N3737C
Service difficulty reports · 131
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N3737C' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N3737C' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2024092609451Floorbeam · corroded(LOG 0575492) CORROSION ON FLOOR BEAM STA=986.5, LBL=11 TO LBL 44 AT CPAX. FLOOR BEAM STA=986.5, LBL=11 TO LBL 44 WAS REPAIRED PER B737-800 SRM 53-70-51-2R PROCEDURE 4 REPAIR 4.SDR DALA2024092409381Floorbeam · corroded(LOG 0572433) CORROSION ON FLOOR BEAM STA=986.5, RBL= 33 TO RBL 34 AT CPAX (W2). CORROSION ON FLOOR BEAM STA=986.5, RBL= 33 TO RBL 34 AT CPAX WAS REMOVED UNDER NRC 0375 AND WAS REPAIRED PER B737-800 SRM 53-70-51-2R PROCEDURE 6 REPAIR 6.SDR DALA2024082308410Battery Pack · inoperative(LOG 0515226) EMERGENCY EXIT LIGHTS OVER LEFT FWD OVERWING DOOR INOP. R/R EMERGENCY LIGHT BATTERY PACK M1694 IAW B737 AMM 33-51.SDR DALA2024072207343Window Frame · cracked(LOG 5794376) DURING CAPTAIN #1 WINDSHIELD REMOVAL FOUND / SUSPECT LT #3 WINDOW FRAME CRACK AT BOTTOM SIDE. REPAIRED PER ERA 619441-14.SDR DALA2024071907294Stanchion · cracked(LOG 0452706) DURING OVERNIGHT IN CVG ON 11-JULY-2024, MTC DISCOVERED DAMAGE CONSISTING OF A CRACK RUNNING HORIZONTALLY ACROSS THE VERTICAL STANCHION (E-F POST) THROUGH A FASTENER LOCATION COMMON TO THE WINDOW FRAME ASSEMBLY OF THE LH NO. 3 FLIGHT COMPARTMENT SDR DALA2024071607178Window Frame · cracked(LOG 5794374) ON SVC CHK WHILE CLEANING WINDSHIELD FOUND CRACK ON CAPTAINS #1 WINDOW FRAME. REPAIRED CRACK PER ERA 619423-14.SDR DALA2024071807257Window Frame · cracked(LOG 0444041) B737-800 FUSELAGE NOSE CAPTAINS WINDSHIELD NO. 1 WINDOW FRAME UPPER OTBD CORNER CRACK. REPAIRED PER ERA 619423-14.SDR DALA2024040103946Battery Pack · inoperative(LOG 0265216) 1R EMERGENCY EXIT LIGHTS ILLUMINATED DURING TAKEOFF ROLL. T/S PER WDM 33-51-12. R/R BATTERY PACK AND POWER SUPPLY AND INSTALL TEST OK IAW B737 AMM 33-51. A/C OK FOR SVC.SDR DALA2024032503731Connector · disconnected(LOG 5747769) DURING SVC CK, FOUND DOOR 1L EMER LIGHT INOP. FOUND CONNECTOR D11072 DISCONNECTED. RE-CONNECTED CONNECTOR AND CHECKS GOOD.SDR DALA2024031803401Power Supply · inoperative(LOG 5747744) DURING SERVICE CHECK FOUND CABIN EMERGENCY EXIT SIGN LIGHT AT MID AISLE OVERHEAD INOP. REMOVED AND REPLACED THE POWER SUPPLY FUSE AT M1670 IAW B737 AMM 33-51-06. OPS CHECK GOOD.SDR DALA2024011800765Battery Pack · inoperative(LOG 4340449) SECTION OF SEAT MOUNTED EMERGENCY LIGHTS INOP AFT OF OVERWING EXITS. RPLD BATTERY PACK FOR PWR SUPPLY M1671 PER B737 AMM 33-51. OPS CKS GOOD.SDR DALA2024011800764Battery Pack · inoperative(LOG 4340448) FIRST CLASS SEAT MOUNTED EMERGENCY EXIT LIGHTS INOP. RPLD BATTERY PACK FOR PWRSUPPLY M1674 PER B737 AMM 33-51. OPS CKS GOOD.SDR DALA2023122910711Unknown · unknownSHIP 3737 -ATB/UFC- RETURNED TO LAX DUE TO AILERON CONTROL ISSUES. CORRECTIVE ACTION: FOUND #9 FLIGHT SPOILER FLUTTERING. REPLACED FLIGHT SPOILER ACTUATOR. OPS CHECKS GOOD.SDR DALA2023101608470Unknown · unknown(LOG 0013059) WHILE ACCOMPLISHING