N272AY
Service difficulty reports · 320
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N272AY' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N272AY' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201611239016Floor Support · corrodedFLOOR SUPPORT CORRODED. REPLACED THE FLOOR SUPPORT IAW SRM 51-41-11, AND SRM 51-44-11.SDR AALA201611239015Shim · corrodedDOOR SILL SHIM CORRODED. REPLACED THE SHIM IAW SRM 51-41-11.SDR AALA201610319002Oven · odorAIRCRAFT WAS NOT GROUNDED. OVEN NR 1 HAS STRONG ELEC SMELL MAYBE A BAD HEATING COIL. MAINTENANCE REPLACED THE NR 1 OVEN PER AMM 25-35-19.SDR AALA201610289009Oven · malfunctionedNR 1 OVEN IN AFT GALLEY BECAME UNCONTROLLABLE HOT, PULLED CIRCUIT BREAKER AND HEAT SUBSIDED. MAINTENANCE REPLACED THE OVEN AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECKED IAW AMM 25-35-19.SDR AALA201610059005Battery · inoperativeDURING DAILY CHECK FOUND THE L1 DOOR EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED THE FLASHLIGHT BATTERY IAW AMM 25-60-00.SDR AALA201610029008Sign · detachedEMERGENCY EXIT SIGN FELL OFF AT 3L DOOR. INSTALLED EMERGENCY EXIT SIGN AT THE 3L DOOR.SDR AALA201607199002Girt Bar · obstructedAIRCRAFT WAS NOT GROUNDED: L1 DOOR SLIDE WILL NOT ARM. MAINTENACE REMOVED GLASS FROM THE GIRT BAR FLOOR TRACK.SDR AALA201606209009Server · defectiveAIRCRAFT WAS NOT GROUNDED. FLIGHT CREW REPORTED THAT WHILE DESCENDING THROUGH 200000 FEET, VIDEO SCREENS IN ECONOMY WERE BLINKING ON AND OFF AND F/A`S DETECTED AN ODOR RESEMBLING DIRTY SOCKS. POWER TO VIDEO SYSTEM WAS SHUTDOWN AND AN EMERGENCY WAS DECLARED. SDR AALA201606089003Bottle · low pressureAIRCRAFT WAS NOT GNDED. CIDS INDICATES DOOR 3L SLIDE BOTTLE PRESSURE LOW. SERVICED 3L DOOR ASSIST BOTTLE IAW AMM 52-10-00.SDR AALA201605069003Damper · low pressureAIRCRAFT WAS NOT GNDED. 3L DOOR DAMPER REQUIRES CHARGING. SERVICED 3L DOOR DAMPER IAW AMM 52-10-00.SDR AALA201604169001Battery · faultedAIRCRAFT WAS NOT GNDED. 4L EMER POWER SUPPLY BATTERY FAULT DURING TEST 17WL. R & R BATTERY & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-38.SDR AALA201603279001Brake · defectiveAIRCRAFT WAS NOT GNDED. AFTER TAKEOFF FOR LT PACK MAX TEMP, WHEEL 1=395, WHEEL 2= 585, WHEEL 5= 300 & WHEEL 6=485. THE BRAKES WERE COOLED, THE GEAR RETRACTED & THE FLIGHT CONTINUED. CREW REQUESTED EMER EQUIPMENT BE STANDING BY UPON ARRIVAL AS A PRECAUTIONARSDR AALA201603069001Channel · contaminatedAIRCRAFT WAS GNDED. FLIGHT ATTENDANTS REPORTED SMELLING FUMES IN AFT & MID GALLEY. MX CONFERRED WITH FLIGHT CREW & WAS ADVISED OF A SWEET & THICK ODOR. UPON INSPECTION OF ACFT, FOUND ALL ENTRY DOOR CHANNELS SATURATED WITH DE-ICING FLUID. INITIAL REPORT OF SDR AALA201602099002Cylinder · low pressureAIRCRAFT WAS NOT GNDED, L3 DOOR EMER ASSIST CYLINDER PRESS NOT IN THE GREEN ZONE, IT’S IN THE YELLOW ZONE. SERVICED CYLINDER TO GREEN ZONE IAW JC 33L00005002.SDR AALA201601179001Unknown · odorAIRCRAFT WAS GNDED. PASSENGERS AT SEAT 30 G & H REPORTED A SMELL & HAVING A HEADACHE. ACCOMPLISHED JC 33L00021001, NO ODOR NOTED. REPLACED HEPA FILTERS AS A PRECAUTIONARY ACTION. ACFT RETURNED TO SERVICE.SDR AALA201601149001Mechanism · obstructedAIRCRAFT WAS NOT GNDED. 