N358NW
Service difficulty reports · 108
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N358NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N358NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2025080105794Wire · damagedATB DUE TO THE FLAPS BEING LOCKED BETWEEN POSITION 1 AND 2 WITH A FLAPS FAULT MESSAGE. REPLACED PIN ON WIRE 2751-5907R, REPLACED CONNECTOR 7505VC-B AND REPLACED PROX SENSOR 37CV.SDR DALA2025060204203Filter · odorSHIP 3258 DISC: ON CLIMBOUT SMELLED 'SEWAGE' SMELL THE DISSIPATED. REOCCUR SEVERAL TIMES TURNING INTO A MORE MUSTY SMELL AS THE FLIGHT PROGRESSED. CRUISE ALT FL320 ADDITIONAL INFO PAX IN 24 ABC ALSO SAID THEY SMELLED FUMES. C/A: SERVICED CREW O2 TO STABILIZED SDR DALA2025051603793Oven · odorSHIP 3258 DISC: FLT ATTN REPORTED OVEN SMELLED LIKE BURNING PLASTIC WENT AWAY WHEN TURNED OFF. C/A: FLT ATTENDENT STATED SHE SMELLED BURNING PLASTIC WHEN OVEN WAS RUNNING AFTER TURNED OFF NO SMELL. PERFORMED OPS TEST OF OVEN FOR 10 MINS FULL HEAT NO BURNING SMSDR DALA2025033002339Radome · damagedSHIP 3258 DISC: BIRD STRIKE RADOME, BIRD REMNANTS FOUND ON RIGHT ENGINE COWL AND ON BLADES. ALL ENGINE INDICATIONS NORMAL ON APPROACH. C/A: C/W BIRD STRIKE INSPECTION PER A320 AMM 05-51-14-200-803-A. FOUND NOSE RADOME DAMAGED BEYOND LIMITS. DA788048. R&R RADOMSDR DALA2025011000203Door · crackedSHIP 3258 DISC: R/H MLG DOOR CRACKED UNDER DOOR ACTUATOR ATTACH BRACKET. DOT 818 -031. C/A: OORDERED AND RECEIVED R/H MLG DOOR P/N: D5288016500700 IAW A320 AIPC 52-81-18-01 EVALUATED R/H MLG CRACK MEASURING 5' DAMAGE FOUND TO BE OUT OF LIMITS REQUIRE REPLACEMESDR DALA2025011000202Diaphragm · failedSHIP 3258 DISC: R2 DOOR ASSIST BOTTLE REQUIRES REPLACEMENT. C/A: REMOVED AND REPLACED R2 DOOR ASSIST BOTTLE DIAPHRAGM IAW A320 AMM 52-10-00-610-001-A JOB COMPLETE. (LP: 0742192)SDR DALA2025010600070Skin · damagedSHIP 3258 DISC: R/H WING #2 SLAT O/B END LWR SKIN DAMAGED (1.1/2 INCH LENGH HOLE ) DOT. (806.015). C/A: UPON FURTHER INSPECTION FOUND #2 SLAT O/B END LWR SKIN DAMAGE TO EXTEND INTO #3 SLAT. BOTH #2 END #3 SLAT SKIN DAMAGE FOUND TO BE OUT OF REPAIRABLE LIMITS. SDR DALA2024112711244Light · inoperativeSEATS 23 AND 28DEF EMERGENCY ESCAPE MOUNTED LIGHTS INOPERATIVE. REMOVED AND REPLACED CABIN EMERGENCY ESCAPE LIGHTS AT SEATS 23DEF AND 28DEF PER A 320 AMM 33-51. OPS GOOD. THIS CLEARS MEL 33-50-03A. PLACARDS REMOVED. (LP: 6570846)SDR DALA2024111810988Ecs · contaminatedSHIP 3258 