Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N293WN' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N293WN' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026051904055Girt Bar · unsecureFWD SERVICE DOOR SLIDE WILL NOT STAY IN THE STOWED POSITION. RESECURED FWD SERVICE DOOR SLIDE GIRT BAR IN THE STOWED POSITION. REF AMM 25-66-01. OK FOR SERVICE.SDR SWAA2026021971705Battery Pack · no testEMERGENCY BATTERY PACK FAILED TIMED CHECK AT 14 ABC. R & R THE BATTERY PACK IAW AMM 33-51-06.SDR SWAA2025052072088Hook · out of adjustFWD SERVICE DOOR FORWARD GIRT BAR STOWAGE HOOK DOES NOT STOW GIRT BAR SECURELY <[01]. ADJUSTED FORWARD SERVICE DOOR; FORWARD GIRT BAR STOWAGE HOOK PER SIP. OPS CHECKS OK.SDR SWAA2025051467110Light · damagedFWD LAV EMERGENCY EXIT LIGHT DAMAGED<[01] REPLACED FWD LAVATORY 'A' EXIT LIGHT WITH NEW ASSEMBLY IAW AMM 33-51-01-960-802.;[02] ADDITION: SATISFACTORY OPERATIONAL TEST WAS ACCOMPLISHED;[03] VERIFIEDSDR SWAA2025051366262Floor Support · corrodedCORROSION ON ACB FLOOR SUPPORT INTERCOSTAL STA 767+5; RBL 25<[01] REMOVED AND REPLACED ACB FLOOR SUPPORT INTERCOSTAL AT STA 767 TO STA 787; RBL 25 LOT 1602576-1 I.A.W SRM 51-40-02-0G-0 AND DWG 146A0081 REV: A. ALL WORK ACCOMPLISHED ON FAULT TTG8Q00ZV5ZZ;[02] VSDR SWAA2025051465016Scuff Plate · crackedFWD CAREGO BAY FWD CORNER SCUFF PLATE IS CRACKED<[01] JOB CARD COMPLETED AND INSTALLED ON CUSTOMER CARD TTG8Q00ZSUFL;[02] REPAIRED FCB FWD CORNER SCUFF PLATE IAW SRM 53-30-15-2R-1; NDI NO CRACKS NOTED.;[03] VERIFIED ACTION 2.<BR>JOB COMPLETE.SDR SWAA2025051464309Plate · corrodedLWR FUSELAGE - ANTENNA COVER PLATE AREA HAS EVIDENCE OF CORROSION AND FILLET SEAL DETERIORATED AT STA 410; STR 27L.<[01] REMOVED AND REPLACED THE LWR FUSELAGE - ANTENNA COVER PLATE STA 410; STR 27L; IAW SRM 51-40-02 AND DWG #143A3230 REV A.;[02] VERIFIED ACTIOSDR SWAA2025051456877Floorbeam · crackedMAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO RBL 24.75.<[01] REMOVED AND REPLACED NEW PANEL BREAK ASSY P/N 143A5240-64 LOT 1601361-1 AT STA 540; BL 0 TO RBL 24.75 IAW SRM 51-40-02-0G-0 AND DWG 143A0060 REV: -.;[02] UPDATED MEASUREMENTS TABSDR SWAA2025051456875Floorbeam · crackedMAIN CABIN; FLOOR STRUCTURE SUPPORT HAS CRACK AT STA 540; BL 0 TO LBL 24.75.<[01] REMOVED AND REPLACED NEW PANEL BREAK ASSY P/N 143A5240-63 LOT 1602100-2 AT STA 540; BL 0 TO LBL 24.75 IAW SRM 51-40-02-0G-0 AND DWG 143A0060 REV: -.;[02] UPDATED MEASUREMENTS TABSDR SWAA2025051456870Panel · delaminatedPANEL 193D HAS DELAMINATION ON INNER SURFACE CORE<[01] DELAMINATION TO INNER SURFACE CORE OF PANEL 193D WAS REPAIRED IAW SRM 51-70-05-2R-2.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2025051356866Support Angle · corrodedCORROSION ON SUPPORT ANGLE ACB STA-767 TO 790 RBL-25 COMMON TO FWD SHIELD.