N368AS
Service difficulty reports · 16
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N368AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N368AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR E07A202603260227Support Bracket · crackedFOUND CRACK ON LH AND RH NOSE OMEGA BEAM FORWARD SUPPORT BRACKETSDR 2025FA0000099Windshield · crackedLH WINDSHIELD CRACKED IN CLIMB AT FL 270SDR 2025FA0000098Windshield · crackedLH WINDSHIELD CRACKED IN CLIMB AT FL 270SDR XMXR202107220001Shutoff Valve · failedON TAXI OUT. ECS 2 FAIL CAS. ECS DISPLAY SHOWED RED X ON ECS VALVE 2.SDR XMXR20210301004Shutoff Valve · failedBLEED 1 OVER PSI, FOLLOWED BY BLEED1 FAIL IN FLIGHTSDR XMXR20191211022Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR XMXR20191211021Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON. REPLACED BATTERY PACK.SDR E07A201912020005Precooler · crackedCRACKED RT PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR E07A201912020004Precooler · crackedCRACKED RH PRECOOLER INLET DIVERTER WELDS FOUND DURING INSPECTION IAW SERVICE LETTER 505-36-0003. REPLACED WITH OVERHAULED UNIT.SDR E07A201802230006Baffle · brokenBLEED 1/2 FAIL. IAW SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER. REPLACED PRECOOLER ASSY.SDR E07A201802230005Baffle · brokenBLEED 1/2 FAIL. PER SIL505-36-0003 INSPECTED ENGINE PRECOOLER AND FOUND INLET AIR DEFLECTOR BAFFLES BROKEN OFF AND LAYING ON TOP OF COOLER.SDR E07A201802140016Bearing · damagedENROUTE, CREW RECEIVED A NR 2 GENERATOR OFFLINE, WITH VIBRATION. ENGINE THROTTLED BACK TO IDLE. VIBRATION STILL PRESENT. CREW PERFORMED PRECAUTIONARY ENGINE SHUTDOWN IAW QUICK REFERENCE HANDBOOK AND DIVERTED. RT STARTER FOUND WITH BEARING DAMAGE.SDR E07A201710160001Interface Unit · inoperativeCREW RECEIVED NUMERIOUS CAS MESSAGES FROM MULTIPLE SYSTEMS. PFD1 WENT INTO REVERSIONARY MODE. GEA 2 WAS DETERMINED TO HAVE GONE OFF LINE.SDR E07A201802140013Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ON.SDR E07A201802140014Battery Pack · failedEMERGENCY LIGHTS STAYS ON IN ARM POSITION OR FLASHES ON/OFF IN ARM AND ONSDR E07A201608240002Ahrs · faultedAHRS1 FAIL, AP/FD FAIL, YAW DAMP FAIL. EMERGENCY DECLARED AND DECENT DUE TO CREW PERCEIVED AHRS2 FAIL THAT WOULD CAUSE VENTRAL RUDDER FAIL AND DUTCH ROLL TENDENCIES. AHRS1 RESTARTED AND ALL SYSTEMS RETURNED TO NORMAL. CMC EVALUATION AND FIM TASK FOR AHRS1 D
Back to N368AS