N301DV
Service difficulty reports · 33
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N301DV' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N301DV' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025082906392Electrical Box · faultedIFE SYSTEM INOP (PARTIALLY OPERATIVE) AT LOCATIONS:1C / MYCABIN - ADDITIONAL LOCATIONS 1D,2C,2D,3C,3D, 5C,5D - CREW HAS TAKEN THIS AC ON A PREVIOUS FLIGHT FROM IAH-ATL. ALL IFE WORKED. RESET 3 TIMES, INCLUDING CLOSING THE FLIGHT AND REOPENING IT. ELECTRICAL BUSDR DALA2025060104201Apu · contaminatedAIRCRAFT 3001, ACRID WET SOCK SMELL NOTICED DURING TAXI BACK IN REAR OF AIRCRAFT. CORRECTIVE ACTION: OIL FOUND IN APU INLET. COMPLETED A321 AMM TASK 21-00-615-803-A PARA1 THRU 4.F(C)4. STAGE 1 CLEANING OF ECS COMPLETED STAGE 2 USING HP GROUND AIR REF. A321 AMMSDR DALA2025051603787Handle · looseSHIP 3001 LEFT OVERWING EMERG DOOR ASSIST HANDLE LOOSE. CORRECTIVE ACTION: REALIGNED NUTPLATE. RESECURED DOOR ASSIST HANDLE OF THE LEFT OVERWING EMERGENCY DOOR IAW A321 AMM 20-21. OPS CHK OK. (7040428)SDR DALA2025051603790Apu · contaminatedSHIP 3001 DIRTY SOCK SMELL ON DECENT WHEN ENGINES WERE AT IDLE. WHEN POWER WAS ADDED BACK IN SMELL WENT AWAY. SMOKE AND FUME SUBMITTED. CORRECTIVE ACTION: DUE TO OIL INGESTION AT APU INLET, GRILL AND VANES. PREFORMED ENG RUNS AND SNIFFER TEST INITIALLY HAS SMESDR DALA2025031101885Lever · bindingSHIP 3001 ENTRY DOOR ARMING LEVER HARD TO OPERATE / LOCATIONS:605. CORRECTIVE ACTION: TIGHTENED BOLT AS REQ-OP NORMAL (0850475)SDR DALA2025022401444Unknown · odorSHIP 3001 STRONG DUSTY ODOR THROUGHOUT CABIN DURING DECENT BELOW 9000. PERSISTED THROUGH LANDING. CORRECTIVE ACTION: DEBRIEFED CREW AND CONFIRMED THEY DETECTED ODOR IN CABIN. ADVISED MCC OF INBOUND WRITE UP AND SUBMITTED SMOKE AND FUME REPORT. AS PER MCC COMPLSDR DALA2025012000462Inlet · contaminatedSHIP 3001 - FUMES/DE - ON APPROACH FLIGHT CREW EXPERIENCED FUMES IN COCKPIT AFTER TURNING ANTI-ICE ON. OXYGEN MASKS DONNED AND EMERGENCY DECLARED. CORRECTIVE ACTION: FOUND APU INLET CONTAMINATED WITH DE-ICE FLUID. CLEANED RESIDUAL FLUID FROM APU INLET AND PERFSDR DALA2024082808509Idg · low pressureSHIP 3001 - ATO - ABOVE 80KTS DUE TO AN IDG 1 LOW OIL PRESSURE MESSAGE. CORRECTIVE ACTION: DEFERRED IDG 1 PER MEL. LATER, REPLACED THE NBR 1 ENGINE IDG. (LP 9982888)SDR DALA2024060405755Unknown · contaminatedSHIP 3001 -ATB- DUE TO DIRTY SOCK SMELL AFTER APU START. SMELL DID NOT DISSIPATE AFTER TAKEOFF. CORRECTIVE ACTION: FOUND FOUL FLUID ALL OVER THE FORWARD CARGO