N344NB
Service difficulty reports · 212
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N344NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N344NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024062506460Inlet · contaminatedDIRTY SOCK SMELL REPORTED BY OUT BOUND CREW. APU OIL FOUNDIN APU INLET. WORK CARDS 0550-2002, 4900-2001, 2100 -2003 ACS DECON STAGES 1&2 COMPLETE. NO ADDITIONAL SMELLS. APU REPLACED IAW AMM 49-01.SDR DALA2024051705300Unknown · odorSHIP 3144 DIRTY SOCK SMELL COMING FROKM TH A/C SYSTEM. CORRECTIVE ACTION: COMPLETED AMDS CARD 4900-2001. ALSO C/W AMDS W/C'S 0550-2002 & 0550 -9001-A320FAM. (5351164)SDR DALA2024042904758Apu · leakingDIRTY SOCK SMELL ON DESCENT. C/W AMDS W/C 0550-2002. SOURCE OF SMELL IS FROM APU. DURING INSPECTION FOUND LEAK AT LUBE PUMP PLATE SEAL. REMOVED AND REPLACED PLATE SEAL REF AMM 49-91.SDR DALA2024032203645Skin · damagedSHIP 3144 DAMAGE TO RIGHT HAND OUTBRD FLAP TRAILING EDGE. CORRECTIVE ACTION: RIGHT HAND OUTBOARD FLAP TRAILING EDGE REPAIRED PER A319 SRM 57- 53-00-300-120. (5544854)SDR DALA2024013101405Unknown · odorSHIP 3144 SMELLED FUMES WHEN TURNING ON ENGINE ANTI ICE NEAR OR AT IDLE. CORRECTIVE ACTION: PERFORMED PACK BURN OUT AND REPLACED CABIN AIR FILTERS PER W/C 2100-2003. (4313595)SDR DALA2024011800753Brake · overheatedSHIP 3144 - ATO - AT 70KTS, DUE TO HOT BRAKE ECAM MESSAGE. #3 BRAKE REPORTED AT 410°C. CORRECTIVE ACTION: REPLACED #3 MLG BRAKE. OK FOR SERVICE. (4313562)SDR DALA2023081106578Unknown · unknownSHIP 3144 G-5 GALLEY WORKDECK TOP SKIN IS LIFTING. CORRECTIVE ACTION: REPAIRED G-5 GALLEY WORKDECK TOP SKIN PER AD 2022-24-05. (2911368)SDR DALA2023081106577Unknown · unknownSHIP 3144 AD NOTED DELAMINATION BOTTON OF THE GALLEY 511 5X11. CORRECTIVE ACTION: REPAIRED DELAMINATION AT BOTTOM OF THE GALLEY 511 5X11 PER AD 2022-24-05. (2911357)SDR DALA2023081106576Unknown · unknownSHIP 3144 AD RELATED INSIDE 510 TROLLEY AREA COMPARTMENT FOUND CRACK AND MEASURE .300. CORRECTIVE ACTION: REPLACED 510 TROLLEY AREA COMPARTMENT PER AD 2022-24-05. (2911378)SDR DALA2023081106575Unknown · unknownSHIP 3144 ON COMPARTMENT 510 FOUND DELAMINATION NOTED BOTTOM OF GALLEY 6X1. CORRECTIVE ACTION: REPAIRED DELAMINATION FOUND ON COMPARTMENT 510 NOTED BOTTOM OF GALLEY 6X11 PER AD 2022-24-05. (2911389)SDR DALA2023081106574Unknown · unknownSHIP 3144 AD NOTED DELAMINATION BOTTON OF GALLEY 512 11X4. CORRECTIVE ACTION: REPAIRED DELAMINATION BOTTOM OF GALLEY 512 PER AD 2022-24-05. (2911381)SDR DALA2023022001253None · noneAIRCRAFT 3144, STRONG FUME/ ODOR SMELL NOTICED AFTER TURNING APU AIR ON. FUMES/SMELL DISSIPATED AFTER APU AIR TURNED OFF. CORRECTIVE ACTION: REMOVED INSPECTED AND REINSTALLED SLEEVE DUCTS FORWARD OF BOTH OZONE FILTERS PER A-319 AMM 21-51-41. NEEDS LEAK CHECK. SDR DALA2023021901252None · noneAIRCRAFT 3144, ON DESCENT IN TO MSY A SLIGHT BURNING DEICE OR BURNING OIL SMELL WAS OBSERVED. CORRECTIVE ACTION: REPLACED O-RING ON GENERATOR DRAIN. (LP 4084569) PERFORMED AMDS CARD 2100-2005 REVERSE FLOW DECONTAMINATION. NO ODOR PRESENT. (LP 4084568)SDR DALA2022112807550Acm · failedAIR TURNBACK DUE TO METAL GRINDING SMELL IN CABIN AND FLIGHT DECK. REPLACED LEFT AIR CYCLE MACHINE. OPS CHECK GOOD.SDR DALA2022112207501Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED / LOCATIONS:29F. INSPECTED AND STOWED OXYGEN MASK AT SEAT 29F PER A319 AMM 35-21.SDR DALA2022112207500Oxygen