N339DN
Service difficulty reports · 24
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N339DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N339DN' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2026101205585Engine · bird ingestionPERFORMED AN AIR TURN BACK DUE TO NR 2 ENGINE BIRD STRIKE WITH VIBRATION AND ENGINE STALL ECAM MESSAGE. MTC FOUND FAN BLADE DAMAGE AND ENGINE REQUIRED BORESCOPE RESULTS WERE CLEAN. MTC REPLACED FAN BLADE SET AND PERFORMED WATER WASH OF ENGINE. (LP 9496934, 949SDR DALA2024092509412Cids · faultedAIRCRAFT 3039, OVERHEAD EMERGENCY LIGHTS ILLUMINATED IN CABIN UNABLE TO RESET. CORRECTIVE ACTION: RESET CIDS SYS PER A321 AMM 33-50 OPS CK SYSTEM OPS CK NML A/C OK FOR SVC. (LP 4005440)SDR DALA2024010500187Unknown · unknownSHIP 3039 AFTER SHUTDOWN AT GATE ECAM CAB PR EXCESS RESIDUAL PR APPEARED WITH MASTER WARNING. THE PRESSURE LIGHT ALSO APPEARED ON THE L1 DOOR. CORRECTIVE ACTION: R/R RPCU PER A321 AMM 21-31, OPS CK GOOD. (5505430)SDR DALA2023122210515Unknown · unknownSHIP 3039 GIRT BARS ON DOORS 831 AND 841 WERE OUT OF ADJUSTMENT. CORRECTIVE ACTION: REMOVED, RE-ADJUSTED AND RE-INSTALLED SLIDE RAFT GIRT BARS FOR DOORS 831 AND 841. OK FOR SERVICE. (0120271)SDR DALA2023121910376Unknown · unknownSHIP 3039 DETERIORATED PASSENGER CREW DOOR 842 UPPER AND LOWER CONNECTION LINK BUSHINGS AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED PASSENGER CREW DOOR 842 UPPER AND LOWER CONNECTION LINK BUSHINGS AT AFT GALLEY AREA PER A320 AMM 52-13-21. (0116395)SDR DALA2023121910377Unknown · unknownSHIP 3039 WEAR ON PASSENGER CREW DOOR 831 UPPER AND LOWER CONNECTION LINK BUSHINGS AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED PASSENGER CREW DOOR 831 UPPER AND LOWER CONNECTION LINK BUSHINGS. (0116058)SDR DALA2023121810329Unknown · unknownSHIP 3039 OUT OF ADJUSTMENT PASSENGER CREW DOOR 832 COMPENSATION MECHANISM POINT K AT AFT GALLEY AREA. CORRECTIVE ACTION: ADJUSTED DOOR PER A321 AMM 52-13-21. OK FOR SERVICE. (0112967)SDR DALA2023121810330Unknown · unknownSHIP 3039 WEAR ON PASSENGER CREW DOOR 841 UPPER AND LOWER CONNECTION LINKS. CORRECTIVE ACTION: REPLACED BUSHINGS. OPS CHECK GOOD. (0111850)SDR DALA2023121410271Unknown · unknownSHIP 3039 EXCESSIVE PLAY ON LH MLG DOOR ACTUATOR UPPER AND LOWER SPHERICAL BEARINGS. CORRECTIVE ACTION: REPLACED BEARINGS (1 EA) ON END FITTING AND (1 EA) ON EYE END OF MAIN DOOR ACTUATOR LH SIDE. OK FOR SERVICE. (0108556)SDR DALA2023121410270Unknown · unknownSHIP 3039 EXCESSIVE PLAY ON RH MLG DOOR ACTUATOR UPPER AND LOWER SPHERICAL BEARINGS (2 EA). CORRECTIVE ACTION: REPLACED BEARINGS (1 EA) ON END FITTING AND (1 EA) ON EYE END OF MAIN DOOR ACTUATOR. OK FOR SERVICE. (0108554)SDR DALA2023121210170Unknown · unknownSHIP 3039 WEAR ON PASSENGER CREW DOOR 