COMPARTMENT FLOOR AND VOMIT AT ROW 15 ABC. FORWARD CARGO COMPARTMENT FLOOR REMOVED AND CLEANED. R/R CSDR DALA2024060205735Connector · brokenAIRCRAFT 3001, CABIN EMERGENCY LIGHTS OUT ON SEATS ROW 19 & 20. CORRECTIVE ACTION: FOUND BROKEN WIRE AT CONNECTOR UNDER AT 19A (532226) REPIARED WIRE PER A 321 AWM 33-51. EMERGENCY LIGHT WORK AS INTENDED. RECONNECTED PLUG ON ROW 20 PER A321 AWM 33-51. (LP 5978SDR DALA2024052005372Light · brokenAIRCRAFT 3001, ON SRVC CHECK FOUND E-LIGHT SEAT MOUNTED WITH BROKE HOUSING AT ROW 24ABC. CORRECTIVE ACTION: REPLACED 24ABC E-LIGHT HOUSING. (LP 5978702)SDR DALA2023110609117Unknown · unknownSHIP 3001 MID LAV PAX O2 GEN DOOR WILL NOT LATCH CLOSED. CORRECTIVE ACTION: R/R MID LAV 02 GENERATOR BOX PER A321 AMM 35-21. OP CHECK GOOD. (5064652)SDR DALA2023103108933Unknown · unknownSHIP 3001 EMERGENCY EXIT LIGHTS AT 26B, AND 13C DAMAGED. CORRECTIVE ACTION: REMOVED AND REPLACED EMERGENCY EXIT LIGHTS AT 26B AND 13C PER A321 AMM 33-51. TEST GOOD. (5064637)SDR DALA2023102608800Unknown · unknownSHIP 3001 F/A REPORTS O2 MASK IN LAV 2 DROPPED DOWN ON CLIMB OUT. CORRECTIVE ACTION: STOWED MASK PER A321 AMM 35-21, NO DEFECTS NOTED. (5064614)SDR DALA2023102508795Unknown · unknownSHIP 3001 SEAT MOUNTED EMERGENCY LIGHTS AT ROWS 20 AND 30 INOP. CORRECTIVE ACTION: REPAIRED PER A321 AMM 33-52. (5064610)SDR DALA2023041803087Unknown · unknownSEAT ROW 34 FLOOR EMERG LIGHT INOP. RPLD BROKEN MALE CONTACT OUT BOARD SIDE OF SEAT ASSY IAW SWPM CHAPTER 20LIGHT TEST CHECKS GOOD. (LP# 9695182)SDR DALA2022042102806None · noneMISALIGNED HOLE AT REGULATOR VALVE OF RESERVOIR ON 841 DOOR. REPLACED SLIDE OF 841 DOOR AND INSTALLATION PROCEDURE IS DOCUMENTED AS PER AMDS CARD 2561-4002-RE AS PER TOPP 50-00-15 RIIINSPECTION COMPLETE 0033889 (AE116QC) JOB COMPLETE. (LP# 2204548)SDR DALA2022042102804None · noneCORROSION SHEAR PLATE STR 23 R LOCATED BTW FR 69 TO FR 70 AT AFT GALLE Y AREA (SSI 534147). REPLACED SHEAR PLATE STRG23 RH LOCATED BTW FR69 TO FR70 AT AFT GALLEY AREA ASPER A321 SRM 51-72-11-911-001 AND DWG D53474180ISSUE: U. RII INSPECTION COMPLETE 0856971. JSDR DALA2022042102803None · noneCORROSION FLOOR STRUCTURE LOC. BTW FR 68 -Y254 AT AFT GALLEY AREA (SS I 534147). REPAIRED FLOOR STRUCTURE LOC. BTW FR 64 TO 68 -Y254 AT AFT GALLEY AREA AS PER ER/A 598646-14 REPAIR CLASSIFICATION: MINOR AS PERER/A 598646-14 RII INSPECTION COMPLETE 007634 (AE71SDR DALA2022042102802None · noneCORROSION FLOOR STRUCTURE BEAM LOCATED BTW FR 68 TO FR 70 AND -Y 160.5 AT AFT GALLEY AREA (SSI 534147). COMPLIED