N360HA
Service difficulty reports · 112
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N360HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N360HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HALA20251007306Actuator · leakingETOPS, FOUND NR 1 ENG INBOUND + OUTBOARD C -DUCT OPENING ACTUATORS LEAKING OIL. REMOVED AND REPLACED INBOUND AND OUTBOARD ELBOW UNION SEALS ON #1 ENG PER AMM 78-36-42. OPS AND LEAK CHECK GOOD. OK FOR SVC.SDR HALA20251006302Elec Connector · damagedETOPS - DURING INSTALLATION OF #1 ENGINE , S/N:42338 FOUND CONNECTOR PLUG 3822 VC-A UNABLE TO THREAD COMPLETELY ON TO 3822VC(PYLON SIDE). REMOVED AND REPLACED ENG1 CONNECTOR 3822VC-A PER AMM 70-71-20. OPS CHECK PENDING. PERFORMED OPS TEST OF ENGINE FIRE AND OVSDR HALA20250721227Latch · unsecureATB - DOOR AVIONIC UNABLE TO MAINTAIN CABIN ALTITUDE. PRESSURIZED AC PER AMM 05-53-00-780-803-A NO LEAKS NOTED. CHECKED CLEARANCE ON AVIONICS DOOR PER AMM 52-41-11-400-801-A. CHECKS GOOD. FOUND LATCH ON DOOR NOT FULLY SECURED. CLOSE DOOR PER AMM 52-41-00. OPS SDR HALA20250630202Elec Connector · damagedETOPS - ENG #1 EEC CONNECTOR J9 PIN DAMAGED. REMOVED AND REPLACED ENG #1 J9 CONNECTOR PER AMM 70-71-20. ENG RUN OPS CHECK PENDING. ACCOMPLISHED #1 ENG IDLE RUN PER AMM 71-00-00-860-810-A. ALL CHECKS GOOD NO FAULTS NOTEDSDR HALA20250519138Valve · faultedETOPS - TEMP AT AFT CABIN STAYED AT 84 DEGREES F THROUGHOUT THE FLIGHT. CHANGES TO THE TEMP SETTING HAD NO EFFECT. REMOVED AND REPLACED TRIM AIR VALVE PER AMM 21-63-51. OPS + LEAK CHECK GOOD. OK FOR SERVICE.SDR HALA20250516136Filter · trippedETOPS - FOUND #2 ENG GREEN HYD EDP CASE DRAIN FILTER RED BUTTON EXTENDED. REMOVED AND REPLACED ENGINE -PUMP CASE DRASIN FILTER ASSY PER AMM 29-11-43-400-807-A.OPS CHECK AND LEAK CHECKS GOOD.OK FOR SERVICED.SDR HALA20250127039Fuel Line · leakingETOPS - #1 ENG FUEL LEAK (AFT PYLON DRAIN). FOUND LEAK @ PIPE PN A281500400200 CONNECTION. REMOVED PIPE. REPLACED PACKINGS & REINSTALLED PIPE PER AMM 28-00-00-400-801-A. LEAK CHECK OKSDR HALA20250109013Pump · leakingETOPS - DURING WALKAROUND, FOUND #2 ENG GREEN SYS EDP LEAKING. REMOVED AND REPLACED #2 ENG GREEN EDP PER AMM 29-11-51. OPS AND LEAK CHECK GOOD. OK FOR SERVICE.SDR HALA20241203348Chip Detector · false indicationETOPS - AFTER LANDING ECAM ENG 1 OIL CHIP DETECTED. INSPECTED ENGINE #1 MCD PER AMM 79-00-00-200-806-A. FOUND NO EVIDENCE OF CONTAMINATION. REMOVED & REPLACED EMCD PER AMM 79-22-46-000-811-A. TEST PASS.SDR HALA20241115325Drain Mast · leakingETOPS-ON PDC FOUND #2 ENG LEAKING FUEL FROM DRAIN MAST. REMOVED AND REPLACED FUEL DRAIN TANK EJECTOR PER AMM 71-71-42. LEAK STOPPED. OK FOR SVC.SDR HALA20241114324Igniter · failedETOPS-SMI 537252 - CREW PLACARD #2 ENG IGN B FAULT (IGNITION SYSTEMS B). REMOVED AND REPLACED #2 ENG IGNITER B REF AMM 74-21-51. OPS TEST GOOD. OK FOR SERVICE. MIC SHEET CLEARED. PLACARD REMOVEDSDR HALA20241105314None · no discrepancyOTHER - BIRDSTRIKE ON TAKEOFF OGG MULTIPLE BIRDS, DIV TO HNL. PERFORMED INSPECTION OF BIRDSTRIKE PER AMM 05-51-14-200-803-A. NO DAMAGE NOTED ON A/C. NO EVIDENCE ON BIRDSTRIKE NOTED. OPS TES OF FLIGHT CONTOLS GOOD. A/C IS OKAY FOR SVC.SDR HALA20241104309Oil System · leakingETOPS - DIRTY SOCK SMELL DURING DESCENT 5000FT. POWER IDLE, LASTED 1 MINUTE. PERFORMED TSM 21-00-00-810-801-A. NO OIL LEAK FOUND FROM APU. ALSO PERFORMED TSM 71-00-81-810-805-A NO OIL LEAKS NOTED FROM BOTH #1/#2 ENG. PERFORMED LEVEL A DECON. OF ECS PER AMM 21-SDR HALA20240926170Idg · warning messageETOPS - IDG #1 OIL LO ALERT ECAM ACTION PERFORMED. REMOVED AND REPLACED IDG LH. IAW TASK 24-21-51-000-804-A AND SERVICE IDG TASK 12-13-24-612-808A. OPS AND LEAK CHECK GOOD.SDR HALA20240923161Engine · making metalETOPS - ENG 1 OIL CHIP DETECTED ECAM AFTER SHUT DOWN. INSPECT #1 ENG. EMCD AND FOUND MINUTE QUANTITY OF FINES ON EMCD- LESS THAN HALF PROBE CIRCUMFERENCE. CLEANED & RE-INSTALLED EMCD PER AMM 79-00-00-200-822-A PAR. 4A(4)(B)1. OK FOR SVC.SDR HALA20240805211Warning Light · false activationETOPS - OIL CHIP ENG 1 DETECTED ON LANDING. PERFORMED TSM 79-20-00-810-823-A. NO DEFECTS NOTED. REMOVED, INSPECTED AND REPLACED SCAVENGE OIL FILTER PER AMM 79-00-00-200-821. NO DEFECTS NOTED. OPS/LEAK CHECK GOOD. OK FOR SVC.SDR HALA20240727198Transceiver · faultedETOPS - HF#2 DOE NOT TUNE, NO CHANNELIZING TONE AFTER SELECTED NEW ACTIVE FREQ. REPLACED HF#2 TRANSCEIVER PER AMM 23-11-33 BITE OKSDR HALA20240513131Thermostat · faultedETOPS - ON DESCENT # 2 PACK OVERHEAT ECAM DISPLAYED FOLLOWED BY ENG 2 BLEED FAULT ECAM. COMPLETED ECAM ACTIONS. PERFORMED TSM 36-11-81-861-AO1.REMOVED AND REPLACED #2 ENG FAN AIR VALVE CONROL THERMOSTAT (FIN 5HA2) PER AMM 36-11-43. OPS AND LEAK CHECK GOOD. OK SDR HALA20240424111Pcu · faultedETOPS - ECAM: ENG 2 MINOR FAULT DISPLAYED AFTER LANDING. TROUBLESHOOT PER TSM 73-21-89-810-811-A. LAST LEG FAULTING "DEDICTD ALTNR/PCU 22V A". REPLACED PCU REF AMM 73-21-35. OPS TEST GOOD. NO FAULTS NOTED. OK FOR SERVICE.SDR HALA20240422107Engine · multiple indETOPS - DURING HIGH POWER RUN, ENG 2 EXPERIENCED MULTIPLE