N324RN

Service difficulty reports · 28

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N324RN' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA202609250849Extinguisher · low pressureAIRCRAFT WAS NOT GROUNDED: COCKPIT PORTABLE FIRE EXTINGUISHER PRESSURE IS SHOWING NEAR ZERO. REMOVED AND REPLACED PORTABLE FIRE EXTINGUISHER IAW AMM 26-26-01-401.Sep 24, 2026 · N324RN · Boeing 7378 · Fire Bottle, PortableSDR AALA202607128509Sign · malfunctionedAIRCRAFT WAS NOT GROUNDED: EXIT LIGHTS ON ROW 17ABC DO NOT TURN OFF. MAINTENANCE REPLACED OVERWING EXIT LIGHT ASSY REF AMM 33-21-00-960-802.Jul 9, 2026 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202606205697Light · faultedAIRCRAFT WAS NOT GROUNDED: LEFT OVER WING EMERGENCY EXIT LIGHT IS FLICKERING AND LIGHT STRIP SHOWING A RAINBOW SET OF LIGHTS. MAINTENANCE REPLACED EMERGENCY ROW SIDEWALL LIGHT IAW AMM 33-21-00Jun 17, 2026 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202605202430Door Latch · lack of lubeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTS THAT LAVATORY-D DOOR LOCK MECHANISM JAMS IN THE LOCK POSITION AND DIFFICULT TO OPEN. EXERCISED AND LUBRICATED DOOR LOCK. PER AMM 52-50-00.May 18, 2026 · N324RN · Boeing 7378 · Fixed Inner DoorsSDR AALA202511263222Door Latch · lack of lubeAIRCRAFT WAS NOT GROUNDED: LEFT AFT LAVATORY-D INTERIOR LOCKING BOLT DIFFICULT TO OPERATE IN ORDER TO EXIT LAVATORY. LUBRICATED THE DOOR LOCKING MECHANISM ASSEMBLY OF LAVATORY-D. PER CMM 25-40-58.Nov 24, 2025 · N324RN · Boeing 7378 · Fixed Inner DoorsSDR AALA202511124246Power Supply · no testAIRCRAFT WAS GROUNDED: EMERGENCY LIGHT ON OVERWING EXIT ROW 16FED DOES NOT ILLUMINATE. REPLACED RIGHT HAND OVER WING EMERGENCY LIGHT POWER SUPPLY M1695. PER AMM 33-51-06.Nov 10, 2025 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202511105684Circuit Breaker · trippedAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT SIGN IN AFT GALLEY AND ON L2 SERVICE DOOR DID NOT WORK. FOUND EMERGENCY LIGHTING LEFT AFT CIRCUIT BREAKER OUT. RESET CIRCUIT BREAKER. PER GPM13-04-07. PERFORMED EMERGENCY LIGHTS OPERATIONAL TEST, PER AMM 33-51-00. OPERNov 9, 2025 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202511104132Circuit Breaker · trippedAIRCRAFT WAS NOT GROUNDED: EMERGENCY PATH LIGHTING ON LEFT SIDE FROM 16CBA TO 33CBA DID NOT WORK. FOUND EMERGENCY LIGHTING L AFT CIRCUIT BREAKER OUT. RESET CIRCUIT BREAKER. PER GPM13-04-07. PERFORMED EMERGENCY LIGHTS OPERATIONAL TEST, PER AMM 33-51-00. OPERATINov 9, 2025 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202510060718Carpet · contaminatedAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY REPORTED AS STRONG ODOR FROM FLIGHT ATTENDANTS. ODOR IS STILL PRESENT AFTER A DEEP CLEANING, REPEAT WRITEUP. **SUPPLEMENTAL REPORT FOR (AALA202510030718): REMOVE AND REPLACED LAVATORY-E TOILET ASSEMBLY (AALA20251006928Oct 3, 2025 · N324RN · Boeing 7378 · LavatoriesSDR AALA202510069285Toilet · contaminatedAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY REPORTED AS STRONG ODOR FROM FLIGHT ATTENDANTS. ODOR IS STILL PRESENT AFTER A DEEP CLEANING, REPEAT WRITEUP. REMOVE AND REPLACED LAVATORY-E TOILET ASSEMBLY (AALA202510069285), PER AMM 38-32-01. ALSO, REMOVED AND REPLAOct 3, 2025 · N324RN · Boeing 7378 · Waste Disposal SystemSDR AALA202510030718Lavatory · odorAIRCRAFT WAS GROUNDED: RIGHT AFT LAVATORY REPORTED AS STRONG ODOR FROM FLIGHT ATTENDANTS. ODOR IS STILL PRESENT AFTER A DEEP CLEANING, REPEAT WRITEUP. (OPEN).Oct 3, 2025 · N324RN · Boeing 7378 · Water and Waste SystemSDR AALA202508051342Battery Pack · abnormalAIRCRAFT WAS NOT GROUNDED: EMERGENCY ESCAPE LIGHTING INOPERATIVE AT ROWS 8-14. REMOVE AND REPLACED EMERGENCY LIGHT BATTERY PACK AT ROW 10. PER AMM 33-51-06. OPERATIONAL CHECK GOOD.Aug 5, 2025 · N324RN · Boeing 7378 · Emergency LightingSDR AALA202503187448Handle · stickingAIRCRAFT WAS NOT GROUNDED: FORWARD LAVATORY DOOR HANDLE STICKS. HARD TO UNLATCH. READJUST FORWARD LAVATORY DOOR HANDLE. OPERTIONAL CHECK GOOD. PER AMM 52-51-00.Mar 17, 2025 · N324RN · Boeing 7378 · Fixed Inner DoorsSDR AALA202404114537Tube · missingAIRCRAFT WAS NOT GROUNDED: 1L DOOR MISSING ONE RED GIRT BAR HEATSHRINK. REPLACED MISSING RED TAPE ON GIRT BAR. PER AMM 25-66-01.Apr 10, 2024 · N324RN · Boeing 737823 · Emergency EquipmentSDR AALA202403055281Cover · missingAIRCRAFT WAS NOT GROUNDED: FORWARD SERVICE DOOR GIRT BAR MISSING RED PLASTIC ON ONE SIDE. INSTALLED RED COVER. PER AMM 25-60-00, OK FOR SERVICE.Mar 4, 2024 · N324RN · Boeing 737823 · Emergency EquipmentSDR AALA202401254561Sign · missingAIRCRAFT WAS GROUNDED: EMERGENCY EXIT WINDOW LIGHT ASSEMBLY FOR EXIT WINDOW AT 16A MISSING. REPLACED EMERGENCY EXIT ANNUNCIATOR SIGN. FUNCTIONAL CHECK GOOD. PER AMM 33-51-01-960-802.Jan 23, 2024 · N324RN · Boeing 737823 · Emergency LightingSDR AALA202306201144Battery Pack · inoperativeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT FLASHLIGHT AT FORWARD OUTBOARD SIDE INOPERATIVE. REMOVED AND REPLACED FLIGHT ATTENDANT FLASHLIGHT BATTERY PACK.Jun 19, 2023 · N324RN · Boeing 737823 · Emergency EquipmentSDR AALA202304286384Light · missingAIRCRAFT WAS NOT GROUNDED: THE EMERGENCY FLOOR PROXIMITY LIGHT ASSEMBLY IS MISSING ON SEATROW 24 A,B,C. REPLACED LIGHT ASSEMBLY AT SEAT 24C.Apr 27, 2023 · N324RN · Boeing 737823 · Emergency LightingSDR AALA202301234436Windshield · crackedAIRCRAFT WAS GROUNDED: ELECTRICAL SNAPPING HEARD FROM FIRST OFFICER R1 WINDSHIELD. ELECTRICAL BURNING SMELL NOTED. MAINTENANCE FOUND WINDSHIELD CRACKED. REPLACED WINDSHIELD PER JOB CARD 09C21056004.** (CLOSED)Jan 19, 2023 · N324RN · Boeing 737823 · Flight Compartment WindowsSDR AALA202301204436Windshield · sparksAIRCRAFT WAS GROUNDED: ELECTRICAL SNAPPING HEARD FROM FIRST OFFICER`S R1 WINDSHIELD. ELECTRICAL BURNING ODOR NOTED. (OPEN)Jan 19, 2023 · N324RN · Boeing 737823 · Flight Compartment WindowsSDR AALA202207121416None · missingAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT COVER MISSING AT 8C. REPLACED SEAT MOUNTED FLOOR PROXIMITY LIGHT PER AMM 33-51-11. OPERATIONAL CHECK NORMAL.Jul 9, 2022 · N324RN · Boeing 737 · Emergency LightingSDR AALA202109131923Battery · inoperativeAIRCRAFT WAS NOT GROUNDED: FORWARD EMERGENCY FLASH LIGHT INOPERATIVE. REPLACED BATTERY PER AMM 25-64-00.Sep 11, 2021 · N324RN · Boeing 7378 · Emergency EquipmentSDR AALA202109094989Latch · stickingAIRCRAFT WAS NOT GROUNDED: AFT LEFT LAVATORY DOOR DIFFICULT TO OPEN AND CLOSE. CLEANED AND LUBRICATED LATCH.Sep 8, 2021 · N324RN · Boeing 7378 · Fixed Inner DoorsSDR AALA202109077366Retainer · out of positionAIRCRAFT WAS NOT GROUNDED: FWD SERVICE DOOR GIRT BAR DIFFICULT TO REMOVE FROM RH HOLDING BRACKET. ADJUSTED CLIP IAW AMM 25-66-00, OPS CHECK GOOD.Sep 5, 2021 · N324RN · Boeing 7378 · Emergency EquipmentSDR AALA202102119009Grommet · missingAIRCRAFT WAS NOT GROUNDED: GROMMET MISSING ON THE L1 DOOR GIRT BAR. INSTALLED NEW GROMMET IAW AMM 25-61-01.Feb 10, 2021 · N324RN · Boeing 737823 · Emergency EquipmentSDR AALA202101269013Girt Bar · missingAIRCRAFT WAS NOT GROUNDED. L1 ENTRY DOOR GIRT BAR MISSING LEFT WHITE STOPPER. INSTALLED NEW GIRT BAR STOPPER.Jan 25, 2021 · N324RN · Boeing 7378 · Passenger/Crew DoorsSDR AALA202012239007Spring · out of positionAIRCRAFT WAS NOT GROUNDED. L1 DOOR GUST LOCK INOPERATIVE. PLACED SPRING OVER CAM AND LINK, IAW AMM 52-11-21-400-801. OPERATIONS CHECK GOOD.Dec 22, 2020 · N324RN · Boeing 7378 · Passenger/Crew DoorsSDR AALA2018100439014Connector · unsecureEMERGENCY LIGHT FROM ROWS 8 TO 14 DID NOT WORK. CONNECTED AND SECURED THE CONNECTOR D12802 AT ROW 8 LEFT IAW WDM 33-51-21. SEAT MOUNTED EMERGENCY LIGHTS OPS NORMAL IAW AMM 33-51-00.Oct 1, 2018 · N324RN · Boeing 7378 · Light System Wiring
Back to N324RN