AT BS 1016, RBL 36. REPAIRED WEB PER EA.SDR SWAA2019020629347Strap · corrodedFLOORBEAM STRAP CORRODED AT BS 1016, RBL 3. REPAIRED STRAP PER EA.SDR SWAA2019020429118Angle · corrodedLT SIDE Z ANGLE SURFACE CORRODED. R&R Z ANGLE PER SRM.SDR SWAA2019013029020Angle · corrodedRT Z ANGLE SURFACE CORRODED. R&R Z ANGLE PER SRM.SDR SWAA2019012828912Intercostal · crackedFLOOR INTERCOSTAL CRACKED BETWEEN BS 312 TO BS 328, RBL 31. R&R INTERCOSTAL PER SRM.SDR SWAA2019012828911Intercostal · crackedFLOOR INTERCOSTAL CRACKED BETWEEN BS 294.5 TO BS 312, RBL 15. R&R INTERCOSTAL PER SRM.SDR SWAA2019012828910Angle · crackedANGLE BRACKET CRACKED AT BS. 294.5, FORWARD DOOR FRAME, FLOOR LEVEL, FORWARD OF FRAME, OUTBOARD OF ZEE ANGLE. R&R ANGLE PER SRM.SDR SWAA2019012428876Intercostal · crackedFLOOR INTERCOSTAL CRACKED BETWEEN BS 328 TO BS 344, LBL 45. R&R INTERCOSTAL PER SRM.SDR SWAA2022030121894Stiffener · crackedSUPPLEMENTAL INFORMATION: ON THE RIGHT HAND HORIZONTAL STABILIZER; THE INTERNAL RIB AT STAB STATION 120.30 HAS A CRACKED STIFFENER APPROXIMATELY 27.5 INCHES FROM THE FRONT SPAR. / RIGHT HAND HORIZONTAL STABILIZER RIB CRACKED AT STAB STA. 120.3 REPAIRED PER SRMSDR SWAA2022030121893Stiffener · crackedSUPPLEMENTAL INFORMATION: ON THE RIGHT HAND HORIZONTAL STABILIZER; THE INTERNAL RIB AT STAB STATION 120.30 HAS A CRACKED STIFFENER APPROXIMATELY 19 INCHES FROM THE FRONT SPAR. / ACCOMPLISHED PERMANENT REPAIR PER SRM 55-10-09-2R-4 REPAIR 4.SDR SWAA2022030121843Bracket · crackedRT WING PANEL SUPPORT BRACKET UNDER FWD INBD CORNER OF PANEL 651AT CRACKED [MARKED]. / REMOVED AND REPLACED SUPPORT BRACKET UNDER FWD INBD CORNER OF PANEL 651AT AS PER SRM. 51-40-02.