<[01] REMOVED AND REPLACED NEW ON SUPPORT ANGLE ACB BS767 TO BS 787 RBL 25 IAW SRM 51-40-02 AND DWG 146A8123 ID: 0016 REV: -;[02] VERIFIED CORECTIVE ACTION;[03] VERIFIED CORECTIVE ACTIONSDR SWAA2025051456818Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT NUTPLATE HOLES AT RBL 27.5; RBL31.5; RBL35.5 AND RBL 43 WL208.1<[01] REPAIRED PASSENGER CABIN FLOOR BEAM BS 986 IAW SRM 53-70-51-2R-4 REPAIR-4;[02] COMPLETE;[03] VERIFY JOB COMPLETE;[04] COMPLETESDR SWAA2025051441158Vapor Barrier · crackedR/H VAPOR BARRIER CRACKED AT BS 663<[01] R/H VAPOR BARRIER CRACK AT BS 663 WAS REPAIRED IAW SRM 51-70-04-2R-10;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2025051441159Vapor Barrier · crackedL/H VAPOR BARRIER CRACKED AT BS 663<[01] L/H VAPOR BARRIER CRACK AT BS663 WAS REPAIRED IAW SRM 51-70-04-2R-10.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2025051456819Seal · crackedRT. HORIZONTAL STAB FWD UPPER SLIDE SEAL CRACKED.<[01] REMOVED AND REPLACED RT. HORIZONTAL STAB FWD UPPER SLIDE SEAL IAW AMM 53-31-31-000-802 AND AMM 53-31-31-400-802.<BR>USED TOOL: SCREW GUN<BR>ID: PER2472<BR>CAL DUE: 08/2025;[02] VERIFIED COMPLETION ACTION 1SDR SWAA2025051456782Support Angle · crackedWATER SERVICE PAN AFT SUPPORT ANGLE CRACKED AT APPROX. STA 907+15 (MARKED)<[01] REMOVED AND REPLACED WATER SERVICE PAN AFT SUPPORT ANGLE AT APPROX. STA 907+15 PER B737-700 SRM 51-40-02-OG AND BOEING DWG 147A7221 REV. F.;[02] CORRECTIVE ACTION ITEM 1 VERIFIED; SDR SWAA2025051456786Web · canningCORROSION ON ACB SUB THRESHOLD WEB AT MULTIPLE AREAS<[01] REMOVED AND REPLACED ACB THRESHOLD WEB IAW SRM 51-40-02-0G-0 AND DWG 146A8340; ID: 0024 REV: A.;[02] VERIFIED ACTION 1.<BR>JOB COMPLETE.SDR SWAA2025051456780Support · corrodedCORROSION ON ACB FLOOR TO SIDEWALL SUPPORT STA 747+10; LBL 25<[01] THIS CARD WILL BE ACCOMPLISHED ON TASK CARD # TTG8Q00ZV5YL<BR>FOR REPLACEMENT PART.;[02] VERIFIED;[03] VERIFIEDSDR SWAA2025051456791Shield · corrodedCORROSION ON FWD CARGO BAY DOOR CUT-OUT FWD SHIELD AT STA 420+2; 420+9; 420+17; WL 156; RBL 24.<[01] REMOVED AND REPLACED NEW ON FWD CARGO BAY DOOR CUT-OUT FWD SHIELD FROM BS420 TO BS440 RBL24 IAW SRM 51-40-02 AND DWG 143A0080 ID:0023 REV: -;[02] CORRECTIVE ACSDR SWAA2025051456783Shield · corrodedCORROSION ON FWD CARGO BAY DOOR CUT-OUT AFT SHIELD AT STA 500+12 AND 500+16; WL 156; RBL 24.<[01] REMOVED AND REPLACED NEW ON FWD CARGO BAY DOOR CUT-OUT AFT SHIELD FROM BS492 TO BS500A RBL24 IAW SRM 51-40-02 AND DWG 143A0080 ID: 0023 REV: -;[02] VERIFIED ACTIOSDR SWAA2025051456800Web · corrodedCORROSION ON FWD CARGO SUB-THRESHOLD WEB FROM STA 440+6 TO 480+9 RBL 25 TO RBL 28; WL 156.<[01] REMOVED AND REPLACED NEW ON FWD CARGO SUB-THRESHOLD WEB BS440 TO BS492.4 RBL 25 TO RBL28 WL 156 IAW SRM 51-40-02 AND DWG 143A8330 ID: 0042 REV: A;[02] CORRECTIVE ACSDR SWAA2025051456766Floor Support · crackedCRACKED INTERCOSTAL AT STA 324; RBL 30; WL 208.1<[01] REMOVED AND INSTALLED AT DISCREPANCY AREA NEW INTERCOSTAL PN:141A5410U140ATSMRO; LOT#1598453-1 PER DWG#141A5410; DWG141A5400 REV:_ SRM 51-40-05-0G-0; SRM 51-40-02.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2025051456815Seal · crackedLT HORIZONTAL STAB FWD UPPER SLIDE SEAL CRACKED.