Mask · unwanted deployOXYGEN PANEL MASK DEPLOYED / LOCATIONS:29E. INSPECTED AND STOWED OXYGEN MASK AT SEAT 29E PER A319 AMM 35-21.SDR DALA2022112207499Oxygen Mask · unwanted deploySHIP 3144 - OXYGEN PANEL MASK DEPLOYED / LOCATIONS:29D. INSPECTED AND STOWED OXYGEN MASK AT SEAT 29D PER A319 AMM 35-21.SDR DALA2022052403613None · noneSHIP 3144 - RIGHT MLG RETRACT ACTUATOR ANCHORAGE FITTING HAS CORROSION ON THE BORE AND FACES. CORRECTIVE ACTION: REPAIRED PER PRI 599631-14 REV. 0, ER/A 599631-14 REV. ORIGINAL. AND A319 SRM 57-26-13.(2246076)SDR DALA2022020200678None · noneSHIP 3144 - PSU UNIT ROW 14 D/E/F OPENED IN FLIGHT. CORRECTIVE ACTION: RESECURED MASKS/PANEL.( 8283351)SDR DALA2022012000423None · noneSHIP 3144 - FWD F/A SEAT O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21. (7869572)SDR DALA2022012000422None · noneSHIP 3144 - RH SEAT ROW 25 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21.(7869571)SDR DALA2022012000421None · noneSHIP 3144 - RH SEAT ROW 23 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21. (7869570)SDR DALA2022012000420None · noneSHIP 3144 - LH SEAT ROW 22 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21.(7869569)SDR DALA2022012000419None · noneSHIP 3144 - RH SEAT ROW 21 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21. (7869568)SDR DALA2022012000418None · noneSHIP 3144 - RH SEAT ROW 20 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21.(7869567)SDR DALA2022012000417None · noneSHIP 3144 - RH SEAT ROW 19 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21. (7869566)SDR DALA2022012000416None · noneSHIP 3144 - RH SEAT ROW 16 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21.(7869565)SDR DALA2022012000415None · noneSHIP 3144 - LH SEAT ROW 15 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: EPACKED THE MASKS PER A319 AMM 35-21. (7869564)SDR DALA2022012000414None · noneSHIP 3144 - LH SEAT ROW 13 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21.(7869563)SDR DALA2022012000413None · noneSHIP 3144 - RH SEAT ROW 11 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 AMM 35-21. (7869562)SDR DALA2022012000412None · noneSHIP 3144 - RH SEAT ROW 3 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER A319 35-21. (7869561)SDR DALA2022012000411None · noneSHIP 3144 - LH SEAT ROWS 11 O2 PANEL THAT DID NOT OPEN. CORRECTIVE ACTION: REPACKED THE MASKS PER AMM 35-21. (7869560)SDR DALA2021071203899Bottle · low pressureSHIP 3144 L1 DOOR ASSIST BOTTLE FOUND WITH 0 PSI. WOULD NOT HOLD PRESSURE. CORRECTIVE ACTION: R/R L1 DOOR ASSIST BOTTLE PER A319 AMM 52-11-14. (7366292)SDR DALA2021063003570Pressure Switch · leakingSHIP 3144 - HYD - AFTER LEVEL OFF, LOST GREEN SYS. ECAM "HYD G RSVR LO LVL". GRAVITY GEAR EXTEND REQUIRED PER QRH. CORRECTIVE ACTION: FOUND PACKING ON #1 ENG HYD EDP PRESSURE SWITCH LEAKING. REPLACED PACKING IAW A319 AMM 29-11. (7366244)SDR DALA2021042102337Fault Message · odorSHIP 3144 - AFTER T/O IN KATL GOT F/CTL ELAC 2 PITCH FAULT . ON LANDING AT KXTP GOT SAME FAULT AGAIN. ON RESET CAPTAIN SMELLS BURNING ELECTRICAL FUMES. CORRECTIVE ACTION: C/W NO GO ODI ATA 2172 W/C. NO DISCREPANCIES FOUND OR ODORS. AIRCRAFT OK FOR SERVICE.SDR DALA2021041902280Bottle · low pressureSHIP 3144 - FOUND LH1 DOOR ASSIST ACCUMULATOR REQUIRE RE-CHARGING. CORRECTIVE ACTION: PERFORMED SERVICING IAW A319 AMM TASK. (7652704)SDR DALA2021021100803Psu · no testSHIP 3144 