N364NW
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N364NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N364NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021082505007Web · corrodedSHIP 3264 CORROSION WEB FRAME 20 STR23R AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED WEB PER SRM A320 51-72-11. (1923612)SDR DALA2021082304943Stiffener · crackedSHIP 3264 CRACK FRAME #1 STIFFENER FWD PRESSURE BULK HEAD LOCATED BTW Y254 TO -Y254 AT LOWER FUSELAGE. CORRECTIVE ACTION: REPLACED FR1 STIFFENER AND FASTENERS ON FWD PRESSURE BULK HEAD PER A320 SRM 51-72-11. (1921217)SDR DALA2021082004852Web · corrodedSHIP 3264 CORROSION FLOOR STRUCTURE WEB LOWER SURFACE AT LEVEL OF -Y1162 STR 23RH AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND A320 SRM 51-72-11. (1917577)SDR DALA2021082004851Web · corrodedSHIP 3264 CORROSION FLOOR STRUCTURE WEB LOWER SURFACE AT LEVEL OF Y1162 STR 23 AT AFT GALLEY AREA AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR STRUCTURE WEB PER A320 SRM 51-42-11 AND A320 SRM 51-72-11. (1917571)SDR DALA2021082004849Seat Track · corrodedSHIP 3264 CORROSION SEAT TRACK -Y1292 LOCATED BTW FR20 TO FR21 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER SRM A320 51-72-11. (1917573)SDR DALA2021082004848Floor Support · corrodedSHIP 3264 CORROSION FLOOR BEAM +Y1162.5 BTW FR68/69 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11 AND A320 SRM 51-42-11. (1917841)SDR DALA2021082004847Floor Support · corrodedSHIP 3264 CORROSION FLOOR BEAM -Y1162.5 BTW FR 68/69 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1917567)SDR DALA2021081904815Floor Support · corrodedSHIP 3264 CORROSION FLOOR BEAM -Y1162.5 AND -Y1292 BTW FR 66/68 AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER A320 SRM 51-72-11. (1916346)SDR DALA2021081604691Floorbeam · corrodedSHIP 3264 CORROSION FLOOR BEAM +Y765 AT LEVEL OF FR68 FLOOR STRUCTURE AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM PER SRM 51-72-11 AND 51-42-11. (1913082)SDR DALA2021081604690Fitting · corrodedSHIP 3264 CORROSION CENTER FITTING LOC. BTW FR16 AND FR20 STR 23L AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED CENTER FITTING PER A320 SRM 51-72-11. (1913092)SDR DALA2021081604689Seat Track · corrodedSHIP 3264 CORROSION SEAT TRACK -Y765 LOC. BTW FR20 TO FR21 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED SEAT TRACK PER SRM A320 51-72-11.SDR DALA2021081104590Support · corrodedSHIP 3264 CORROSION LOWER SILL LH SIDE AT LEVEL OF STR 23 LH AT AFT GALLEY AREA. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR PER A320 SRM 53-41-14. (1906891)SDR DALA2021081004565Door · out of adjustSHIP 3264 DURING RIGGING FOUND CREW DOOR 831 OUT OF ADJUSTMENT. CORRECTIVE ACTION: ADJUSTED DOOR PER A320 FAM AMM 52-11-21. OPS CK GOOD. (1905967)SDR DALA2021080404404Door · out of adjustSHIP 3264 CREW DOOR 842 OUT OF ADJUSTMENT. CORRECTIVE ACTION: ADJUSTED DOOR PER A320 AMM 52-13-21. OK FOR SERVICE. (1898463)SDR DALA2021080404403Door · out of adjustSHIP 3264 CREW DOOR 831 WAS OUT OF ADJUSTMENT. CORRECTIVE ACTION: ADJUSTED DOOR PER A320 AMM 52-11-14. OK FOR SERVICE. (1898457)SDR DALA2021031201408Fitting · damagedSHIP 3264 LH SIDE- FRAME 20 DOOR STOP FITTING #7, HOLE #1 HAS CIRCULAR DAMAGE IN FRAME AND INTERCOSTAL