DISC: DIRTY SOCK SMELL REPORTED BY AFT FLIGHT ATTENDANTS DURING PUSHBACK AND AFTER ENG START. C/A: NSP LOG BOOK FOR IRREGULAR OIL HYD CONSUMPTION TRENDS. NO FOUND PER W/C 0550-2002 FOUND DE-ICE FLUID AROUND APU INLET. PERFORMED W/C 2100-200 5DECOSDR DALA2024072907531Panel · looseSHIP 3258 DISC: OXYGEN PANEL LOOSE / LOCATIONS:5AF / ACARS TEXT: FRC3523025AF CREW O2 PANEL LOOSE ON AFT GALLEY... C/A: *** CONTRACT MAINTENANCE EVENT - OCM: 284732 *** SECURED AFT GALLEY OVERHEAD PANEL REF A320 AMM 25-25. OK FOR SERVICE. (LP: 0465148)SDR DALA2024072907530Panel · looseSHIP 3258 DISC: OXYGEN PANEL LOOSE / LOCATIONS:401 / MYCABIN TEXT: FRC352302401 2L ABOVE THE DOOR- FELL DOWN DURING TAKE OFF, DOESNT FULLY LATCH / INTERIOR. C/A: SECURED OXYGEN PANEL. OK FOR SERVICE. (LP: 0463480)SDR DALA2024072407435Buss Bar · damagedAT CRUISE F340 NOTICE FO'S SIDE WINDOW WAS HOT TO TOUCH DELAMINATING AND ACTIVELY BUBBLING ON BOTTOM CENTER OF WINDOW. SLIGHT PLASTIC SMELL NOTED A LITTLE LATER PULLED W14 PER QRH. C/A: INSP RT WINDOW PER A320 AMM 56-12-11-200-001-A. WINDOW HAS BURN MAKRS AND SDR DALA2024071307095Oxygen Mask · unwanted deploySHIP 3258 DISC: O2 MASK 21 A-B-C- DEPLOYED DURING TAKE OFF ROLL. C/A: STOWED MASKS AT SEAT 21ABC CKS OK REF A320 AMM 35-41. (LP: 6115112)SDR DALA2024060605811Unknown · odorFAS REPORTED BURNT POPCORN SMELL IN AFT GALLEY. SMELL DISSIPATED WHEN WE PULLED OVER TO INVESTIGATE. C/A: T/S PER TSM 05-50-00-810-831-A AND IDENTIFIED AS TYPE 10. NO ODORS PRESENT. NOTIFIED ATL MCC + NOPREVIOUS HISTORY. A/C OK FOR SERVICE.SDR DALA2024032003527Oxygen Mask · dislodgedSHIP 3258 DISC: RT AFT LAV O2 MASK FELL IN FLIGHT. C/A: *** CONTRACT MAINTENANCE EVENT - OCM: 278157 *** REINSTALLED MASK PER A320 AMM 35-21. AIRCRAFT OKAY FOR SERVICE. (LP: 5578072)SDR DALA2024031403323Unknown · odorSHIP 3258 DISC: MUSTY/"DIRTY SOCK" ODOR NOTED IN THE FLIGHT DECK WHEN FIRST ARRIVED AT A/C. C/A: OIL CAME OUT APU INLET DOOR. PERFORMED DECONTAMINATE THE ECS PER WORK CARD 2100-2005 STEP 1-6 SS 033611. COMPLETED WORK CARD 2100-2005 CABIN RECIRC FILTERS REPLACESDR DALA2024030503024Unknown · odorSHIP 3258 DISC: STRONG ODOR ON AIRCRAFT. C/A: T/S PER WORKCARD 0550-2002; FOUND APU LEAKING OIL AT APU INLET. REPLACED BOTH RECIRC FILTERS PER A320 AMM 21-21. NEED TO CLOSE FILTER ACCESS. JIP (148777). RECIRC FILTER ACCESS CLOSED. PERFORMED DECONTAMINATION PERSDR DALA2024020901768Oil System · leakingDHIP 3258 DISC: DESCENDING