<[01] REMOVED AND REPLACED LT HORIZONTAL STAB FWD UPPER SLIDE SEAL <BR>PER AMM 53-31-31-000-802. (REMOVAL)<BR>PER AMM 53-31-31-400-802. (INSTALLATION)<BR>SCREW GUN ID: PER2469 DUE DATE:08/2025;[02] VERIFIED COMPLSDR SWAA2025051356788Sidewall Support · corrodedDAMAGE ON ACB FLOOR TO SIDEWALL SUPPORT STA 787; LBL 25<[01] REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT P/N 146A7502-27; LOT 1601300-2 AT ACB BS727 - BS847 LBL25 WL 156 IAW SRM 51-10-02 AND DWG# 146A7500 ID:0085 REV: A.;[02] VERIFIED CORRECTIVE ACTION. CARSDR SWAA2025051356802Floor Panel · pulledFWD FLOOR PANEL 222DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 222DF FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED PER [SRM 53-00-50-2R-0-A00938 (REPAIR GENERAL - COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051356798Floor Panel · pulledFWD FLOOR PANEL 222CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 222CF FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED PER [SRM 53-00-50-2R-1-A00939 (REPAIR 1 - REPAIR OF DAMAGE TO ONE FACESHEET IN COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051356801Floor Panel · pulledFWD FLOOR PANEL 221CF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FWD FLOOR PANEL 221CF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356781Shield · corrodedCORROSION ON ACB FWD SHEILD STA 767-792; RBL 25<[01] REMOVED AND REPLACED ACB FWD SHEILD STA 767-794; RBL 25 IAW SRM 51-10-02-0G-0 AND DWG# 146A0081 ID: 0040 REV: A.;[02] VERIFIED INSTALLATIONSDR SWAA2025051356779Sidewall Support · corrodedCORROSION ON ACB FLOOR TO SIDEWALL SUPPORT STA 727B+17; 727C+10; 727E+8; 727E+12; 727E+16; 747+7 - 767; RBL 25<[01] REMOVED AND REPLACED AT ACB FLOOR TO SIDE WALL SUPPORT <BR>BETWEEN BS 727 TO BS 767 RBL 25 WL 156 <BR>IAW SRM 51-40-02; DWG# 146A7500 REV: A;[02SDR SWAA2025051356789Sidewall Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT FROM STA 460 TO 500D; LBL 24; WL 156.<[01] REMOVED AND REPLACED NEW ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT BS400 TO BS500D LBL24 TO IAW SRM 51-40-02 AND DWG 143A7500 ID: OO71 REV: -;[02] VERIFIED CORRECTSDR SWAA2025051356771Floor Panel · pulledAFT FLOOR PANEL 241ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] 241ZF FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED PER [SRM 53-00-50-2R-1-A00939 (REPAIR 1 - REPAIR OF DAMAGE TO ONE FACESHEET IN COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051356769Floor Panel · debondedAFT FLOOR PANEL 241XF UPPER SKIN HAS A PREVIOUS REPAIR THAT IS DISBONDED. (MARKED)<[01] 241XF FLOOR PANEL UPPER SKIN DAMAGE HAS BEEN REPAIRED PER [SRM 53-00-50-2R-1-A00939 (REPAIR 1 - REPAIR OF DAMAGE TO ONE FACESHEET IN COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051456764Stub Frame · crackedCRACK FOUND ON FSD STUB FRAME AT BS 291.5+8; .2' ABOVE SEAL DEPRESSOR; 1.6' IN LENGTH<[01] EVALUATED DAMAGE; NO ALLOWABLE DAMAGE FOUND AT SRM; UPPER STUB FRAME TO BE REPAIRABLE BY REPLACEMENT PER SRM 51-10-02; STEP 9. REMOVED FWD SERVICE DOOR UPPER STUB FRAME SDR SWAA2025051456759Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT NUTPLATE HOLE RBL 43; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.;[03] CHANGED MEASUREMENTS FIELD ON RII TO NO AND MAJOR REPAIR TO NO DAMAGE REPAIRED OSDR SWAA2025051456760Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 35.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051456761Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 31.