WITH PRI 598715-14 REV0 AND REV1 VALIDATED ERA 598715-14 PERFORMED PERMANENT REPAIR ON FLOOR STRUCTURE BEAM LOCATED BTWFR 68 TO FR 70 AND -Y 160.5 SDR DALA2022041902670None · noneCRACK SHEAR PLATE LOCATED BTW FR 69 TO FR 70 LEVEL STR 23L AT AFT GALL EY AREA. REPLACED SHEAR PLATE LOCATED BTW FR 69 TO FR 70 LEVEL STR 23L AT AFT GALLEY AREA AS PER SRM A321 51-72-11-801 AND DWG D53474180ISSUE: U RII INSPECTION COMPLETE 0856971. (LP# 219787SDR DALA2022041402598None · noneCORROSION FLOOR STRUCTURE LOC. BTW FR 66TO FR 70 Y765 AT AFT GALLEY AREA (SSI 534147). REPLACED FLOOR BEAM AND FASTENERS LOCATED BETWEEN FR66 TO FR70 Y765 AFT GALLEY AREA AS PER A321 SRM 51-72-11-911 AND DRAWING D53472904 RELEASE DATE 02MAR21, ISSUE A. RII INSSDR DALA2022041202536None · noneSHIP 3001 CORROSION FLOOR STRUCTURE LOC. BTW FR 64 TO FR 66 Y765 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM AND FASTENERS PER A321 SRM 51-72-11. (2189330)SDR DALA2021120907590None · noneSHIP 3001 EMERG. PATH LIGHT AT SEAT 21C BROKEN. CORRECTIVE ACTION: INSTALLED NEW LIGHT ASSY PER A321 AMM 33-51. OK FOR SERVICE. (8402933)SDR DALA2019123097605Light · disconnectedFOUND SEAT MOUNTED EMERGENCY LIGHTS INOP AT SEAT 19ABC, FOUND EMERGENCY LIGHT DISCONNECTED, RECONNECTED LIGHTSDR DALA2019121707396Light · damagedEMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS:15C, REPLACED EMERGENCY LIGHT ASSY AND MOUNTSDR DALA2019090205170Housing · brokenROW 11 ABC EMERGENCY LIGHT BROKEN OFF, REPLACED EMERGENCY LIGHT HOUSING & PAN AT SEAT 11 ABC.SDR DALA2019061803629Cooling Fan · leakingDIRTY SOCK ODOR @ LOW POWER SETTING, FOUND APU COMPARTMENT OILY, FOUND APU COOLING FAN LEAKING OIL, REPLACED FANSDR DALA2019031101562Cap · missingPDA PART DEPARTING AIRCRAFT. LOG PAGE 5342384. FLT/CHK 1297 NON ROUTINE LINE SDR:N POSITION: LT TASK HRS: 000003.2 TASK ELAPSE TIME HRS: 000003.2 01. W ON SVC CHECK FOUND 3 WING TIP INSPECTION CAPS MISSING LT WING. LOG-PAGE UPDATED @ 06MAR19 0833 UTC. DEF TO MSDR DALA2018072804750Light · inoperativeEMERGENCY FLOOR LIGHTING DAMAGED/INOPERATIVE. INSTALLED NEW EMERGENCY PATH LIGHTING ASSEMBLY.SDR DALA2018040602244Housing · damagedEMERGENCY SEAT MOUNTED LIGHTING DAMAGED, REPLACED EMERGENCY EXIT LIGHT HOUSING AT 29C BELOW SEAT.SDR DALA2018042402770Spar · crackedNR 1 PYLON, UPPER SPAR OF AFT FIXED FAIRING WAS FOUND CRACKED INBD SIDE. INSTALLED A REPAIR IAW AMDS 5450-01052-03A.SDR DALA2017112708355Battery Pack · faulted11WL EPSU FAULTING DURING EPSU SYSTEM TEST, REPLACED EPSU BATTERY 11WL
Back to N301DV