4L DOOR WILL NOT ARM. REMOVED DEBRIS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK OF THE DOOR ARMING MECHANISM.SDR AALA201601119008Fitting · defectiveAIRCRAFT IN BASE MX. CONTROL NIT 22DH FAILS OPERATIONAL TEST. REPLACED SLIDE FITTING, ACCOMPLISHED ADJUSTMENT & OPERATIONAL CHECK IAW AMM 30-46-11-400-801D, 52-13-00-820-001 & 30-46-00-710-801D.SDR AALA201601049002Lens · brokenAIRCRAFT IN BASE MX. R3 DOOR OVERHEAD EXIT SIGN LENS IS BROKEN. R3 DOOR OVERHEAD EXIT SIGN LENS REPLACED IAW MM 33-51-16-04-01.SDR AALA201512309006Wire Harness · damagedAIRCRAFT IN BASE MX. SEAT 24HG, EMER LIGHT HARNESS DAMAGED. REPLACED EMER LIGHT HARNESS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-803-A.SDR AALA201512299006Wire Harness · damagedAIRCRAFT IN HEAVY MX. 3A EMER LIGHT HARNESS DAMAGED. REPLACED WIRE HARNESS & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-00-710-803-A.SDR AALA201508149003Bottle · low pressureON WALK THRU FOUND 3L DOOR PRESS LOW. SERVICED L3 DOOR ASSIST BOTTLE IAW AMM 52-22-00-0600-801A.SDR AALA201505269007Battery · dischargedCABIN EMER LIGHTING BATTERY CAPACITY CHECK FAILED TEST. FAULTED EPSU 1L, 1R, 2L & 3L. REPLACED THE CABIN EMER LIGHT BATTERIES AT 1L, 1R, 2L, & 3L.SDR AALA201505139003Diaphragm · rupturedDURING DAILY CHECK FOUND DOOR R4 ASSIST ACTUATOR EMPTY. REPLACED RUPTURED DIAPHRAGM ON R4 DOOR EMER OPERATION CYLINDER.SDR AALA201504149003Oven · odorAFT GALLEY ACFT RT OVEN NR 1 EXCESSIVE SMOKE. CB PULLED AS DIRECTED. R & R AFT GALLEY NR 1 OVEN.SDR USAA2015040700003Cylinder · low pressureL3 DOOR EMER OPERATION CYLINDER, PRESS BELOW GREEN BAND. SERVICED L3 DOOR EMER OPERATION CYLINDER.SDR USAA2015040700002Cylinder · low pressureR2 DOOR EMER OPERATION CYLINDER PRESS BELOW GREEN BAND. SERVICED R2 DOOR EMER OPERATIONS CYLINDER.SDR USAA2015032600001Bottle · low pressureDOOR 3L REQUIRES ASSIST BOTTLE SERVICING. SERVICED 3L DOOR ASSIST BOTTLE.SDR USAA2015022700001Hook · brokenSEATS 26G & H O2 MASKS DROPPED ON TAKEOFF. FOUND HOOK BROKEN AT 17H-G & 36 A-B. REPLACED LATCH HOOKS & REPACKED MASKS AT SEATS 26 G & H.SDR USAA2015020900003Power Supply · inoperativeDEU-1 15WL & 18WL FAIL EPSU SYS TEST. R & R EPSU ON 15WL & 18WL, R & R EPSU BATTERIES ON 15WL & 18WL.SDR USAA2015020900002Power Supply · inoperativeDEU-1 15WL FAIL EPSU SYS TEST. R & R EPSU ON 15WL, R & R EPSU BATTERIES ON 15WL.SDR USAA2015012600006Bottle · low pressure3L DOOR ASSIST BOTTLE LOW. SERVICED THE 3L DOOR ASSIST BOTTLE.SDR USAA2014122200005Bottle · low pressureDOOR ASSIST BOTTLE PRESS IN YELLOW, NO ECAM MSG DOOR 3L. SERVICED DOOR ASSIST AS REQUIREDSDR USAA2014120100004Cover · missingDOOR 3R EXIT SIGN COVER MISSING. RELOCATED & REPOSITIONED EMER EXIT LIGHT ASSEMBLY AT 3R.SDR USAA2014112800005Cylinder · low pressureCHECK DOOR PRESS 3L SHOWN ON FWD ATTENDANT PANEL. CHARGED