WINGLET MODIFICATION PER EA 12-468783-03, JUST IB OF RIB 19 ON STRINGER 8 ON THE LH WING, MTC DRILLED A HOLE IN THE WRONG LOCATION. REPAIRED PER ERA 474401-14.SDR DALA2022111807424Idg · failedSHIP 3737 -DIV- DISPATCHED IAD WITH RT IDG ON MEL. ENROUTE LOST APU, DOWN TO SINGLE ELECTRICAL SOURCE, DIVERTED TO MSP. CORRECTIVE ACTION: REPLACED RT IDG. APU AUTO SHUTDOWN DUE TO LOW OIL PRESSURE. CLEANED OIL COOLER, CHANGED OIL AND FILTER. REPLACED LOP SWITSDR DALA2022091906194None · noneSHIP 3737 -SMOKE/ODOR- RETURN TO BLOCK DUE TO REPORT OF SMOKE COMING FROM THE AFT GALLEY DRAIN. CORRECTIVE ACTION: PERFORMED ALL REQUIRED INSPECTIONS WITH NO TROUBLE FOUND.SDR DALA2022011000158None · none(LOG 8059233)DURING INSPECTION FOUND NO 2 FLAP OUTBOARD FLAP TRACK FAIRING TAIL CONE MISSING. IRO NBR 3 INBOARD FLAP TAIL CONE FAIRING FWD TO CDL 57-10-04. PLAC INSTALLED. "SUPPLEMENTAL INFORMATION" 01/13/22, STATION LAX. AFTER FURTHER INVESTIGATION IT WAS DETSDR DALA2021101806394None · none(LOG 1985053) DURING INSPECTION FOUND SCRATCHES ALONG PREVIOUS REPAIR LOWER SKIN AND GOUGE AT LOWER SKIN SURFACE BTW STAB STA 129.5 AND 157.1 APROX OF RH HOR STAB. SCRATCHES ALONG PREVIOUS REPAIR WAS REPAIRED PER B737-800 SRM 55-10-01-2R PROCEDURE 11.SDR DALA2021101806393None · none(LOG 1984534) DURING INSPECTION FOUND ELONGATED HOLE AT AFT WING-TO-BODY FAIRING PANEL 193D SUPPORT STRUCTURE BTW STA BS 725. PERMANENT REPAIR ON ELONGATED HOLE AT AFT WING-TO-BODY FAIRING PANEL 193D SUPPORT STRUCTURE BTW STATION BS 725 WAS PERFORMED PER ETI-3SDR DALA2021101806392None · none(LOG 1984317) DURING INSPECTION FOUND WORN SETTLEMET AREA OF NUTPLATES ON SUPPORT STRUCTURE. PERMANENT REPAIR ON SETTLEMET AREA OF NUTPLATES ON SUPPORT STRUCTURE STA BS 727+2.7. WAS PERFORMED PER STEP NO.1 UNTIL STEP NO.17 OF ETI-37-21-500 REVISION. 2 AND ER/ASDR DALA2021101406357None · none(LOG 1981318) DURING INSPECTION FOUND ELONGATED HOLES (7 EA) AT AFT WING-TO-BODY FAIRING PANEL 193D. ELONGATED HOLES (7 EA) AT AFT WING-TO-BODY FAIRING PANEL 193D WERE REPAIRED PER B737-800 S.R.M 51-70-05-2R PROCEDURE 8 PAR. 4. AND B737-800 S.R.M. 51-70-05-2R SDR DALA2021101306263None · none(LOG 1977363) DURING INSPECTION FOUND CRACK ON LH HOR STAB LWR SKIN SURFACE STATION 101.90. LH HOR STAB LWR SKIN SURFACE STA 101.90 WAS REPAIRED PER B737-800 SRM 55-10-01-2R REPAIR 11.SDR DALA2021091005355Battery Pack · inoperative(LOG 7865108) DURING INSPECTION FOUND EMERGENCY LIGHT SIGNS AT ROWS 17-18ABC INOP. REMOVED AND REPLACED BATTERY PACK AT POWER SLED M1694 IAW B737 AMM 33-51. EMERGENCY LIGHT SIGNS CK GOOD.SDR DALA2021022201027Control Panel · inoperativeSHIP 3737 -ATB- DUE TO AUTOPILOT MCP (MODE CONTROL PANEL) ALTITUDE SELECTOR INOPERATIVE. CORRECTIVE ACTION: REPLACED AUTOPILOT MODE CONTROL PANEL. OPS CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR DALA2021010400030Door · damagedDURING INSPECTION FOUND DAMAGE BEHIND 2L DOOR. REPAIR REF SRM 53-70-01-2R PROCEDURE 1 REPAIR 1.SDR DALA2020032001970Bushing · damaged(LOG 1534104) LEFT HORIZONTAL