N359NW
Service difficulty reports · 192
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N359NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N359NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2015101906238Profile · crackedCRACK ON LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 FWD SIDE IN PASSENGER CABIN. REPLACED LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 FWD SIDE IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG: D52279048.SDR DALA2015101906237Profile · crackedCRACK ON LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 AFT SIDE IN PASSENGER CABIN. REPLACED LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 AFT SIDE IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG D52279040.SDR DALA2015101806236Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y765 FRAME 16 AT FWD GALLEY AREA. REPLACED FLOOR SUPPORT BETWEEN FRAMES 12 TO 24 IAW SRM 51-72-11, DWGS D53110920, D53112813 AND D53110984.SDR DALA2015101806235Shear Tie · corrodedCORROSION ON CLEAT FRAME 27 IN FWD CARGO BAY BETWEEN STR 41L TO STR 42L. REPLACED CLEAT IAW SRM 51-72-11 AND DWG D53231712.SDR DALA2015101806234Cleat · corrodedCORROSION ON CLEAT FRAME 27 IN FWD CARGO BAY BETWEEN STR 40L TO STR 41L. REPLACED THE CLEAT IAW SRM 51-72-11, DWG D53231712, AND D53230324.SDR DALA2015101506164Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1225, FRAMES 66+5 - 67+15. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472845.SDR DALA2015101506163Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1162, FRAMES 67+15 - 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015101506162Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y1225, FRAMES 66+5 - 67+15. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015101506161Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 FRAMES 67+15" - 69. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472800.SDR DALA2015101506160Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1292 FRAME 16. REPLACED THE FLOOR SUPPORT BETWEEN FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53112812 AND D53110984.SDR DALA2015101406120Floorbeam · corrodedCORROSION ON FLOORBEAM, -Y189, FRAME 20. REPLACED THE FLOORBEAM IAW SRM 51-72-11 AND DWG D53111406.SDR DALA2015101406119Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y465 FROM FRAMES 64 TO 67+10. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015101406118Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 AT AFT GALLEY AREA TO STR 23L. REPLACED THE FITTING IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2015101306080Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 LOCATED AT LEVEL FRAME 15+8" AT FWD GALLEY AREA, SSI 531189. REPLACED RAIL DUMMY Y503.2 LOCATED AT LEVEL FRAME 12 TO FRAME 16 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53110984.SDR DALA2015101306081Floor Support · corrodedCORROSION ON FLOORBEAM -Y1292 AT FWD GALLEY AREA BETWEEN FRAME 16 TO FRAME 24. REPLACED FLOORBEAM -Y1292 AT FWD GALLEY AREA LOCATED BETWEEN FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWGS D53110900, D53110984 AND DWG D53112812.SDR DALA2015101206076Fitting · corrodedCORROSION ON CORNER FITTING FRAME 16 LT SIDE AT FWD GALLEY AREA L=1.000", W=0.500" D=0.002". REPLACED CORNER FITTING LOCATION, FR 16 LT SIDE AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112225.SDR DALA2015092205776Power Supply · inoperativeLEFT EPSU INOPERATIVE. R & R LEFT EPSU IAW AMM 33-50 AND OPS CHECK WAS NORMAL.SDR DALA2016112209094Stringer · corrodedCORROSION FOUND ON STRINGER 43L BETWEEN FRAMES 53 AND 61. REMOVED AND REPLACED THE STRINGER IAW SRM.SDR