831 HOOK INNER CONTROL HANDLE AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED HOOK INNER CONTROL HANDLE DOOR 831 PER A321 AMM 52-11-21-400-001-A. (0105464)SDR DALA2023121110139Unknown · unknownSHIP 3039 CRACKED SHEAR PLATE STR 23 R LOC BRE FR69 TO FR70 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED SHEAR PLATE PER A321 SRM 53-41-17-01A, SRM 51-72-11 AND SRM 51-42-11. (0102033)SDR DALA2023092007742Unknown · unknownON FINAL AROUND 4000 FT MSLA FISH/OILY SMELL WAS NOTICED IN THE COCKPIT AND AFT CABIN. ALL INDICATIONS WERE NORMAL. INSPECTED NO. 1 AND NO. 2 ENGINE INLET AND EXHAUST FOR OIL NONE NOTED. FOUND APU INLET AND APU DOORS SATURATED WITH OIL. BEGAN WORKING AMDS WOEKSDR DALA2023052304113Unknown · unknownDTA ER/A 584898-14 REV D MONITOR INSPECTION LOG REFERENCE REQUIRES 3RD STAGE DTA APPROVAL ON OR BEFORE NEXT 59000 CYCLES AFTER SECTION III. CONTACT LIAISON ENGINEERING, DEPT 555.ASSOCIATED ER/A 00-584898 ADDED FOR AC 3039. (LP# 2772175)SDR DALA2022111807444None · noneER/A 584898-14 HAS BEEN REVISED TO 'C' DOCUMENTING THE SECTION I II PERMANENT REPAIR PERFORMED DURING CCK IN MCI. FOLLOW ON ACTIO N IS REQUIRED. SECTION III IS LIMITED TO 6 MONTHS (182 DAYS) FROM 17NOV22. ER/A TO BE REVISED INCORPORATING DAMAGE TOLERANCE EVALUSDR DALA2022111407330Light · brokenEPL ASSY BROKEN AT PASSENGER SEAT# 11C, 14C, 17C, 19C, 20C, 23C. EPL ASSY REPLACED AT PASSENGER SEAT# 11C, 14C, 17C, 19C, 20C, 23C, IAW CMM 25-21-52. (LP# 2492120)SDR DALA2022052303536None · noneFL CTL FLAPS LOCKED CAUTION MSG IN FLT. DUE TO FAILURE MSG FLP LH PROX SNSR 2 39CVM OPERATED FLAPS CONFIRMED FAULT REMOVED AND REPLACED PROX SENSOR OF THE INTERCONNECT STRUT PER 321AMM 27-51-44-400-002-A OPS CK GOOD NO FAULTS (S. LAMI 447515) LEFT INTERCONNECTSDR DALA2022020900864None · noneWHEN L1 DOOR IS LOCKED AND CLOSED CB P10 & P11 TRIP. TROUBLE SHOT, FOUND DAMAGED L1 DOOR 'ARM SLIDE' LIGHT HARNESS . REPLACED L1 DOOR 'ARM SLIDE' LIGHT / HARNESS ASSEMBLY. OPS CHECK GOOD PER A321 AMM 52-73-21-000-001-A AND 52-73-21-400-001-A. CIRCUIT BREAKS P1SDR DALA2019111216586Cover · missingAFT LEFT DOOR EMERGENCY LIGHT COVER MISSING, INSTALLED AFT LEFT DOOR EMERGENCY LIGHT COVERSDR DALA2019102856216Battery Pack · faultedEMERGENCY LIGHT CHECK - EPSU AFT LEFT BATT FAULT, REPLACED EPSU 13WL BATTERYSDR DALA2019101305870Battery Pack · inoperativeON SVC CHECK PERFORMED EPSU TEST RECEIVED CLASS 1 BAT/EPSU(15WL) MID L FAULT, REPLACED EPSU BATTERY FIN 15WLSDR DALA2019050202879Epsu · inoperativeDURING EMER LIGHT TEST, L1 SLIDE LT FAILED ESCAPE SLIDE LIGHTING, REPLACED EPSU AND BATTERY.SDR DALA2019041762513Light · damagedEMERGENCY LIGHT DAMAGED AT 12C, RE ATTACHED ASSY TO SHROUDSDR DALA2018121907291Battery · faultedRCVD FAULT FOR EPSU 10WL, REPLACED 10WL BATTERY