CYLINDER AT DOOR 3L.SDR USAA2014111700013Fitting · failedC2 CHECK L2 DOOR FWD ESCAPE SLIDE FITTING ASSEMBLY FAILED 04 OPERATIONS TEST. REPLACED L1 DOOR ESCAPE SLIDE GIRT BAR FITTING IAW AMM 30-46-11-PB401. GIRT BAR FITTING ADJUSTMENT GOOD IAW AMM 52-11-00-820-801-A. OPERATIONS TESTED GOOD IAW AMM 30-46-00-710-801SDR USAA2014111400014Terminal · looseC2 CHECK EMER LIGHTS ON SEATS 24G & H INOPERATIVE. FOUND TERMINAL OF EMER LIGHT AT SEAT 24G & H LOOSE. SECURED TERMINALS & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00. SYS CHECKED NORMAL.SDR USAA2014111400013Terminal · disconnectedC2 CHECK EMER LIGHTS INOPERATIVE ON SEATS. TROUBLE SHOT & FOUND TERMINAL DISCONNECTED. CONNECTED TERMINAL & PERFORMED OPERATIONAL CHECK IAW AMM 33-51-00-710-801-401. SYS CHECKED NORMAL.SDR USAA2014111400012Wire Harness · damagedC2 CHECK EMER ESCAPE LIGHTING WIRE IS DAMAGED AT SEAT 4A. R & R WIRE HARNESS AT SEAT 4A. OPERATIONS CHECKED IAW AMM 33-51-12-400-814. SYS CHECKED NORMAL.SDR USAA2014110300018Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 151NF BETWEEN FRAME 58 TO 60 & BETWEEN Y140 TO Y800. REPLACED FLOOR PANEL 151NF IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014110300017Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 151EF BETWEEN FRAME 54 TO 57 & BETWEEN Y140 TO Y800. REPLACED IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014110300016Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 132AG BETWEEN FRAME 37 TO 37.4 & BETWEEN -Y140 TO -Y800. REPLACED IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014110300015Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 132MF BETWEEN FRAME 25 TO 26.3 & BETWEEN -Y800 TO -Y1473. REPLACED IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014110300014Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 131LF BETWEEN FRAME 25 TO 26.3 & BETWEEN Y140 TO Y800. REPLACED FLOOR PANEL 131LF IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014110300013Floor Panel · delaminatedC2 CHECK DELAMINATION ON FLOOR PANEL 132LF BETWEEN FRAME 25 TO 26.3 & BETWEEN -Y140 TO -Y800. REPLACED IAW SRM 53-02-00-201 PARA 5I FIG 211.SDR USAA2014100600001Battery Pack · failed4L EMER BATTERY PACK FAILED DURING EPSU BATTERY CAP TEST, SELF-TEST OF BATTERY ILLUMINATED BATTERY LED. REMOVED 4L BATTERY PACK & INSTALLED SERVICEABLE BATTERY PACK. OPERATIONAL CHECK OF BATTERY SELF-TEST GOOD AT THIS TIME.SDR USAA2014051300002Cover · detached3L EXIT LIGHT COVER DETACHED. SECURED 3L EXIT LIGHT COVER, NOW OPERATES NORMAL.SDR USAA2014050600015Bottle · low pressureCLT 4R DOOR EMERGENCY ASSIST BOTTLE PRESS IS LOW. SERVICED 4R DOOR BOTTLE.SDR USAA2014050500002Damper · low pressureDURING DAILY CHECK FOUND DOOR DAMPER 3 LT IN RED BAND. ADJUSTED DOOR DAMPER PRESS.SDR USAA2014041700004Bottle · low pressureDOOR 2R ASSIST BOTTLE PRESS FOUND IN YELLOW BAND. SERVICED 2R ASSIST BOTTLE.SDR USAA2014041500001Bottle · low pressure3L DOOR BOTTLE ASSIST PRESS LOW. SERVICED 3L DOOR BOTTLE ASSIST.
Back to N272AY