FAULTS: IGNITION SUPPLY, LP SHAFT PROTECT LOSS, THRUST REVERSER , EPR MODE RECOVERABLE, ETC. REMOVED AND REPLACED EEC ON # 2 ENG PER AMM 73-21-34. CHECKS OKAY. PENDING CAT III LAND TEST. PERFORMED CAT ISDR HALA20240401080Circuit Breaker · failedETOPS - ELEC C/B TRIPPED ECAM DURING CLIMB OUT. ON C/B S.D PAGE :BLEED VLV ENG 2 T35. FOUND C/B FIN 3HA2 "T35" BAD. REPLACED PER AAWM 36-11-03 AND ESPM 20-46-10. BMC SYSTEM TEST OK PER AMM 36-11-00. ACCOMPLISHED #2 ENG RUN AND CYCLED BLEED SEVERAL TIMES. CHK OSDR HALA20240123027Control Unit · leakingOTHER - FOUND #1 ENG TR ISOLATION CONTROL UNIT LEAKING FROM REDUCER FITTING. FOUND REDUCER FITTING SEALS BROKEN. REPLACED #1 ENG TR ISOLATION CONTROL UNIT PER AMM 78-31-41.SDR HALA20230922203Unknown · unknownETOPS - BTB- AFTER START (ENGINES) DURING APU SHUTDOWN - APU FAULT ECAM DISPLAYED. MOC ADVISED RESTART APU - UPON RESTART APU FAULT RETURNED WITH AUTO SHUTDOWN. REMOVED AND REPLACED APU FUEL CONTROL UNIT PER AMM 49-32-51. REMOVED AND REPLACED APU ECB PER AMM 4SDR HALA2023081500173Coupler · faultyETOPS - HF 1 - FAILED TO TUNE 2HRS LATER. COM - SINGLE PTT STUCK. REMOVED AND REPLACED HF1 COUPLER (3RE1) PER AMM 23-11-36-400-801-A. HF TUNES. OPS CHECK GOOD. OK FOR SVC.SDR HALA2023080200165Unknown · unknownETOPS - AFTER TOUCHDOWN ECAM ENG 2 FGADEC SYSTEM FAULT. PERFORMED GROUND SCAN PROCEDURE PER TSM 73-21-00-740-808-A. TROUBLESHOOT HARNESS WIRE 4000KS1-JA9. FOUND WIRE CHAFING ON WIRE LOOP. REMOVED AND REPLACED EEC WIRE HARNESS 4000KSI-JA9 PER AMM 71-51-62-AND PSDR HALA2023062800137Unknown · unknownETOPS - WHILE PERFORMING TASK CARD FOUND HOLE IN APU SURGE CONTROL VALVE DUCT. REPLACED APU SURGE CONTROL VALVE DUCT IN ACCORDANCE WITH AMM 49-51-52. LEAK CHECK GOOD OPS CHECK GOOD. OK FOR SVCSDR HALA2023042400092Unknown · unknownATO - F/CTL PITCH TRIM/MCDU/CG DISAGREE. PERFORMED TSM 27-40-00-810-805. PERFORMED AFS BITE TEST PER AMM 22-96-00-740-801. TEST OK.SDR HALA2023040100013Unknown · unknownON TAXI IN HYD G RSVR LO LVL ECAM COMPLETED STOPPED A/C WITH PARKING BRAKE. FOUND RH GREEN RETURN HYDRAULIC HOSE LEAKING IN LANDING GEAR. REMOVED AND REPLACED HYDRAULIC HOSE ITEM 274 PER AMM 32-11-11-400-802-A. OPS AND LEAK CHECK GOOD. PERFORMED LEAK CHECK OF SDR HALA2022122300312Pressure Switch · faultedF/CTL ALTN LAW (PROTECT LOST) ON ECAM. HYD B ENG 1 PUMP LO PR AND HYD B SYS LO PR. BLOCK TURN BACK. REMOVED AND REPLACED ENG 1 B HYD PUMP PRESSURE SWITCH PER AMM 29-11-17 AND ENG 1 B HYD PUMP PER AMM 29-12-51-400-801-A. OPS CHECK AND LEAK CHECK GOOD. ENGINE RUSDR HALA2022072500134None · noneETOPS - HYD FLUID FOUND LEAKING OUT OF #2 ENG ON PREFLIGHT // FLUID LEAKING FROM PUMP SIDE OF UNION OF OUTLET LINE. R + R GREEN EDP PER A330 AMM 29-11. ALL OPS CHECK GOOD + NO LEAKS NOTED. 