N271NN
Service difficulty reports · 19
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N271NN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N271NN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20260930001Battery Pack · inoperativeEMERGENCY LIGHT OVER ROW 16/17 NOT WORKING. R & R POWER UNIT 3 BATTERY PACK IAW AMM 33-50-01. OPS CHKD OK.SDR SIMA20260930002Light · inoperativeEMERGENCY LIGHT IN CABIN NOT WORKING. EMERGENCY LIGHTS OVER ROW 2 NOT WORKING. PERFORMED OPC OF EMER LIGHT SYS IAW AMM 33-50-00. OPC OK. NO FAULT FOUND.SDR SIMA20260824006Battery Pack · inoperativeCOCKPIT EMERGENCY LIGHT WILL NOT ILLUMINATE. SEE AML PAGE NUMBER 103302168 FOR ORIGINAL WRITE UP. RAR FWD RH EMERGENCY LIGHT POWER UNIT IAW AMM TASK 33-50-01. OPS CHECK GOOD. MEL RESTORED.SDR SIMA20260102003Battery · inoperativeCEILING PANEL EMERGENCY LIGHT AT ROWS 20, 21 INOPERATIVE. R & R CEILING PANEL LIGHT AND #4 EMERGENCY BATTERY IAW ERJ 175 AMM 33-50-13 AND 33-50-01. OPS CHKD GOOD.SDR SIMA20251013004Light · inoperativePHOTOLUMINESCENT STRIP LIGHT INOP AT ROW 4A. RAR PHOTOLUMINESCENT STRIP LIGHT AT ROW 4A IAW ERJ-175 AMM 33-50-21/400. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20251013001Light · inoperativePHOTOLUMINESCENT STRIP LIGHT INOP AT ROW 1DF. R & R PHOTOLUMINESCENT STRIP LIGHT AT ROW 1DF IAW ERJ-175 AMM 33-50-21/400. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20251013002Light · inoperativePHOTOLUMINESCENT STRIP LIGHT INOP AT ROW 21AC. R & R PHOTOLUMINESCENT STRIP LIGHT AT ROW 21AC IAW ERJ-175 AMM 33-50-21/400. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20251013003Light · inoperativePASSENGER ENTRYWAY PHOTOLUMINESCENT STRIP LIGHT INOP. RAR PASSENGER ENTRYWAY PHOTOLUMINESCENT STRIP LIGHT IAW ERJ-175 AMM 33-50-21/400. OPS CHECK GOOD. NO FURTHER DEFECTS NOTED.SDR SIMA20250404001Priority Valve · leakingHYD PRESSURE TOTAL LOSS OF HYD2 FLUID IN FLIGHT. DECLARED EMERGENCY TOWED TO GATE PERFORMED INSPECTION OF HYD SYSTEMS IAW AMM 05-50-23 FOUND OUTLET PORT OF BOOTSTRAP PRIORITY VALVE N2 HYD SYSTEM LEAKING, RAR DAMAGED ORING ON THE OUTLET PORT OF N2 HYD SYSTEM BSDR SIMA20241006001Seat Track · corrodedSEAT TRACK CORRODED BETWEEN FRM 84-85 AND Y+9. (LEVEL 2 CORROSION) BLENDED CORROSION FROM RH SEAT TRACK AT FR 74-85 IAW EMB 175 SRM 51-10-03 . AFT RH SEAT TRACK REQUIRES REPLACEMENT. FABRICATED REPAIR DOUBLERS, CUT SEAT TRACK BETWEEN FRM 81 AND 82 FOR SPLICE RSDR SIMA20240919003Seat Track · corrodedSEAT TRACK CORRODED BETWEEN FR 84-85 Y-9. (MAJOR REPAIR) APPLIED EWIS PROTECTION BELOW SEAT TRACK BETWEEN FRAMES 74-85. BLENDED CORROSION FROM LH SEAT TRACK AT FR 74-85 IAW EMB 175 SRM 51-10-03. AFT LH SEAT TRACK REQUIRES REPLACEMENT IAW EMB 175 SRM 53-23-10/ASDR SIMA20240919002Seat Track · corrodedSEAT TRACK CORRODED BETWEEN FRM 84 AND 85 Y+9. (MAJOR REPAIR) BLENDED CORROSION FROM RH SEAT TRACK AT FR 74-85 IAW EMB 175 SRM 51-10-03. AFT RH SEAT TRACK REQUIRES REPLACEMENT. FABRICATED REPAIR DOUBLERS , CUT SEAT TRACK BETWEEN FRM 81 AND 82 FOR SPLICE REPAIRSDR SIMA2024100719001Seat Track · corrodedSEAT TRACK CORRODED BETWEEN FR 84-85 AND Y-9 (LEVEL 2 CORROSION) APPLIED EWIS PROTECTION BELOW SEAT TRACK BETWEEN FRAMES 74-85.BLENDED CORROSION FROM RH SEAT TRACK AT FR 74-85 IAW EMB 175 SRM 51-10-03 . AFT LH SEAT TRACK REQUIRES REPLACEMENT IAW EMB 175 SRM 53SDR SIMA20230909002Unknown · unknownRAMP REPORTS DAMAGE UNDER AFT SERVICE DOOR. (MAJOR REPAIR)-C/A-C/W INSTALLATION OF DOUBLER, TRIPLER, FILLER APPLIED FILLET SEALANT AND RESTORED ORIGINAL FINISH IAW ERS-EJ-53MR-4858SDR SIMA20220518006Skin Panel · gougedDENT/GOUGE ON R/H SIDE AFT FUSELAGE BETWEEN FRAMES 80-82 STRINGERS 21L-22L. (MAJOR REPAIR)-C/A-C/W PERMANENT REPAIR IAW ERS EJ-53MR-4524SDR SIMA202006054002Power Unit · inoperativeNR 2 EMERGENCY LIGHT POWER UNIT INOP. REMOVED AND REPLACED NR 2 EMERGENCY LIGHT POWER UNIT PER AMM 25-22-07. OPC GOOD.SDR SIMA202003252003Warning System · false activationBRK CONTROL FAULT-C/A-ACCOMPLISHED TROUBLESHOOTING IAW FIM TASK 32-41-00. FAULT FOUND TO BE IN A TRANSITORY CONDITION. NO FURTHER DEFECTS NOTED. FAULT REMOVED.SDR SIMA201910298002Battery Pack · inoperativeCABIN CEILING EMERGENCY LIGHT AT ROW 2 INOP-C/A-REMOVED AND REPLACED EMERGENCY LIGHT POWER UNIT BATTERY ABOVE FWD PAX DOOR IAW AMM 33-50-01. OPS CHECK GOOD.SDR SIMA20190727002Battery · dischargedEMERGENCY LIGHTS INOP IN GALLEY #1. C/A-RAR EMERGENCY BATTERY IN GALLEY #1 IAW AMM 33-50-01 OPS WAS GOOD.
Back to N271NN