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051456762Floorbeam · corrodedCORROSION ON BS986 FLOOR BEAM AT BOTTOM SIDE OF NUTPLATE HOLE RBL 27.5; WL 208.1<[01] THE FLOOR BEAM REPAIR WILL BE COMPLETED ON COSTUMER CARD # TTG8Q00ZWBA6;[02] CORRECTIVE ACTION COMPLETED.SDR SWAA2025051456690Vapor Barrier · crackedR/H VAPOR BARRIER CRACKED AT BS 663<[01] REMOVED; REINSTALLED AND RAPAIRED VAPOR BARRIER IAW B737-7 SRM 51-40-02-0G-0 DWG 111A1000 ID: 0259 REV: A AND REINSTALLED ALL PARTS TO FOM.;[02] COMPLETE;[03] COMPLETE;[04] VERIFIED;[05] ALL REPAIR WORK ACCOMPLISHED ON SDR SWAA2025051456694Vapor Barrier · crackedL/H VAPOR BARRIER CRACKED AT BS 663<[01] L/H VAPOR BARRIER BS663 REPAIRED IN TTG8Q00ZWLU7;[02] REMOVED AND REINSTALLED L/H VAPOR BARRIER AT BS 663 LBL6-LBL70 IAW SRM 51-40-02 & DWGS 111A1000 ID:0259 REV: A;[03] VERIFIED ACTION 2.<BR>JOB COMPLETE.SDR SWAA2025051356692Floor Panel · pulledFLOOR PANEL 242PF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 242PF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356691Floor Panel · pulledFLOOR PANEL 241WF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241WF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356688Floor Panel · pulledFLOOR PANEL 241VF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241VF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356687Floor Panel · pulledFLOOR PANEL 241UF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241UF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356682Floor Panel · pulledFLOOR PANEL 241DF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241DF UPPER SKIN WITH AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL PER SRM 53-00-50-2R-0 DUE TO AMOUNT OF ALL DAMAGE.SDR SWAA2025051356681Floor Panel · pulledFLOOR PANEL 241BF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 241BF WAS REPLACED. FABRICATED NEW PANEL IAW SRM 53-00-50-2R-0 & BOEING DWG 144A5810 ID 0189.;[02] VERIFIED CORRECTIVE ACTION ITEM 1.SDR SWAA2025051356680Floor Panel · pulledFLOOR PANEL 241AF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW 241AF FLOOR PANEL REPLACEMENT HAS BEEN ACCOMPLISHED PER [SRM 53-00-50-2R-0-A00938 (REPAIR GENERAL - COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051356679Floor Panel · pulledFLOOR PANEL 232SF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 232SF; WITH UPPER SKIN AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2025051356678Floor Panel · pulledFLOOR PANEL 232RF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FLOOR PANEL 232RF; WITH UPPER SKIN AREAS OF PULLED STRANDS WAS REPLACED WITH A NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0.SDR SWAA2025051356677Floor Panel · pulledFLOOR PANEL 231ZF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW 231ZF FLOOR PANEL REPLACEMENT HAS BEEN ACCOMPLISHED PER [SRM 53-00-50-2R-0-A00938 (REPAIR GENERAL - COMPOSITE FLOOR PANELS - PERMANENT)]SDR SWAA2025051356684Floor Panel · pulledFLOOR PANEL 231YF UPPER SKIN HAS AREAS OF PULLED STRANDS.<[01] FABRICATION OF NEW 231YF FLOOR PANEL HAS BEEN ACCOMPLISHED PER [SRM 53-00-50-2R-0-A00938 (REPAIR GENERAL - COMPOSITE FLOOR PANELS - PERMANENT)]
Back to N293WN