5JR CYCLED. A/C OK FOR SVC. PUMP, HYDRAULIC OFF 33-2912-9-0002 S/N SDR HALA2022052400185None · noneSHIP 360 3R CEILING EXIT SIGN INOP. CORRECTIVE ACTION: FOUND CONNECTOR LOOSE. RESECURED EXIT SIGN CONNECTION. (4955547)SDR HALA2022050500098None · noneETOPS - AFTER TAKEOFF ON AN APU VERIFICATION FLIGHT APU FAILED WITH NO ECAM MESSAGE ATIS TO SEA ACCOMPLISHED // C/W WITH NO GO ODI NO FAULTS ON APU RPLCD EXCITER & PLUGS AS PRECAUTION PER A330 AMM 49-41-38 & 49-41-41 CKS OK A/C OK FOR SVC EXCITER, IGNITI SDR HALA2022042800161None · noneSHIP 360 AFT GALLEY FLOORING W/FLOURESENT LIGHT STRIP PEELING UP. CORRECTIVE ACTION: SECURED FLOURECENT STRIPPING. (8458631)SDR HALA2022042700144Light · looseSHIP 360 FLOOR LIGHT STRIP COMING OFF OF THE TRACK POSITION 46/57 HJ. CORRECTIVE ACTION: RESECURED FLOOR LIGHT STRIP AT 46/47 HJ. (8458606)SDR HALA2022042100141None · noneSHIP 360 EMERGENCY LIGHT PATH STRIP COMING OFF NEAR SEAT 33H. CORRECTIVE ACTION: RESECURED EMERGENCY LIGHT PATH STRIP NEAR SEAT 33H. (8481171)SDR HALA2022041400137Light · inoperativeSHIP 360 EMERGENCY EXIT LIGHTS ILLUMINATED AFTER POWER TRANSFER AT THE GATE. RECYCLED TO OFF DIDN'T HELP . CORRECTIVE ACTION: CYCLED SWITCH FOR EMERGENCY EXIT LIGHT SYSTEM WORKS NORMAL. (8454679)SDR HALA2022041400136Light · inoperativeSHIP 360 EMER EXIT LIGHTS REMAIN ON WHEN IN THE ARM POSITION. CORRECTIVE ACTION: CYCLED / RESET EMER EXIT LIGHT SWITCH. COULD NOT DUPLICATE. CHECK OK. (8454669)SDR HALA2022041200090None · noneETOPS - ECAM ENG 1 CTL SYS FAULT DISPLAYED // EEC 1 CH B SHOWS "VSV SYSTEM/VSV CONTROL UNIT (E1-4081KS)" 753300 ON GROUND SCAN 04/11/22 2020495. REMOVED AND REPLACED VSV CONTROL UNIT PER AMM 75-33-51. OPS AND SECURITY CHECK GOOD. OK FOR SVC. NO FAULTS DISPLASDR HALA2022030100070None · noneSHIP 360 EMERGENCY LIGHTS REMAIN ON IN ARMED POSITION. CORRECTIVE ACTION: RESET CIDS AND EVAC RESET. OPS GOOD NO FAULTS. (8454417)SDR HALA2022022200052None · noneETOPS (IGNITER) - "B" IGNITER ON #2 ENG FAILED ON START - RESTART OK ON "AB" // REMOVED AND REPLACED #2 ENG "B" IGNITER PLUG. OPS CHECK AND SECURITY CHECK GOOD. REF AMM 74-21-51.SDR HALA2022021800050None · noneBTB ECAM ENG 2 START CNL FAULT AFTER #2 ENG START // REPLACED VSV CONTROL UNIT IAW AMM 75-33-51 OPS AND LEAK CK 2228794 OPS AND LEAK