STABILIZER: AFT LOWER ATTACH POINT, BUSHING HAS TOOLING DAMAGE. MAINTENANCE REPAIRED DAMAGE PER ERA 586222-14.SDR DALA2020032001969Bushing · excess play(LOG 1534110) LEFT HORIZONTAL STABILIZER FWD ATTACH POINT, ON AIRCRAFT FWD LOWER BUSHING HAS EXCESSIVE PLAY WITH ITS ATTACH BOLT. MAINTENANCE REPAIRED DAMAGE PER ERA 586096-14.SDR DALA2020032001968Bushing · excess play(LOG 1534109) RIGHT HORIZONTAL STABILIZER AFT LOWER ATTACH POINT, EXCESSIVE PLAY BETWEEN BOLT AND BUSHINGS. MAINTENANCE REPAIRED DAMAGE PER ERA 586226-14.SDR DALA2019022701304Fuse · defective(LOG 5538096) DURING INSPECTION FOUND RIGHT AFT OVERWING EXTERIOR EMERGENCY EVACUATION LIGHT INOPERATIVE. FOUND DEFECTIVE FUSE IN M1671 BATTERY CHARGER . REPLACED SAME PER AMM 33-51-06. OPS CHECK GOOD.SDR DALA2019011600283Control Module · malfunctioned(LOG 5367134) ABOUT 25 MILES FROM LANDING AUTOBRAKE DISARM & "ANTI SKID INOP" LIGHT ILLUMINATED. PERFORMED QRH PROCEDURE AND DECLARED EMERGENCY. LANDING 40 DEG FLAP, EASY ON BRAKES, CONTINUED TO GATE WITHOUT INCIDENT. FOUND HIGH RESISTANCE ON PIN 1 AND PIN 2 OSDR DALA2018111206593Cover · defectiveDURING INSPECTION FOUND EMER EXIT LIGHT SWITCH COVER HAS LOST SPRING TENSION AND IS HANGING DOWN. R&R SWITCH COVER IAW SWPM 20-84-13, OPS CHECK GOOD.SDR DALA2018102906346Battery Pack · dischargedDURING INSPECTION FOUND EMERGENCY LIGHTS AT SEAT ROW 11-15 INOP. REMOVED AND REPLACED BATTERY PACK AND CHARGER EIN M1676 PER AMM 33-51. OPS CK GOOD.SDR DALA2018102206201Frame · dented(LOG 0793354) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 500A BETWEEN STR 25L AND 26L AT FWD CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 500A BETWEEN STRINGER 25L & 26L AT FORWARD CARGO COMPARTMENT WAS REPAIRED PERSDR DALA2018102206200Frame · dented(LOG 0793183) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 727C STR 24L AT AFT CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 727C STRINGER 24L AT AFTER CARGO COMPARTMENT WAS REPAIRED PER ETI-37-18-533 REVISION 2 AND ERSDR DALA2018102206199Frame · dented(LOG 0793173) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED IN TWO PLACES STATION 727H BETWEEN STR 23L AND 25L AT AFT CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 727H BETWEEN STRINGER 23L AND 25L WAS REPAIRED PER ETI-37-18-53SDR DALA2018102206198Stringer · cracked(LOG 0793117) DURING INSPECTION FOUND CRACK ON STRINGER 28R ON STATION 325 E/E. STRINGER 28R BS 312-323.7 WAS REPAIRED PER ETI-37-18-541 REVISION ORIGINAL AND ER/A 572452-14.SDR DALA2018102206203Frame · dented(LOG 0793132) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 420 BETWEEN STR 25L AND 26L AT FWD CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 420 BETWEEN STRINGER 25L & 26L AT FORWARD CARGO COMPARTMENT WAS REPAIRED PER ESDR DALA2018102206197Skin · dented(LOG 0792103) DURING INSPECTION FOUND DENT ON EXTERNAL FUSELAGE SKIN BTW STATION 318, BTW STR 28R AND PROYECTION 29. DAMAGE ON EXTERNAL FUSELAGE SKIN BTW STATION 318, BTW STR 28R AND PROYECTION 29 WAS REPAIRED PER ETI-37-18-525 