HOLE. CORRECTIVE ACTION: COMPLIED WITH ER/A 590512- 14AD REV ORIGINAL SECTION 1.SDR DALA2021011200177Psu · no testDURING DROP TEST PSU'S AT SEATS 21 ABC AND 27ABC DID NOT OPEN. CORRECTIVE ACTION: REPLACED PSU'S OPERATIONS CHECK GOOD SECOND TIME.SDR DALA2021011100163Psu · no testDURING TEST ROWS 2AB, 12ABC, 14DEF, 21DEF, 23DEF O2 MASKS DID NOT DEPLOY. CORRECTIVE ACTION: R & R PSU AT ROWS 2AB, 12ABC, 14DEF, 21DEF, 23DEF PER A320 AMM 25-25. PASSED SECOND TEST. OK FOR SERVICE.SDR DALA2019112606939Skin · chafedCHAFING EXTERNAL SKIN BETWEEN STRINGER 43L AND STRINGER 43R AT LEVEL FRAME 34 AT LOWER FUSELAGE, PERFORMED REPAIR SECTION I AS PER PRI 583239-14 REV.0 AND ER/A NO.583239-14AD REV. ORIGINAL ,SDR DALA2019112505470Frame · crackedSHIP 3264 WHILE INSPECTING PER JIC 5311-2036 (ALI 53-11-53) A CRACK INDICATION FOUN IN HOLE #6 OF FR16 RHS PER NTM 53-11-53-250-801. CORRECTIVE ACTION: FRAME 16 R/H WAS REPLACED AND IS DOCUMENTED ON DELTA WORKCARD 17/220 AND ER/A 583103-14AD REV A. (1375408)SDR DALA2019071704284Light · looseA/C 3264 CLOSED LOG 5930675. FLT/CHK MTC MIA 16JUL19. 17CDE EMERGENCY LIGHT ASSY IS LOOSE. ADJUSTED 17CDE EMERGENCY LIGHT ASSY - OPS CKS GOOD.SDR DALA2019040702280Light · detachedSEAT 32D EMERGENCY FLOOR LIGHTING DAMAGED, RESECURED EMER LT AT SEAT 32DSDR DALA2019030101324Light · unsecureSEAT 20 D EMERGENCY EXIT/FLOOR PROX. PATH SYSTEM LIGHT HANGING, RE SECURED EMER/EXIT FLOOR PATH LIGHT.SDR DALA2019021501067Light · inoperativeAFT INBOARD LAVATORY AUXILIARY LIGHT ABOVE DOOR INOPERATIVE. FOUND 28VDC INTERMITTENT AT TERMINAL BLOCK 7201VT-9. OPERATION CHECKS GOOD.SDR DALA2018120507084Bearing · corrodedNOSE LANDING GEAR RIGHT AFT TRUNNION BEARING SLEEVE CORRODED. REMOVED AND REPLACED BEARING IAW SRM 51-72-12.SDR DALA2018120507083Bearing · corrodedNOSE LANDING GEAR, LEFT AFT TRUNNION BEARING SLEEVE CORRODED. REMOVED AND REPLACED BEARING IAW SRM 51-72-12.SDR DALA2018111106603Filter · odorSTRONG DIRTY SOCK SMELL FROM TOP OF DESCENT TO AIRPORT. REMOVED AND REPLACED AVIONICS, CABIN RECIRCULATION, AND OZONE FILTERS. PERFORMED TASK CARD 7500-2001.SDR DALA2018090405416Trunnion · gougedLEFT HAND WING INBOARD FLAP TRUNNION GOUGED. REPLACED TRUNNION IAW ERA 571221-14AD AND 5751-01025-01C.SDR DALA2018090405418Trunnion · gougedLEFT FLAP TRUNNION GOUGED. REMOVED TRUNNION SLIDE PANEL INSTALLED NEW TRUNNION AND THEN REINSTALLED SLIDE PANEL. COMPLIED WITH ERA 571190-14AD.SDR DALA2018040502211Bracket · brokenSEAT 21D EMERGENCY LIGHT INOPERATIVE. REPLACED THE BROKEN LIGHT BRACKET.SDR DALA2017121808793Skin · corrodedCORROSION ON INTERNAL SKIN AT FRAME 66, STRINGER 32R IN THE AFT CARGO BAY. PERFORMED A PERMANENT REPAIR IAW PRI 563236-14, REV 0, AND ERA 563236-14 AD REV ORIGINAL.SDR DALA2016120609635Outlet · defectiveFLIGHT ATTENDANTS SMELLED SLIGHT ELECTRICAL SMOKE ODOR ROWS 22-25. TURNED OFF PED ELECTRICS NO SMELLS, REPLACED 21C PED OUTLETSDR DALA2015121407627Access Panel · corrodedCORRODED COUNTERSINKS ON ACCESS PANEL ON RT WING, REPLACED ACCESS PANEL.SDR DALA2015121007626Stringer · corrodedCORROSION ON STRINGER 43L BETWEEN FRAME 56 AND FRAME 57. REPLACED THE STRINGER IAW SRM 51-72-11 AND DWG D53470345.SDR DALA2015120907503Crossbeam · crackedCRACK ON CROSSBEAM LOCATED FRAME 68 AT LEVEL STR 23R AT AFT