N35271
Service difficulty reports · 47
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N35271' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N35271' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026091719495Light · damagedRT AFT EMERGENCY EXIT LIGHT APEARS TO HAVE A BROKEN BACKING PLATE. REMOVED EXIT LIGHT COVER. NEW PART IN AREA. REMOVED AND REPLACED RT AFT EMERGENCY EXIT LIGHT ASSY IAW AMM 33-51-01-960-802. OPS CHECKED GOOD.SDR CALA2026091519449Battery · faultedFLOOR PATH LIGHTS ROW 7- 14 INOP. BATTERY PACK AT 8 RIGHT. REPLACED FUSES. NEEDS CHARGER AND BATTERY REMOVED AND REPLACED EMERGENCY BATTERY PACK M1676 IAW BOEING 737-800 AMM 33-51-06-960-805. OPERATIONAL CHECK SATISFACTORY.SDR CALA2026091419418Battery Pack · no testEMERGENCY BATTERY PACK M1672 FAILED CAPACITY CHECK. REMOVED AND REPLACED EMERGENCY BATTERY PACK M1672 IAW AMM 33-51-06-960-805 OPS CHECK GOODSDR CALA2025111011100Girt Bar · no discrepancyPURSER REPORTED EXCESIVE SLIDE MATERIAL, ON R2 DOOR BOTTOM. INSPECTED SLIDE GIRT MATERIAL WITH NO DEFECTS NOTED, Z FOLD INTACT IAW AMM 25-66-01, OK FOR SERVICE.SDR CALA2025100709718Slide · partial deployOPS REPORTED PASSENGER ATTEMPTED TO OPEN R1 DOOR, PARTIAL SLIDE DEPLOYMENT. REMOVED R1 DOOR SLIDE DUE TO PARTIAL DEPLOYMENT REF UAL AMM 25-66-01-000-801. INSTALLED RIGHT FORWARD ESCAPE SLIDE (R1) PER REF AMM 25-66-01. INSPECTED INSTALL OF ESCAPE SLIDE (R1) ISDR CALA2025100709746Battery Pack · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EMERGENCY AISLE LIGHT NEAR SEAT 23 FED IS INOP. R & R BATTERY PACK, RIGHT AFT OVERWING SLIDE EMERGENCY LIGHT LAMP REPLACED, OPS CK GOOD, REF AMM TASK 33-51-04-960-801.SDR CALA2025100709745Battery Pack · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - EMERGENCY AISLE LIGHT NEAR SEAT 27 FED IS INOP. R & R BATTERY PACK, REMOVED AND REPLACED EMERGENCY AISLE LIGHT ASSY, REF AMM 33-51-03. OPS CK GOOD.SDR CALA2025100709744Power Supply · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. AFT RIGHT EMERGENCY SLIDE OVERWING LIGHT IS INOP. REMOVED & REPLACED EMERGANCY BATTERY AND POWER SUPPLY FOR M1671 REF AMM 33-51-06/201. OPS CHECK GOOD.SDR CALA2025081807894Bustle · damagedESCAPE SLIDE PACK BUSTLE DAMAGED DOOR 1L DOOR 1L SLIDE PROTRUDING FROM BOTTOM OF HOUSING. INSPECTED AND FOUND NO DAMAGE OR ISSUE WITH 1L DOOR SLIDE IAW AMM 25-66-01.SDR CALA2025081507846Windshield · delaminatedFOUND POSSIBLE DELAMINATION ON CAPTAIN`S NR 1 WINDOW, WINDOW DELAM IS OUTSIDE OF PILOT FIELD OF VIEW. NO IDICATION OF ARCING IS OCCURING. NO BUBBLES NOTED. MOISTURE IS PRESENT AT BUSS BAR. OK TO CARRY PER AMM 56-11-11 FOR 15 DAYS.SDR CALA2025071406520Engine · faultedRT ENG OVRHT LIGHT ILLUMINATED ON CLIMBINSPECTED CORE AREA OF #2 ENGINE FOUND CORE UPPER FIRE LOOP TOUCHING SENSE LINE TO PRSOV, ADJUSTED POSITION OF CLAMP, RAN ENGINE. OVERHEAT