CHECK GOOD ACCOMPLISHED TEST 5 PER AMM 71-00-00-700-832-A CONTROL, VARIAB OFF 43-7533-9-0001 S/N 16025 ON 43-7533-9-0001 S/N SDR HALA2022021000037None · noneSHIP 360 SEAT TRACK AT FR55-59, -Y450 FOUND WITH MULTIPLE CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION IAW SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK IAW SRM 51-75-12-401. CARRIED OUTSDR HALA2022021000036None · noneSHIP 360 SEAT TRACK FROM FR 59-68, -Y450 FOUND WITH MULTIPLE CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION I.A.W SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK IAW SRM 51-75-12-401. CARRIESDR HALA2022021000057None · noneSHIP 360 SEAT TRACK FROM FR 47 - FR 53.2 Y1959 FOUND CORROSION. CORRECTIVE ACTION: CARRIED OUT INSPECTION FOUND CORROSION AT CROWN SURFACE AREA ALONG FRAME 52 AND 53.1 CARRIED UT REWORK AT SAID AREA IAW SRM 53-31-15-283-001. CARRIED OUT MEASUREMENT FND MATERIASDR HALA2022021000056None · noneSHIP 360 SEAT TRACK FROM FR 40 - FR 47 Y1959 FOUND CORROSION. CORRECTIVE ACTION: CARRIED OUT INSPECTION, FOUND CORROSION AT CROWN SURFACE AREA ALONG FRAME 46. CARRIED OUT REWORK AT SAID AREA IAW SRM 53-31-15-283-001. CARRIED OUT MEASUREMENT FND MATERIAL REMOVESDR HALA2022021000041None · noneSHIP 360 MAIN DECK SEAT TRACK AT Y1959 BETWEEN FRAME 28 - FRAME 37.4 FOUND MULTIPLE CORROSION. CORRECTIVE ACITON: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION IAW SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK IAW SRMSDR HALA2022021000040None · noneSHIP 360 MAIN DECK SEAT TRACK AT -Y 450, BETWEEN FRAME 28 - FRAME 37.4 FOUND MULTIPLE CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION I.A.W SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK I.ASDR HALA2022021000039None · noneSHIP 360 SEAT TRACK FROM FR 47 - FR 53.2 Y2462 FOUND CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION I.A.W SRM 51-72-11-911-001, REL 112, 04 JAN 22. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK I.A.W SRM 51-75-SDR HALA2022021000038None · noneSHIP 360 SEAT TRACK FROM FR 53.2 - FR 54 Y1959 FOUND CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION I.A.W SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK AS PER SRM 51-75-12-401. CARRIED OUTSDR HALA2022021400059None · noneSHIP 360 SEAT TRACK FROM FR40-FR47, Y450 FOUND CORROSION. CORRECTIVE ACTION: CARRIED OUT REPLACEMENT OF SEAT TRACK AT SAID LOCATION IAW SRM 51-72-11-911-001. CARRIED OUT APPLICATION OF EXTERNAL COATING ON SEAT TRACK I.A.W SRM 51-75-12-401. CARRIED OUT APPLICAT
Back to N360HA