DALA1515363259Stringer · corrodedSTRINGER 42L CORRODED BETWEEN FRAME 56 AND 57, REPAIRED IAW LOG 1933157.SDR DALA2015021701270Battery Pack · inoperativeDURING NON ROUTINE CHECK, FOUND EPSU INTERNAL LOAD FAULT RT. REPLACED EPSU BATTERY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA13057803259Battery Pack · inoperativeDURING CHECK, FOUND AFT LEFT EMERGENCY LIGHT POWER SUPPLY WITH A FAULT MESSAGE. MAINTENANCE REPLACED POWER SUPPLY BATTERY AND CHECKED NORMAL.SDR DALA1155373259Splice · damagedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT ROW 5 INOPERATIVE. MAINTENANCE INSTALLED NEW SODERLESS SPLICE AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA1051913259Battery Pack · inoperativeDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT AT 10WL INOPERATIVE. MX REPLACED THE BATTERY PACK AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURN TO SERVICE.SDR DALA1022033259Connector · looseEMERGENCY LIGHT TEST FAILED EPSU AFT LT, CONNECTOR RESEATED AND TESTS OK.SDR DALA1016143259Connector · looseDURING A NON ROUTINE CHECK, MAINTENANCE FOUND SEAT ROW 23 EMERGENCY PATH LIGHT INOPERATIVE. RE-SECURED A LOOSE CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA102253259Floor Panel · delaminatedDURING "M" CHECK FOUND MAIN CABIN FLOOR PANEL NR 241MF DELAMINATED. REMOVED AND REPLACED FLOOR PANEL.SDR DALA101063259Seat Track · corrodedDURING "M" CHECK FOUND CORROSION ON SEAT TRACK AT Y1292 BETWEEN FR 68 AND FR 69. REPAIRED IAW SRM 51-42-11.SDR DALA101053259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON LT FLOOR SUPPORT AT Y1732 BETWEEN FR 69 AND FR 70. REPAIRED IAW SRM 51-42-11.SDR DALA101043259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT AT Y1292 BETWEEN FR 66 AND FR 68. REPAIRED IAW SRM 51-42-11.SDR DALA101033259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON CABIN FLOOR SUPPORT AT Y1292 ABOVE FR 66. REPAIRED IAW SRM 51-42-11.SDR DALA101023259Sill · corrodedDURING "M" CHECK FOUND CORROSION ON SILL AT DOOR 2R. REPAIRED IAW SRM 51-42-11.SDR DALA101013259Sill · corrodedDURING "M" CHECK FOUND CORROSION ON LT AFT PASSENGER DOOR SILL. REPAIRED IAW SRM. 51-42-11.SDR DALA101003259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON RT FLOOR SUPPORT BETWEEN FR 69 AND FR 70. REPAIRED IAW SRM 51-44-11 AND SRM 51-42-11.SDR DALA100993259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT BETWEEN FR 65 AND FR 66 Y732. REPAIRED IAW SRM 51-42-11.SDR DALA100943259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT AT Y1292. REPAIRED IAW SRM 51-44-11 AND SRM 51-42-11.SDR DALA100893259Floor Panel · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR PANEL 262FF. REPLACED IAW CARD 2500-6002.SDR DALA100293259Floor Panel · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR PANEL 262FF. REPLACED IAW CARD 2500-6002.SDR DALA100883259Floor Panel · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR PANEL 261FF. REPLACED FLOOR PANEL IAW CARD 2500-6002.SDR DALA100873259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT AT Y765 FWD OF FR66. REPAIRED IAW SRM 51-42-11.SDR DALA100863259Floorbeam · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y765 FR66-FR70. REPAIRED IAW SRM 51-44-11.SDR DALA100633259Floor Support · corrodedDURING "M" CHECK FOUND CORROSION ON FLOOR SUPPORT AT FRAME 20 Y189. REPAIRED IAW SRM 51-42-11.SDR 0501683259Hydraulic Line · leakingINBOUND, CREW REPORTED A TOTAL LOSS OF THE GREEN HYDRAULIC SYSTEM FLUID. EMERGENCY DECLARED DUE TO LOSS OF NOSE WHEEL STEERING. MAINTENANCE DISCOVERED A HYDRAULIC RIGID PRESSURE LINE IN NR 1 PYLON LEAKING. LOG PAGE INDICATES LEAK CAUSED BY CLAMP. TEMPORARI
Back to N359NW