LIGHT CAME ON AFTER 3 MINUETS AT 85% N1, WENT OUT AFTER THROTTLE BACK TO 83%, THENSDR CALA2025053005116Oven · faultedFWD GALLEY OVEN2 GOT VERY HOT HAD BAD BURNING SMELL THAT WAS HOT TER THAN OVEN1 UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. MAC METER INITIATED FOR WITH VENDOR ID V951670 MAC RELATED WORK ORDER 0000000031382SDR CALA2025051604720Switch · false indicationFWD CARGO LIGHT ILLUMINATED ON APPROACH AT 1000 FT.EXTINGUISHED ON LANDING PLACED FRWD CARGO INDICATION ON MEL 5203D VERIFIED DOOR WAS CLOSED CHECH BEFORE EACH FLIGHT DISPATCH DESK: 3.APPROVED, FORWARD CARGO DOOR OPEN WARNING LIGHT INOPERATIVE PLACED ON MEL 52SDR CALA2025031302761Skin · damagedRE SKIN AFT CARGO DOOR (REF: AAR NR 1000033420) ESFR ENTRY ESFR COMPLETED AFT CARGO DOOR EXTERNAL SKIN REPLACEMENT INSPECTED BY VENDOR RII QUALIFIED INSPECTORS V947834 & V918045SDR CALA2025031202731Battery Pack · no testPASSENGER CABIN EMERGENCY LIGHTS, BATTERY PACK M1694 CAPACITY CH ECK FAILS (REF AAR NR 1000033377) BATTERY FAILED FUNCTIONAL CHECK DURING C CHECK IN RFD. REMOVED AND REPLACED BATTERY PACK M1694 IAW B737 AMM 33-51-06-96 0-805 AND PERFORMED OPERATIONAL TEST GOODSDR CALA2024121901585Slide · out of adjustSLIDE FOR DOOR 1R HAS PORTION DRAGGING ON THE FLOOR. ADJUSTED EXCESS DOOR SLIDE SKIRT, NO FURTHER DEFECTS NOTED AT THIS TIME. DOOR 1R OPERATES NORMALLY, A/C OK FOR RETURN TO SERVICE.SDR CALA2024071802060Computer · inoperativeGPWS INOP AND TERRAIN FAIL IN FLIGHT UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. INSTALLATION. SUSPECT BAD GPWC. GPWS IS HARD FAULTING MULTIPLE FAULT LIGHTS ON LRU. WILL NOT ADDING PART AND FLAGGING FOR CAT III SDR CALA2024051401473Modulating Valve · leakingNUMBER 4 WHEEL ASSEMBLY HYDRAULIC MODULATING VALVE APPEARS TO HAVE FLUID LEAKAGE.. PERFORMED LEAK CHECK NO ACTIVE LEAKS NOTED AT THIS TIME . OK TO CONTINUE . AMM 29-00-00-790-801SDR CALA2023081802567Control Panel · no testWX RADAR FAIL BOTH SIDES CONT STAB UPDATING WITH PICTURES FROM FLIGHT CREW IN ORDER OF OCCURANCE. FOUND WXR TEST FAILED, R+R WXR CONTROL PANEL. TEST PASSED. OPS CK GOOD. REF 737NG AMM 33-43-91.SDR CALA2022111703162Windshield · crackedFIRST OFFICERS FORWARD WINDSHIELD CRACKED ADDED PICS. REMOVED FIRST OFFICER #1 WINDOW..... REF AMM 56-11-11SDR CALA2022110703073Seal · missingPDA 3 AERODYNAMIC SEAL MISSING ON RT TRAILING EDGE FLAP O/B END. FOR RT O/B TRAILING EDGE FLAP O/B AERODYNAMIC SEAL. REMOVED AND REPLACED PDA3 AREODYNAMIC SEAL ON RT TRAILING EDGE FLAP O/B END. REF SRM 51-40-02.SDR CALA2022100302594Compensator · unserviceableSUSPECTED FUEL LEAK IN NO 1 ENGINE. WITH CENTER PUMPS ON FUEL WA S DROPPING IN BITE OF FQIS LAST LEG FAULTS SHOWS 28-41108= COMPENSATOR BAD. FOUND TANK #1 AT STICK #4 AT 9.2 AND FOUND #2 TANK AT STICK #5 VERIFIED FUEL DENSITY IS 6.76 WHICH IS WHAT THE CHARTS ASDR CALA2022080301950Stringer · corrodedAFT CARGO COMPT. UNDER FLOOR, STR 25L BETWEEN FS 827 AND 847 HAS MULTIPLE LOCATIONS WITH CORROSION IN CHANNEL REF TO PEMCO NR 12426.0919 REPAIRED STRINGER 25L AT AFT CARGO COMPT UNDER FLOOR BETWEEN STA 807-STA 910 PER B737-800 SRM 53-00-03-2R-1 CAT A. WORK PERSDR CALA2022022100471Panel · missingPDA 1 FOUND PANEL 193CR PARTIALLY MISSING AND DAMAGED ON WALK AROUND UPDATED WITH PICTURES PANEL REMOVED WITH PIC INSTALLED PANEL 193CR. REF AMM 53-51-21-400-802.SDR CALA2021081101316Transducer · inoperativeANTISKID INOP LIGHT LIGHT ON LIGHT IS INTERMITENT CREW REPORTED THAT THE ANTISKID INOP LIGHT CAME ON MOMENTARILY AT ABOUT 45 MINUTES INTO FLIGHT. AFTER THE LIGHT EXTINGUISHED IT DID NOT COME BACK ON THE REST OF THE FLIGHT. NO OTHER ISSUES REPORTED DURING CREW SDR CALA2020070401034Battery Pack · dischargedDOOR 1R EMERGENCY LIGHTS INOP T/S, FOUND BATTERY PACK BAD. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT R1 DOOR REF AMM 33-51-06-960-805. R1 EMERGENCY LIGHT OPS CHECKED GOOD.SDR CALA2019100701711Fairing · missingPDA 3 RIGHT ENG INBD T-R HINGE BUMP FAIRING IS COMPLETELY MISSING. REF IPC 78-31-51-19 ITEM 45 MFG P/N 315A2325-2SDR CALA2018010800104Light · inoperativeSEAT 38C EMERGENCY RED LIGHT INOPERATIVE ADJACENT TO MONUMENT. REPLACED THE LENS. EMERGENCY LIGHTS OPS CHECKED NORMAL.SDR CALA2018010800103Bulb · inoperativeAFT EMERGENCY EXIT, SEAT 15C RED LIGHT INOPERATIVE. REPLACED THE BULBS AND LENS. EMERGENCY LIGHTS OPS CHECKED NORMAL.SDR CALA2017111704120Light · brokenROW 20C EMERGENCY LIGHT BROKEN. REPLACED THE LIGHT ASSY.SDR CALA2017102003729Screw · backed outSLIDE PACK NOT SECURE AFT LEFT DOOR AFT 1/4 INCH MOUNT SCREW FOR SLIDE PACK BACKED OFF SEVERAL TURNS. RETIGHTENED, NO OTHER DISCREPANCIES OBSERVED.SDR CALA2017063002044Battery · inoperativeSEAT ROWS 15, 20, 21 AND LEFT WING DOOR EMREGENCY LIGHTS WILL NOT ILLUMINATE. REPLACED THE BATTERY PACK AND EMERGENCY LIGHTS OPS CHECKED GOODSDR CALA2016052300322Frame · damagedSTATION 344 FRAME AT RT WINDOW PLUG AREA HAS TWO EACH STANDOFFS DAMAGED. ALSO DAMAGED FRAME UNDER STANDOFFS. R & R TWO STANDOFFS & INSTALLED NEW STANDOFFS.SDR CALA2015051100386Engine · vibrationON CLIMB OUT, PASSING FL 350, NR 2 ENG VIBRATIONS JUMPED TO 5.0 WITH ACCOMPANYING NOISE & VIBRATIONS. LANDED WITH NR 2 AT IDLE, SHUTDOWN AFTER LANDING & SINGLE ENG TAXI TO GATE. REPLACED NR 2 ENG IAW MM 71-00-02 & TASK CARD 29-7100-1-0900. RAN ENG, ALL PARASDR CALA2015012700068Seat Track · crackedDURING NDT INSPECTION OF RT INBD FWD SEAT TRACK, FOUND CRACK INDICATION AT TWO EACH INBD FASTENER HOLES AT STATION 727B RBL 24.75. REMOVED DAMAGED AREA. FABRICATED & INSTALLED REPAIR IAW ECRA 5320-02400 REV ORIGINAL.SDR CALA2014052100640Light · inoperativeRIGHT AFT OVERHEAD EMERGENCY LIGHT INOPERATIVE. RELAMPED RT AFT OVERHEAD EMERGENCY AREA LIGHT IAW MM 