REV. 5 AND ERA 572505-14.SDR DALA2018102206196Frame · dented(LOG 0791423) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 727E BETWEEN STR 23L AND 24L. AT AFT CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 727E, BETWEEN STRINGER 23L & 24L AT AFTER CARGO COMPARTMENT WAS REPAIRED PERSDR DALA2018102206195Plate · corroded(LOG 0791298) DURING INSPECTION FOUND CORROSION ON SIDEPLATE LT STATION 500A TO 500I. LT SIDEPLATE STATION 500A TO 500I WAS REPLACED PER SRM 53-30-53.SDR DALA2018102206194Frame · dented(LOG 0791294) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 500C ABOVE STR 24L AT FWD CARGO COMPARTMENT. DENTED FUSELAGE FRAME FREE FLANGE AT STATION 500C ABOVE STRINGER 24L AT FORWARD CARGO COMPARTMENT WAS REPAIRED PER ETI-37-18-530 REVSDR DALA2018101906173Frame · dented(LOG 0790266) DURING HCK AT QRO ONE DENT WAS FOUND AFFECTING THE BS 727E FRAME 146A1225-7 BETWEEN S-23L AND S-24L. MAINTENANCE REPAIRED DAMAGE PER ERA 572482-14.SDR DALA2018101906171Beam · corroded(LOG 0790398) DURING INSPECTION FOUND CORROSION ON BEAM STATION = 986 BTW RBL 54 TO LBL 54 AT CABIN PAX. CORROSION ON BEAM STA = 986 BTW RBL 54 TO LBL 54 AT CABIN PAX. FLOOR STRUCTURE BEAM AT STATION 986.5 (PASSENGER COMPARTMENT) WAS REPAIRED PER ETI-37-18-524SDR DALA2018101906170Frame · dented(LOG 0790339) DURING INSPECTION FOUND FUSELAGE FRAME FREE FLANGE IS DENTED STATION 767 BETWEEN STR 22 LT AND 23 LT AT AFT CARGO COMPARTMENT. DENTED FUSELAGE FRAME FLANGE AT STATION 767 BETWEEN STR 22L AND 23L AT AFTER CARGO COMPARTMENT WAS REPAIRED PER ETI-37-SDR DALA2018101906169Stringer · corroded(LOG 0790312) DURING INSPECTION FOUND CORROSION ON STRINGER 28L BTW STA 500F+10 AND 500G+8 AT FWD CARGO COMPARTMENT. CORROSION ON STRINGER 28L BTW STATION 500F+10 AND 500G+8 AT FWD CARGO WAS REPAIRED PER SRM 53-00-03.SDR DALA2018101906168Structure · cracked(LOG 0790044) DURING INSPECTION FOUND CRACK ON LT HORIZONTAL STABILIZER LOWER CHORD STA SS 285.9 FRONT SPAR AREA. LT HORIZONTAL STABILIZER LOWER CHORD STATION SS 285.9 FRONT SPAR WAS REPAIRED PER ER/A 572326-14 REV ORIG AND ETI -37-18-522 REV 2.SDR DALA2018101806151Intercostal · cracked(LOG 0788841) DURING INSPECTION FOUND CRACK ON INTERCOSTALS BTW STATION 500A-500B, BTW 500B-500C, BTW 500C-500D,BTW 500E-500F, BTW 500F-500G, BTW 500G-500H, 500H-500I. DAMAGED INTERCOSTALS WERE REPLACED PER SRM 51-40-02.SDR DALA2018101806150Plate · corroded(LOG 0788206) DURING INSPECTION FOUND CORROSION OUT OF LIMITS ON LT ZEE SIDEPLATE FROM STATION 727G TO STA 807. LEVEL CORROSION 2 SIDE PLATE LT STATION 727G TO 807 WAS REPLACED PER SRM 51-40-02.SDR DALA2018101806149Plate · cracked(LOG 0788117) DURING INSPECTION FOUND CRACKS ON LT ZEE SIDEPLATE FROM STATION 727A TO STATION 727B (3EA) AND STA 727F. SIDE PLATE LT ON STATION 727A TO STA 727F WAS REPLACED PER SRM 51-40-02.SDR DALA2018101606076Intercostal · corroded(LOG 0785810) DURING INSPECTION FOUND CORROSION ON INTERCOSTAL AT LONG 27 BTW 727A TO 727B. LEVEL CORROSION 2 INTERCOSTAL WAS REPLACED PER SRM 51-40-02.