THROUGH 18,000, VERY STRONG DIRTY SOCK SMELL PRESENT IN FLIGHT DECK. GOT WORSE 12,000 - 8,000, DISSIPATED, THEN RETURNED DURING GLIDE SCOPE CAPTURE/ POWER ROLL BACK ON FINAL APPROACH. SMELL NOT PRESENT IN CABIN. REMOVED PLUGS S1 ANDSDR DALA2024020401518Oil System · leakingSTRONG WET SOCK ODOR ON DESCENT AT FLIGHT IDLE APPROACHING 10000 MSL TO THE GATE. ODOR DETECTED IN BOTH THE COCKPIT AND THE CABIN. C/W NO GO ODI CHECKLIST. FOUND OIL LEAK AROUND APU INLET. PERFORMED GVI OF L+R ENG W/ NO LEAKS NOTED. C/W W/C 2100-2005 UP TO STSDR DALA2024011800749None · noneSHIP 3258 DISC: COMPLY WITH ER/A 614993-14. REF BY AIRBORNE/PEMCO NR.14869.0036. C/A: C/W ALL STEPS OF PRI 614993-14 REV 01 AWAITING FINAL ERAJR 1604328 RECEIVED FIANL ERA 614993-14 AD REV O AND IT MATCHES PRI 614993-14 AD REV 01 ALLV WORK COMPLETED. PER SECTISDR DALA2024011800740Hinge · unknownSHIP 3258 DISC: ER/A 614993-14AD ISSUED FOR LH MLG DOOR FWD HINGE. FOLLOW ON ACTION IS REQUIRED. C/A: PERFORM SECTION II EVERY 7700FC AFTER SECTION I. ASSOCIATED ER/A 14-614993 ADDED FOR AC 3258. (LP: 0156105")SDR DALA2023122110473Unknown · unknownSHIP 3258 DISC: AFT R/H CABIN O2 MASK DOOR OPENED ON LANDING/TAXI IN AT AFT R/H PASSENGER DOOR. C/A: O2 GENERATOR PIN STILL SECURED. REPACKED MASKS AND RECLOSED DOOR . OK FOR SVC. REF A320 AMM 35-21. (LP: 4393858)SDR DALA2023121810356Unknown · unknownSHIP 3258 DISC: AMBER "FAN" ILLUMINATED IN COND PAGE. IN DESCENT. ASSOCIATED W/ MUSTY SMEL. C/A: RESET PER TSM 24-00. NO MORE FAULTS NOTED AT THIS TIME. A/C OK. (LP: 4393842)SDR DALA2023111609449Unknown · unknownSHIP 3258 DISC: RIGHT AFT EMERGENCY ESCAPE SLIDE/RAFT FAILS INSTALLATION TEST. C/A: RIGHT AFT DOOR EMERGENCY ESCAPE SLIDE/RAFT REMOVED PER AMDS CARD 2561-4002-RA. WIP 145099. INSTALLED SLIDE PER CARD 25-61-4007- (LP: 4600857)SDR DALA2023111309313Unknown · unknownSHIP 3258 DISC: ON INTO DTW NOTICED DIRTY SOCK SMELL. C/A: APU IDENTIFIED AS SOURCE OF SMELL DUE TO OIL LEAK. C/W AMDS W/C 7900-2001,4900-2001. W/C'S 2100-2005 AND 0550-2002 IN WORK. NO SMELL AFTER PACK BURN. (WIP 854413 KR) COMPLETED W/C'S 2100-2005 AND 0550-SDR DALA2023111009263Unknown · unknownSGUP3258 DISC:PAX IN COMFORT PLUS COMPLAINT OF NAUSEATING SMELL CABIN-TWO PAX GOT SICK- C/A: SMELL DESCRIBED AS COMING FROM LAVS. FLUSHED ALL LAVS SEVERAL TIMES, RAN BOTH PACKS FOR 10 MINUTES NO SMELL NOTED AT THIS TIME . A/C OK FOR SERVICE. (LP: 4600837)SDR DALA2023110709187Unknown · unknownSHIP3258 DISC: ROW 19 ABC O2 MASK + DOOR ARE OPEN C/A: RESTOWED OXYGEN MASKS PER A320 AMM 35-21-43, A/C OK FOR SERVICE.