33-51-03- 960-801. CHECKED GOOD.SDR CALA2013101500746Floor Support · crackedCABIN FLOOR SUPPORT BETWEEN STATION 344 & 360 ACFT CL IS CRACKED AT FLOOR ATTACHMENT HOLE INSTALLED INTERCOSTAL IAW SRM 51-40-02 & PRESERVED AREAS IAW SOPM 20-41-05SDR CALA2013101500745Floor Support · crackedFLOOR SUPPORT ANGLE CRACKED BETWEEN STATION 344 & 360 LBL 12 AT FLOOR ATTACH POINT. REPLACED FLOOR SUPPORT ANGLE INTERCOSTAL PN 141A5410U22 IAW 737 SRM 51-40-02 & DRAWING NR 141A5410 REV B. PRESERVED NEW ANGLE IAW SOPM 20-41-05SDR CALA2013091600668Control Valve · failedRT ENGINE BLEED TRIP AT 500 FT. QRH PROCEDURE P.20.5 FOLLOWED. AFTER RESET RT ENGINE BLEED TRIP OFF LIGHT ILLUMINATED. RT PACK PRESSURE DROPPED TO ZERO. TROUBLESHOT IAW FIM 36-10-00-810-801. FOUND PCCV AT FAULT, R & R IAW AMM 36-12-02. DURING TROUBLESHOOSDR CALA2012022100112Annular Filler · failedNR 2 ENGINE HAS HIGH VIBRATION. NR 2 ENG OIL PRESSURE FLUCTUATED. VIBRATION DECREASED AT IDLE TO 2.5, FOUND ANNULUS FILLER SEVERED IN HALF CAUSING ENGINE DAMAGE. REMOVED AND REPLACED NR 2 ENGINE IAW WC 29-7100-1-4900.SDR CALA2011071100478Skin · crackedSUPPORT TASK FOUND CRACK ON LEFT LOWER HORIZONTAL SKIN AT STA 129.5 9 INCHES FROM THE FWD SPAR ACCOMPLISHED PER ECRA 5510-02188 SEE 44.0008 REINSPECT AS PER SRM 55-10-01 REPAIR 11 INSPECTION THRESHOLD OF 56000 CYCLES AND EVERY 9000 CYCLES THEREAFTER REFERENCE SDR CALA2011071100477Skin · crackedSUPPORT TASK FOUND CRACK ON LEFT LOWER HORIZONTAL SKIN AT STA 1 38.70 25 INCHES FROM THE FWD SPAR. ACCOMPLISHED REPAIR AS PER ECRA 5510-02188 SE 44.0008. REINSPECT AS PER SRM 55-10-01 REPAIR 11 INSPECTION THREASHOLD OF 56000 FLT CYCLES AND EVERY 9000 CYCLE TSDR CALA2011071100476Frame · crackedSUPPORT TASK FOUND ON GV INSP OF EA 5310-04716 REV C OP 2 STEP 3.0 STRUCTURAL DAMAGE CRACK BETWEEN STR 8R AND STR 9R ON FRAME 480 RT. REPAIRED CRACK AT FRAME 480 RT BETWEEN STR 8R AND STR 9R IAW EA 5310-04716 REV C OP 2.SDR CALA2011070800470Frame · crackedSUPPORT TASK FOUND ON GENERAL VISUAL INSPECTION OF EA 5310- 04716 REV C OPS 2 STEP 3 STRUCTURE DAMAGE (CRACK ) BETWEEN STRINGER 8R & 9R. REPAIRED FRAME AT STA 440 RT PER EA 5310 04716 REV C OPS 2 FIG 3.SDR CALA2011070700468Frame · crackedSUPPORT TASK FOUND ON GV INSP OF EA 5310-04716 REV C OP 2 STEP 3.0 STRUCTURE DAMAGE CRACK BETWEEN STR 8R AND STR 9R ON FRAME 380 RT SIDE REPAIRED DAMAGE AT FRAME 380 RT SIDE PER EA 5310-04716 REV C FIG 3.SDR CALA2010051700202Power Supply · inoperativeAFT RIGHT EMERGENCY LIGHTS INOP. REMOVED AND REPLACED AFT M1672 EMERGENCY LIGHT POWER SUPPLY IAW 33-51-11 OPS CHECKED NORMAL.SDR CALA2010041900144Slide · out of limitsSLIDE PACK R-2 OUT OF LIMITS. REMOVED AND REPLACED R-2 SLIDE PACK IAW 25-66-01 400-803 RII C7020, ROTABLE PARTS CHANGE WAS INDICATED - TT 1385337, S/N OFF 02616 SLIDE, B737NG, OFF 29-2566-9-0003 2616, ON 29-2566-9-0004 2581.