N357NW
Service difficulty reports · 219
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N357NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N357NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015090405513Support · corrodedCORROSION ON WEB SUPPORT LOCATED AT LEVEL STR 23 AND BETWEEN FRAME 12 TO FR 1, RT SIDE AT FWD GALLEY AREA. REPLACED WEB SUPPORT LOCATED AT LEVEL STR 23R AND BETWEEN FRAME 12 TO FRAME 16 RT SIDE AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG.SDR DALA2015090405512Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 LOCATED BETWEEN FRAME 12 TO FRAME 16 MEASURE ARE L=1.100", W=0.850", D=0.020", APPROXIMATELY SSI 531189 AT FWD GALLEY AREA. REPLACED RAIL DUMMY Y503.02 LOCATION BETWEEN FRAME 12 TO FRAME 16 AT FWD GALLEY AREA IAW SRM 51-72-11 ANDSDR DALA2016112209106Stringer · corrodedSTRINGER 42L SHOWING SIGNS OF CORROSION BETWEEN FRAMES 56 AND 57. REPAIRED IAW ER/A.SDR DALA2016112209105Stringer · corrodedSTRINGER 43L SHOWING SIGNS OF CORROSION BETWEEN FRAMES 56 AND 57. REPAIRED IAW ER/A.SDR DALA14021453257Connector · disconnectedDURING A NON-ROUTINE CHECK, FOUND ROW 21, EMERGENCY LIGHT INOPERATIVE. MAINTENANCE FOUND CONNECTOR DISCONNECTED, RECONNECTED WIRES AND FUNCTIONAL CHECKED NORMAL.SDR DALA14021443257Connector · unsecureDURING A NON ROUTINE CHECK, FOUND ROW 22 SEAT EMERGENCY LIGHT INOPERATIVE. MAINTENANCE SECURED CONNECTOR, WIRES AND FUNCTIONAL CHECKED NORMAL.SDR DALA1510953257Structure · debondedRUDDER SIDE SHELL DISBONDED, INSPECTED AND REPAIRED.SDR DALA12005783257Connector · disconnectedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 19ABC INOPERATIVE. MAINTENANCE RECONNECTED ELECTRICAL CONNECTOR AND FUNCTIONAL TEST WAS NORMAL.SDR DALA1160773257Wire · brokenDURING NON ROUTINE CHECK, FOUND THE EMERGENCY EXIT PATH LIGHT AT ROW 15 INOPERATIVE. MAINTENANCE RECONNECTED BROKENWIRE AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1115473257Epsu · faultedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT SYS TEST FAULTS ESPU INTERNAL LOAD FOR SIGN 53L. MX REPLACED ESPU AND FUNCTIONAL TEST WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1102393257Wire · brokenDURING A NON ROUTINE CHECK, MX FOUND SEAT ROW 6C EMERGENCY PATH LIGHT INOPERATIVE. REPAIRED A BROKEN WIRE UNDER SEAT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1100573257Power Supply · faultedDURING NON-ROUTINE CHECK, FOUND THE EMERGENCY POWER SUPPLY UNIT FAULTED AT 10WL. MX REPLACED POWER SUPPLY UNIT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA109583257Light · no testDURING AN OVERNIGHT LINE CHECK, EMERGENCY EXIT LIGHT FAILED FAULT CHECK. MX REPLACED EPSU AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR NWAA094213257Sill · corrodedDURING M-CHECK FOUND CORROSION ON RT AFT PASSENGER DOOR SILL. REPAIRED PER EA 32-217251.SDR NWAA094183257Structure · gougedDURING M-CHECK FOUND GOUGE IN LT NR 3 WING SLAT TRAILING EDGE. REPAIRED PER EA 32-217250.SDR NWAA094203257Sill · corrodedDURING M-CHECK FOUND CORROSION ON RT AFT PASSENGER DOOR SILL PLATE UPPER ATTACHMENT FLANGE AT FR 66. REPAIRED PER EA 32-217252.SDR NWAA072383257Power Supply · inoperativeEMERGENCY ESCAPE LIGHTING EPSU 11WL INOP. REPLACED EPSU 11WL, OPERATIONAL CHECK OK.SDR NWAA072293257Power Supply · inoperativeTEST OF EMERGENCY LIGHT SYSTEM (CIDS) EPSU INT LOAD EMERG L DISPLAYED. REPLACED EPSU 11WL, TESTS OK..SDR 0100993257Slide · failedDURING AIRCRAFT EVACUATION FOLLOWING ABORTED TAKEOFF AND RUNWAY EXCURSION, THE SLIDE RAFT ASSEMBLY FAILED TO DEPLOY AT DOOR 2L.