(LP: 4600814)SDR DALA2023110709186Unknown · unknownSHIP 325 DISC: PAX SEAT 31ABC INOP DUE TO PASSENGER OXYGEN MODULES DROP TEST FAILED. C/A: R/R 31ABC OXYGEN CONTAINER PER A321 AMM 35-21. ALL CONTAINERS PASSED DROP TEST. M PROC REVERSED. MEL/PLAC REMOVED. OK FOR SVC (LP: 4600813)SDR DALA2023110809209Unknown · unknownSHIP 3258 DISC: F/C LAV OXYGEN MASKS FELL AND FA REPORTED ONE WAS ACTIVATED. C/A: R/R OXYGEN ASSY CONTAINER PER A320 AMM 35-21 AND 35-23 CKS GOOD.(LP: 0045195)SDR DALA2023110809210Unknown · unknownSHIP 3258 DISC: DURING CHECK AFT MIDDLE LAV OXYGEN DROPPED AND WOULD NOT STOW C/A: R&R LAV OXYGEN ASSY PER A320 AMM 35-21-41. CHECKS GOOD. (LP: 4346791)SDR DALA2023062705170Unknown · unknownSHIP 3258 - DIV - TO ATL DUE TO ENGINE BLEED AIR SUPPLY FAULTS ON BOTH ENGINES. CORRECTIVE ACTION: REPLACED ENGINE 1 PRV AND SENSE LINE 1674GM AND ENGINE 2 PRV. ENGINE RUN GOOD. OK FOR SERVICE. (4981117)SDR DALA2022070104596None · noneSHIP 3258 EMERGENCY ESCAPE PATH LIGHT AT FWD CLOSET IS DAMAGED/INOP. CORRECTIVE ACTION: R/R LIGHT ASSY PER A320 AMM 33-52. OPS CHECK GOOD. (9187985)SDR DALA2022060603917Power Supply · inoperativeSHIP 3258 OVERHEAD EMERGENCY LIGHT OVER ROW 31 INOP. CORRECTIVE ACTION: REMOVED AND REPLACED POWER SUPPLY 13WL PER A320 AMM 33-51-38. OPS CHECK GOOD. (8819476)SDR DALA2022051103276Wire Harness · unsecureSHIP 3258 EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE AT SEAT 30D. CORRECTIVE ACTION: SECURED WIRE HARNESS. OPS CHECK GOOD. (2229038)SDR DALA2021122808089None · noneSHIP 3258 RH CONTINUITY FITTING WITH CRACK ON THE WINDSHIELD CENTER LOWER AREA. CORRECTIVE ACTION: REPAIRED PER PRI 595322-14 REV 1, ER/A 595322-14AD REV. ORIGINAL. (2066102)SDR DALA2021122808088None · noneSHIP 3258 LH CONTINUITY FITTING WITH CRACK ON THE WINDSHIELD CENTER LOWER POST. CORRECTIVE ACTION: FITTING REPLACED PER PRI 595322-14 REV. 1, ER/A 595322-14AD REV ORIGINAL AND RDAF 80982412/003/2021#A. (2066087)SDR DALA2021122808087None · noneSHIP 3258 LH WINDSHIELD SIDE POST AT FR 4 UPPER ATTACHMENT CRACK INDICATION OPEN HOLE. CORRECTIVE ACTION: REPLACED PER PRI 595321-14 REV 1, ER/A 595321-14AD REV. ORIGINAL. (2066077)SDR DALA2021122808086None · noneSHIP 3258 WINDSHIELD CENTER POST LOWER ATTACHMENT CRACK INDICATION ON LEFT VERTICAL SIDE UPPER FASTENER HOLE. CORRECTIVE