GALLEY AREA, REPLACED CONNECTING SECTION OF CROSSBEAM LOCATED FRAME 68 AT LEVEL STR 23R AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53474250. MEASURE OF CRACK IS L=0.438".SDR DALA2015120907502Door Sill · corrodedCORROSION ON LOWER SILL STR 23R AT AFT GALLEY AREA L=0.600", W=0.400", D=0.006", REPLACED LOWER SILL, STR 23R AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505, D53480076, D53470150 MEASURES OF REWORKED AREA ARE: L=1.335", W=1.198", D=0.098".SDR DALA2015120707442Seat Track · corrodedCORROSION ON SEAT TRACK 1292 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA L=1.500", W=0.800", D=0.008". REPLACED FLOORBEAM 1292 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112812. MEASURESS OF CORRODED AREA ARE: L=3.257", WSDR DALA2015120707441Floor Support · corrodedCORROSION ON FLOORBEAM 765 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA, L=0.800", W=0.300", D=0.010". REPLACED FLOORBEAM 765 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112812. MEASURES OF CORROSION L=0.477", W=0.380", D=0SDR DALA2015120707440Floor Support · corrodedCORROSION ON FLOORBEAM 254 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA L=0.900", W=0.300", D=0.006. REPLACED FLOORBEAM 254 BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53111462 AND D53110900. MEASURES OF CORROSION ARE: L=3.47SDR DALA2015120707439Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 LT AT AFT GALLEY AREA, REPLACED CORNER FITTING FRAME 68 LT AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480505. MEASURES OF REWORKED AREA ARE: L=3.178", W=0.884", D=0.021".SDR DALA2015120607412Dummy Rail · corrodedCORROSION ON RAIL DUMMY -189 BETWEEN FRAMES 20 TO 24. REPLACED THE DUMMY RAIL IAW SRM 51-72-11 AND DWG D53112834.SDR DALA2015120507409Fitting · corrodedCORROSION ON CORNER FITTING FRAME 16 AT STR 23L. REPLACED THE FITTING IAW SRM 51-72-11 AND DWG D53112225.SDR DALA2015120407408Fitting · corrodedCORROSION ON CORNER FITTING FRAME 20 AT STR 23R. REPLACED THE FITTING IAW SRM 51-72-11 AND DWG D53112225.SDR DALA2015120407407Door Sill · corrodedCORROSION ON LOWER DOOR SILL. REPLACED THE DOOR SILL BETWEEN FRAMES 66 AND 68 IAW SRM 51-72-11 AND DWG D53480505, D53480078, D53470150.SDR DALA2015120407406Floor Support · corrodedCORROSION ON FLOOR SUPPORT -1732 BETWEEN FRAMES 65 TO 66. REPLACED FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472075, D53474250, D53472750.SDR DALA2015120307405Floor Support · corrodedCORROSION ON FLOOR SUPPORT +765 BETWEEN FRAMES 66 TO 70. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53272000.SDR DALA2015120307404Floor Support · corrodedCORROSION ON FLOOR SUPPORT -1292 BETWEEN FRAMES 66 TO 68. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472845, D53472816.SDR DALA2015120307403Floor Support · corrodedCORROSION ON FLOOR SUPPORT +1292 BETWEEN FRAMES 66 TO 68. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472845.SDR DALA2015120307402Floor Support · corrodedCORROSION ON FLOOR SUPPORT -Y464.75 BETWEEN FRAMES 64 TO 67. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472816.SDR DALA2015120307401Floor Support · corrodedCORROSION ON FLOOR SUPPORT +Y1162 BETWEEN FRAME 68 TO 69 . REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53472845.
Back to N364NW