DURING TEST PSU/O2 PANEL SEAT 16 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7494366)SDR DALA2021021100802Psu · no testSHIP 3144 DURING TEST PSU/O2 PANEL SEAT 27 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7494369)SDR DALA2021021100801Psu · no testSHIP 3144 DURING TEST PSU/O2 PANEL SEAT 23 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7494368)SDR DALA2021021100800Psu · no testSHIP 3144 DURING TEST PSU/O2 PANEL SEAT 19 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7494367)SDR DALA2020113003915Oxygen Mask · unwanted deploy25FED PAX 02 MASKS DROPPED. CORRECTIVE ACTION: RE-SECURED PSU DOOR AT PAX SEAT 25FED. NO FAULT NOTED. OK FOR SERVICE, PER A319/320 AMM 35-21.SDR DALA2020043002333Frame · damaged(AIRCRAFT 3144, L/P 1553789) DURING FRAME INSPECTION FOUND HOLE 2 @ FITTING 1 TO BE MEASURING 0.285 OUT OF LIMITS. REF. AMDS 5311-01216-08 STEP 17. AD RELATED ACTION REQUIRED PRIOR TO FURTHER FLIGHT. FR 68 RH SIDE. CORRECTIVE ACTION: REPAIRED PER ERA 586637-14SDR DALA2020043002332Frame · damaged(AIRCRAFT 3144, L/P 1553787) DURING FRAME INSPECTION FOUND HOLE 4 @ FITTING #1 TO BE MEASURING 0.285 OUT OF LIMITS REF. AMDS 5311-01216-08 STEP 17. AD RELATED ACTION REQUIRED PRIOR TO FURTHER FLIGHT. FR 68 RH SIDE. CORRECTIVE ACTION: REPAIRED PER ERA 586637-14SDR DALA2020043002331Fitting · damaged(AIRCRAFT 3144, L/P 1553780) EXISTING REPAIR FOUND AT FR68 RH SIDE LIAISON ENGINEERING EVALUATION AND DISPOSITION IS REQUIRED BEFORE FLIGHT. FITTING #1 HOLE #4. CORRECTIVE ACTION: REPAIRED PER ERA 586637-14AD REV. ORIGINAL, SECTION I.SDR DALA2020043002330Frame · damaged(AIRCRAFT 3144, L/P 1553784) DURING FRAME INSPECTION FOUND HOLE 3 FITTING 1 TO BE MEASURING 0.285 OUT OF LIMITS REF. AMDS 5311-01216-08 STEP 17. AD RELATED ACTION REQUIRED PRIOR TO FURTHER FLIGHT FR68 RH SIDE. CORRECTIVE ACTION: REPAIRED PER ERA 586637-14AD RESDR DALA2020043002334Frame · damaged(AIRCRAFT 3144, L/P 1550849) DURING FRAM INSPECTION FOUND HOLE 4 @ FITTING 4 TO BE MEASURING 0.2835, OUT OF LIMITS REF AMDS 5311-01216-08 STEP 17. AD RELATED, ACTION REQUIRED PRIOR TO FURTHER FLIGHT FR68 RH SIDE. CORRECTIVE ACTION: REPAIRED PER ER/A 586637-14ASDR DALA2020043002329Frame · damaged(AIRCRAFT 3144, L/P 1550847) DURING FRAME INSPECTION, FOUND HOLE 1 AT FITTING 7 TO BE MEASURING 0.285 AND OUT OF ROUND. OUT OF LIMITS REF AMDS 5311-01216-08 STEP 17. AD RELATED, ACTION REQUIRED PRIOR TO FURTHER FLIGHT. FR 68 RH SIDE. CORRECTIVE ACTION: REPAIRESDR DALA2019121607368Door · inflt separationPDA. PART DEPARTED AIRCRAFT. A/C 3144 CLOSED LOG 6089545 FLT/CHK 1426 PILOT REPORT. REFUEL PANEL DOOR BELLY FAIRING MOUNTED*** MISSING **** FWD TO CDL 28-00-02B. PERFORMANCE CORRECTIONS APPLY. PRIOR TO EACH DEPARTURE, VISUALLY INSPECT SPEED TAPE TO VERIFY THATSDR DALA2019092605541Sensor · contaminatedON TAKEOFF @MSP L/G DOORS NOT CLOSED UPON RETRACTION COMPLIED WITH ECAM RECYCLED GEAR SYS NORMAL. T/S PER TSM 32-31-00-810-815A. LGCIU 1 AND 2 TEST OK. BOTH GND SCAN NO FAULTS. REMOVED EXCESSIVE GREASE FROM SENSORS. TESTS OK. FWD TO "MON" FOR CHECK OF PFR AFTESDR DALA2019091905426Door Frame · crackedCRACK INDICATION ON FRAME 68 UPPER CORNER AFT FACE AT LEVEL STR 8L PASSENGER CREW DOOR CUTOUT APPROX L= 0.625IN AT AFT GALLEY AREA. REPAIR FRAME 68 UPPER CORNER AFT FACE AT LEVEL STR 8L PASSENGER CREW DOOR ASPER ER/A NR 580967-14AD SECTION 1 REV ORIGINAL AND A
Back to N344NB