ACTION: REPLACED PER PRI 595321-14 REV 1, ER/A 595321-14AD REV. ORIGINAL. (2066075)SDR DALA2021122808085None · noneSHIP 3258 WINDSHIELD CENTER POST LOWER ATTACHMENT CRACK INDICATION ON RIGHT VERTICAL SIDE UPPER FASTENER HOLE. CORRECTIVE ACTION: REPLACED PER PRI 595321-14 REV 1, ER/A 595321-14AD REV. ORIGINAL. (2066059)SDR DALA2021122708049None · noneSHIP 3258 ENG 1 FIRE EXTINGUISHER BOTTLE DISCHARGED. CORRECTIVE ACTION: FIRE EXTINGUISHER BOTTLE REPLACED PER A320 AMM 26-21-41. (2065336)SDR DALA2021122207984None · noneSHIP 3258 CRACK INDICATIONS FOUND IN RH AND LH CONTINTUITY FITTINGS, RH & LH FRONT WINDSHIELD, LWR POST CONNECTION. CORRECTIVE ACTION: COMPLIED WITH ER/A 595322-14AD. (2060017)SDR DALA2021122007884None · noneSHIP 3258 CRACK INDICATIONS FOUND IN RH AND LH CONTINTUITY FITTINGS, RH & LH FRONT WINDSHIELD, LWR POST CONNECTION. CORRECTIVE ACTION: COMPLIED WITH ERA 595321-14AD. (2055519)SDR DALA2021121307687None · noneSHIP 3258 CRACK IN HOLE #2, (1) CRACK IN HOLE #3 - FR16 LHS CROSSBEAM SPLICE AREA. CORRECTIVE ACTION: COMPLIED WITH ER/A 32-595130. (2047485)SDR DALA2021121307697None · noneSHIP 3258 WHILE ACCOMPLISHING INSPECTIONS PER EM 5311-01221-04 A CRACK FOUND IN HOLE #3, FR16 RHS CROSS BEAM SPLICE AREA. CORRECTIVE ACTION: COMPLIED WITH 595130-14AD. (2047572)SDR DALA2021120607498None · noneSHIP 3258 FR43 RH FRAME FOOT COUPLING NEEDS TO BE REPLACED PER AMDS CARD 5311-01239-02B. CORRECTIVE ACTION: REPLACED FRAME PER DELTA WORK CARD AMDS 5311-01239-02B. (2040525)SDR DALA2021060102978Skin · wornSHIP 3258 WEAR ON UPPER SKIN SLAT 1 LOC.AT SLAT TRACK 2 AREA ON LH WING. CORRECTIVE ACTION: PERFORMED REPAIR PER ERA 591780-14 REV. ORIGINAL AND PRI 591780-14 REV 0 AND 1. (1824037)SDR DALA2021040702047Psu · inoperativeSHIP 3258 ROW 19 ABC PSU INOP, PASSENGER OXYGEN. CORRECTIVE ACTION: R/R OXYGEN PSU AT ROW 19ABC IAW A320 AMM 35-21. PERFORMED OPS TEST OF THE EMERGENCY OXYGEN SYSTEM IAW A320 AMM 35-23. OK FOR SVC. (7589946)SDR DALA2021021100808Psu · no testSHIP 3258 DURING TEST FOUND PSU OXY PANEL FOR SEAT 26ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7694752)SDR DALA2021021100807Psu · no testSHIP 3258 DURING TEST FOUND PSU OXY PANEL FOR SEAT 17DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7694751)SDR DALA2021021100806Psu · no testSHIP 3258 DURING TEST FOUND PSU OXY PANEL FOR SEAT 4AB DID NOT OPEN. CORRECTIVE ACTION: REPACKED MASKS. OK FOR SERVICE. (7694750)
Back to N358NW