N308PQ

Service difficulty reports · 59

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N308PQ' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR REXA2017031200366Flashlight · inoperativeFORWARD FA FLASHLIGHT INOP. R&R FWD FA FLASHLIGHT PER CMM 25-60-02 P/N P2-07-0001-214.Mar 12, 2017 · N308PQ · Cndair CL6002D24 · Emergency EquipmentSDR REXA2017020800172Oxygen Mask · deployedA MAN BUMPED HIS HEAD ON THE O2 COVER IN FOWARD LAV AND THE O2 MASKS DEPLOYED IN THE LAV. REPACKED O2 MASK IAW CRJ900 AMM 35-21-17. OP CK GOOD ACFT OK FOR SERVICE.Feb 8, 2017 · N308PQ · Cndair CL6002D24 · Passenger Oxygen SystemSDR REXA2017011900073Fan · failedDISPLAY COOL CAUTION MESSAGE & BURNING ODOR. FAN FAILED. PERFORMED TROUBLESHOOTING IAW FIM 21-24-12. FOUND THE FAN TO BE FAULTY. R & R THE NR 2 AVIONIC COOLING FAN IAW AMM 21-24-00. OPS CHECKED GOOD.Jan 19, 2017 · N308PQ · Cndair CL6002D24 · Air Distribution FanSDR REXA2016080101456Acm · malfunctionedDURING ARRIVAL, F/A CALLED FLIGHT DECK COMPLAINING OF BURNING PLASTIC AND OR SULFUR ODOR AND A LITTLE VISIBLE SMOKE IN CABIN AROUND ROW 7. CAPTAIN ASKED F/A TO IDENTIFY SOURCE OF SMOKE. F/A THEN ADVISED THAT SMOKE ODOR HAD DISSIPATED. THIS EVENT LASTED LESS TAug 1, 2016 · N308PQ · Cndair CL6002D24 · Cabin Cooling SystemSDR REXA2015080900775Latch · unsecure12A EXIT DOOR LATCH NEEDS TO BE SECURED. RE-ATTACHED LT FWD OVERWING EMER EXIT DOOR HANDLE TRIM COVER IAW AMM 52-21-00. OK FOR SERVICE.Aug 9, 2015 · N308PQ · Cndair CL6002D24 · Emergency ExitsSDR REXA2015060600560Flashlight · inoperativeMAIN PAX DOOR FLIGHT ATTENDANT FLASHLIGHT NOT WORKING. DEFERRED MAIN PAX DOOR FLASHLIGHT IAW MEL 25-61-4A, MM02 UPDATED. PLACARD INSTALLED. CONTROL 3173746-1. R & R FLASHLIGHT ASSEMBLY IN GALLEY NEAR MAIN PAX DOOR IAW AMM 25-61-02. OPERATIONS TESTED NORMAJun 6, 2015 · N308PQ · Cndair CL6002D24 · Emergency EquipmentSDR REXA2015020800182Trim Panel · detachedFLOOR TRIM CAME OFF IN GALLEY. SECURED GALLEY FLOOR EMER LIGHT STRIP IAW AML 33-51-01. ACFT OK FOR SERVICE.Feb 8, 2015 · N308PQ · Cndair CL6002D24 · Emergency LightingSDR REXA2015011900061Circuit Breaker · defectiveWITH ALL EMER LIGHT SWITCHES IN OFF POSITION REPOWERED ACFT WITH APU ALL APPROPRIATE ELEC BUSES POWERED WHEN THE EMER LIGHTS ARE SELECTED TO ARM. ALL THE LIGHTS ILLUMINATE WHEN SELECTED TO ON, THEY ALSO ALL ILLUMINATE THE ONLY WAY TO SHUT OFF EMER LIGHTS IS TJan 19, 2015 · N308PQ · Cndair CL6002D24 · Emergency LightingSDR REXA2014090400863Light · missingFLOOR TRACK LIGHTING 5B MISSING. REPLACED FLOOR EMER TRACK LIGHTING CLIP IAW AMM 33-51-01. ALL CHECKED GOOD, PN PL88-910LH00.Sep 3, 2014 · N308PQ · Cndair CL6002D24 · Emergency Lighting
Back to N308PQ